726 CHAPTER 68 had a temperature below zero. The temperature differential between the inlet brine and the return brine is an indication of the amount of heat being absorbed by the brine and thus the refrigeration load was computed. The shaft was about 1100 ft deep, 16 ft in diameter inside the concrete lining. According to the formation, the lining varied from 16 in. at the top to possibly 30 in. in the wet cone at 750 ft. Below 750 ft it was about 12 in. thick. BIBLIOGRAPHY . J. L Bowman: Quality control of mass concrete (The Military Engineer, September-October 1954, p. 347). R. W. Carlson: Temperatures and stresses in mass concrete (Journal of the American Concrete Institute, March-April 1938, p. 505). Cool concrete for Detroit dam; Part U bow low temperature concrete is produced (Engineering News Record, December 28, 1950, p. 31). Dams and Control Works (U. S. Department of Interior, Bureau of Reclamation, Washington, D.C., 3rd ed.). R. F. House: The Inundation Method of Cooling Concrete Aggregates at Bull Shoals Dam (U. S. A Corps of Engineers, little Rock, Arkansas, March 1949). R. Monson: Hinged cantilever forms permit high lifts on Table Rock dam (Contractors and Engineers, April 1956, p. 80). 1962 Guide And DatcrBook V. L. Peugh and Ivan Tyler: Mathematical Theory of Coolino Concrete Aggregates (Scientific Paper, March 20, 1934). v Refrigeration Manual for Concrete Mix Cooling Applications (Prepared by Hemminghaua, Inc., for C. 8. Johnson Co., lgjj, 54). P. Thompson: Precooled concrete in Chief'Joe dam (Rj. hugebattno Enginkebing, October 1954, p. 50). Glen Canyon Dam (Engineering News Record, May 11, 19R1 p. 34). Carlsbad Salt Mine (Western Construction, May 1952, p.-78). Contractor freezes canyon bottom down to bedrock (Pacific Builder and Engineer, March 1956, p. 74). Den freeze in Mexico (Western Construction, May 1952, p. 7g). C. P. Gail: The application of thefreezing method to shaft sinking (in Obtjxoay Salt Mine) (Canadian. Mining and Metallurgical Bulletin, September, 1954, d. 586). J. E. Lata: Freezing method solves problem in Carlsbad, New Mexico shaft (Mining Engineering, October 1952, p. 942). Robert Peele (ed.): Section 8. Shaft Sinking in Unstable Ground (Mining Engineers? Handbook, John Wiley and Inc., New York, VoL 1, 3rd ed., 1941). J. R. Peiikan: Refrigerated mud supports building during refoundations (Reitugehating Enginebeing, December' 1967 p. 51). Wet ground to sink deep shaft (Construction Methods and Equipment, November 1953, p. 84). C. J. Law: Soil freezing to reconstruct a railway tunnel (Proceedings, American Society of Civil Engineers, No. 2639, November 1960). CHAPTER 69 REFRIGERANT PIPING SYSTEMS--GENERAL Refrigerant line Sizing, Baas of Refrigerant Line Capacity Tables, Equivalent lengths for Valves and Fittings, Refrigerant Line Velocities and How Rates, General Piping Practice THIS chapter deals with the following general piping in terms of pressure loss at 100 F condensing temperature cor formation applicable to all refrigerants, although certain responds to approximately: epyific data covers only the commonly used refrigerants, 3.3 pai for Ammonia Rrfrigerants'12, 22, 500 and 717 (ammonia): 1. Refrigerant line sizing data. 2. Equivalent length* 0f valves and fittingB. 1.8 psi for Refrigerant 12 2.9 psi for Refrigerant 22 22 psi for Refrigerant 500 3. Refrigerant flow data. 4. General piping practice. Friction pressure drops in the liquid line include accessories Information concerning the physical arrangements of piping at and between the various system components can be found in Chapters 70 to 73. For information on piping materials and methods of pipe assembly, refer to Chapter 50 of the 1961 Guide And Data. Book. such as solenoid valve, strainer-drier, hand valves, etc., as well as the actual pipe and fittings, from the receiver outlet to the refrigerant feed device at the evaporator. Suction Lines. Pressure drop in the suction line means a loss in system capacity because it foroes the compressor to operate at a lower suction pressure to maintain desired evap orating temperature in the coiL REFRIGERANT UNE SIZING It is usually standard practice to size the suction line to have a pressure drop due to friction not any greater than the In refrigerant lines it is necessary, to consider the equivalent of about 1 F deg change in saturation temperature optimum sizes with respect to economics, friction losses and for arnmnniA, and 2 F deg for other refrigerants. In terms of oil return. pressure loss at 40 F suction temperature, this corresponds It is desirable to have line sizes as small as possible from the cost standpoint. On the other hand, suction and discharge fine pressure drops cause loss of compressor capacity, and excessive liquid line pressure drops may cause flashing of the liquid refrigerant with consequent faulty expansion valve to about: 1.48 pa for Ammonia 1.81 psi for Refrigerant 12 2.94 pa for Refrigerant 22 2.17 psi for Refrigerant 500 Operation. Oil return is not considered in ammonia system design. Therefore lines are usually sized for very low pressure drops. At suction temperatures lower titan 40 F, the pressure drop equivalent to a given degree change becomes less. For example, For other refrigerants, however, it is necessary to consider the requirements for oil return up vertical risers (see Chapter 70). (Text continued on p. 7SO) Oversizing of horizontal or vertical downward lines will have &o detrimental effect on system operation. Table 1 .... Approximate Effect of Gas Line Pressure Pressure Drop Considerations Drops on Compressor Capacity and Horsepower Liquid Lines. Pressure drop in liquid liTM** is not as critical &a with suction and discharge lines. The important things to remember are that the pressure drop should not be so exces sive as to cause gas formation in the liquid line, insufficient liquid pressure at the liquid feed device, or both. A system should normally be designed so that the pressure drop in the liquid line, due to friction, is not greater than that corresponding to about 1 F deg change in saturation temperature for ammonia, and 1 to 2 F deg for other refrig erants. A change of 1 F deg in saturation temperature, in line Pressure loss No Line Loss 2 F Suction line Loss 2 F Hot Gas Line Loss 4 F Suction line Loss 4 F Hot Gas Line Loss Compressor Capacity bp/Ton 100% 100% 96.2% 98.2% 103.1% 103.1% 92.2% 96.7% 106.9% 106.3% _ 727