Document QJ51kBmQdrYrbmgpw4VJo9BJ5
Boilers, Cast-Iro
Weil-McLain Company
Manufacturing Division: Michigan City, Ind. and Erie, Pa.
General Offices: 641 W. Lake Street, Chicago
NEW YORK OFFICES: 501 Fifth Avenue
Prompt Weil-McLain Boiler and Radiator service is made conveniently available through local stocks carried by Weil-MeUi
Distributors in most of the Important distributing centers.
LAln
New AU-Fuel Boilers No. 67 and No. 77
Conversion type boilers with insulated enameled jacket. For hand or auto matic firing. Connected Load Ratings: Steam 300 to 950 sq ft, Water 480 to 1,520 sq ft.
No. 78 Boiler for Automatic Firing
Boiler has insulated en ameled de luxe jacket. Front or rear jacket ex tension available. Con nected Load Ratings: Steam 400 to 1,030 sq ft, Water 640 to 1,650 sq ft.
"RO Series" Boiler for Automatic Firing
Jacketed and insulated round boiler for small homes. Connected Load Ratings: Steam 420 and 520 sq ft, Water 630 and 790 sq ft.
Square-Type Boilers
Sectional boilers for larger installations. Com
plete range .of sizes. Connected Load Ratings: Steam 650 to 9,300 sq ft,
Water 1,050 to 14,900 sq ft.
Self-Feed Boiler Magazine type boiler for small inexpensive sizes hard coal or coke. Con nected Load Ratings: Steam 240 to 785 sq ft, Water 385 to 1,260 sq ft.
II I
Junior Radiators Occupy 40 per cent less space than conventional radiators of same rating. 3-tiibe, 3% in. wide; 4-
tube,4%e in. wide; 5-tube, 5% in. wide; 6-tube, in. wide.
Concealed Raydiant
Partially Recessed
Cabinet Raydiant
Raydiant is a convector type all cast iron radiator made , in Concealed, Partially Exposed and Cabinet Types. Raydiant Radiators, however, differ from conventional
convectors in that they supply not only convected heat but also sun-like radiant warmth from their heat radiating "live" panel front. A second important advantage is their ability to hold heat longer^ This helps increase the comfort of (on and off) automatic
heating and makes mixed installation of Raydiant and standard radiation practicable.
950
Boilers, Gas
American Gas Products
Division of American Radiator Company
40 West 40th Street, New York, N. Y.
~ TTiiTrs for Hot Water . . . Steam and Vapor Heating . . . Automatic Hot Water Storage Heaters . . . Air Conditioners . . . Gas Fired Steam Radiators
Approved by A. G. A. Laboratory for Steam, Vapor
or Hot Water Heating Systems.
Ratings Below.
Steam Boiler Number
0CS-4
0-GS-4-E 0-GS-5-E 0-GS-6.E 0-GS-7-E 0-GS-9-E 0-GS-I1-E IJGS-4 l-GS-5 l-GS-6 l-GS-7 t-GS-8 1-GS-y l-GS-10 l-GS-ll 4-GS-6 4-GS-7 4-GS-8 4CS-9 4-GS-10 4-GS-l 1 4-GS-I3 4-GS-15 4-GS-17 4-GS-I9 4-GS-2I 4-GS-22 4-GS-25 4CS-28 4-GS-31 4-GS-33 4-GS-37 4-GS-41
Empire Ideal
Standard Ideal
Specifications for Empire and Standard Ideal Gas Boilers
STEAM BOILERS
WATER BOILERS
A.G.A. Steam Rating
Sq. Ft.
Supplies Sq. Ft. Direct
C.I.
Radiation
No. and Size 1 of Tappings ,
Supply Return In.
Water Boiler
Number
A.G.A. Water Rating
Sq. Ft.
Supplies Installed
No. a of T*
Gravity
Accelerated.
Supply In.
270 360 450 540 255 340 425 510 680
850 610 775
940 1105 1270
1435 1600
1765 2000
2400 2800
3200 3600 4000
4800 5600 6400 7200 8000 8400
9600 10800 12000 12800
14400 16000
171 2-2i/*
231 2-21/*
291 357
22--22''A
161 1-3
217 1-3
275 1-3
336 2-3
460 2-3
592 2-3
408 2-4
533 2-4
666 2-4
792 2-4
934 2-4
1055 2-4
1176 2-4
1298 2-4
1471 2-6
1765 ` 2-6
2059 2-6
2353 2-6
2647 2-6
2941 2-6
3529 4-6
4118 4-6
4706 4-6
5294 4-6
5882 4-6
6176 6-6
7059 6-6
7941 6-6
8824 6-6
9412 8-6
10588 8-6
11765 . 8-6
I-1'A, l-GA-4
1-l'A l-GA-5 1-1 /a ! l-GA-6 l-l'A l-GA-7 1-1'/? 2-GA-4 l-l'/z 2-GA-5
l-l'/l 1-11/2 l-l'/z i-iy*
2-GA-6 2-GA-7 4-GA-9
4-GA-l 1
2-4 4-GA-13
2-4 l-GW-4
2-4 l-GW-5
2-4 l-GW-6
2-4 l-GW-7
2-4 l-GW-8
2-4 I-GW-9
2-4 i-gw-io
2-5 1-GW-l 1
2-5 4-GW-6
2-5 4-GW-7
2-5 4-GW-8
2-5 4-GW-9
2-5 4^GW-10
3-5 4-GW-l 1
3-5 4-GW-I3
3-5 4-GW-J5
3-5 4-GW-l 7
3-5 4-CW-I9
4-5 4-GW-21
4-5 4-GW-22
4-5 4-GW-25
4-5 4-GW-28
5-5 4-GW-3I
5-5 ! 4-GW-33
5-5 | 4-GW-37
1 4-GW-41
210 280
350 420 .420 560 700 840
1120 1400 1680 980 1240 1500 1770 2030 2300 2560 2820
3200 3840
4480 5120
5760 6400 7680 8960 10240
11520 12800
13440 15360 17260 19200 20480
23040 25600
126 167
210 253
253 342
434 527
724 931 1149 624
810 1007
1222 1410 1597 1778 1958 m7
2667
3111 3555 4000 4444
5333 6222 7111 8000 8889
9333 10666
12000 13333 14222 16000 17778
>31
175 220
263
265 359 455 554 761 980
1215 656
853 1063
1294 1493 1691
1882 2074 2353
2824 3294 3765
4235 4706 5647 6588 7529 8471
9412 9882 11294
12706 14118
15059 16941
18824
2-1'/? 2-1'/?
2-1VS
lift 1 -2Vi
2-lVl 2-2'/? l-l'/l 2-4 2-4 2-4 2-4 2-4 2-4 2-4 2-4 2-6 2-6 2-6 2-6 2-6 2-6 4-6 4-6 4-6 4-6 4-6 6--6 6-6 6-6 6*6 6-6 8-6 8-6
In.
2-Wi 2-Wi 2-Wi 2-11/2 I-2'A I-2V5
1-21/2 1-2'A 2t1<A
2-2'A
2-21/2 2-4 2-4 2-4 2-4 2-4 2-4 2-4 2-4 2-5 2-5 2-5 2-5 2-5 2-5 3-5 3-5 3-5 3-5 3-5 4-5 4-5 4-5 4-5 5-5 5-5 5-5
AH Boilers except Type 4-G and Nos. 1-GSor W-llare available in either Standard or Empire Ideal models.
(See also Page 900)
951