Memorandum on Inspection of Lowe Bros. Plant ^-13-46
She paint and varnish mixing and blending plants
of the Lowe Bros* Company, L'&yton, were inspected on 3-18-46.
Of particular Interest were certain portions of the plant
on which comments are made below.
.
In the mixing room on the 5th floor of Building #4
local exhaust ventilation had been installed since the
previous inspection in 1^40 This consists essentially cf
exhaust ducts ,bn. each- mixer, at the side of the machine .
opposite the operator, with the opening of the- duct- 'extending
roughly, one-third of the way about, the circumference of the
top of tne rsachih'-. Luring the operation of adding the dry
pigments to the mixer, most of the visible oust appeared to
enter these ducts. There was considerable accumulation of
dry pigments on the', wooden -floor, a n d -the janitor was, observed
to be sweeping up some ;dry freshly spilled''-matrials. This
woe confirmed by our- informants as-- the routine method of.'
handling such spills. A visible but thin accumulation of
unite powdered- dust was observed on the top of the ventilating
ducts and other equipment, our informants were unable to.
state whether this equipment had been washed down since'it had
been installed,
, '
.
The amount of lead as white lead added to the various
paint mixes was said to vary between aero and 5 7 0 pounds
per batch. The method of handling this lead pigment was
not seen. The observer was informed that the pigment came
in drums, and was scooped out by hand, weighed, and then
Kg'
..Jk.
added by hand scoop t o t h e final mix. Whether this pigment
.
* '.
. '
`
.d
was usually a dry powuen, or ground In oil as outlined by
J. J. Poppe, was not determined. Apparently the principal
lead mixers were isolated In the southeast corner of the
room.
The operation of unloading the freight cars of
lead pigments was not observed.
In the lacquer plant obvious precautions against
the potential fire .hazard had bean taken. The observer
was Informed.that the only health'hazard of practical: moment
to the men -known to the building foreman was that new men
were occasionally overcome by fuses m e n working unnecessarily
close to the mixing yats. The h e a t i n g 'of the mixing room
was accomplished -'by':.forced' -ventilation, the fresh air being
blown in from the floor, and the exhaust -air pulled out at.
the ceiling. There was no local exhaust ventilation'around
hue mixing vats.
.
The pump room in the basement had an exhaust
duct connected to each pump. There seemed to be no general
ventilation-of this room, where the odor of volatile solvents
was quite strong. There was no reason for men to work
routinely in this room. The protection of maintenance- hen
who repaired the pumps in oasa of leakage, and the entry of
a night watchman into this room In case of leakage, presented
apparent hazards. The methods used to protect the men in
aueh situations were not clear.
The solvent storage room presented a problem
similar to that of the pump room,
i
-5-
The principal problem of the varnish makers seemed
to be the occasional development of malodorous fume dependent
upon meteorological'conditions. The operators who added
.
various solvents in conformity with the formulae used in
making the varnishes and lacquers carried out this operation
In a large open vat. This vat was situated in a room with
a low ceiling, in which only natural ventilation was employed.
A cooling coil was noted which was said to be lowered over
the vat while the solvents were being mixed, in order to
condense the fume and thus minimise loss due to evaporation.
This mixing operation was not observed,
V /'...
'A', similar:' vat -in which-paint remover was compounded, "
was situated within this room but was isolated from the
others* The observer was informed that this remover contained V
20% benzol "and 11% e thylene dlchloride b y weight .
Conclusions
`
~
.,
A code prescribing the requirements for industrial
health in the State of Ohio has been adopted recently. Under
the provision of this code the limits of safety for exposure
of workmen to many industrial chemicals have been prescribed.
This code requires that the employer should know and control
the concentration of the vapors, dusts, mists, etc* of harmful
compounds within safe limits.
In order to assure Low Bros,'-'that they are operating
within these prescribed limits, and that they are adequately
protecting the health of their workmen, the following
specific recommendations are being made$
:
1 Air sampling representative of the range of
the fume and dust hazard, under operating conditions should
be done by a qualified industrial hygienist,
2* Tnls sampling should include the determination of
a) the lead content of the air in the vicinity
of the lead mixers ana railroad car unloading
.operations#
'.
.
b) the lead content of the dust in these areas,
e) the concentrations of volatile solvent at
breathing level near the lacquer mixers#
in the pump room# in the solvent storage
room# and in the solvent mixing room.
5* Analysis of the blood and urine of representative
men exposed to lead dust# for their lead content,
4 Clinical examination and investigation of
the possible occurrence of liver damage or blood destruction,
on tbs part oT the operators and maintenance men exposed to
ethylene dichloride and benzol,-
It seems probable that recommendations regarding changes in engineering design of certain of the operations and periodic examination of certain of the workmen, will follow such a study.
Plant inspection and memorandum byj Henry W. Ryder# M,D,
Report approved bys
Dates March 2 5# 1^4^