Document Oz86p6O6rpgXd7BKwexjD4VX
Heating Systems Boilers, Cast-Irot
United States Radiator (orporation
General OUices: Detroit. Michigan
Branches and Sales OUices in Principal Cities
Detroit, Michigan
CAPITOL RED TOP BOILERS FOR ALL FUELS________
Ratings in Sq Ft
Direct Cast Iron
Radiator Loads-- Sq Ft
"A" Series
"B" Series
C" Series
Steam-- 575-1450 Water-- 975-2475
Water--1980-5940
Steam--4700-10.500 Water--7760-17.325
280- 655 460-1085
550-2030 910-3350
1865-5805 3080-9580
Illustrated above is a Capitol Red Top. Series "C" Boiler. Capitol Red Top Boilers can be furnished with extra high steel bases to provide extra setting height or desired additional furnace volume for
stoker firing.
CAPITOL RED CAP BOILERS
For All Fuels
Direct Cast Iron
Boiler No.
Radiator Loads Sq Ft
Steam Water
19-4 300 19-5 350
495 580
20-4 20-5
400 450
660 745
22-4 22-5
500 550
825. 910
ISA 25-5
625 675
1030 1115
Capitol Red Cap Boiler design brings the advantages of (1) long fire travel, (2) flue passages that force the hot gases to circulate through every section, ex tracting the maximum heat from the fuel consumed. (3) Deep firepot that provides the extra space needed for better com bustion, and smooth, tapered firepot walls to assure a clean surface for better heat absorption.
CAPITOL SUNRAY BOILER No. I Series
Direct Cast
Boiler No.
.
Iron Radiatpr Loads Sq Ft
Water (Oil)
1-03 330 1-04 460
1-05 585 1-06 710
Water (Coal)
1-4 460 1-5 585 1-6 710
CAPITOL SUNRAY RADIATOR
Space Saving--Can be fully or partially recessed--Also well adapted for free stand ing installation.
Self-contained Cabinet Radiator--de-. signed to form its own enclosure.
The "No. 1" Series Capitol Sunray Boiler is furnished in Coal Burning and OilBurning types.
The unusually generous sized combus tion chamber is scientifically proportioned so that it will operate at highest efficiency.
The hot gases of combustion are forced with a swirling, scrubbing action directly against heat-absorbing surfaces.
982
Heating Systems Boilers, Cast-Iron
UnTtedStates Radiator (corporation
Genera! OUices: Detroit. Michigan
Branches and Sales OUices in Principal Cities
> . Detroit, Michigan
_ silea CO no no
--
too us
t
PS
,--07- ^ nirp^t standine Radiator Load Flue
CAPITOL FINCAST ENCLOSURES AND CONVECTORS
Made entirely of cast iron. Without joints--Cast in one piece. Many lengths and widths. Tappings, top, bottom and ends. Complete choice of enclosures. Finished to harmonize with modem
interiors.
CAPITOLAIRE DIRECT FIRED
CAPITOL THINTUBE RADIATORS
3-Tube
Heights
Per Section Heating Surface
25' f.65q Ft
4-Tube
19' 1.6 Sq Ft 22' 1.8 Sq Ft 25' 2.0SqFt
5-Tube
22' 2.1 Sq Ft 25' 2.4 Sq Ft
CONDITIONING UNIT
6-Tube
19' 2.3 Sq Ft 25' 3.0 Sq Ft 32' 3.7 Sq Ft
1$4 in. Centers.
40 per cent less space needed for these graceful, efficient Capitol ThinTube Radiators.
An air conditioning unit especially de signed for oil and gas firing. Streamline flue construction in preheating and primeheating sections insures high efficiencies. Deluxe jacket completely encloses all con trols, heating unit, automatic humidifier, filter and fan.
Other gravity and forced air furnaces available for gas, stoker or hand coal firing.
983