Document OzBReqQjREbz2kgdeZrpBG9rw
Cconoco)
Interoffice Communication
To From Date
A. H. Sather J. V. Uptain May 8, 1978
//
J
Subject VCM DOSIMETRY RESULTS FOR APRIL, 1978
RECEIVED MAY 1 5 1978
Below are the results of VCM dosimetry for April. 114 samples were taken, three (3) of which show overexposure. All sampling was done using the REAL "Minimonitor" sampler.
Range, PPM
No. of Samples
%
0.0 - 0.5 0.5 - 1.0 1.0 - 5.0 5.0+
108 3 2 1
94.74 2.63 1.75 0.88
100.00
The three overexposures were:
Employee Job
Exposure, PPM VCM
Maintenance Supervisor
1.72
Yard Operator
7.9
Comments
Cause not yet determined.
Employee taking VCM com pressor down for maintenance Air-line respirator worn.
Vinyl Operator
2.68
Cause not yet determined.
jf
Attachment c: G. Draper
Department Heads D. Kuhn - Houston J. Hall - Houston 0. Steffey - Ponca City
/0
SAL 000108798