Document QJ5yqV0xMRX9VXqYXYG3wZjY8

American Society of Heating and Ventilating Engineers Guide, 1926-27 In order to carry out the principle of diffusion and get proper results from the unit system of ventilation, consideration must be given to the number, size, location and general application of the mechanical venti lators. With a correctly designed system and proper equipment, good diffusion will be effected if the frequency of air change in the room ventilated is equivalent to five or more volumes per hour but the extent to which the desirable effect of air motion is present will be governed both by the frequency of air change and the ceiling height. On the same principle that underlies the necessary distribution of direct radiation there is a-limit to the amount of air which can be dis tributed from a single point in ventilation work if good results are to be expected. Practical experiments seem to indicate that this limit is about 1500 cu. ft. per min. with this type of apparatus, for this reason mechanical unit ventilators are not built with capacities greater than 1500 cu. ft. pier min. and should never be used except in rooms with very high ceilings. In a practical way this determines the number of venti lators to be used in a given case. Where the very best results are desired it is recommended that the capacity of any single machine be limited to, 100 cu. ft. per min. per foot of ceiling height. Mechanical unit ventilators should be centrally located on the outside wall of the room which they serve. Corner locations are liable to result in inefficient and unbalanced distribution. In fact, under adverse con ditions, drafts may result from such a location. Unit ventilators may be recessed but they should never be enclosed or concealed. Not only are enclosures liable to affect the jet action but from a practical standpoint they interfere with proper care and attention by rendering the machine inaccessible. Moreover, there is a certain psychological value to an exposed machine. The occupants quickly learn its purpose and operation with the result that they appreciate its value and see that it is operated and properly cared for. No single mechanical unit ventilator should be made to serve more than one room by the extension of ducts from the outlet since this is contrary to all the basic principles of the system. Adjacent rooms, if not sufficient in size and importance to be equipped with individual ventilating systems probably do not require any ventilation. Where the total B.t.u. required for heating and ventilating is in excess of the rated capacity of the unit, the- unit must be supplemented by direct radiation. Otherwise, the unit can be used for both heating and ventilating without direct radiation. No special treatment of vent flues is required by this system, the vitiated air being discharged from the building in the same manner, as all other mechanical systems. It has been found that the best results have been obtained where the cross sectional area of the vent flue did not exceed 20 sq. in. per 100 cu. ft. of air. Industrial Service Unit heaters for industrial work consist of a heating element over which air is forced or drawn by means of a power driven fan which also distributed this heated air to the space to be heated. The area that can be served by one unit varies according tp the type of unit and the location 236 American Society of Heating and Ventilating Engineers Guide, 1926-27 of the unit within the building. If the unit could always be located in the center of the area, which is the most ideal location from a standpoint of distribution, then one unit would most generally be capable of heating an area from 50 ft. square up to an area 150 ft. square. Unit heaters may be divided into two classes: Namely, the Direct Fired Type and the Heating Coil Type. The Direct Fired Type is constructed very much along the lines of the pipeless furnace used in house heating and burns coal, coke, wood, oil or gas fuel. A power driven fan connected to the base of the heater creates Table 100. B.t.u. Constants for Various Steam Pressures and Temperatures of Entering Air Steam Pressure las. -10* 0* , 10 Temperature or Air Entering Heater 20" 30 40 45" 50* 55* 60 65 70 75" 0 0.975 0.93 0.89 0.84 0.80 0.76 0.73 0.71 0.69 0.67 0.64 0.62 0.60 2 1.01 0.96 0.92 0.87 0.83 0.79 0.76 0.74 0.72 0.70 0.68 0.65 0.63 5 1.04 1.00 0.96 0.91 0.87 0.82 0.80 0.78 0.76 0.74 0.71 0.69 0.67 10 1.06 1.05 1.01 0.97 0.92 0.88 0.85 0.83 0.81 0.79 0.76 0.74 0.72 IS 1.15 1.10 1.05 1.01 0.97 0.92 0.90 0.88 0.86 0.83 0.81 0.79 0.76 20 1.18 1.14 1.09 1.05 1.00 0.96 0.94 0.92 0.89 0.87 0.85 0.83 0.81 30 1.25 1.21 1.16 1.12 1.08 1.03 1.01 0.98 0.96 0.94 0.92 0.90 0.88 40 1.30 1.26 1.22 1.17 1.12 1.08 1.06 1.04 1.02 1.00 0.97 0.95 0.93 50 1.35 1.31 1.27 1.22 1.18 1.13 1.11 1.09 1.07 1.04 1.02 1.00 0.98 60 1.39 1.35 1.31 1.26 1.22 1.18 1.16 1.13 1.11 1.09 1.07 1.05 1.03 80 1.49 1.43 1.38 1.34 1.29 1.25 1.23 1.20 1.18 1.16 1.14 1.12 1.10 100 1.53 1.49 1.44 1.40 1.35 1.31 1.29 1.26 1.24 1.22 1.20 1.18 1.16 125 1.59 1.56 1.51 1.46 1.42 1.37 1.36 1.33 1.31 1.29 1.27 1.24 1.22 135 1.61 1.57 1.53 1.48 1.44 1.39 1.37 1.35 1.33 1.30 1.28 1.26 1.24 140 1.62 1.58 1.54 1.49 1.45 1.41 1.38 1.36 1.34 1.32 1.29 1.27 1.25 150 1.64 1.60 1.55 1.51 1.46 1.42 1.40 1.38 1.35 1.33 1.31 1.28 1.26 Note.--To get B.t.u.'s at any steam pressure and entering temperature, multiply constant from table by rated B.t.u.'s at 0 deg. entering and 5 lb. pressure. a rapid circulation of air over the cast iron heating surface provided in the fire box. The air thus heated is discharged into the building from an outlet on top of the heater. Generally this type is used where steam or hot water is not available and where it is not desired or practical to install a boiler plant. The Heating Coil Type unit heater consists of a bank of steam or hot water heating coils which may be made of steel pipe, cast iron, copper or brass over which air is blown or drawn by means of a power driven fan. The fan may be direct connected to the motor or pulley driven from motor or line shaft. This type Unit has two distinct classifications: Namely, the Horizontab and the Vertical types. The Horizontal type as a general rule uses a propeller or disk fan for passing the air over the heating surface. Cast iron and copper tube heating surface are in most cases used in this type unit. The fan and heater are built into a sheet metal casing and the direction of flow of air is regulated by means of sheet metal baffle plates. An advantage of the Horizontal Unit is'that it is comparatively light and can be suspended from columns or trusses of the building, thus conserving the floor space, 237