Document OaBrgdL34r3Rq35yayeOBZXQ

Air PWkKfa and Chifflieili. Inc. Scar 53F A>*^swn. PA 1&105 t215> *81-1911 "mra 5 Dune 1986 Meredith Scheck SPI 155 Rt. 46 West Wayne, ND 07470 Oear Meredith: The revised draft VC guidelines are enclosed. These now contain the comments received through 27 May. Please distribute to the HSE Committee and ask that they get their comments back to me by 15 Duly. I will then prepare a clean copy for submittal to the Board. Very truly/tfobrs. DTB:pbr 0923c Enclosure: Draft VC Guidelines cc: M. R^-tfimura %y. Ferrara W. West Johfi y. Barr, Manager Regulatory Response AP00022526 DRAFT VINYL CHLORIDE: STORAGE, SHIPPING, AND HANDLING These recommendations have been prepared by the Vinyl Institute as a service to Its members and their customers and are based on Information believed to be accurate. No warranty or guarantee Is made for accuracy or completeness of the Information provided, and neither the Vinyl Institute nor Its member or contributor assume any responsibility for safe handling and for compliance with any applicable laws and regulations. Introduction Vinyl chloride and Its polymers have been In commercial use for more than half a century. The Safety Subcommittee of the Manufacturing Practices Committee of the Vinyl Institute has prepared these recommendations from the experience gained during that period so that those handling vinyl chloride might share the benefits of that experience. The excellent safety record of the Industry has been the result of strong and diligent efforts by the participants, and It should be useful to share the lessons which have been learned with others. Some useful background Information Is presented first, then a discussion of factors to be considered In the design and operation of storage and handling facilities follows. -1- AP00022527 Physical and Chemical Properties Relevant physical data are presented In Table I. Vinyl chloride Is generally quite stable chemically, but It is important to realize that the formation of unstable peroxides occurs readily in the presence of oxygen, particularly when water, add, Iron salts, or certain organic impurities such as acetaldehyde are present. These peroxides can detonate upon heating or under friction, and can Initiate polymerization under some conditions. One major producer has a limit of 1,000 ppm In the vapor phase, which has been found satisfactory. Table I Selected Properties of Vinyl Chloride Bolling Point Freezing Point Flash Point, Open Cup Autoignition Temperature Critical Temperature Critical Pressure, psia Explosive Limits in Air, 1 atm.p 25*C, Volume Percent Liquid Density at, *F, g/ml Vapor Pressure at, *F, psig Vapor Cloud Explosion Yield <lb. to yield the equivalent of 1 ton of TNT) F "C 7.0 -245 -108 882 317 -13.8 -154 -78 472 158 775 3.6 to 33 0 0.975 25 0.95 50 0.93 75 0.91 100 0.88 125 0.85 0 -4 25 n 30 30 75 39 100 60 125 78 150 96 24.305 2- - AP00022528 Toxicological Properties The most significant acute toxicological property of vinyl chloride is Its anesthetic capacity. This effect becomes Important at about 8,000 ppm, and can cause death after a short time at the low percent level. Cardiac arythmia has been seen in dogs anesthetized with vinyl chloride. Reversible liver enlargement was reported at exposures as low as 50 ppm in rodents for a few weeks. Liver cancer (angiosarcoma, ASL) has been seen In mice after a lifetime exposure at that same concentration, and In other mammals at higher levels. Workers exposed to concentrations thought to be approaching a few thousand ppm for several years also have'developed ASL. 'Some '32*deaths in the U.S. and about 115 In the free world have been reported from this cause. Acroosteolysis, a degenerative disease of the bone ends, also has been seen in highly exposed reactor cleaners In the past. No new cases have been reported recently. Vinyl chloride has a relatively high heat of vaporization, and thus large spills will liquify partially. This presents a hazard of frostbite to workers, as well as Increasing the fire danger. The odor of vinyl chloride Is too mild to be useful as a warning of its presence. Host persons cannot detect less than 1,000 ppm. -3- AP00022529 Regulatory Status Only a brief summary of the regulations pertaining to VC will be given here. Each manufacturer or user must become familiar with the details of the rules and develop a site-specific plan for compliance. OSHA Vinyl chloride is regulated as a carcinogen at 29CFR1910.1017. Extensive work practices, training, labeling, and recordkeeping requirements are detailed there. Some of these are discussed In later sections. The labeling requirements at 1910.1017 take precedence over the Hazard Communication Rule requirements at 1910.1200, but both rules must be followed, where possible. EPA Emission standards for VC manufacturing and polymerization facilities are found at 40CFR61.64. Here, too, work practices are specified, and preventable relief valve emissions are prohibited. Many states have assumed the enforcement authority for this rule. A recommended maximum concentration limit (RMCL) In drinking water has been set at zero (40CFR141.50), and an enforceable maximum concentration limit <MCL) of 1 ppb has been proposed. -4- AP00022530 Vinyl chloride, ethylene dichloride, and several of the wastes from their manufacture are listed as hazardous wastes under RCRA at 40CFR261. The interim statutory Reportable Quantity (RQ) for reporting a spill under CERCLA Is 1 1b. The final RQ value has not been set. The statute exempts "federally permitted" releases from the reporting requirements, but the ERA has not yet defined that term. FDA Polymers and copolymers of vinyl chloride currently are Generally Regarded as Safe (GRAS) for many food-contact applications and are formally approved at a number of places in 21CFR172, 175, 177, 179, and 181 when manufactured and processed in accordance with appropriate procedures. The FDA has proposed to establish limits of 5-50 ppb for residual vinyl chloride in the polymer used for such purposes. DOT Vinyl chloride Is listed as a hazardous material. Railcars for bulk shipping must conform to the specifications of types 105 or 112, Including head shields, spade couplers, and sheathed insulation. Details can be found In 49CFR173 and 179. Full and empty cars must be placarded, as is discussed In a later section. -5- AP00022531 Storage Vinyl chloride storage areas should be selected and designed to comply with all applicable local codes and regulations. Organizations such as The National Fire Protection Association, The National Board of Fire Underwriters, and the Factory Insurance Association can be consulted about proper site selection. Adequate separation between tanks and from other structures Is the primary concern. Conditions of Storage Vinyl chloride may be stored for reasonable periods of time without danger from hazardous decomposition or polymerization when kept in contact with ferrous materials and In the absence of air, oxygen, water, light, or excessive heat. Nitrogen blanketing may be required under some conditions to increase the storage pressure In order to facilitate tank pumping operations. Significant amounts of the nitrogen will dissolve in the liquid under these conditions. Refrigeration can be used in hot climates to maintain the storage temperature within a desirable range--below SO*F and preferably between 0*C and 20*C. In a few instances vinyl chloride Is stored as a cryogenic liquid. Steel Is the preferred material of construction for handling vinyl chloride. Stainless steel should be used for conditions where water may be present, such as In recovery and recycle operations. It has been reported that 316L Is -6- AP00022532 preferred In this service to prevent chloride-induced stress corrosion at weld lines, particularly if the service Is above 40"C and polymer deposition may occur. Cast iron Is not suitable for piping, pumps, or valves because of Its very brittle nature. Aluminum Is not recommended for use with any chlorinated materials. Copper and Its alloys are acceptable for Instrumentation parts, but stainless steel tubing Is preferred for major tubing runs because of Its superior mechanical properties. All-welded construction Is recommended whenever possible, except for connections to vessels, where flanges are preferred. `If'flanged construction Is needed, as in lines subject to polymer build-up, adequate electrical bonding and grounding Is necessary. The resistance to ground should not exceed 25 ohms. Threaded fittings (except for Instrument connections) are not recommended, and If used, should not be less than 1-172 In. In size. There should be no threaded connections on storage tanks. With either bottom- or top-entering Inlet and outlet connections. There should be remote actuated shut-off fire-safe valves at the tank connection. A section of plastic Instrument air tubing and an alr-to-open valve adds to the ability to assure rapid closure In case of a fire. All other tank connections should have a manual valve mounted directly on the tank flange. Excess flow valves cannot be relied on as adequate protection In either tank cars or storage tanks. The valve under the relief assembly must not close off all relief devices at one time. -7- AP00022533 The ability to flood a tank with water from the bottom also gives added protection against vinyl chloride releases because of mechanical failures In bottom-connected lines. Storage tanks should be painted with light-reflective coatings to reduce heat absorption. Support legs and at least the lower part of the tank should have fire-resistant coverings. The area should be diked to contain any liquid spillage, but sloped so that the pool Is not held beneath the tank. Consideration should be given to a remote method of Ignition of a pool should it develop. 'Storage tanks should have automatic sprinkler/deluge systems'of a type approved by the applicable local and national codes and actuated by temperature rise and/or vapor detection. Turret nozzles are especially useful for localized cooling In case of a fire. Design of the diked area should contemplate the volume of water or other firefighting liquid or foam which may be added. Liquid vinyl chloride would tend to float on any water or Ice, and the rapid vaporization from contact with the warmer water will Increase the rate of vaporization of the vinyl chloride, which then will freeze large quantities of water with considerable trapped vinyl chloride vapor. Adequate separation should be allowed between storage units for effective maintenance or fire fighting, and to prevent excessive heat transfer in case of fire. Maximum feasible separation should be provided from sources of Ignition such as furnaces, maintenance areas, or non-endosed electrical stations. -8- AP00022534 A design working pressure of about 150 pslg is advised for non-refrigerated systems. Hydraulic relief valves or equivalent protection should be considered for all pump casings and piping sections which could be isolated by valving off from the main storage vessel. Pumps are required by ERA to have pressurized double mechanical seals, to be sealless, or to have some other equivalent leak prevention system. High temperature rise protection is desirable for the pump casing. Adequate pressure relief valves for fire conditions should be placed on the main vessel. Dual systems with a 3-way transflo valve on the tank which cannot close off both systems at the same time are useful for maintenance. The EPA standard requires that a rupture disk be present before all pressure relief valves which are not vented into a recovery or abatement system. Such venting can be used for hydraulic relief valves which will be called on to vent only small volumes, but should never be used on primary storage vessel relief systems. There the relief valve tall pipe should be as short as possible, with no more than one elbow. Storage tanks must be labeled as required by the OSHA standards, as well as meeting any local rules. Miring In the storage area must meet applicable national or local codes, and should conform to Class I, Group D, Division 1, as a minimum. Other areas generally qualify for Class I, Division IX. -9- AP00022535 Panel-mounted sight glasses with 1Ight-absorbant glass are preferred to the stand-off tubular type gauges. If the latter are used, the check valves and glasses should be Inspected regularly. Remote Indicating (redundant) metal systems are preferable to either glass type. Redundant flowmeters of a reliable type (e.g. tankline meters) are very useful In preventing accidental overfilling of tanks and reactor. A detailed preventative maintenance program should be developed which assures bench testing of relief valves, pressure gauges, level Indicators, and other such critical devices used In the handling of VC on a regular basis. A testing program for pressure vessel wall integrity and for major rotating equipment also'ls valuable. A written record should be maintained o'f all' inspections and tests which are performed. Bulk Transport Bulk transport vehicles should be inspected for mechanical Integrity and to insure the Identity of their contents before they are connected to the loading/unloading station. The station equipment should be Inspected carefully before each use. Defects should be reported at once, and no attempt should be made to load or unload until the defect is remedied. The Department of Transportation requires that loading and unloading operations to be under constant surveillance. -10- AP00022536 Bulk vessels should be dedicated to vinyl chloride service, and should be maintained under positive pressure at all times to prevent entry of air. If nitrogen padding Is used to assist unloading In very cold weather, the supplier should be informed by that fact before the vessel Is returned. No container should be filled to more than 85X liquid full. The design of the loading/unloading station should provide sure footing for the operator In all types of weather, and conform to OSHA standards for elevated work platforms. Proper counterbalancing and support of the hoses and ' connectors Is needed to reduce operator effort and to assure tight connections. Top unloading vessels should be used. Consideration should be given to the drainage of any massive spill away from the major operating area. The location of the station should provide adequate separation from other operating areas, and minimize the pipe runs to storage. It should be as far away from major traffic areas as feasible. The preventative maintenance program should Include the loading arms as well as the other equipment In this area. Many employers require the use of appropriate protective gear while connecting and disconnecting loading lines, pumps, and during other operations where large concentrations of VC may occur. OSHA requires such protection (29CFR1910.1017) where liquid may be encountered. A safety shower/eye fountain should be located within easy access of all loading/unloading stations. -11- AP00022537 CHEMTREC should be notified Immediately at 1-800-424-9300 of any transportation or other emergency Involving vinyl chloride. The Superfund National Response Center (800-424-8802) should be notified of any spills or releases to the environment above the reportable quantity. Railcars. Accumulation or storage of railcars containing vinyl chloride, either full or empty. In areas accessible to the public should be avoided, If for no other reason "than to avoid public concern. The Compressed Gas Association has developed an emergency dome repair kit for field use when leaks develop in that area. Pamphlet P-10 is available from the CGA in Washington, D.C. Shippers and users should become familiar with the nearest location of a kit. Many VC producers also have developed emergency capping kits and field valve change-out procedures. Each user of VC should discuss with its suppliers the procedures and facilities available for emergency situations before the problem arises. Many Vinyl Institute members participate in CHEMNET, a mutual aid organization that will provide advice and suggestions for abstaining field assistance, if needed in transportation emergencies. It can be contacted through CHEMTREC at 800-424-9300. The evaluation of disposal methods for vinyl chloride from cars Involved in serious train accidents must be done on a case-by-case basis. Several recent events have been resolved safely by piercing the derailed car with a shaped charge, followed by Ignition of the venting gas. -12- AP00022538 Derail devices or a locked switch and warning signs must be in place whenever railcars are connected to the station. Brakes must be set and the wheels blocked whenever the car Is connected. Bulk Tracks. It Is particularly Important to observe the electrical grounding and chocking rules for trucks during their unloading. If the tractor unit Is to be moved. It should be done before the unloading operation; and not returned until the connections are purged and open. Clearances of at least two feet on each side and four feet on each end of the trailer are desirable. The station should have a level, smooth pad that Is curbed and drained away from the trailer and pump station. Marine Movements. Coast Guard rules apply to shipments by water. The principles for safe handling are not substantially different for this than for rail or truck movements, of course. The larger quantity Involved calls for a proportional degree of care being applied. Cylinders. No cylinder should be filled with vinyl chloride or any other substance without expressed permission from the owner. Cylinders for shipping vinyl chloride are regulated by the DOT under rules found at 49CFR173 and 304. The outlet valve(s) must have a suitable protective cap. Cylinders with brazed seams are not permitted; seamless cylinders are preferred. Maximum allowed flUage Is 8VL. The same general labeling requirements apply to cylinders as to other containers. Cylinders whose Inspection expiration date has been passed must be tested and inspected before the next refilling. Only pressure reducers designed for VC and having the proper threads should be used. -13- AP00022539 Manifolds or piping systems should have proper pressure relief devices and an effective check valve so that other materials cannot be backpressured into the cylinders. Sample Containers. Sample containers that are to be shipped in Interstate commerce must meet the conditions referred to In the preceding paragraphs. Cylinders for local use should be of no less quality, but will be lighter and smaller, generally. Double-valved cylinders are preferred In order to be suitable for the pass-through sampling system required by the EPA standard. Samples not exceeding 300 lbs. may be shipped by cargo plane, but not in passenger planes, or as luggage. See 49CFR173.304, .314, and .315 for details. Labels Labeling requirements of the DOT can be found at 49CFR172.101(e>. Each container must have on it a label or placard Identifying the contents as VC, a flammable gas, and using the Identification number UN1086. ''Empty" vessels must have a placard reading "Residue" and giving the UN1086 Identifier. See 49CFR172.203, et. seq. OSHA requires (29CFR1910.1017> that all areas where exposure may exceed 0.5 ppm on an 8-hr. average be posted with "Cancer-Suspect Agent Area, Authorized Personnel Only" signs, and all stationary containers of VC labeled "Vinyl Chloride. Extremely Flammable Gas Under Pressure, Cancer Suspect Agent." -14- AP00022540 Shipping containers must be labeled In accordance with 49CFR170-189, and "Cancer Suspect Agent" added near the placard. Containers of PVC, Including shipping vessels, must be labeled similarly, unless specifically exempted from the OSNA rule. Emergency Response The first action In case of an emergency outside a manufacturer's or user's facility should be to notify CHEMTREC at 800-424-9300 and the local authorities, most often the State Police, In order to set In motion the extensive assistance mechanisms which are available. Releases which are regulated under Superfund should be reportedto the National" Response Center at 800-424-8802. Inside a regulated facility there Is required to be In place a detailed emergency response program. This should be Initiated as quickly as an emergency Is recognized. OSHA forbids entry Into areas with concentrations over 36,000 ppm (3.6%--the lower explosive limit) except for rescue, even with full protective gear. This prevents some response actions that may have been considered acceptable In the past such as plugging small holes or changing a valve "on the fly." Real emergencies seldom Involve such small occurrences, and broader actions usually are required. -15- AP00022541 While awaiting professional assistance, some actions can be begun: 1. Injuries, Injured persons should be removed as far from the site as the Injuries allow. 2. Traffic control. Set up barriers to prevent entry by untrained persons to the site. 3. Evacuation. Consideration should be given to warning or evacuating at least a quarter- to half-mile radius around a railcar or bulk truck to avoid flying fragments In case of an explosion. Geographic or weather conditions may suggest other distances as more desirable. 4. Response headquarters. A safe but usable site for response headquarters should be selected and responders directed to it. % 5. Fact col lection. An effort should be made to preserve as much information on the cause and results of the incident as Is feasible. 6. Authority. As response develops, it.is important that one person be given the overall authority. The official function of that person will vary from state to state, and conflicting activity must be avoided. Neither consignees nor shippers usually take a decision-making position, but can be valuable advisors. -16- AP0b022542 Persons responding should have, as a minimum, the following equipment: 1. Protective clothing and NIOSH-approved self-contained breathing gear. 2. Vapor detection devices usable In the ppm and percent ranges. 3. Appropriate outdoor clothing. 4. Ropes, traffic warning devices. 5. First aid gear. 6. Portable radio. 7. Portable lighting. 8. Capping or plugging equipment. Anyone responding should be prepared to stay several hours at the site, and should have replacement or backup personnel assigned. Every event must be evaluated on a case-by-case basis, thus relevant experience Is of great value. Hazards presented by other containers or vehicles Involved In the accident can be of great significance. Concealed damage may be a problem not recognized at once. Mater may be useful to cool equipment, but Is not an effective fire control medium, and may only spread other substances Involved. Fires should never be extinguished unless the source of the fuel has been controlled. Flashback from reignition at hot surfaces is a real danger at the fire scene, and It is very probable that If a vapor cloud is allowed to escape It will find a source of ignition, with the resultant major damage from such an explosion. -17- AP00022543 If there is danger of a loaded car rupturing from external heat, or if it does not appear possible to right the car or transfer its contents to other vessels safely* serious consideration should be given to deliberate piercing of the shell and simultaneous ignition of the contents. This has been used successfully In several Instances. 2009C-FI -18- AP00022544