Document Q8Zg3VMwma850areEmgq0O95

12-27-69 No. 69-2180 QUANTITATIVE EVALUATION OF CHROMATOGRAMS BY DIGITAL COMPUTERS Frederick Baumann, Edward Herlicska, Arthur C. Brown (Varian Aerograph, 2700 Mitchell Drive, Walnut Creek, Calif. 94598) and John Blesch (Varian Associates, 611 Hansen Way, Palo Alto, Calif. 94304) J. Chromatog. Sci. 7_ No. 680-84 (Nov. 1969). Presented at 5th Intern. Symp. on Advances in Chromatog., Las Vegas, Nevada, Jan. 20-23, 1969 Quant. GC with computers depends fundamentally on the accuracy of peak area measurements. In this invest, of the accuracy of area recovery by on-line digital computers, the influence of scan rate, data smoothing, peak detection and baseline recovery was detd. A Varian-Data Machines 620/i computer with an 8K 16-bit memory and cycle time of 1.8 microseconds was used. Peak detection and baseline correction methods are described which due to the inherent flexibility of the computer can be systematically changed to match the conditions during an isothermal chromatog. analysis. 2180 12-27-69 No. 69-2181 GAS CHROMATOGRAPHIC ANALYSIS OF REACTIVE GASES IN AIR ' R. M. Bethea and M. C. Meador* (Chem. Eng. Dept., Texas Technol. Coll., ( V \. Lubbock, Texas) (*Present address: Celanese Chemical Co., Pampa, Texas) J. Chromatog. Sci. No. 11: 655-64 (Nov. 1969). Presented in part at 1969 Pittsburgh Conf. on Anal. Chem. and Appl. Spectry. , Cleveland, Ohio, March 5, 1969 2181 / ' The authors reviewed the literature for cols, which have been used for qual. sepn. of reactive (NO, N02 S02 HC1, H2S, Cl2, NH^) and other gases (C02, N20) in air. They selected 21 cols, for further evaluation, criteria being that peak shapes should be suitable for qual. analysis of several of the project gases and that the col. be useful for quant. analysis in concns. below 100 ppm. A Varian Aerograph Model 1520-B dual col., dual detector (TCD) GC was used in the screening program. A two section col. of Porapak Q and Porapak R adequately sepd. NO and air. The air-N20-C02 sepn. was best on a QF--1 Fluoro col. H2S, Cl2 and S02 could be analyzed either on silicone oils SF--96 or triacetin. These cols, also effectively sepd. air--C02--NH^. N02 was well sepd. on Kel--F 90 grease and Fluorolube HG 1200 cols. #Retention data: Tabulated, p. 660 12-27-69 No. 69-2182 DIRECT GAS CHROMATOGRAPHIC. DETERMINATION OF DIETHYL CARBONATE IN WINE G. Brandenburg and K. Rohleder (Staat. Chem. Untersuchungsamt, Braunschweig, Germany) Deut. Lebensm. Rundschau 4, No. 3: 71-73 (1968) [In German] The sample is injected directly onto a precol., 17 cm x 3 ram, contg. SE-30, 1%, on Chromosorb G, a.w., DMCS, 80-100 mesh,, operated at 160C. The volatilized diethyl carbonate then passes to the GC col. for analysis. The error is within +6%. ,|II..1H ' ILIJ. ' "UVL. l. UlUHUr.!!^.*'M I lU-i.! .Mill " II. ' _. DSW 298101 59- STLCOPCB4068012