Document QJ65889gwZYaqxn0O8jMJKqxE
!
OATS ISSUEO .
<I
Allegheny Power System
June 7, 1977
ISSUEO BY
Vimasco Corp, GcrOt +> u<o0
.Q o<0
Oo <<oa
PLAINTIFF'S
CHEMICAL SAFETY DATA
A EXHIBIT
f ls/m-g
1 PRODUCT IDENTIFICATION
"
manufacturer's name Vimasco Corporation
REGULAR TELEPHONE
i30u) (5^-3320
EMERGENCY TELEPHONE NO.(304 ) 342-6495
adoress
Plant Road, P. 0. Box 516, Nitro, W. Va. 25143
TRADE NAME Vimasco Cable Coating No. 1-A
svwnuYus Water-dispersed vinyl-acetate/dibutyl-maleate emulsion with selected binders, SYNONYMS finers. and fire-retardant ingredients
II HAZARDOUS INGREDIENTS
MATERIAL OR COMPONENT
--ItcC----
. %,
bv weight
hazard oata*
Asbestos, chrysotile
Le ss than Acute local; Irritant 1
5% Inhalation 2
Acute systemic: 0
Chron: c local: Inhalation ?
Chronic systemic: U TLV: 5 mppcf
Antimony oxide
. Le 3s than TLV: 0.5 mg/ra^ 5-6
Silica
9* TLV: 20 mppcf
* NOTE:
These ingredients present no known haard In either the wet or cured product; thev are thoroughly disoersed and encaosul ated in t le finii hed oroduct.
ill PHYSICAL DATA FOR WET PRODUCT AS SHIPPED
BOILING POINT, 760 MM HG SPECIFIC GRAVITY (H20=1> VAPOR OENSITY (AIRS1)
212F 1.3 N/A
MELTING POINT N/A
VAPOR PRESSURE N/A Water-
SOLUStLLTY ,N 20. , BY WT. dispersible
% VOLATILES BY VOL. APPEARANCE ano OOOR
PORm c 23-0 39
h2$ EVAPORATION RATE (BUTYL ACETATEsil N/A
Moderate-viscosity mastic consistency, color gray or as selected; mild odor of polyvinyl-acetate latex
IV FIRE AND EXPLOSION DATA FOR WET PRODUCT AS SHIPPED
flash point
(TEST METHOOI
n/a
AUTO IGNITION TEMPERATURE
N/A
FLAMMABLE LIMITS IN AIR. r. 8Y VOL.
LOWER
J|/A
UPPER
EXTINGUISHING MEOIA
N/A
'
SPECIAL FIRE FIGHTING PROCEDURES
UNUSUAL FIRE ANO EXPLOSION HAZARO
N/A N/A
'
V HEALTH HAZARD INFORMATION
health hazard oata No known health hazard la wet or dry state ROUTES OP EXPOSURE
..
inhalation Never experienced
SKIN CONTACT Non-tOXlC
skin.absorption
j^ovn to occur
eye contact ingestion
Primary irritation Never experienced
EFFECTS OF OVEREXPOSURE acute overexposure No known effects
chronic overexposure No known effects
EMERGENCY AND FIRST AlO PROCEDURES eyes: Flush immediately with large amounts of clean water
skin: Wash with soap and water
inhalation: No known hazard
ingestion: Induce vomiting; flush with large amounts of clean water
notes to physician This is a water-dispersed, latex-based, pigmented, raoderate-viscositj mastic material, which cures to a flexible film. It is for industry/professional use only. As formulated and shipped, it has no known toxicity either wet or dry.
V
' ' CONDITIONS CONTRIBUTING TO INSTABILITY
None known
I `
INCOMPATIBILITY
None known
HAZARDOUS DECOMPOSITION PROOUCTS Small amounts Jo*f, HC1 &gas can be released when the cured film is exposed to fire under certain conditions. Since this is a fire-retardant
coating the net amount of toxic products of combustion released during a fire would
normally be less than what would have been released from uncoated cables if the coating nr+ tfrider no known circumstances of normal use will the coating result
in a significant addition of toxic oroducts of fire conditions. CONDITIONS CONTRIBUTING TO HAZARDOUS POLYMERIZATION
Hazardous polymerization is not known to occur under any conditions.
VII SPILL OR LEAK PROCEDURES
..
steps to be taken if material is released or spilled the material cures.
Clean up with water or rags before
NEUTRALIZING CHEMICALS N/A
waste disposal methoo Follow federal, state, and local regulations for disposal of water-borne latex products.
VIII SPECIAL PROTECTION INFORMATION
ventilation requirements During application and curing, ventilate area as well as possible.
: SPECIFIC PERSONAL PROTECTIVE EQUIPMENT
Material is non-toxic. Under normal conditions of use, respiratory (specify .N oeta.u QO respiratory equipment is required.
eye Use goggles during spray application.
gloves use normal work gloves.
other clothing and EQUIPMENT
Use same safety precautions you normally follow for
water-dispersed, latex-based products.
precautionary
STATEMENTS
IX SPECIAL PRECAUTIONS
For industry/professional use only. Product should not he ingested and should he kept out of the reach of
children. Follow normal precautions for storing and applying water-dispersed,
latex-based products.
OTHER HAJ40LING ANO storage requirements
Protect from freezing and boiling (water-dispersed material).
Ideal storage temperature is 6Q-80*F. Do not store below LO*F,
PREPARED BY:. Vimasco Corporation AOORESS. Plant Road, P. 0. Box'516, Nitro, W. Va. 2511*3
date June t 1977
INSTRUCTIONS FOR PREPARING THE CHEMICAL SAFETY DATA SHEET
General Information
All sections of Che Chemical Safety Data Sheet may not be applicable. When this is the case, the words "not applicable'* shall be written in that section. How ever, Part V, Health Hazard Data, and Part VIII, Special Protection Information, shall be completed.
When a temperature is requested, it shall be listed in degrees Fahrenheit with degrees centrigrade in parentheses, e.g.,F (C).
Part I - Product Identification
The manufacturer's name listed should be a source of detailed backup information
on the hazards of the product.
Part II - Hazardous Ingredients
LU. of volume may be listed as a range or maximum amount, e.g., 10-40% , ' or 10% maximum weight.
Hazard data shall be: (1) Stated in terms of concentration, mode of exposure or test, and animal used, e.g., 74 ppm LC man, or,
*' (2) Permissible exposure from 29 CFR 1910.93.
Part III - Physical Data The information in this section shall apply to the total mixture.
Part IV - Fire and Explosion Data
This section shall contain complete fire and explosion data for the product. product presents no fire hazard, write "no fire hazard" on the line labeled "extinguishing media."
If the
Part V - Health Hazard Information
Health hazard data should be a combined estimate of the hazard of the total product, expressed as a time-weighted average concentration or permissible exposure.
The comments in each category under Principal Routes of Absorption should reflect
the potential hazard from absorption by this route. Comments should indicate the
severity of the effect and the basis for the statement, if possible. A typical
comment might be, "Prolonged or repeated contact--mild irritation and possibly
some blistering."
..
All statements should be written in lay language.
2
Parc VI - Reactivity Data
'
Comments in this section relate to safe storage and handling of Che product.
Those products released under fire conditions and aging of the product are to be listed. Shelf life of the product should also be listed.
Part VII - Spill or Leak Procedures
This section shall contain detailed procedures for cleanup and disposal with emphasis on precautions to be taken to protect workers assigned to cleanup detail. Specific neutralizing chemicals or procedures should be specified in detail. Disposal methods should be explicit. Specific procedures shall be identified.
Part VIII - Special Protection Information
Specific information is required in this section. Ventilation requirements should be specific as to type and preferred methods. Respirators shall be specific as to type and NIOSH approval class. Protective equipment must be specified as to
tad materials of construction.
Part IX - Special Precautions
Additional information on any aspect of safety or health not covered in other sections should be listed here, along with references to published guides on procedures for handling and storage.
-- t*
AflSA CODS vC4
_Ki
Mr. Harold R. Trader Supervisor--Power Station Safety,
Allegheny Power System Bulk Power Supply Cabin Hill Greensburg, Pennsylvania 15601
Training,
and Security
Dear Mr. Trader:
',,
Here is the Chemical Safety Data Sheet (Allegheny Form C 23-038) you asked for on Vimasco Cable Coating No. 1-A.
Safety data for Vimasco Cable Coating No. 1 are substantially identical to those for Cable Coating No. 1-A. Cable Coating No. 1 was a predecessor product to Cable Coating No. 1-A and is no longer available commercially.
I^apologize for the fact that you had to call us a second time on this. The delay was my fault, but was not intentional.
Cordially,
William A. Pugh, Jr. Assistant to the President
WAP/sras
Enclosure: As noted