Document OzqbdRN6rbrrxyGMoYndzRM5v
f
IJ
Product Tcci
Monsajsto Chemical Gompany
Anniston, Alabama Plant Laboratory
STANDARD ANALYTICAL METHOD
AROCLORS AMD PYRAMOLS WATER
Mothod No.
047
DATE ISSUED
5/9/61
WRITTEN EY
W.W.K.
PAOE
1 OF
APPROVED BY
W.W.K.
TKl Mothod
53 Suporiodoo
Rovloo.
Instruction* Issued On ______ 6/5/57
T hi t K
SCOPE
This method determines the water content In Aroclors and Pyranols using the "onesolution" Karl Fischer reagent titrating to a "Dead Stop" end point.
EQUIPMENT
.
See General Method G-7
REAGENTS
.
See General Method G-7
SAFETY
Aroclors and Pyranols are Irritating to the skin. The vapors of hot materials are irritating to the eyes and upper respiratory system. If accidental contact Is made with the eyes, flush Immediately with large quantities of water for at least 15 minutes and get immediate medical attention. The higher Aroclors must be hot to pour, so be careful of thermal burns.
DETERMINATION
1. Remove a clean dry 150-ml beaker from a drying oven.
2. Fill the beaker ca. 2/3 full of well mixed sample.
3. Cover tightly with a piece of aluminum foil and weigh to the nearest 0.1 g. on a beam balance.
4. Use ca. 3OO ml of a 50-50 mixture of dry benzene In dry methanol for solvent
in KF titration flask.
5. Blank out the solvent. See General Method G-7. 6. Add sufficient sample to close the eye.
DSW 331756
STLCOPCB4078331
Standard Analytical Method 047 May 9, 1961
Page 2 of 2 pagaa
PITERMINATION - continued
7. Titrate the water according to General Method 0*7, Part A. 8. Rawaigh tha beaker to obtain temple weight.
Mil
ppm Ha0 . aLJ[OJgJB.yto s 106 * temple wt.
Report reeulta to the nearett 1 ppm.
0S*M,757
STLCOPCB4078332