Document OzqqDnVyLMxDqEwbNX5m8gmVe
INDUSTRIAL HYGIENE RESULTS
June 2, 1983.
Measure
exposure to employees of the
Process & Unit Control Laboratory.
3-10-83, 3-15-83, 3-16-83
RECOMMENDATIONS:
During the two minutes required to prepare a pressure filter for use in filtering a sample, one Lab employee was exposed to 1.82 asbestos fibers per cubic centimeter of air. This exposure is less than the Ceiling limit of 10 fibers/cc established for asbestos.
On 3-15-83 and 3-16-83 lab employees were exposed to 0. 03.and 0.07 asbestos fibers per cubic centimeter of air. Monitoring periods were 396 and 415 minutes, respectively. These exposures are less than the 8 hour time weighted average permissible exposure limit of 2 fibers/cc for asbestos.
1. Request additional monitoring of filter preparation.
2. Share this information with lab employees.
ASBESTOS FIBERS/CC
DATE
SAMPLE TIME,
MINUTES
OPERATION
RESPIRATOR SAMPLE
WORN
TYPE/METHOD
OPERATOR
1.82
0.03 0.07
3-10-83
2
3-15-83 3-16-83
396 415
Preparing pressure filter for use
Normal lab operations
Normal lab operations
No
No No
P FC
P FC P FC
DHB,Jr.
RRB RGC
FC " filter cassette DISCUSSION:
METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS COPY TO:
P personal
Personnel in the Process/Unit Control Laboratory use filter
pads coated with asbestos fiber to filter some of the
process samples they receive. They requested that asbestos
exposure monitoring be performed. We sampled for peak
exposure during the time a filter was being prepared for use, ar
for >6 hours as an estimate of full shift exposure, because an
individual might perform several filtrations during an 8 hour
shift.
Microscopy
H. G. Kuntz/K. E. Williams
IHI - Kemron
.
D. H. Binegar, Jr., R. R. Bonnerp^M. W. Bosserman, R. E. Crum,
R. G. Cunningham, T. W. Heiskell, J. E. McDermott, J. B.
Mickey, Medical - 3.
UCC 016209
K. E. Williams