Document OdmapQ0NdEQnvL3w4EvqwKJe

Monsanto FROM (NAME ft LOCATION) J. N. Maloney - Pensacola ..Jrm I yy; t r! P Lift i. IftL. Textiles Division DATE SUBJECT REFERENCE TO October 24, 1969 - ^ - : - "' cc: * " Monthly Report, October,1969, Analytical Development C. R. Campbell . .. . .. : . ./ -. J : - : -- ; - . .... . -- ' ' T L. Broxton C E. Cutchens R H. Heidner R E. Sfellni! W E. Koerner J A. Lubkowitz J F. McGuffee W M. Sheffield c J. Webster T H. Woltdr Highlights - "Imine" blitzes in refined and blended HMD have been traced to diamine synthesis. They were caused by high levels of N-hexylazacycloheptane (HHMI)produced in crude HMD during a feed dis tribution test. Water samples from various locations in the plant and river have been analyzed for Arochlor 1254. -This monitoring will continue on a weekly basis. HMD I Summary Continued surveillance of crude HMD, using the new cyane extraction-VPC procedure, showed high levels ( 300mpm) of HHMI in 414B unit on September 24. Samples from other units at the same time analyzed less than 5 mpm HHMI. At this time a multiple feed injection test was being run on "B" unit while all other units were operating under standard conditions. Immediate term ination of the test unit prevented another "Imine" blitz in the refining system. Isolation and tentative identification of Naminohexylazacycloheptane and higher moJLecular weight polyamine homologs was carried out with crude HMD from this aborted test. The presence of these compounds, (at least 0.5%) supports the theory of poor reactanta mixing in -the test unit. - t PCB Analysis \ Thirteen samples have been analyzed showing periodic releases of Arochlor. 1254 from Bldg 408 into the east ditch. The decanter of Bldg 408 contained 6.5 ppm Arochlor 1254. Sinct, this decanter sporadically overflows into the east ditch it explains the variable range observed. Samples are now analyzed on a weekly basis. v Two electron capture detectors have been received and charac terized.for the analysis of Arochlor 1254 in aqueous streams. The tfitiunf detector was found to be more versatile in the analysis than the Nickel-63 detector since it- showed greater linear range and greater sensitivity. DSW 373138 IN*to REV. 11-68 STLCOPCB4098944 Maloney to Campbell - Monthly October 24, 1969 ' 2- Sample Load: September 16, through October 15. Proj ect: No. Samples: Chemical Support: HMD Pensacola NAOC EHD Catholyte PXD *' PCB HMI Conversion (W. A DBA Evaporator (J. J ADN, ACN,Caprolactam eckle) leks) 111 3 19 21 13 30 12 ___1 210 Nylon Salt The Ifluorescence spectra of nylon salt that meets plant specifications reveals two-regions of emission. The primary fluorescence occurs at 365 mu.- trhen excited with 295 mu energy. Data obtained to date indicate that the fluorescence impurities come from HMD. The fluorescence of nylon salt crystallized in the pilot plant was reduced from 0.98ppm to 0.06ppm as quinine sulfate. - Other preliminary data show that, pH will be 7.74 and all routinely measured impurities will be reduced by 2 to 10-fold. - STLCOPCB4098945