Document QJ51kBmQdrYrbmgpw4VJo9BJ5

Boilers, Cast-Iro Weil-McLain Company Manufacturing Division: Michigan City, Ind. and Erie, Pa. General Offices: 641 W. Lake Street, Chicago NEW YORK OFFICES: 501 Fifth Avenue Prompt Weil-McLain Boiler and Radiator service is made conveniently available through local stocks carried by Weil-MeUi Distributors in most of the Important distributing centers. LAln New AU-Fuel Boilers No. 67 and No. 77 Conversion type boilers with insulated enameled jacket. For hand or auto matic firing. Connected Load Ratings: Steam 300 to 950 sq ft, Water 480 to 1,520 sq ft. No. 78 Boiler for Automatic Firing Boiler has insulated en ameled de luxe jacket. Front or rear jacket ex tension available. Con nected Load Ratings: Steam 400 to 1,030 sq ft, Water 640 to 1,650 sq ft. "RO Series" Boiler for Automatic Firing Jacketed and insulated round boiler for small homes. Connected Load Ratings: Steam 420 and 520 sq ft, Water 630 and 790 sq ft. Square-Type Boilers Sectional boilers for larger installations. Com plete range .of sizes. Connected Load Ratings: Steam 650 to 9,300 sq ft, Water 1,050 to 14,900 sq ft. Self-Feed Boiler Magazine type boiler for small inexpensive sizes hard coal or coke. Con nected Load Ratings: Steam 240 to 785 sq ft, Water 385 to 1,260 sq ft. II I Junior Radiators Occupy 40 per cent less space than conventional radiators of same rating. 3-tiibe, 3% in. wide; 4- tube,4%e in. wide; 5-tube, 5% in. wide; 6-tube, in. wide. Concealed Raydiant Partially Recessed Cabinet Raydiant Raydiant is a convector type all cast iron radiator made , in Concealed, Partially Exposed and Cabinet Types. Raydiant Radiators, however, differ from conventional convectors in that they supply not only convected heat but also sun-like radiant warmth from their heat radiating "live" panel front. A second important advantage is their ability to hold heat longer^ This helps increase the comfort of (on and off) automatic heating and makes mixed installation of Raydiant and standard radiation practicable. 950 Boilers, Gas American Gas Products Division of American Radiator Company 40 West 40th Street, New York, N. Y. ~ TTiiTrs for Hot Water . . . Steam and Vapor Heating . . . Automatic Hot Water Storage Heaters . . . Air Conditioners . . . Gas Fired Steam Radiators Approved by A. G. A. Laboratory for Steam, Vapor or Hot Water Heating Systems. Ratings Below. Steam Boiler Number 0CS-4 0-GS-4-E 0-GS-5-E 0-GS-6.E 0-GS-7-E 0-GS-9-E 0-GS-I1-E IJGS-4 l-GS-5 l-GS-6 l-GS-7 t-GS-8 1-GS-y l-GS-10 l-GS-ll 4-GS-6 4-GS-7 4-GS-8 4CS-9 4-GS-10 4-GS-l 1 4-GS-I3 4-GS-15 4-GS-17 4-GS-I9 4-GS-2I 4-GS-22 4-GS-25 4CS-28 4-GS-31 4-GS-33 4-GS-37 4-GS-41 Empire Ideal Standard Ideal Specifications for Empire and Standard Ideal Gas Boilers STEAM BOILERS WATER BOILERS A.G.A. Steam Rating Sq. Ft. Supplies Sq. Ft. Direct C.I. Radiation No. and Size 1 of Tappings , Supply Return In. Water Boiler Number A.G.A. Water Rating Sq. Ft. Supplies Installed No. a of T* Gravity Accelerated. Supply In. 270 360 450 540 255 340 425 510 680 850 610 775 940 1105 1270 1435 1600 1765 2000 2400 2800 3200 3600 4000 4800 5600 6400 7200 8000 8400 9600 10800 12000 12800 14400 16000 171 2-2i/* 231 2-21/* 291 357 22--22''A 161 1-3 217 1-3 275 1-3 336 2-3 460 2-3 592 2-3 408 2-4 533 2-4 666 2-4 792 2-4 934 2-4 1055 2-4 1176 2-4 1298 2-4 1471 2-6 1765 ` 2-6 2059 2-6 2353 2-6 2647 2-6 2941 2-6 3529 4-6 4118 4-6 4706 4-6 5294 4-6 5882 4-6 6176 6-6 7059 6-6 7941 6-6 8824 6-6 9412 8-6 10588 8-6 11765 . 8-6 I-1'A, l-GA-4 1-l'A l-GA-5 1-1 /a ! l-GA-6 l-l'A l-GA-7 1-1'/? 2-GA-4 l-l'/z 2-GA-5 l-l'/l 1-11/2 l-l'/z i-iy* 2-GA-6 2-GA-7 4-GA-9 4-GA-l 1 2-4 4-GA-13 2-4 l-GW-4 2-4 l-GW-5 2-4 l-GW-6 2-4 l-GW-7 2-4 l-GW-8 2-4 I-GW-9 2-4 i-gw-io 2-5 1-GW-l 1 2-5 4-GW-6 2-5 4-GW-7 2-5 4-GW-8 2-5 4-GW-9 2-5 4^GW-10 3-5 4-GW-l 1 3-5 4-GW-I3 3-5 4-GW-J5 3-5 4-GW-l 7 3-5 4-CW-I9 4-5 4-GW-21 4-5 4-GW-22 4-5 4-GW-25 4-5 4-GW-28 5-5 4-GW-3I 5-5 ! 4-GW-33 5-5 | 4-GW-37 1 4-GW-41 210 280 350 420 .420 560 700 840 1120 1400 1680 980 1240 1500 1770 2030 2300 2560 2820 3200 3840 4480 5120 5760 6400 7680 8960 10240 11520 12800 13440 15360 17260 19200 20480 23040 25600 126 167 210 253 253 342 434 527 724 931 1149 624 810 1007 1222 1410 1597 1778 1958 m7 2667 3111 3555 4000 4444 5333 6222 7111 8000 8889 9333 10666 12000 13333 14222 16000 17778 >31 175 220 263 265 359 455 554 761 980 1215 656 853 1063 1294 1493 1691 1882 2074 2353 2824 3294 3765 4235 4706 5647 6588 7529 8471 9412 9882 11294 12706 14118 15059 16941 18824 2-1'/? 2-1'/? 2-1VS lift 1 -2Vi 2-lVl 2-2'/? l-l'/l 2-4 2-4 2-4 2-4 2-4 2-4 2-4 2-4 2-6 2-6 2-6 2-6 2-6 2-6 4-6 4-6 4-6 4-6 4-6 6--6 6-6 6-6 6*6 6-6 8-6 8-6 In. 2-Wi 2-Wi 2-Wi 2-11/2 I-2'A I-2V5 1-21/2 1-2'A 2t1<A 2-2'A 2-21/2 2-4 2-4 2-4 2-4 2-4 2-4 2-4 2-4 2-5 2-5 2-5 2-5 2-5 2-5 3-5 3-5 3-5 3-5 3-5 4-5 4-5 4-5 4-5 5-5 5-5 5-5 AH Boilers except Type 4-G and Nos. 1-GSor W-llare available in either Standard or Empire Ideal models. (See also Page 900) 951