Document QJkX19GEb1bQwnaD1Oqx08R7v

' Monsanto R. W. Peterson - General Offices May 23, 1968 cc .......... ... , , K,r. CEA 1430 - Expand Aroclor at Anniston Temperature Control of Common Biphenyl - Santowax System TO W- F. Taffee Anniston, Alabama R. G. Corley B. D. Das Lfv..! Faulkrie#' - Anniston R. A. Haydel - Anniston R. C. Herman/R. H. Henning W. H. Howard R. M. Kountz V. T. Langdon - Anniston P. K. Ward - Anniston H. L. Williams - Anniston We have agreed to flake Santowax on the Biphenyl flaker a small part of each year. You have proposed a common line for Biphenyl and Santowax transfers to keep the cost of this func tion down. Santowax must be held at 150C for flaking and should be transferred in a line jacketed with 100 ps^g (170C) steam. However, Biphenyl has a freezing point of 69UC and a desired flaking temperature of 85C. Its open cup flash point is 123UC. The following ideas are proposed as ways to keep from overheating Biphenyl beyond a safe storage or good flak ing temperature. 1. Transfer Line (2" pipe in 3" jacket) 2 This 300 ft. line acts like a 162 ft heat exchanger. However, for 85 C biphenyl the losses are only 13,600 BTU/hr. or 15 lbs. of steam/hr. I propose that we have an orifice to meter in 20-30 lbs. of steam per hour, which could be bypassed when handling Santowax. When idle, the line would be hot enough to keep Biphenyl drips from freez ing, and would prevent condensate from freezing in the winter. When transferring 85C Biphenyl the steam would go under vacuum. Steam pressure at 85 c is 9 psia and would require a 21 ft. water column for release. No trap back pressure would be allowed. We would use a french drain in stead of recovering condensate to a pig. However, when the transfer is over the vacuum will end and any condensate hang-up will stop. The condensate leg must be insulated. This way we could transfer Biphenyl without significant temperature rise and without extra operator attention. 2. Flaker Feed Tank 815 When storing Biphenyl the heat losses are only2l2,600 BTU/ hr. This could be supplied by a small (1-2 ft ; bayonet or plate coil with 100 psig steam. This would be connected to a temperature controller set at 85C. Some extra area could be provided for remelting of Biphenyl flakes in the manhole basket. The main plate coil would be for use only for Santowax, and the plant would be responsible to see it was disconnected and blown out in between usage. 03**028 TOWOLDMONOQ44672 W. F. Taffee 2 May 23, 1968 The recirculation lines at tank 815 would be jacketed, but the steam would be normally disconnected for Biphenyl to avoid overriding the temperature control. The operator could manually steam out the jackets to fight freeze-ups. This also applies to the feed line to the flaker. 3. Flaker Pan, Item 816 With the flaker feed rate around 10 GPM, little reheat is expected from the flaker pan plate coil. It would be con nected to 100 psig steam with a 1/4" line and globe valve, with a bypass for Santowax. If this plan is acceptable to you we will proceed on this basis. R. W. Peterson Project Manager vo TOWOLDMONOQ44673 -yui'^y 0354029.01 TOWOLDMONOQ44674