Document Ozoq3XB8n5pJe3r2nYeYRK4Bv
CC-MS Characterization of PCBs (Aroclora) of Labeling of Arocloii;48 and 1254
by D L, Scalling
and <! N. Huclcina
Fiah-Paacicida Issaarch Laboratory Bureau of Spore Fisheries and Wildlife
Columbia, Missouri 65201
MUMS 088116
GC-MS Characterization of PCBu (Aroclora) and 36C1 Labeling of Arodor1248 and 1254
D. L. Stalling and J. N, Kuchina
The isomer composition of the Aroclor 1200 series was characterized by CC-MS using temperature programming and SE-30 SCOT capillary columns. A method is described for the preparation and purification of 3Cl-labeled Aroclor 1248 and 1254. Neutron irradiation of tha commercial material vi s used to prepare the 3C1labeled material. Purification of the irradiated product was accomplished by silicic acid column chratatography. Yields of the purified produce were between 63 and 99 Iercent, with no detectable alteration of the isomer composition. Ten percent of tha 3C1 pro duced was associated with the unchanged PCB Isomers. The remaining radioactivity was contained in polychlorinated eerphenyls. The terphenyls vere produced by irradiation polymerization,'and they were easily separated from tha PCBs. Mass spectrometry, utilizing either temperature-programmed gas chromatography or direct probe sample introduction, was used to characterize the irradiation products. The radioactive materials are being utilized in experiments to determine uptake and metabolism of PCBs by aquatic organisms.
MONS 088112
CC-MS Characterization of P3s (Arociors) and 36C1 Labeling of Aroclor^ 1248 and 1254
David L. Stalling and James N. Huekias Fish-Peacicide Research Laboratory Route 1, Columbia, Missouri 65201
i t
\
Polychlorinated biphenyls <PCBs) have been found In fish and
wildlife from Sweden (1), Britain end the Netherlands (2,3) and the
United States (4) at levels which may Interfere with pesticide residue
analyses, PCBs have gas chromatographic characteristics similar to
many organochlorine pesticides and Jensen (5) first identified unknown
gas chromate graphic peaks as PCBs in extracts of pike and an eagle
analysed for organochlorine insecticides, Thd environmental occurrence,
uses, and present toxicological aspects of PCBs were recently reviewed
(6), The Monsanto Company has restricted the sale of PCBs for usss
in which disposal of the end products cannot be controlled, such as
use of PCBs ns plasticisers (7), The Monnanto Company is Che sole manufacturer of PCBs in Che
m
United States (7) and markets eight formulations of chlorinated biphenyla under the trademarks Aroclor 1221, 1212, 12A2, 1248, 1254, 1260, 1262,
and 1268. The latter two digits designate the percent chlorine of each formulation. Aroclor 1254 ia the material produced in greatest quan tities and is used in closed-system heat exchangers and as a dielectric fluid in capacitors (9). Arocloi 1242 is used as a hydraulic fluid and Arocloi 1260 aa a plasticizer. Chlorinated terphenyls are marketed under the trademark Arocloi 5442 and 5460, A mixture of bi- and car-* phenyls is designated Arocloi 4465.
MQNS 088118
Several analytical procedures have been proposed foe chroraato-- graphic separation of PCBs and pesticides. Separation of PCBs from pesticides by thin layer chromatography (8) with Al^Oj does not separate alIrin, heptachlor or DDE from the PCBs. Reynolds (10) reported thnt chromatography on a Florlsl1 column removed PCBs from five of eight pesticides evaluated. Aldrln, heptachlor, and DDE eluted In the PCD fraction. Column chromatography with silicic add (11) separated tha various Aroclor formulations from all of the common chlorinated pesticides except aldrln. This procedure la quite satisfactory for use In routine separations of PCBs and pesticides, however, deactivation of the silicic acid with water muse be dont precisely.
Limited Information exists on the biological consequences of
PCS exposures or residues In fish. A synergistic toxicological interaction In flies was reported between PCBs and tha Insecticides
dieldrin and DDT (8). Our principal concern in preparing radioactive ^Cl-labeled PCBs is eo delineate their dynamics in fish and other
components of aquatic ecosystems. We describe the characterization of Aroclor formulations by
programmed temperature GLC-MS SCOT capillary column and the prep(S
aratlon and purification of neutron Irradiated Aroclor 1248 and 36
1254. An analytical procedure was evaluated by uae of purified Cl-
labeled Aroclor formulations.
-
2
oabU9 *Qt*S
EXPERIMENTAL
Sample Preparation Quartz vials (3" x 3/S" i.d.) containing 0.3 or 1.0 g of
Arocloi 1254 and 1.0 g of Arocloi1248 ware cooled with dry ice
and scaled under vacuum with a torch. The vlale were wrapped with aluminum foil and saal-walded in a 4" x 1 1/8" aluminum can and leak tested. Neutron-irradiation
Preliminary Irradiations of 0.S g of Axoclor 1254 were made for 60 hra and for 36 min at a neutron flax density of 4-5 x 10^
3 12 3 n/ca and for 6 hra at a flux density of 5-7 x 10 n/cm . Irradia tion of 1.0 g of Axoclor 1248 and 1234 wis made for 40 <n at a flux density of 4-5 x 10^ n/cm^. The irradiations were conducted
at the Research Reactor Facility of the University of Missouri,
Columbia, Missouri. After irradiation, activity in the vials was
allowed to dncay for a minimum of 3 days prior to opening the vial.
Sample Solution
-
The vials were crushed with s metal rod in a 100-ml, heavy-wallad
bottle, capped with a Teflon-lined cap having a 1/4" hole. This and
all subsequent manipulations of the material were conducted In a hood
designed for radiochemical operations. The irradiated materials ware
disaolved In redistilled hexane. This solution vas filtered through
glass-wool into s 25-ml, volumetric flask. Twenty-five aicrolitara
of the solution vas dilutad 100-fold and a 100-^1 aliquot used for
determination of the radioactivity produced.
3 MONS 088120
Radioactive Assay A Beckman 2QG-L liquid aci:
Isosec discriminator, sec for vss used to determine all radic glaaa scint-wllation vials conedry mix dissolved la toluene. PBD z-(4'-t-butylphenyl) 5-(4'0.5 g/1 PBBD ^-(4'-biphenyl)-6efficiency for ^C1 was decermr.
Silicic acid cleanup The irradiated Aroclo^ :
than 5 ml slid pipetted onto a 1.4 containing 25 g of silicic acid545 column chromatography is d;. however, we modified the column our samples. The silicic acid, to 3 percent of aillcic acid at a large mouth, 1-gal glass Jar ; lined cap and tumbled for 4*5 h. (cs. 500 g) vas then covered wi.. slurried prior to preparation * slurriad silicic acld-celice
with a Teflon(*S*) stopcock) to a
The sample was applied and pc;.sure vaa percolated through t;
;er with a variable cle energy spectrum. >lee were placed in uf Beckman Fluoralloy lined 8.0 g/l butyl ,4-oxidozoleJ and .zolej. Counting orcant#
2 concentrated to lees 3 ca long glass column 2. Silicic aeid-Calita jur and Burke (11), '.chod for dsanup of nd water (equivalent >.ed or oeasursd into . . u xane-rinsed 9 slualnusv* :ad column material
petroleum ether and ,raphlc column. The
glass column (equipped t to 25 g of adsorbent* 0 ml) under slight pres.ow rate of 4-5 ml/ain.
088141
mqns
Iha first 200 al of petroleum ether was collected and designated
as fraction I-A. The last 50 ml of the petroleum ether eluate vaa
discarded i'.ue to the possibility of contamination by terphanyl
materials. Tha column was Chen eluted with 200 ml of acetonitrile-
hexane-met)ylane chloride 1)19:80 (viv:v); this eluate was designated as fraction 11 and was examined by GC-MS and MS using Che direct
probe. After this initial cleanup, the PCBs in fraction I-A of tha
irradiated 1.0-g samples of Aroclor^11248 and 1254 were evaporated
..
I' '
separately to less than 5 ml and pipetted onco, and eluted from
individual silicic acid-celite columns vlth 200 ml of petroleum
ether. These eluates were designated fraction I.
Sample Characterization
A gas chromatograph-mass spectrometer (GC-MS) was used to determine
~ the composition of tha eluted materials from each Arodor formulation.
The PCBs in fraction 1 from each irradiated Aroclor were chromatographed
using a 50' x 0.020" i.d. SE-30 support-coated, open-tubular (SCOT) cap
illary column. Gas chromatograms ware also obtained from standard solutions
of Aroclor 1248 and 1254. The materials in fraction II from each irrad
iated Arodor were examined by mass spectrometry, introducing the sample
with che direct probe. The mass spectra were also determined for Arodor
1248, 1254, 5442 and 5460 with tha direct probe.
The irradiated materials prior to cleanup were spotted on Eastman
Chromatogram Sheet, 2" x 8" strips (Type K-301-R, Distillation Production
Industries, Rochester, N.Y.), and developed in hexane, A Packard Model
7201 radio-chromatogram scanner (Packard Instrument Co., Inc.) was used
5 MONS Q881d2
for detection, measurement, end recording of Che radioactivity la
Che components separated by TLC.
Mass Spectrometry
Mesa apectromctrlc analyses were performed with a double
focusing, low rasoluclon mesa apeccrometi r (Model 270, Perlcin-Elmer
Corp., Norwalk, Coon.) coupled through a Uatson-Bieman molecular
separator to a temperature-programmed gaa chromatograph. The CC
column was a SO' x 0,020" SE-30 SCOT chrcaatographic column. Helium
at 9 pslg waa used aa the carrier gaa. The temperature program race
was 2* C/mii.. In moat cases, the Initial temperature was ISO* C with
a 2 min delay prior to temperature programming. The molecular sep-
,
arator was talntained at 260* C and the CC-lnlec was held at 220* C. The ion source and target were maintained at ISO* C and 130* C, respectively. All mass spectra were recorded at 70 eV electron energy
i ( i
with 2,000 volts accelerating potential. The filament emission current:
vas 100 jia. Samples Introduced by the dlcect-probe were introduced sc
a probe temperature of ca. 70* C, and, after Introduction, were haaeed
to 2S0* C at approximately 10* C/min. Spectra scan races were 3 sec/
decade from 20 to 800 omu. Perfluordecalin was used aa a mass calibration
standard (12).
RESULTS AND DISCUSSION
CC-MS Characterization of the Aroclor series The composition of the various Aroclor formulations is best
illustrated by Figures 1 and 2. The number above the gas chromatographic
6 MQNS 088123
peak* represencs cha number o chlorine acorns substituted oa cha biphenyl molecule. Chromatographic peaks designated as containing a PC8 isomer with a given number of chlorine atoms are the same aa undasignated peaks immediately above or below a numbered peak. These values were determined from the mass spectrum of each chroma tographic peak. The molecular weights of the possible compounds composing the Aroclor formulations are listed in Table 1.
Each Aroclor formulation contained a group of predominant, characteristic isomers. The composition of the moat predominant isomers (">gure 1 and 2), and Che percer t chlorine in each isomer (Table 1) is related to the percent chlorine in each Aroclor form
al)
ulatioo. Fsr example, Aroclor 1221 contains 20-percent chlorine and its predominant isomer, chlorobiphenyl, is 18.6-percent chlorine; some dlchlorobiphenyl isomers (31.5 percent chlorine) ara also present. Aroclor 12-18 contains trl-, tetra- and pentachlorobiphenyl Isomers vhich contain 41.02-, 48.28-, and 54.01-percent chlorine, respectively.
<$> Aroclor 1254 contains only trace levels of trichloro isomers. Similarly, Aroclor 1268 has principally octa- and nonachlorobiphenyl isomers which are 65.73- and 68.47-percenc chlorine, respectively.
The mass spectra of tha chlorinated biphenyl and tarphenyls ara characterised by a strong parent ion peak with an isotope distribution determined by the number of chlorine atoms substituted oa tha aromatic rings. Tha spectra are quite simple and ara readily identified. Bagley ct al. (13) hava reported tha mass spectra of the components in Aroclor 1254.
7 MQAS oaaid<
Ths nats pccra rprenclag Aroclor0' 5442 and 5460 ladlcats chat Aroclor-^ 5442 and 5460 are composed of chlorinated terpheayla substituted with no more than 6 or 11 chlorine atoms, respectively* However* trices of isomers containing 7 <>r 12 chlorine atoms were detected. These Isomers contain 48.39 (t< chlorine atoms) and 63,74 ' (11 chloric* atoms) percent chlorine* respectively (Table 1). Further isomer characterization of the chlorinated terphenyl Aroclor formulations must await :he development of more suitable GC-MS chromatographic conditions. 36Cl-labele l Aroclor 1248 and 1254
Chlori.ie-36 i produced by (n,r) 'eaction with ^Cl. The
croee section for neutron capture by 33CJ ia 45 barns. The half-life of 3C1 is 'i.OQO yrs and this isotope emits a 0.7 mevparticle. Chlorine-38 is also produced from 37C1 by e (n,Y) raaction, but its half-life if only 37 minutes and the crosa section for the (n,r) reaction ia 0.56 ban.a.
Thin ltyer chromatography, and temperature-programmed gas chromatography combined with mass spectrometry are suitable for determining tha compositional changes which occur in Arcelor materials as a result of neutron irradiation. The Arocloi^ 1254 irradiated for
60 hr* vaa not usable because the material decomposed and was inaolubla In bexaae. Tha radiochromatograms of Aroclor 1248 and 1254 irradiatad
for 40 min revealed the presence of two zones of radioseciva matsrial with Rf values of 0.90 and 0.47 (Figure 3). Ho difference in Rj values of tha radioactive PCBs were observed for Aroclor 1248 and 1254 and
the Rf values ware 0.90. Radioactivity of tha slaver migrating material
8
MONS Odd Id 5
vsa approximately 10 times that of the radioactive PCBs. Silicic
add column chromatography wich petroleum ether (fraccioa X) eluted
only the radioactive PCS materials (Rj 0,90).
The mixture of hexane-acetonitrlle-methylena chloride eluted
the slower migrating material (Rf 0.47) in fraction 11. The radio
activity associated wich the column eluat ss from various irradiations
is presented in Table 2. Comparison of GC-MS chromatograms of Arodor
1248 and 1254 with fraction I of the irradiated materials revealed no
significant alteration of the concentration ratios of individual isomers
of either Pi-8 material (Figures 4 and 5).
The specific activity of the PCBs recovered in fraction X of
tha 6-hr irradiated Arodor*' 1254 was greater than that of PCBs
.
exposed for 36 min at higher neutron flux and eluted in fraction Z.
The compoait.itlon of the PCBs exposed to the higher neutron flux was
similar to tha starting material except that the relative concentrations
of two major isomers (each containing 5 chlorine atoms) were increased
by 10-15 percent. Tha specific activity of the irradiated Arodor
1248 and 1254 recovered in fraction 1 (Table 2) was expected to be
slightly higher for Arodor1' 1254 than for Arodor-'1248 because mors
chlorine was Irradiated per gram of Arodor 1254.
The mass spectra of the material eluted in fraction 11 from the irradiated Arodo^ 1248 had molecular ions and ion fragment peaks
which were identical to those of Arodor 5460. However, the relative intensity of the spectral fragments of the various chlorinated tsrphenyl compounds is greater for tha higher ions representing chlorinated iaomars
9 MONS 088126
in the irradiated materials. The spectra of the irradiated Arodor 1254 in fraction II was composed of isomera of terphenyl from the pentachlorocerphenyls to the fully chlorinated (C^gCl^) terphenyl ion of 706 arau,
Cas clromatographic peaks were not observed for Aroclor*'5442 and 5460 under the conditions employed in the CLC-MS separation of the chlorinated biphenyl compounds. Polychlorinated terphenyla are produced during the irradiation exposure. These materials may result from free radical reactions of chlorinated phenyl fadlcals with chlorinacel biphenyl molecules. These ires radicals could be produce! by the recoil energy of (n,y) reactions of chlorine in che chlorinate! biphenyl molecules. The radioactive chlorinated terphenyla are sep arated from the chlorinated biphenyl compounds by the silicic add column. In our experiments, the radioactive chlorinated terphenyla were eluted by the more polar aolvent system; hexane-acetonltrilamethylene chloride. However, Armour and Burke (11) reported chlorinated terphenyl Aroclor materials were not recovered in the pesticide fraction but were eluted with 250 ml petroleum ether.
Radioactive and non-radieactive Aroclors and non-radloactlva ,'-1000610 of DDE, DDD and DDT were used to evaluate che separation of PCBs and pesticides with this silicic acid column chromatography technique. Seven percent of the ,'-DDE eluted in fraction I along with the PCBs (Table 3), The amounc of Aroclors eluted in che pesticide fraction was also determined. The elution volumes required to achieve the optimum separation of PCBs and pesticides (225 ml) should be determined for each preparation of silicic acid-Cellce 545.
10
*QNs oaai^7
CONCLUSIONS
Temperature-programmed gaa chromatography with SCOT columns should be seriously considered for use Co determine Che relscivs uptake in L'lological studies of Che various isomers in Aroclor formulatloia. We feel chac residues of PCBe composed of mixtures of Aroclor formulations can be analyzed by this technique. Each mixture is characterized by a particular Isomer pattern and contains Isomers not present in the Aroclor formulations of next higher or lover numb< r. A aeries of linear equati ons is required co determine che relaclce amounts of each Aroclor foraulaclon present. However, In biological or sediment samples these calculations would require knowledge cf changes produced in the Aroclor composition, an unknown factor at the present time.
prepared by neutron irradiation. Specific activities of 75-100 dpm/pig ware
The irradiated materials exhibited no detectable changes in isomer compos-tion when silicic acld-Celice 545 column chromatography la employed for purification. We assume chat Che radioactivity of the various PC3 isomers is distributed in the same manner as che probability of neutron capture.
The utility of using radioactive polychlorinated biphenyls in analytical methodology has bean demonstrated by the evaluation of the
11
MUMS O80U
procedure for chromatographic separation of PCBa and paacieidaa with (fh
silicic acid column chromatography. Only 1.6-percenc Aroclor 1248 aad 1.2-perceat Araclot(r3*0 1254 remained in the pesticide fraction and
/ 7 percent of the jg^-DDE eluted in the PCB fraction. The greateac benefit of these radioactive materials will become Apparent when results of biological uptake and metabolism studies with aquatic organisms are completed.
12 MGNS 0881^9
REFERENCES
1. Jensen, S., Johnels, A. 0., Olason, M., and Otterlind, G., meur. 224, 247--250 (1969).
2. Holmes, D. C., Simmons, J. H., and Tattoo, J. O'G., Nature
215, 227-229 (1967).
..
3. Koeoan, J. H., Tan Noever da Brown, M. C., and deVoa, R. U.,
Nature 221, 1126-1128 (1969).
4. Rlaabro-igh, S. W., Riache, P., Peakall, D. 0., Ha man, S. G.,
anl Kirven, M. N., Nature 220, 1098 (1968).
5. Jansen, S., New Scl. 32, 612 (1966).
6. Peakall, D. B., and Llncer, J. L., Btosclence 20, 958-964 (1970)
7. Cuseafs.m, C. G., Environ. Scl. Technol. 4, 814-819 (1970).
8. Lichtennteiu, E. ?., Schultz, K. R., Furremann, T. W., and Liang,
T. T., J. Econ. Entomol. 62, 761-765 (1969).
9. Papageorge, William B., Monsanto Company, presented In part at
a meeting "PCBs in the Environment" March 17, 1970, sponsored
by the National Water Quality Laboratory, FWqA, Duluth, Minn.
10. Reynolds, L. M., Bull. Environ. Contam. Toxicol. 4, 128-143 (1969).
11. Armour, J. and Burke, J., J.A.O.A.C. 53, 761-768 (1970).
12. Mlddladltch, B. S., Anal. Chem. 41, 2092 (1969).
13. Baglay, G. E., Relchal, W. L., and Cromartie, E., J.A.O.A.C, 53,
251-261 (1970).
oaai30
I
j
TT--'
Table 1. Enpcrical formula, molecular ulights and percent chlorine
' of chlorinated biphenyls and carphenyls. All calculecions based on -^^Cl.
Chlorinated Biphenyls
Eaperlcal formula
MW
ZCl
C12Uio C12H3C1 Ci2H8C12 fuhC13 C12H6C14 .C12H5C1s
154 0.00 188 18.62 222 31.53 256 41.02 290 48.28 324 54.01
..
c12h4C16 c12h3ci7 Cl22C18 Ci2H2C19 c12h0c110
3S8 392 426 460 494
58.66 62.50 65.73 68.47 79.85
' .
Chlorinated Tcrphenvls
Emperical formula
MU
ZCl
C18H14 . C18huC1 C18h12c12 C18H11C13 c18h10c14 CisHjCIj
230 264 298 332 366 400
0.00 13.26 23.49 31.63 38.25 43.75
c18h8c16 c18h7ci7
434 ' 468
c18h6c18 c18h5ci9
502 536
c18h4ci10
570
48.39 52.35 55.78 58.78 61.40
C18H3C1U C18H2c112 C18ll3 W0!*
604 638 672 706
63.74 65.83 67.71 69.41
088l31
mons
Table 2. Radioactivity produced by neutron Irradiation of Aroclor1248 and 1254.
Arodor Formulation sample (g)
1248
1.0
1254 1254 1254
0.5 0.5 1.0
Heut ron Flux,n/cmJ Exposure
4-5xl013
40 min
6-7xl012 4-5xl013 4-5xl013
6 hrs 36 min 40 min
Radioactivity
fraction
dpm
Recovery (mg)
Initial1 1 II
Total
initial I-A
initial I-A
initial 1 II
1.44x10 a.63x10 1.23x10 1.40x10
2.9x10 4.7x10'
1.25x10 2.69x10'
1.53x10 1.62x10 1.3x10
Total
1.48x10
995
265 425 975
Specific activity (dpm/)ig)
69.5
177 53 90.2
* Activity prior to silicic acid cleanup
7ETBR0 SNOW
Table 3* ?CB and }eatlclde recoveries vith silicic acid chronacogrsphy.
Fraction
Solvent
Volume(nil
Aroclot4^ 12481 <36C1)3
PCB
Petrols an
0-200
95
/ Schar
200-225 .
4
-/
225-250
__ 1
100
95.7 98.4
Pesticide c6hi4-ch3chCHjCIj
0-200
tr
total. Z 100
total. Pi 5
1.6 . 103
63
Z Recovery
1254 (36C11
95 4
... 1
100
97.6 1.1**
98.7
tr 1.3 100 100
5 51
Pcaticlde DDE3 DDD DDT
0 7-34 - 41 0 0
59 100 100 1Q0 100 LOO
5 33
^ Recoveries deeaT'nlned by gee liquid chromatography ^ Recovery detem.ned using ^Cl-radiolabalad notarial
x 2~i80a#ra of `)D2t ODD and DDT * TocaI in 200-250 ml eluace
i i i
\
MGNS 083133
i
ii
Figure 1.
'
CC-MS of Aroclot PCBs. SCOT CC-MS separation of Aroelor
material*. The underlined numbers designate the Aroelor formulation and numbers above the peaka designate the number
of chlorine atoms In the coapound(s) determined from the mass spectrum. Temperature program rate 2* C/min, He 9 palg, 50' x 0.020" SE-30 SCOT column, PE-270 CC-MS.
. o**vJl*
f
I
HUNS 088136
Figure 2* .
GC-KS of Aroclor PC3s. SCOT GC-MS separation of Aroclor
materials. The underlined numbers designate the Aroclor formulation and numbers above the peaks designate the number of chlorine atoms in the compound(s) determined from the mass
spectrum. Temperature program rate 2* C/oin 50' x 0.020" SE-30 SCOT colunn, PE-270 GC-MS.
9 paig,
i
TOTAL IONMOMTOR
...... J:
MONS 08813?
m
Figure 3.
RadiochromaCo grams from chin layer separations of neutron Irradiated Arodor formulations. Solid curves represanc Irradiated Aroclot1248 and 1234. Dashed curve represent*
the radioactive PC3 material eluting in fraction X from the silicic acid cleanup of the irradiated material.
/
i r
MQNS 088138
Figure 4.
SCOT CC-MS comparison of Arocloif 1248 and the radioactive
Aroclot*^ 1248 material eluted in fraction I of the silicic acid cleanup* Chromatographic conditions are aa described in Figure 1
MONS 0801^0
; -C,
Figure 5.
SCOT CC-MS comparison of Arocloi 1254 and the radioactive
Aroclor!'1254 macerial aluced in fraction I of cha silicic acid cleanup. Chroaacographie condition* afa described la Figure 1.
i
' -T '
mons oaai^d
i - / .: -
total ion monitor