Document QJ8qrRj9aqJ2pK6NZZQpdeeak

e**-'027 REV 2-44 CST4IUJMI01*0> E. I. DU Pont de Nemours & Company >NCOMI*OltATCO Wilmington. Delaware i9898 ENGINEERING DEPARTMENT January 18, 1968 / hr J. S. QUEENER, MANAGER SAFETY k FIRE PROTECTION DIVISION N-12430 ASBESTOS DUST SURVEY We have recently completed an asbestos dust survey in the Construction Division and thought that you may be interested in a resume of the survey as well as what we will be doing in the future to control this exposure. The survey was conducted over the past year under the guidance of A. L. Linch, Medical Section, Chambers Works, with a two-fold purpose in mind, we wish to cteterffllrtfi to what extent our employees are exposed in performing the various work requirements and develop what would be necessary to provide the minimum employee exposure to asbestos dust. Enclosed is the resume of the survey conducted. SAMPLE A - Outline of the program we undertook covering the objective and the manner in which we performed the survey. SAMPLE B - Outline of the practices we applied in the Chambers Works Construction Insulation Shop. These practices were intended' to cover the normal construction shop environmental condition and work method. SAMPLE C - Interim report - asbestos survey based on analyses made by Dr. Corn-and Dr. Manella of the University of Pittsburgh. SAMPLE D - Interim report No. 2, asbestos survey. SAMPLE E - Final report and recommendations received from A. L. Linch, Medical Section, Chambers Works. Mr. Linch conducted this survey for us. SAMPLE F - Self-explanatory. SAMPLE G - Recommendations received from G. J. Stopps, Haskell Laboratory, to be included in the policy adopted in the Construction Division. We will eliminate through specifications future purchase of materials containing crocidolite asbestos fibers. Haskell Laboratory will conduct future monitoring analyses for the Division. BETTER THINGS FOR BETTER LIVING . . . THROUGH CHEMISTRY DUP 1111073 ooi.:co DU 055065 2 J. S. C.ueener January IS, 196S If you have any further questions regarding any of the information contained herein, please do not hesitate to contact the writer. We will keep you advised of future developments. CONSTRUCTION DIVISION K. E. Keuper Division Safety Superintendent KEK/dlm Enclosures OUP UH074 DU 055066