Document Q2dG90p6Y5dGMr0Oe4GnxKQ6

L. ^A x *--J> SU. UJ Of (/) ESIH/ESC__________ (Co.yDlv./Ofpt./location REPORT NO.: JOB/PROJECT NO.: DATE: TITLE: AUTHORS: ABSTRACT: SAMPLING ANALYSIS (Type of Report) MSI-7452 ESC-UAG-B7-162 760.28-7642 December 15, 1987 :k i c. v d -:3 oinu - .. ,u,r sr. Louie ANALYSIS OF ONE RESEARCH SAFETY SAMPLE FOR PC8S. B. M. Hughe*. D. E. McKenzie and L. R. Minor One oil saaiple was analyzed for PCS* for Research Safety. This saaipla was analyzed In order to assist personnel with the detenalnatlon of proper disposal methodology. The saaiple was analyzed In duplicate. In both analyses Aroclor 1242 was detected at 3 ug/g. Analyses were conducted with a Level of Detection of 1 ug/9. TECHNICAL APPROVAL: p. L. snermetr Environmental Sciences Center Sr, Research Group Leader APPROVAL BY: Ckx^roLt fTl- J. V. Lee Environmental Sciences Center QC/qA and &P Supervisor APPROVAL DATE: >3, l<m i COMPANY CONFIDENTIAL Thu document la tha proparty of Monoanto Company and tha racipiant i* raaponaibla for ita aafakaepmg and deposition It contain* CONFIDENTIAL INFORMATION which muit not bo raproduced, revaalad to unauthornad paraona or aant outaida tha Company without proper authorization MONS 221068 DISTRIBUTION COPY number abstract only S. L- Emery A. M. Ford 8. M. Hughes J. M. Lee D. E. McKenzie R. Parson Reports Library - E2NP - U4E - U4E - U4D - U4F - W1A - R2C T. F. Evans - A3NA P. L. Sherman - U1F A. F. Uelner - A3NF ft 19M(C> COMPANY CONFIDENTIAL When no longer needed, or upon request, return this report to HONS 221069 Time Stamp * <871217.1652> ANALYSIS REPORT DATE: DECEMBER IS, 1987 LOC NUMBER- U-87-11-10-01 PROJECT NO: 760.28-7642 TO. Randy Parson (VIA) FROM: Environmental Sciences Center Monsanto Company 800 N. Lindbergh Blvd. St. Louis, Mo. 63167 Phone No: (314) 694-1464 Title: Analysis of One Research Safety Saaple for PCB5 ABSTRACT One oil saaple was analyzed for PCBs for Research Safety. This saaple was analyzed In order to assist personnel with the deteralnatlon of proper disposal methodology. The saaple waa analyzed In duplicate. In both analysea Aroclor 1242 was detected at 3 ug/g. Analyses were conducted with a Level of Detection of 1 ug/g. INTRODUCTION Tha saaple was analyzed using Standard Extraction Method PCEX02 and Standard Analysis Method ICAM06. Summaries of these methods are given In a later sec tion of this report. Calculations were performed using internal standard method of calculation. Results of these analyses are given in Table 1. SUMMARY Duplleata analyala shewed that Aroclor 1242 was prepsent In the oil at e level of 3 ug/g. All analyses wars conducted with a level of detection (LOD) of 1 ug/g. Results of analyses ere given In Table 1. (continued) HONS 221070 QC RXSULTS The oil aaaple waa analyzed with a LOO of 1 ug/g which waa determined by jplklng cha oil with a known amount of Aroclor 1260 Aroelor 1260 waa addad Co cha aaaple ac lavala eorreapondlng co 1 and 10 ug/g, Recoverla* were calculaead and vara raapaccivaly. for low and high laval addition*. 131 and 127%, raapaccivaly. Summer lea of racovary daca ara llacad In Tabla 2. Thaaa raaulca IndlcaCa that If tha oil aaaplaa contalnad PCBa abova cha LOO chay would hava baan quantIflabia. Tha eaclmated accuracy of thaaa analyaaa ara on cha ordar of +/* 30%. DETAILS Standard Sampling Mathod No(a): N.A. Standard Extraction Mathod No(a): PCEX02 (Saa alao flow ahaat PCFS02) Standard Analyala Mathod No(s): ECANO6 (Saa alao ECFS06) Sample Idantlflcatlon(a): Hydraulic Fluid* C Bldg Elavator Final Report File No(a): RA7642 Tabla Flla No(a): TA7642.TB7642 Alao Included In this report ara: (1) Brief deacrlptlona of Standard Extraction and Analyala Mathoda (2) Extraction detalla for all aaaplaa. (3) Chain of Cuatody and Login Information, (4) Analytical Requeet Information generatad at Login. (5) Important terminology uaad in Quality Aaaurence/Quality Control, Analyte Extraction, and Inatrunantal Analyala. ANALYST(S): B. Maaon Hughea. La Shawn R. Minor, and David E. McKenzie ANALYST APPROVAL: MOMS 221071 Table 1. Results of capillary GC/EC analyses of Research Safety Ssap las Using Standard Analysis Method PCEX02, ESC Project No: 760,28 7642 Data DECEMBER 15.1987 SAMPLE 1 D. HYDRAULIC FLUIO-C bldg ELEVATOR HYDRAULIC FLUID*C BLOC elevator (dup) METHOD BLANK EXTRACT a LOD(a) (UC/C) concentrations AROCLOR 1242 DETECTED(UC/C) PCB-2258 1 3 PCB-2259 l 3 PCB-2260 1 NO (b) Footnotes: a. LCD- Hale of detection b. ND- No Aroclor foraulstlons detected above the specified Llalt of Detection (1.0 ug/g). TABLE FILE NO: TA742:LM ANALYST(3): B.M. Hughe*. D.E. McKenzie. and L.R. Minor ANALYST APPROVAEy //Y ________ MONS 221072 Table 2. Suoniry of Aroclor 1260 Spiking Concentrations and Recoveries In Research Safety Saaplas ESC Project No: 760.26 7642 SAMPLE ID extract number Data: DECEMBER 15.1987 AMOUNT ADDED (ug/g) RECOVERY <> HYDRAULIC FLUID-C BLDG + LOW SPIKE PCB-2256 1 HYDRAULIC FLUID-C BLDC + HIGH SPIKE PCB-2258 10 TABLE FILE NO: TB7642.LK ANALYST(S): B.M.Hugha^J^ E, McKanzla, and L*R. Minor rrv ANALYST APPROVAlf [ jj[ 131 127 HONS 221073 Tha following pagaa daacrlba Standard Sampling, Extraction, and/or Analytla Hathoda uaad for chla projact. MOMS 221074 FLOW SHEET PCFSQ2 FOE ESC EXTRACTION METHOD FCEX02 SAMPLE ID: EXTRACTION DATE and TIME: SAMPLE COLOR AND DESCRIPTION WEIGH OUT SAMPLE INTO A 14 OR 40 nL PIERCE VIAL (] SURROGATE SPIKE OF SAMPLE . (] MRC EXTRACT * LOC NO: FINAL WEIGHT INITIAL WEIGHT SAMPLE WEIGHT ............................. ADD 10 *L BENZENE TO SAMPLE. . [] ULTRASONICATI SAMPLE FOR 1/2 HOUR IN A SOUND BATH. (] . PUCE I bL OF THE EXTRACT INTO A I 1/2 L VIAL FOR ANALYSIS. . [] . NITROGEN BLOW DOWN IF REQUIRED t] EXTRACT NO: .............. OATE/TIME COMPLETED ANALYST: ..................... ESC JOB NO: ............ FINAL VOLUME................................aL MOMS 221075 ESC Standard Extraction Mathod (SEN) TITLE: PCBa In Non-EC Actlwa Hatrlcaa ESC Standard Extraction Mathod No FCEX02 MATRI(X),(CES): So11a and othar non*EC aetlva aollda and aolvanta TYPICAL SAMPLE SIZE (*) TYPICAL EXTRACT VOLUME (1) TYPICAL ANALYTES: Aroclora 1232, 1242, 1248. 1234, 1260, 1262. aonochloroblphanyl laoaara through dacaehloroblphanyl 0.5 5.0 10 ESC Standard Analyala Mathod Nos ECAN01, ICAN02, MSAN03 .MSAN06. M5AN23 INTERFERENCES: Any alactron capturing apaclaa In tha ratantlon tlaa raglon of trlchloroblphanyl laoaara through octachloroblphanyi laoaara. TYPICAL SURROGATES TYPICAL RECOVERIES (*) pantachlorobanxana 2.4.6*trichloro- blphanyl 50 - 120 50 - 120 APPARATUS AND MATERIALS: Burdick and Jackaon banxana or haxana for aaatpla axtractlon or dilution Ultraaonlc bath. Nltrogan for axtract voluaa raductlon. Dlapoaabla glaaawmra. (Saa flow ahaae for thla axtractIon aathod In PCFS02.I LIMITATIONS: Mathod appllaa only to aatrlcaa which do not contain Intarfarlng alactron capturing apaclaa In tha trlchloroblphanyl through oetmchloroblphanyl laoaar ratantlon tlaa raglon for EC analyaaa. Whan Intarfarancaa ara praaanc, a aaaa apaccroaatrle inacruaantal analyala aathod ahould ba utad. SAFETY PRECAUTIONS: Saa PCB handling protocol# In laboratory aafaty aanual. DATES OF METHOD CREATION AND UPDATES: 10/31/S3, 2/3/B4, 10/5/B4 HONS 221076 FLOW SHEET ECFS06 FOR ESC ANALYSIS METHOD ECAN08 EXTRACT ID: ESC EXTRACT * LOG NO: EC LOGBOOK PACE NUMBER: EXTRACT COLOR AND DESCRIPTION PLACE 150 uL EXTRACT OR AROCLOR STANDARD. AND 150 uL INTERNAL STANDARD SOLUTION CONTAIN- [ ] INC 0.04 ug/aL CL6-BENZENE . IN A 1.6 mL AUTOSAMPLER . VIAL. . PUCE VIAL IN AUTOSAMPLER TRAY OF HP*5880. RECORD ELECTRON CAPTURE AND GAS CHROMATOGRAPHIC OPERATING PARAMETERS AND 3357-LAS FILE INFORMATION IN INSTRUMENT LOGBOOK. (j . [] . INTERNAL STANDARD CALCULATION DETERMINE WHETHER TO USE INTERNAL OR EXTERNAL QUANTITATION METHODOLOGY. INTERNAL QUANTITATION IS PREFERED. . .[] BUT CAN NOT ALWAYS BE USED . DUE TO INTERFERENCES. [ ] CALCULATE CONCENTRATION OF AROCLOR FORMULATION AVERAGING THE VALUES DETERMINED FOR THE 10 * 30 PCS CONGENERS. USINC THE APPROPRIATE METHOD OF CALCULATION LISTED BELOW RRF - Ralativa Raaponsa Factor (conganar araa In Aroclor standard) (CL6-bansana araa)(Aroclor concantraclon) Aroclor Concantraclon (conganar araa) (CL6-banxane araa) (RRP) THESE EQUATIONS ASSUME THAT THE SAME AMOUNT OF INTERNAL STANDARD IS ADDED TO EXTRACTS AND STANDARDS EXTERNAL STANDARD CALCULATION Aroolor Concantratlon - (conganar araa)/(RF) RP - Raaponsa Factor - (conganar araa In Aroclor Standard)/(Aroclor Concan tratlon) Both above calculations ara performed for 10 30 PCB conganar* and tha valuas avaragad to yiald an avaraga Aroclor formulation concantratlon. Both methods ara also corractad for dilution by multiplying tha avaraga concantratlon by (Extract Volume)/(Sample Amount). MS FILE NUMBER: ................................ DATE/TIME COMPLETED ............................... / ANALYST: ...................................................... ESC JOB NO: ............................................... MOMS 221077 ESC Standard Analysis Method (SAM) TITLE: Aroclor Formulations In Solvants ESC Standard Analysis Method Mo ECAN06 ANALYTICAL INSTRUMENT AND MODE OF OPERATION' HP-5880 Capillary CC/EC inter faced to an HP-3357-LAS Laboratory Data System TYPICAL ANALYTE TYPICAL INSTRUMENT LEVEL OF DETECTION (LOD) (ug/ml) Aroclor formulations 1232, 1242. 1248. 1254, 1260. and 1262 0.1 TYPICAL PRECISION 9 10X LOD <*) 30 TYPICAL ACCURACY 9 10X LOD (*) 30 INTERFERENCES AND LIMITATIONS: Any electron capturing species in the reten tion time region of trlchloroblphenyl through octachlorobiphenyl congeners are potential interferences. Exact retention times of most likely PCB con geners can be obtained from the analysis of Aroclors 1248, 1254, and 1260. CHROMATOGRAPHIC COLUMN: 23 a fused silica Ue Scientific SB-30 (0.23 uM) with (0.32 mm ID) COLUMN TEMPERATURE PROGRAM: l30(l)/5/300 INJECTION TYPE: Splitless CALIBRATION AND STANDARDIZATION: Use internal or external standard quantita tion technique and calibrate instrument response factors from authentic Aroclor standards. Use a minimum of 10 PCB congeners for the determination of formulation identity and quantity. The external standard quantitation techni que is used when chromatographic lnterferents are present in the retention time region of the Internal standard. CALCULATIONS: Internal Standard Method (Aroclor Congener Area) Formulation concentration - ................................................................ (RRP)(Internal Standard Area) (Aroclor Congener Area) RRF - Relative Response Factor - ....................................................................................... (Internal Standard Area)(Aroclor Concen tration) External Standard Method Formulation concentration - (Aroclor Congener Area)/(RF) RF - Response Factor - (Aroclor Congener Aree in Standard)/(Standard Concen tration) The above formulation concentration calculations are performed for 10 - 30 PCB congeners and the values averaged to yield en average Aroclor formulation concentration. Both method concentrations are corrected for dilution by multiplying the average concentrations by (Extract Volume)/(Sampla Amount). SAFETY PRECAUTIONS: See PCB handling protocols in laboratory safety manual. DATE OF METHOD CREATION; 12/05/87 Time Stamp - <871216.1328> *0$ 221078 Tht following page* thow attraction dataila for aaaplaa aaaoclatad with this projact. HONS 221079 PLOW SHEET PCFS02 FOR ESC EXTRACTION METHOD FCEX02 HYDRAULIC FLUID - C-BLDG ELEVATOR SAMPLE ID: ............................................................................ DECEMBER I, EXTRACTION DATE nd TIME - YELLOW SAMPLE COLOR AND DESCRIPTION 1987 PCB-2258 MRC EXTRACT * ................ LOG NO: U-87 II-10-01 WEIGH OUT SAMPLE INTO A 14 OR 40 L PIERCE VIAL [X] FINAL WEICHT ....................... INITIAL WEIGHT .................. 0.944 j SAMPLE WEIGHT .................. SURROGATE . HS- 100 uL DEM 092386-01 SPIKE OF SAMPLE [j LS- 100 uL DEM 092386-01 ADD 10 oL BENZENE TO SAMPLE. [X] ULTRASONICATE SAMPLE FOR 1/2 HOUR IN A SOUND BATH. [] . . PLACE 1 aL OF THE EXTRACT INTO All/2 nL VIAL FOR ANALYSIS. NITROGEN BLOW DOWN IF REQUIRED . {] . . (] 10 FINAL VOLUME ................................nL PCB-2258 EXTRACT NO: ......................................... DECEMBER 13. 1987 DATE/TIME COMPLETED ........................................... MINOR ANALYST: ........................................................... 760.28-7642 ESC JOB NO: ................................................. MOMS 221080 FLOW SHEET PCFS02 FOE ESC EXTRACTION METHOD PCEX02 HYDRAULIC FLUID G-BLDC ELEVATOR SAMPLE ID: ............................................................................ (DUPLICATE) DECEMBER 1, EXTRACTION DATE and TIME: - YELLOW SAMPLE COLOR AND DESCRIPTION 1987 PCB-2259 MRC EXTRACT * ................ U-87 -11 -10-01 LOC NO: WEIGH OUT SAMPLE INTO A 14 OR A0 nL PIERCE VIAL [X] . FINAL WEIGHT ....................... INITIAL WEICHT .................. 0.914 g SAMPLE WEICHT ................... SPIKE OF SAMPLE [] ADD 10 aL BENZENE TO SAMPLE. (X] ULTRASONICATE SAMPLE FOR 1/2 HOUR IN A SOUND BATH. (] . . PUCE 1 aL OF THE EXTRACT INTO All/2 nL VIAL FOR ANALYSIS. NITROGEN BLOW DOWN IF REQUIRED . [] . . [| 10 FINAL VOLUME................................ nL PCB-2259 EXTRACT NO: ......................................... DECEMBER 13, DATE/TIME COMPLETED .............................. MINOR ANALYST. ...................................................... 760.28-7642 ESC JOB NO.................................................... 1987 HONS 221081 FLOW SHEET PCFS02 FOR ESC EXTRACTION METHOD FCEX02 SAMPLE ID: METHOD BLANK PCS - 2260 MRC EXTRACT * DECEMBER I, EXTRACTION DATE and TIME: *- CLEAR SAMPLE COLOR AND DESCRIPTION 1987 LOG NO ............ WEIGH OUT SAMPLE INTO A 14 OR 40 aL PIERCE VIAL [X] . . FINAL weight . INITIAL WEIGHT SAMPLE WEICKT SPIKE OF SAMPLE {] ADD 10 aL BENZENE TO SAMPLE. . [X] ULTRASONICATE SAMPLE FOR 1/2 HOUR IN A SOUND BATH. [] . . PUCE 1 aL OF THE EXTRACT INTO All/2 L VIAL FOR ANALYSIS. . [] . NITROGEN BLOW DOWN IF REQUIRED . {| 10 FINAL VOLUME................................L PCB-2260 EXTRACT NO: ......................................... DECEMBER 15, 1987 DATE/TIME COMPLETED ........................................... MINOR ANALYST: ........................................................... 760.28-7642 ESC JOB NO'. .................................................. HONS 221082 Tht following pagaa a how chaln-of-cuacody information for thla projacc NOUS 221083 MONSANTO MEMO FROM; DATE: Randy Person, Environsontal Sorvicos. V 101, 4-1282 cc: in . Ed*sa'o Novoabor 3, 1067 T. V. McMillan SUBJECT: TO: Hydraulic Fluid/C-Bldg Elorator (kt UJ bZusn 3F/ Mr. Muon Hugos U4S V- R3B S W1A V- a5> ^ go ^ Tho oncloiod saaplo ia Hydraulic Fluid froa C-building oloratorVo would liko to haro this analysod for PCB. If you nood aoro inforaation ud/or bars any quootiono about tho saaplo, don't honitato to call so at 4-1282. Thanks again. Kandy Parson ^/- I Z. <U^ Septum (pcdJt f(j '-Uu MOMS 221084 Tha following pagat datcriba Analytical Raquaat Information ganaratcd for this projact. MONS 221085 Tiw SCanp - <871217 1151> MONSANTO COMPANY/ENVIRONNENTAL SCIENCES CENTER ANALYSIS REQUEST DATE- NOVEMBER 10.1987 LOG NO: U-871110-01 REQUESTER RANDY PARSON PROJECT NO: 760.28-7642 LOGIN NOTEBOOK PAGE (To ba filled out at login.): 3759226 REPORT RESULTS TO: FILES/MEES,HUGHES.SHERMAN.MCKENZIE ANALYSIS REQUESTS SENT TO: FILES MEES,SHERMAN.HUCHES.MCKENZIE.MINOR SAMPLE PICKUP BY: SAMPLE LOCATION: U420 SAMPLE DESCRIPTION FOR 1 SAMPLES SAMPLE IDENTIFICATION NUMBER OF BOTTLES ESC NUKBER(S) HYDRAULIC FLUID/C-BLDC ELEVATOR C1W DRUM *1 1 X 40 aL PCB-2258 PCB-2259 NOTE: A SEPTUM WERE FOUND AT THE BOTTOM OF THE SAMPLE METHOD BLANK PCB-2260 RECORDED BY: MINOR REQUIRED ANALYSES: PCBa EXTRACTION LOGBOOK NOTEBOOK PAGE: 158642 ESC STANDARD EXTRACTION METHOD(S): PCEX02 ANALYTICAL TECHNIQUES: TECHNIQUE (IN) DATE COMPLETED ESC STANDARD ANALYSIS METHOD INSTRUMENT LOGBOOK PACE X- GC/IC ( ) 12/3/87 ECAN06 157307 FINAL REPORT NOTEBOOK PAGE: 3745304 OTHER NOTEBOOK PAGES: QUALITATIVE: X SEMIQUANTITATIVE: REQUIRED QA/QC: SEE COOD LABORATORY PRACTICES MANUAL COMPLETION DATE REQUESTED: QUANTITATIVE. X HONS 221086 COMMENTS: sample disposition: hold for 90 days SAFETY PRECAUTIONS: SEE SAFE LABORATORY PRACTICES MANUAL ANALYSIS REQUEST FILE NAME: AA76A2LI MOMS 221087 Tha following pagas ahow QA/QC data for aalaccad aaaplaa. HOMS 2210AS A M P L IT U D E /<000 Range Normalized 12.7C-. 11.M19.4IL 3 i AROCLOR 1242 M IC r.ocL. .. i 17.oc lt-M RT in minutes . SAMPLE: Meth: PCBSSM * * i i --t -1(1,1, 2i.ee es.ee 2s.ee 27.ee 29.ee si.ee PCB SUR. REC. INJECTED AT 9: 40: 51 ON DEC 3. 19B7 Rw: BR710 Proc: BP710 j S3.00 MONS 22X009 HYDRAULIC FLUID-G 3LDG <-- ,, i7-0*, RT in .mutts L. . t .i *> *?. sun ^ SAMPLE: A?d-4&)V Math: PCBSSN INJECTED AT 13:55:04 ON DEC 3, flaw: BA714 Proc: BP7U' t987 HONS 221090 amplitude/ ; ooo flange Noras2iTed 14.*e_ 12.6. to.sr HYDRAULIC FLUID-6 BLDG DUPLICATE . - PCD SUR. RfcC. SAMPLE: HLb'SJLS^ INJECTED AT 14:58:45 Of. OfcC 3 <987 Meth: PC9SSM Rsn: BR715 Proc: BP''15 ` ` HONS 221091 w ^ itude/ : ooo Range N o ra a liie d 19.42,. I ( 12.19, i METHOD 8LAJ.K ia.'*r 9.4_ I -IT- ..J i'.OO 19. M RT in Rinutes 22.90 i.i. i 24.60 27.00 PCB SUfl. RLC. III 1 29.M 32.00 SAMPLE: PdPiZ&C Meth: PCBSSM mnsINJECTED AT 16: 02: 24 on DEC 3. 1987 flaw: Proc: BP716 1 34.50 .1 97.00 MQNS 221092 O TVh9i S* * ^Am ss 11 & 11 11.94, lO.Tlj. \ T\ t.Ttl | LCW S1HUUTED SPIKE i ti 7-**n r(A s.aal 33.0 RT ift 34.97 SAMPLE; ttetft: PCSSSM 30.78 99.13 pea sua. ate. LS INJECTED AT 18: 09: 54 ON 3=C 3, 1987 flaw BA718 Pfoc: HONS 221093 tf^ L IT U E , 1000 rtonje f4>ralireo HONS 221094 AMPLITUDE/1000 Range N ornalized 43 it 35 54_ 27 96 _ 20 42_ 12.66. 22 00 24 37 in Minutes SAMPLE: Meth: PCBSSM 26.75 29.12 31.50 pcb SUfl. ^ 33.67 36 25 38 62 HS INJECTEO AT 21: 21: 20 ON DEC 3. 1907 Raw: BR721 Proc: BP721 41 00 HONS 221095 AMPLITUDE/1000 Range Normalized M 63 PCB-2258 + HS SPIKE 47.79. 36 76. 25 72. t 14.6! ita iaSiE.- 22.00 24.37 RT m minutes SAMPLE: Meth: PCBSSM 26.76 29.12 31.50 33.97 36.26 PCB 5U0 REC INJECTED AT 22: 25: 14 ON DEC 3. 1987 Raw: BR722 Proc: BP722 . 30 62 41 00 MOMS 221096 Tha following *actIon* dascriba important tarainology uaad In Quality Assuranca/Quality Control. Artalyta Extraction and Inatrunantnl Analysis CSC and ESC/UAO Qowd Laboratory Practleas Manuals can ba obtalnad by con tacting Janat Laa (tI4D) NETS 544-1273. QLP and QA/QC Suparrlaor. MOMS 221097 Quality Assurance/Quallty Control Terminology This soctlon describes commonly ujad terminology and phraaea which are used tn conjunction with Quality Assurance/Quallty Control (QA/QC) This infor mation may be helpful in understanding some details of QA/QC procedures which have been Incorporated in the present report. The following two sec tions also give useful Information concerning terminology used in analyte extraction end instrumental analysis of samples and sample extracts Quality Assuranee/Quallty Control Terminology used to describe activities which are dealgned to produce analytical results of known quality In an effort to minimize costs of environmental analyses, specific QA/QC elements have been Incorporated Into ESC/UAG extraction and analysis stops which should not unduely burden analytical studies with largo development and method validation coats. This approach has been taken so that sots of samples can be analyzed for various analytes without extensively validating methods ever wide concen tration ranges and without using methods which are designed for only one matrix. One price which one pays for this approach is that analytical pro* elalon and accuracy are sacrificed, somewhat. However, in many eases, when clearly defined regulatory limits have been set, confirming that the analyte is present at levels well below or well above the limit does not need the type of accuracy that Is required when the regulated analyte concentration is In the vicinity of tha regulatory limit. In these latter cases, more extensive QA/QC proceedures are required than are Included in the present study Precision Terminology used to evaluate the reproducibility of a certain determination. Parameters which affect analysis precision range from sample acquisition, to sample storage, to sample extraction, and finally to sample extract analyais. Normally, the major factor which affects the precision of the analysis is the sample extraction stop This step normally results in sample analysis precision on the order of or - 30%. The precision of a result can be determined In a number of ways Replicate analyses of the same sample, followed by the calculation of a percent relative standard deviation for that determination is the moat popular method of assessing precision. However, this cal culation should not be made when there are lees than three replicate points from which to calculate the percent relative standard devia tion. In addition, replicate extractions and instrumental analyses must be performed. Therefore obtaining percent relative standard deviation data can be very expensive and is not normally obtained un less large studies are being conducted. A second method of assess in8 precision is with the use of duplicate analyses The present report includee resulte of at least one sample which was analyzed in dupli cate. MOTE11 It is the responsibility of the analvils requestor to review these data and draw his own conclusions concarnlna the preci sion of che determination, and, more Importantly, .if Chs precision of the determination meets his needs. (continued) MOWS 221090 Pag* 2, Quality Aasurance/Qusllty Control Teminology Accuracy Taminology used to daeermine tho 'correctness* of the data Tha accuracy of moat ataps in tha analytia of samples ia typically on tha ordar of 10%. However, whan analyta eoncantrationa in th sampL# xtracta approach tha laval of datactlon of a determination, accuracy aa wall aa praclalon can approach 100% or greater. Tha accuracy of a dataralnatlon of an analyta which 1a praaant at concentrations which ora much greater than tha lnstruaantal laval of datactlon is nost strongly affactad by tha homogenlety of tha sample matrix and tha praclalon of tha extraction atap, which raaulta In typical aceuraclaa In envlronaental analyses to be on the ordar of 30%. Normally, tha accuracy of standard solutions which are used to cali brate analytical instrumentation is wall below this amount, and tharefore la normally not an Important factor In producing inaccurate data. From time to elate, analyta responses of standard solution* from different sources will be compared to standard solutions used for Instrument calibration. This Information la normally Included in tho section entitled 'QA/QC Results*- Tha accuracy of a result can be estimated in a number of ways The currant study uses surrogate standard recovery and native analyta recovory Information to aid In assosslng tho accuracy of a result This rocovery Information, normally raportsd aa percont recovory, gives you Information concornlng tha porcent of surrogato standards and native analytoa which ware recovered aftor adding to your sample matrix and performing tha various extractions, clean*ups, and instru mental analyses associated with tha datormlnatlon. Tha uso of sur rogates also assumes that tha spiked surrogates are bound In tho matrix In tha same way aa tha analytes of Interest. Surrogate stan dards are added to ovary sample while native analytes are added to only 10% of oach sat of samples. Tharefore surrogato standard recovery data could be used to correct tha reported results of an analyta concentration, If tha user of tha data fool such corrections era warranted. HOTC11 Ho data reported In this study Include inv correction for surrogate standard recovery. It Is the responsibility of the parson raouaatinx the analyses_to apply appropriate rsdovsrv corrections. If ha/aha foals that such corrections era warranted. Bias - Terminology uaod to describe how tha accuracy of a dataralnatlon may be affactad. A low bias means that values below the correct value are normally measured. A high bias means that values above tho correct value are normally measured. The instrumental analysis step of extract analysis normally does not contribute significantly to analysis bias. Host bias In environmental analysis Is intro duced In tha sample extraction atap. A low bias is introduced whan tha sample la not completely extracted and tha extract does not contain 100% of tha analyta. A high bias la Introduced whan the final volume of tha extract ia laaa than tha correct volume. Surrogate Standards (SS), which era discussed In tho next section, can be used to determine the amount of bias which is Incorporated In tho reported result. NOTfcll Ho data reported In this report Includes anv .correctIon for this bias.--I.t. ll .;h% rtlPQMlbilltY of the oarson_raauastins the anaivsss to apply appropriate bias corrections. _lf he/sha feels that such corrscclons era warranted. (continued) MOMS 221099 Page 3, Quality Asaurance/Quallty Control Terminology Laval of Dotactlon (LOD) - Terminology used to Indicate what analyte concentra tion will produce a signal-to-nolle ratio of 10. For the preaenc report, this value la not experimentally determined Normally, a Limit of Quantitation la uaed to determine the threshold concentra tion above which an analyte can be detected. Limit of Quantitation (LOQ) - Terminology uaed to Indicate the lowest analyce concentration which can reliably be quantified. The precision of /the determination of the analyte concentration at the LOQ la normallv on the order of 100%. The LOQ la normally determined experiments 11 by adding a known amount of analyte to the sample matrix and measuring the percent recovery at the LOQ. In some ceses, when char* Is Insufficient sample quantity, or for convenience, an LOQ will be determined using other methods. These methods should bo clea rly described in this report. Further Information The general area of Quality Asaurance/Quallty Control, along with much of the terminology deacribed above, Is very complex. The following references may provide further information which may be useful In understanding the validity of the results reported in this study. ASTM Standard Practice D4210-83 entitled *Intraleborstory Quality Control Procedures and a Dlacuaaion on Reporting Low-Level Data*. AfiTM Standard Practice D2777-77 entitled 'Determination of Preclalon and Blaa of Method! of Committee D-19 on Water*. An artlcla In Analytical Chemletrr. authored by 29 well-known environmental sclantiata. Thla article waa funded by a grant from the Environmental Protection Agency and acknowledges 24 additional sclantiata In Industry and goveriwaent who wars Involved In the review of the article. Its citation la "Principles of Environments! Anslysls*, L. H. Keith, at. al., Anal. Cham. 1983, 33, 2210 - 2218. AO cm Farg 138 entitled "Guidelines Establishing Teat Procedures for the Analysis of Pollutants Under the Clean Water Act; Final Rule and Interim Final Rule and Fropoaed Rule". This document includes details of EPA'a 600-aerlee analysis methods. A currant copy of these methods can be found in the October 28, 1984 Federal Register. QAQCTE:MH HONS 221100 Analyte Extraction Terminology This cclon describes commonly used terminology and phrases which are used in conjunction with snslyts extraction. This Information may ba helpful in understanding sons details of how analytes In your samples were isolated for instrumental analysis Instrumental Analysis Terminologies are given in the following section of this report. Sample Terminology used to reference the material which you submit for analysis. Saaples may be solid, liquid, and in some eases, gases In general, when a sample Is recelvad for analysis. It Is logged Into the E5C sample login book and proper chain-of'Custody documents are maintained In the event this Information may be required for litigation purposes, Analyte - Terminology used to reference specific compounds or formulations of compounds. When an analysis Is requested for a certain analyte within a certain sample matrix, normally some type of extraction process Is required, Extrsctlon - This terminology refers to the step which Isolates the analyts of Interest Into an appropriate solvent. Extraction la required for several reasons, In many cases, the concentration of the analyte la below the level of detection of the Instrument which will be used for analysis. Therefore, extraction involves re moving the enalyte of Interest from a relatively large volume of sample and placing It Into a relatively small volume of sol vent. This places the analyte In the solvent at a concentration which can easily be detected by the analytical Instrument. A second reason that extraction Is required. Is that the sample may not be appropriate for direct Instrumental analysis of the analyte of Interest. This can be easily understood for analytes In soils. Very few analytical Instruments allow soils to be directly Inserted Into the Instrument, Therefore some type of Isolation step (1, e, extraction) Is required In order to place the analyte In an appropriate metrlx for instrumental analysis. When the analyte of Interest is present at sufficient concentra tion, end the sample matrix can be directly inserted Into che analytical Instrument, the sample, or the diluted sample, can be directly analyzed. However, this case represents a minority of sample analyses which ESC is asked to perform, (continued) MOMS 22U01 Psge 2, Analyta Extraction Ttrminology Matrix - Taralnology used to reference tha major components of a saapl# oat eaaas. aajor components ara not of direct Intarast axeept *s thay affact tha cypas of axtraetlon stop* and othar Isolation procaduras which mist ba uaad to lsolata tha analyta fron tha sample aatrlx. For tha majority of anvlronaantal saaplas which ESC Is asked to analyze, the aatrlx Is nonully water or soli. However, many anvlronaantal matrices contain relatively high lavals of organic compounds which asy lncarfar with tha lnatruaental analysis of the analyte of Intarast Therefore, depending upon tha analyta of Interest, tha required level of detection, and tha amounts and tvpts of othar organic materials which aay lntarfar with the Instrumental analysis, extraction aethods aust be developed which are very specific for a given set of samples. In order to deal with almost a lieltleaa sec of matrices, analytes, extraction aethods and instruaental aethods, an organized approach to saaple extraction, followed by Instrumental analysis, has been developed at ESC Extract - Terminology used to Identify the analyte-contalnlng solvent which was obtained froa the extraction of e certain aatrlx. Extract Clean-up - Terminology used to Identify chealcal steps which are required In order to reduce the concentration of organic compounds which aay be extracted with the analyte of Interest. These eoextracted compounds aay be at such high levels and/or produce responses so that thay lntarfer with the lnatruaental analysis of the analyte In the extract. Extractable Compounds - Terminology which refers to the ability of a compound to be Isolated from the sample matrix end pieced Into the extract solvent. When the sample matrix Is primarily soil which contains little organic matter, moat organic compounds are extractable com pounds. However, when the sample matrix Is primsrlly water, onLy thoee compound# which are hydrophobic are extractable compounds Standard Extraction Method Terminology used to reference an organlzad description of the steps Involved In Isolating an analyte from a given matrix. Theta methods are assigned short names which can also be used ee computer file names for these methode. The names of specciflc Standard Extraction Ksthods which are used in this study are listed la the final report In the section entitled 'Details* In addition, copies of these Standard Extraction Methods ara shown in e separate section of this report. Standard Extraction Methods also include details of sample clean-up, If required. Exerection flow Sheet * Terminology uaed to reference a graphic description of a Standard Extraction Method. This flow aheee is filled out by the analyet In the laboratory and eervas ae e detailed record of what occurred In the sample extraction seep. Flow sheets of In dividual sample exeracelona may be Included in e section of this report. (contlnuad) MOHS 221102 Pag* 3, Analyte Extraction Taminololgy Surrogate Standard* (SS) - On* Important eltient In the extraction of an analyte from a matrix, is the determination of what percent of the analyte vac actually extracted from the matrix. For methods which involve liquid/liquid extraction of water with an organic solvent, ot liquid/solid extraction of aoila with an organic eolvont, it is Imperative that data be obtained which glvea the analyst* requestor lnforaatlon concerning what percentage of the analyte wae Isolated in the extract during the extraction step. Surrogate Standard* sarva thla important purpose. The philosophy on the use of Surrogate Standards is as diverse as the analysts who use thsa. If cost wore no object, analyte recovery lnforaatlon could be obtained by the us* of standards addition analysia aethoda. However, since aany samples require extensive labor to isolate an analyte into an extract, standards addition analysis aethoda are too costly for aost studies. (A standards addition ana lysis requires each sample to b* extracted and analyzed at least three tlaes.) Surrogate Standards give the sane type of information, with only on* analysis being required. A "Surrogate" Standard is a coapound which is chosen to behave exactly as the analyte. It is a surrogate for that analyte and thus lnforaatlon obtained for thla surrogate can be assumed to also apply to the analyte of Interest. For ths analysis of regulated analytes, it is important that when data la generated that shows that the analyte is not present, that we can also show that if ths regulated analyte were present in the sample matrix, it would have been detected. This Is especially true when complex extraction and instrumental analysis steps are involved in this determination Therefore, when an extraction is performed, a known amount of s Surrogate Standard is added to the cample before any extrection steps take place. When the extract is then analyzed for the analyts of interest, the amount of the Surrogate Standard is also determined From this information on* can document, for each sample, what recoveries were measured for this Surrogate Compound. From this, on* can describe some level of confidence on the data generated for the analyte of Interest. A detailed discussion on how Surrogate Standards are chosen is be yond Che scope of this section on Analyte Extraction Terminology. ISC normally uses two types of Surrogate Standards. The first is when the surrogate la exactly the same as the analyts of interest, except that the naturally occurring carbon, hydrogen, or halogen atoms In the analyte have been replaced with non-naturally occurring Isotopes. Those surrogetee can be expected to act exactly as ths native analytes. One good example of this type of surrogate is the 2,3,7,S-TCDD surrogate In vhleh all carbon atoms are carbon-13 or all chlorine atoms are chlorine-37. (continued) HONS 221103 Page 4, Analyte Extraction Terminology The second type of Surrogate Standard la one which does not have the same chemical structure as the analyte of Interest, but Is known or assumed to act chemicelly Identicel to the analyte of Interest during the extraction and clean-up steps. Examples of this type of surrogates are deuterated compounds which say be added to a matrix In which any chromatographable materials are to be Identified This approach can only be applied to GC/MS analyses, since the surrogates can be differentiated from the native compounds from their different mass spectra. Since It la not known bafora sample extrac tion and axtract anelyala whet analytee nay be present, surrogates must be chosen that could not possibly be praeant in the semple In addition, since only liquid/liquid or liquid/solid extraction would ba Involved, with no clean-up (since clean-up would remove compounds in which cha requester la intaraatad) any hydrophobic dsutoratad compound could servo as e surrogate. Normally, phanol-dS, 2-CL-phenol-d4, CL2-benzene-d4, pyrene*dlO and chryaene-dl2 are used at Surrogate Standards for tho analysis of a wide variety of hydro phobic materials In environmental samples. A sub-set of this second type of Surrogate Standards srs the surrogstes which ere used In cha capillary CC/EC analysis of Aroclor formulations. Since mast tpectrometrlc detection le not used, surrogates which contain unlqus laocopas cannot ba dis tinguished from choir native counterparts Therefore, other com pounds ara used as Surrogate Standards since they have bean ob served to see exactly aa cha polychlorinated biphenyls (FCJa) in the Aroclor formulations. Any helogenated compound can ba used which acta exactly as PCBs In the extraction and clean-up step. ESC normally uses CLS-benxene and 2,4,6-CU-biphenyl for chla pur pose. Native Analytes Terminology which rofaroncoa tho analytes of intoreec which contain naturally-occurring laotopas of carbon, hydrogen, helogans, ate. Native Spike Terminology which roforencos the edditlon of a known amount of native analytes to the sample eatrix. Normally, at least one sample will ba spiked with the native analyte at the reported level of de tection (low native spike) and ae 10 tinea the level of detection (high native spike). Recoveries of the native analytes provide fur ther documentation on tho quality of tho analyses performed. For sample aata which contain more than 10 samples, cha frequency of low and high native spikes is 10% of the number of samples. (contlnuad) HONS 221104 Pag* 5, An*lye* Extraction Terminology M*thod Blank * Terminology which refers to a sanpl* which It known to contain non* of th* analyc** of lnearaac. For wae*r analyses, this It nor mally Burdick and Jackton Brand Water, da-Ionized, or dlstllltd wat*r. For toll, It may b* toll which haa b**n previously analyzed and known eo contain non* of th* analyeas of Interest. All extraccion te*p*. using randomly **l*ct*d glastwar*, solvents, and all turrogae* spiking solutions must b* us*d. This provides documen tation that th* analyc** of interest wera not lnadverttntly present In extraction gltstware and solvents ut*d in th* analysis. A minimum of on* method blank must b* generated with each tat of tamplss For sanpl* sets containing mors chan 10 samples, method blanks /re gener ated at a frequency of 10* of th* number of sanpl** Duplicate Analyses - Terminology used to indicate Che duplicate extraction and duplicate extract analysis of a sample. This provides documention on th* precision of an analysis. Normally the precision of environ mental analyses of homogeneous samples Is on the order of 30*. A minimum of on* duplicate analysis Is required for each sample sac For sample sets containing more than 10 samples, duplicate enalysas are generated at a frequency of 10% of the number of samples. Further Information The general area of Analyte Extraction, along with much of the terminology described above. Is very complex. The following references may provide further Information which may be useful In understanding extraction funda mentals and terminology. 40 CFR Fart 134 entitled 'Guidelines Establishing Test Procedures for the Analysis of Pollutants Undar the Clean Water Act; Final Rule and Interim Final Rule and Proposed Rule". This document Includes details of EPA's 600-serles analysis methods, A current copy of these methods esn be found In th* October 26, 1984 Federal Register. Statement of Work for the Contract Laboratory Prooram which Is used In conjunction with CPA's Superfund Sit* studies. A current copy say be obtained by contacting: Joan F. Flak, Project Officer Analytical Support Branch Hmsardous Response Support Division USCPA Washington, D. C. 20480 AHEXTEiKH HONS 221105 Instrumental Analysis Terminology Thla taction daacrlbat commonly uaad terminology and phraaas which art used in conjunction with extract analysis. This information may bs helpful in understanding some details of how Instrumental analyses of sample extracts were performed. The previous section of this report describes terminology associated with analyte extraction. Sample Extract - Terminology used to describe the solvent containing the analyte of Interest which Is obtained from some type of sample extraction step. Detailed Information on how this extract is pre pared can be found in the Standard Extraction Methods and flow sheets essoclatad with the methods. Suanwrles of these methods which were used for this project can be found in a separate section of this report. Inearnal Standard (IS) - Terminology used to reference a compound which Is added to the sample extract and standard solutions of the analytes of Interest lHMdlately before instrumentel analysis. The purpose of the Internal standard Is to provide data which can be used to eorreet for variations In lnjeeted volumes of extract and standard solutions which may occur during Instrumental analysis. The Internal standard must not be present In the sample extract. Typical internal standards used In mass spectrometrlc analyses are benzene-d6, naph thalene -d*t anthracene-dlO and chrysene*dl2. These deuteratad compounds produce unique mass spectra and are not present In naturally*occurring samples, A commonly used Internal standard for CC/EC analysis Is hexaehlorobenseno. Internal Standard Quantitation Method - Terminology which refers to a method of data analysis. This method requires that e known amount of an Internal standard be added to the sample extract prior to instru mental analysis. Responses of all analytes are calculated relstivs to the Internal standard using tha following relationship: (Analyte Area) RR Relative Response - .......................................................... (Internal Standard Area) If different volumes of the sample extracts end stendard solutions era Injected, these differences are raflactad by differences in the internal standard area. In addition, If Instrument sensitivity changas, these changes era also raflactad In changes in the inter nal standard area. Tha calculation of tha relative response cor rects for these types of fluxuatlons. In order to determine the analyte concentretlon-Relatlve Response reletlonshlp, analyte Relative Response Factors are calculated using ths following relationship for data obtained from the analysis of standard solutions: (continued) MOHS 221106 Pegs 2, Instrumental Analysis Terminology (Incsrnal Standard (Analyta Arsa) Concantratlon) RAF - Rslatlv* Response Factor - ............................................................................. (Internal Standard (Analyta Area) Concantratlon) Whan identical amounts of tha internal seanderd are added to both extracts and standard solutions, the Internal standard concentration tsra in tha above equation can ba a1initiated. Vhen this is dona and Relative Response is substituted for the ratio of analyte area to internal standard area, the RAF equation becomes: RAF ~ RR/(Analyte Coneantraelon) Analyta concentrations in tha extracts are calculated from the fol lowing equation: Analyte Extract Concantratlon - RA/RRF In order to obtain the concentration of the analyte in the sampla, tha following equation la used; (Analyte Extract Concentration ) (Extract Volume) Analyte Sample Concentration - ....................................................................... (Amount of Sample Extracted) The area terms In the above equations may be total Ion areas, F10 peak areas, SC peak areas, or extracted Ion areas. The details of how the Internal standard quantitation method is applied to specific methods are described In Che various Instrumental Standard Analysis Methods, The following equation shews what calculations should be made to correct for analytical bias: (Analyta Sample Concentration) Analyte Sampla Concentration - ............................................................ (Corrected for Analytical Bias) (Assumed Analyte Recovery) The Assumed Analyte Recovery can be obtained from an average of surrogate recoveries or native analyte recoveries, measured for the sample In question. ROTE!1 No data reported in this study Include any correction for surrogate standard recovery. It is the responsi bility of tha person requesting tha analyses to apply appropriate recovery corrections, If he/she feels ehat such corrections are warranted. External Standard Quantitation Method - Terminology which refers to a method of data analysis. This method requires that a known amount of tha analyte standard be analysed under the sane conditions as the sample extract. In order to determine the analyte concentrationanalyte response relationship. Response Factors are obtained from the following relationship: (continued) MOHS 22U07 Pag* 3, Instrumental Analysis Terminology RF - Response Factor - (Anaiyts Arsa)/(Analye* Concentration) Analyts concentrations In the extracts are calculated fron the fol loving equation. Analyte Extract Concentration - (Analyte Area)/RF In order to obtain the concentration of the enelyt* In the sample, the following equation is used: (Analyte Extract Concentration) (Extract Volume) Analyte Sample Concentration - --.........-- .......................................... (Amount of Sample Extracted) The area terns In the above equations may be total Ion areas. FID peak areas, EC peak areas, or extracted Ion areas. The datalls of how the external standard quantitation method Is applied to apecific methods ere described In the various instrumental Standard Analysis Methods. The following equation shows what calculations should be mad* to correct for enelytical bias: (Analyte Semple Concentration) Analyte Sample Concentration ................................................................ (Corrected for Analytical Bias) (Assumed Analyte Recove ry) The Aseumed Analyte Recovery can be obtained froa an average of surrogate recoveries or native analyte recoveries, measured for the eample in question. MOTE11 tlo data reported In this study Include any correction for surrogate standard recovery. It Is the rsspons! blllty of the person requesting the enelyees to apply appropriate recovery corrections. If be/eh* feels that such corrections are warranted, Stenderd Analysis Kathode - Terminology used to reference an organised description of tha steps involved in the Instrumental analysis of s sample or s sample extract. These methods ere assigned short names which can also be used as computer file names for these methods, The names of specific Instrumental Standard Analysis Methods which are used in this study ere listed in the final report in the section entitled 'Details". In addition, copies of these Standard Analysis Methods are shown In a separate section of this report. Flow sheets of the Standard Analysis Methods are usually also provided in this section. Analysis Flow Sheet Terminology used to reference a graphic description of a Standard Analysis Method. This flow sheet gives specific information on how extracts and standard* are analyzed end vhae types of data reduction methods ere used. (continued) HONS 221108 Instrumental Analysis Terminology Further Information The general area of Extract Analysis, along with much of the terminology described above, is very complex. References provided In the previous section entitled "Analyte Extraction Terminology" may provide further Information which may be useful In understanding instrumental analysis fundamentals and terminology. INANTE:MH HONS 221109