FLUID-TITE. ASBESTOS-CEMENT TYPE 25, 75 and 125 IRRIGATION PIPE SPECIFICATIONS CTD010361 Certain-teed FlUID-TITE and CERTA-SPACER are istered regi trademarks of Certain-feed Products Corp., Ardmore, Pa STANDARD SPECIFICATIONS CERTAIN-TEED ASBESTOS-CEMENT TYPE 25, 75 AND 125 IRRIGATION PIPE SECTION 1 - GENERAL Sec. 1.1 Scope - This specification designates the requirements for Certain-teed FLUID-TITE Asbestos-Cement Irrigation Pipe, Types 25, 75 and 125, manufactured for use in irrigation supply lines and distribution systems which carry water under pressure. Sec. 1.2 Conformance - Certain-teed Irrigation Pipe, as manufactured to meet these specifications, meets the requirements of the U. S. Dept, of Agriculture, Soil Conservation Service Specification Guide 432 for Asbestos Cement Pipe. SECTION 2 - GENERAL REQUIREMENTS Sec. 2.1 Sizes -- Pipe shall be manufactured with nominal inside diameters of 3", 4", 6", 8", 10", 12", 14", 15", 16", 18", 20", 21", and 24" in Types 25, 75 and 125; 5" in Types 25 and 75. Sec. 2.2 Types - Certain-teed Irrigation Pipe, to meet these specifications, shall be manufactured in three types, for working pressures of 25, 75 and 125 psi. The types shall be designated as Type 25, Type 75 and Type 125. Sec. 2.3 Lengths - 2.3.1 The standard length of Irrigation Pipe shall be 13 feet in all classes and sizes. At least 90% of the total footage of any class and size, excluding short lengths, shall be of this length with a tolerance of plus zero or minus 1 inch. The re maining 10% or less may be in random lengths of not less than 7 feet, with a tolerance of plus or minus 1 inch. 2.3.2 Short Lengths -- Short lengths for use in making connections to valves, fittings, and structures, and for making closures shall not exceed 6 feet 6 inches. Stand ard lengths are Vi lengths (6' 6" 1") machined ends only (M.E.O.) and % lengths (3' 3" 1") fully machined (FM). Short lengths (includes), when not specified on the order, may be furnished as a maximum at factory option as fol lows : In sizes 3" through 12", 1% of total footage in % F.M. with one coupling for every two pieces and 1% in Vi M.E.O. with one coupling for each piece. ' In sizes 14" through 24", V% of total footage in % F.M. with one coupling for every two' pieces and l/l% in Vi M.E.O. with one coupling for each piece except that includes will be supplied in sizes 18" through 24" only on customer re quest at time of order. Vi F.M. with one coupling per piece may be substituted for % F.M. in sizes 8" through 16" on an equal percentage basis upon request. 1- - CTD010362 Sec. 2.4 Couplings - Couplings shall be of the FLU1D-TITE design, unless otherwise specified. They shall provide tight joints when subjected to the same hydrostatic test as desig nated for the pipe. One coupling of the same manufacture as the pipe shall be furnished with each standard and random length of pipe. It shall consist of an asbestos-cement sleeve and two rubber gaskets suitable for use with the particu lar size and class of pipe with which it is supplied. 2.4.1 CERTA-SPACER Band - Each end of a standard, random and M.E.O. pipe shall include a factory installed CERTA-SPACER to provide positive end separation without employing the sealing gasket for this function. Sec. 2.5 Materials - 2.5.1 2.5.2 2.5.3 Pipe and Couplings - Asbestos-Cement Irrigation Pipe and Couplings shall be composed of an intimate mixture of Portland cement, asbestos fiber and silica, and shall be free from organic additives. The material shall be formed under pressure and cured by autoclave process to meet the physical and chemical re quirements of the specification. Rubber Gaskets -- Rubber Sealing Gaskets shall conform to the requirements of ASTM-D-1869 latest issue and consist of a vulcanized rubber compound as speci fied by the manufacturer. CERTA-SPACER BAND - CERTA-SPACER Band shall consist of a special yielding synthetic compound as specified by the manufacturer. SECTION 3 - DETAIL REQUIREMENTS Sec. 3.1 Pipe - 3.3.1 Description -- Asbestos-Cement Irrigation Pipe shall be made to the manufacturer's standard dimensions and tolerances. The pipe shall be machined on each end to properly receive the coupling and gasket. 3.1.2 Hydrostatic Test -- Each standard, random or short length of pipe and each coupling for the corresponding pipe shall have sufficient strength to hold an in ternal hydrostatic test for each type of pipe equal to three times the working pressure of the pipe as shown in the following table, when tested as described in Section 4.2. TYPE OF PIPE TEST PRESSURE Type 25 75 psi Type 75 225 psi 3.1.3 Type 125 375 psi Flexural Strenath Each standard length of pipe in sizes 5", 4". 5". 6" and 8" shall have sufficient beam strength to withstand without failure the total ap plied load specified below when tested as described in Section 4.2.2. The fol lowing values are based on tests across a 12 foot span. 2- - CTD010363 TOTAL APPLIED LOADS - LBS. Nominal Diameter Inches Type 25 Type 75 Type 125 3" 225 375 4" 450 750 5" 675 1125 6" 975 1500 8" 1875 2775 565 975 2475 4500 Crushing Strength -- Each pipe w hen tested shall have sufficient stren submitted to the ASTM three-edg<e bearing test as spec ified in Section support not less than the loads indicated in the following tabulation: Nominal Diameter Inches MINIMUM CRUSHING STRENGTH Type 25 Type 75 Type 125 3" 1500 4" 1100 5" 1000 6" 1000 8" 1300 10" 1500 12" 1500 14" 1500 15" 1500 16" 1500 18" 1800 20" 2000 21" 2400 24" 2400 2300 1900 1650 1400 1650 1900 2200 2600 2600 2750 2900 3100 3300 3500 4400 4200 3700 4000 4300 4600 5000 5100 5400 5800 6400 6800 7500 3.1.5 Workmanship -- 3.1.5.1 Inside Surface -- Each pipe shall be free from bulges, dents, and tears on the inside surface which result in a variation in diameter greater than 3/16 from that obtained on adjacent unaffected portions of the surface. 3.1.5.2 Ends -- Machined ends of the pipe that receive the coupling shall be free from dents and gouges that will affect the tightness of the joint. 3.1.5.3 Straightness - Each pipe shall notvary from straightness more than 5/8 inch measured as an outside mid-ordinate, in lengths of 13 feet. Sec. 3.2 Couplings - Asbestos-Cement Couplings shall be machined on the inside surface so that the gaskets are retained in the proper position to make a tight seal. Sec. 3.3 Rubber Gaskets -- The rubber gaskets shall conform to the manufacturer's standards. Sec. 3.4 Chemical Requirements -- The Uncombined Calcium Hydroxide in Certain-teed AsbestosCement Irrigation Pipe and Couplings shall not be greater than 1 per cent when tested by the methods described in Section 4.2.4. 3- - CTD010364 SECTION 4 - INSPECTION TESTS AND REJECTIONS Sec. 4.1 General - All material furnished under this specification shall be inspected and tested in accordance with this specification. All material shall be in a normal processed condition prior to test for conformance to the requirements stated in previous sections. When requested on his order, the purchaser may witness inspection and test procedures at his own expense. In lieu of this witnessing, he may re quest the manufacturer to submit a certificate certifying the product meets the requirements of this specification. To insure the purchaser that all pipe pur chased under this specification conforms to the standards herein required and for the convenience of the purchaser or his representative, all tests must be con ducted in the Continental U. S. Sec. 4.2 Tests - 4.2.1 Hydrostatic Test -- Each standard, random, or short length of pipe, and each coupling shall be tested under the hydrostatic pressures outlined in Section 3.1.2. All air shall be expelled and the water pressure shall be increased to the test pressure at a uniform rate of not less than 100 p.s.i. per second. The specified test pressure shall be maintained for at least 5 seconds. Any pipe length or sleeve showing leakage, sweating or other defect shall be rejected. 4.2.2 Flexural Strength - Each standard length of pipe having a nominal diameter of 3", 4", 5", 6", or 8" shall be tested in flexure. The load is applied at a uni form rate of at least 250 lbs. per second until it equals the proof load specified. The load is distributed equally at the third points of the clear span and it is maintained for at least 5 seconds. 4.2.3 Crush ing - From each 300 lengths of pipe, or fraction thereof, of each size and class when specifically requested by the purchaser on his order, one length shall be selected by the inspector for a three-edge bearing test before shipment. From each selected length, there shall be cut one unmachined section of pipe one foot long. This section shall be tested by the ASTM three-edge bearing method and shall not fail until the total applied load exceeds the applicable value shown in Section 3.1.4. The rate of loading shall be 2,000 pounds per minute per lineal foot, with a tolerance of plus or minus 500 pounds per minute per Lineal foot. For this test, the two lower bearings shall consist of two straight wooden strips with vertical sides, each strip having its interior top edge rounded to a radius of approximately 1/2 inch. The strips shall be securely fastened to a rigid block, with the interior vertical faces parallel and clear space distance of 1/2 inch for pipe 12 inches and under and 1 inch for pipe 14 and 16 inches. The upper bearing shall be a rigid wooden block, at least 6 inches in cross section straight and true from end to end. The upper and lower bearings shall extend the full length of the test section. 4.2.4 Uncombined Colcium Hydroxide Test - The manufacturer shall conduct periodic controlled Uncombined Calcium Hydroxide tests. Upon request, certifications shall be issued to the customer that the pipe and couplings will conform to the requirements of maximum Uncombined Calcium Hydroxide permitted under 3-4. Reagents (a) Phenolphthalein Indicator - Dissolve 1.0 g of phenolphthalein in 100:0 ml. of absolute ethanol.* 4- CTD010365 (b) Glycerol - Ethanol Solvent -- Prepare a solution consisting of glycerol and anhydrous or absolute ethanol, *1:2 by volume. To each liter of this solution 2.0 ml. of the indicator is added. Adjust the solvent to slightly basic with either dilute NaOH in absolute ethanol* or standard ammonium acetate depend ing on the original pH. (c) Stondord Ammonium Acetote Solution -- (1 ml. - 0.005 g CaO). Dissolve 16.0 g. dry crystalline ammonium acetate in one liter of absolute or anhydrous ethanol.* The solution is standardized by following the analytical Procedure except chat 0.05 - 0.06 g. of pure ground CaO is substituted for the 1 g. sample. *Note: Specially denatured alcohol No. 30, 3a or 2b or alcohol consisting of 95% specially denatured alcohol No. 3a plus 5% isopropanol may be substituted. Procedure Representative samples of pipe or sleeves shall be prepared and immediately screened through a 20 mesh screen. Place the material passing through the screen immediately into a weighing boctle and cover wich its ground-glass cop. Place the boctle wich top removed, in a drying oven at 105C. for two hr., and then cool in a desiccator to room temperature. Weigh out 1 g. 0.010 g. of the dried sample from a pipe or sleeve to the nearest 0.001 g. and place it into a dry 250 ml. Erlenmeyer flask, to which a teflon encapsulated stirring bar, 60 ml. of the glycerol-ethanol solvent and 2.0 g. Sr. (NOj )2 are added. Attach the flask to a water-cooled condenser (with a standard 24/40 glass joint), and place on a hoc plate-magnetic stirrer. Boil the solution gently for 30 minutes with mild stirring. Then remove the flask and filter the mixture on a Buchner funnel under vacuum. Bring the filtrate to a boil and derate with the standard ized ammonium acetate reagent to a colorless endpoint. The endpoint is ob served by comparison with a similar mixture containing no phenolphthalein in dicator. No excess ammonium acetate should be added at any time because an excess may react with calcium silicates and aluminates. Calculations (a) Standardization of Ammonium Acetate Solution ^ W(CaO) X 1.32 E= Where E = weight of Ca (OH^ in g/ml. of ammonium acetate solution. W(CaO) = weight of CaO in grams. Va = volume of ammonium acetate in ml. fb) Percentage of Uncombined Ca(OH)2 %Ca(OH)2 =-Ep x 100 Where V = volume of ammonium acetace solution required by sample in ml. W =weight of sample in grams. 5- - CTD010366 Sec. 4.3 Rejection - 4.3.1 Crushing - Failure of the specimen tested for crushing strength to attain 75 per cent of the crushing load required in Section 3-1.4 shall be cause for rejec tion of the entire lot the test pipe prepresents. If any specimen tested for crushing strength supports more than 75 per cent but less than 100 per cent of the crushing load required in Section 3-1-4, one specimen shall be cut from each of two additional pipes of the same size and class manufactured during the same shift and shall be subjected to the crushing test. Failure of one of these addi tional specimens to meet the crushing strength requirements shall be cause for rejection of the entire lot of that size and class manufactured during the same shift as the test specimen. SECTION 5 - MARKING Section 5.1 Pipe -- Each standard, random and short length of pipe shall be clearly marked on the outside surface with the trade name, pipe size, type designation, date of manu facture and test pressure or maximum working pressure. Sec. 5.2 Coupling -- Each coupling shall be clearly marked with the trade name, type and size of pipe for which it is intended to be used, and the letter ,T" to indicate that it has been tested. Sec. 5.3 Goskets -- Each rubber gasket shall be marked with the manufacturers identification, the size and year of manufacture. Sec. 5.4 Additional Marking -- When factory inspection is made by the purchaser, each pipe and each coupling may receive an additional special marking of no more than three letters, as required by the purchaser. SECTION 6 - PREPARATION FOR SHIPMENT Sec. 6.1 General - All pipe, couplings and gaskets shall, unless otherwise specified, be prepared for standard commercial shipment, so as to insure acceptance by common or other carriers. SECTION 7 - SUPPLEMENTARY DETAILS TO BE PROVIDED BY PURCHASER Sec. 7.1 General -- When purchasing Irrigation Pipe under these specifications, it will be neces sary for the purchaser to make specific statements for each lot of pipe. Sec. 7.2 Size - The purchaser shall state the pipe size or sizes required. Sec. 7.3 Types - The purchaser shall state the type or types of pipe required. Sec. 7.4 Standard Lengths -- The purchaser shall state the total footage of 13 ft. lengths required. Sec. 7.5 Short Lengths -- The purchaser shall state the total footage of 6 ft. 6 inch and 3 ft. 3 inch lengths required. Sec. 7.6 Inspection & Tests - 7.6.1 Crushing Tests -- The purchaser shaLl stace on his order when crushing tests are required. 6- - CTD010367 7.6.2 Uncombined Calcium Hydroxide Tests -- The purchaser shall state on his order when the Uncombined Calcium Hydroxide Test is required. 7.6.3 Certificote of Tests - The purchaser shall state on his order when a certificate of tests in lieu of inspection is required. Sec. 7.7 Definitions -- Under these specifications the following definitions will apply: 7.7.1 Purchaser -- The person, firm, corporation or governmental sub-division entering into a contract or agreement to purchase pipe according to these specifications. 7.7.2 Monufacturer -- The person, firm or corporation who manufactures the pipe. 7.7.3 Inspector -- The representative of the purchaser, properly authorized and limited by the duties entrusted to him. 7.7.4 Working Pressure -- The maximum hydrostatic pressure to which the pipe will be subjected after installation, exclusive of allowance for water hammer. - t- CTD010368 DIMENSIONS & TOLERANCES ASBESTOS-CEMENT FLUID-TITE TYPE 25, 75, 125 IRRIGATION PIPE & COUPLINGS TOLERANCES PIPE 001 & 0D2 3" - IS" 0.020" 18" - 24" 0.030" COUPLING ID (B) 3" - 16" .025" 18" - 24" .040" PIPE SIZE TYPE 25 3 4 5 6 a 10 12 14 15 16 18 20 21 24 TYPE 75 3 4 5 6 8 10 12 14 15 16 18 20 21 24 B.O.D. INCHES 3,99 5.05 5.91 6.91 9.05 11.14 13.24 15.32 16.45 17.48 19.60 21.66 22.74 26.00 3.99 5.05 5.91 6.91 9.05 11.14 13.24 15.32 16.45 17.48 19.60 21.66 22.74 26.00 PIPE I.D. INCHES O.D. i INCHES O.D.2 INCHES 3.00 4.00 5.00 6.00 8.00 10.00 12.00 14.00 15.00 16.00 18.00 20.00 21.00 24.00 3.00 4.00 5.00 6.00 8.00 10.00 12.00 14.00 15.00 16.00 18.00 20.00 21.00 24.00 3.74 4.70 5.68 6.66 8.80 10.89 12.99 15.07 16.11 17.15 19.23 21.29 22.37 25.51 3.74 4.70 5.68 6.66 8.80 10.89 12.99 15.07 16.11 17.15 19.23 21.29 22.37 25.51 3.90 4.86 5.84 6.82 8.96 11.05 13.15 15.23 16.38 17.31 19.39 21.45 22.64 25.67 3.90 4.86 5.84 6.82 8.96 11.05 13.15 15.23 16.38 17.31 19.39 21.45 22.64 25.67 c 1/16 INCHES 2.60 2.55 2.58 2.58 2.97 3.07 3.07 3.63 4.31 3.63 4.38 4.38 5.27 4.38 2.60 2.55 2.58 2.58 2.97 3.07 3.07 3.63 4.31 3.63 4.38 4.38 5.27 4.38 COUPLINGS B(I.D.) INCHES L + .25 -.00 B.O.D. 3.850 4.790 5.750 6.750 8.890 11.000 13.100 15.190 16.225 17.270 19.410 21.470 22.500 25.690 3.850 4.790 5.750 6.750 8.890 11.000 13.100 15.190 16.225 17.270 19.410 21.470 22.500 25.690 6.25 6.00 5.75 5.75 6.50 6.75 7.00 7.50 8.50 7.50 10.00 10.00 10.50 10.00 6.25 6.00 5.75 5.75 6.50 6.75 7.00 7.50 8.50 7.50 10.00 10.00 10.50 10.00 5.35 6.19 7.12 8.18 10.50 12.75 15.00 17.15 18.26 19.31 21.52 23.76 24.96 28.22 5.35 6.19 7.12 8.18 10.50 12.75 15.00 17.15 18.26 19.31 21.52 23.76 24.96 28.22 8- - CTD010369 tolerances PIPE OP1 & OD2 3" - 16" i 0.020" 18" - 24" + 0.030" COUPLING ID (B) 3" - 16" i .025" 18" - 24" .040" PIPE SIZE B.O.D. INCHES TYPE 125 3 4 6 8. 10 12 14 15 16 18 20 21 24 4.06 5.08 7.16 9.36 11.39 13-57 15.36 17.02 17.48 20.28 22.50 23.70 26.86 PIPE I.O. INCHES O.D.1 INCHES 0.D.2 INCHES 3.00 4.00 6.00 8.00 10.00 12.00 13.60 15.00 15.50 18.00 20.00 21.00 24.00 3.74 4.64 6.91 9.11 11.14 13.32 15.07 16.68 17.15 19.90 22.12 23.28 26.48 3.90 4.80 7.07 9.27 11.30 13.48 15.23 16.95 17.31 20.06 22.28 23.55 26.64 C 1/16 INCHES 2.60 2.90 2.90 3.40 3.40 3.50 4.00 4.31 4.00 4.88 4.88 5.27 4.88 COUPLINGS B(I.D.) INCHES L + .25 -.00 B.O.D, 3.850 4.75S 7.025 9.230 11.260 13.440 15.205 16.795 17.285 20.080 22.300 23.410 26.660 6.25 6.50 6.50 7.50 7.50 7.75 9.00 9.00 9.00 11.10 11.10 11.10 11.10 5.35 6.47 8.76 11.22 13.27 15.64 17.70 19.33 19.96 23.24 25.66 26.45 30.40 NOTE: All above dimensions ore subject to manufacturing tolerances, The 15" and 21" coupling is of different design than shown* 9- - CTD010370 DISTRICT OFFICES ATLANTA PIPE DISTRICT Suite 1132, Lenox Towers 3272 Peachtree Road, N. E. Atlanta, Georgia 30326 Area Code 404 Telephone: 237-6331, 6332 CLEVELAND PIPE DISTRICT Suite 110, One Commerce Park Square 23200 Chagrin Boulevard (Beachwood) Cleveland, Ohio 44122 Area Code 216 Telephone: 464-8060 DENVER PIPE DISTRICT Suite 4G, Bankers Union Life Building 2401 E. Second Avenue P. 0, Box 6285 Denver, Colorado 80206 Area Code 303 Telephone: 388-5751 Area Code 713 HOUSTON PIPE DISTRICT Texas Gas Building Suite 275 2472 Bolsover Road P. 0. Box 25185 Houston, Texas 77005 Telephone: JAckson 6-1037, 3717 LOS ANGELES PIPE DISTRICT California Federal Savings Bldg., Suite 242 1695 Crescent Avenue Anaheim, California 92801 Area Code 714 Telephone: 774-3900 From Los Angeles: 213-625-1915 Phoenix Branch Office Suite 206 3625 No. 16th Street Phoenix, Arizona 85016 Area Code 602 Telephone: 274-3642 PHILADELPHIA PIPE DISTRICT Maple & Wissahickon Avenues Ambler, Pennsylvania 19002 Area Code 215 Telephone: 646-9350 Area Code 314 ST. LOUIS PIPE DISTRICT Suite 110 12015 Manchester Road (Des Peres) St. Louis, Missouri 63131 Telephone: YOrktown 6-3010 SAN FRANCISCO PIPE DISTRICT Second Floor Marina Building 77 Jack London Square Oakland, California 94607 Area Code 415 Telephone: 444-4022 AP-25-IRR 5/67 CER1AINTEED CTD010371 CERTAIN-TEED PRODUCTS CORPORATION, Ambler, Pennsylvania 19002 PRINTED IN U.S.Ai