Document OJEKqNLXqkZ40Jk8o789MxpVK

Gollob Analytical Service Corp. ------------------- Mass Spectrometry Gas Chromatography Leak Detection -- TO: Mr. Borch Amboy Terminaling P. O. Box 825 Perth Amboy, New Jersey 08861 47 INDUSTRIAL ROAD BDUEJEY HEIGHTS. NEW IERSEY 07922 TEL (2QU 4&4-3331 ANALYTICAL REPORT NO. G.A.S. 32590 A MATERIAL SUBMITTED: Date Reported: 12/16/74 Date Requested: 12/10/74 P.O. No. Verbal Monitoring for VCM exposure. INFORMATION REQUESTED: Gas Chromatography Analysis. NOTEBOOK REFERENCE: NB 346 page 22. RESULT OF INVESTIGATION: This is a continuation of the study performed by Gollob Analytical Service personnel at Amboy Terminaling on December 9, 1974. During this segment of the investigation employees were moni tored during non-routine operations deliberately simulating maxi mum possible peak exposure. All data are presented in the table. Employees Monitored /4.?~ r~&6^C M. Younqhams-Staindinq on platform during the filling of hopper truck with VSKK10 resin Exposure Time 0949-1045 VCM* .44 A. Ampe-Weldinq experiment in Rm. 1 PVC Duct intentionally left in area of the welding, operation___ S.S.4rHf-30 -S^96 G. Mandv-Stanainq on platform of Hopper # 1 simulating the changing of filter bags 1050-1057 1055-1110 2.7 63 Note? Sample collected, on NIOSH approved Lot #5 Charcoal, with Sipin & SKC pumps calibrated at 64.5 and 57.1 cc/rainute respectively. VCM- Vinyl Chloride Monomer Concentration ppm Volume/Volume ach 12/23/74 Gollob Analytical Service Corp. ---------------------- Mass Spectrometry Gas Chromatography Leak Detection TO: Mr. Borch Amboy Terminaling 560 State Street Perth Amboy, New Jersey 08861 BERKELEY HEIGHTS. NEW JERSEY 07922 TU.. 1201) 48*4331 ANALYTICAL REPORT NO. G.A.S. 32590 MATERIAL SUBMITTED: Date Reported: 12/16/74 Date Requested: 12/10/74 P.0. No. 74-3368 Monitoring for Vinyl Chloride Exposure INFORMATION REQUESTED: Gas Chromatographic Analysis NOTEBOOK REFERENCE: NB 346, page 22 RESULT OF INVESTIGATION: On December 9, 1974, Messrs. L. Molinini and J. Traina i. of Gollob Analytical Service visited Amboy Terminaling and moni tored two employees for eight hours to obtain a time weightedaverage for vinyl chloride exposure. In addition, gas samples were taken in special evacuated glass containers from several areas in the warehouse. The results of the warehouse sampling are reported separately under G.A.S. 32588 dated 12/9/74. All monitoring data are presented in the following table. Continued Page 1 of 2 Pages dm 12/23/74 RNW20642 By. GOLLOB ANALYTICAL SERVICE CORP Mr. Borch Amboy Terminaling -2- G.A.S. 32590 Personnel Monitored 150-1*- ?.} J. Smock - Room 2 Bagging VYFS resin Approximately 648 bags filled during this monitoring Time 0810-0910 0912-1009 1013-1113 1114-1158 Switched at this time 1235-1330 from bagging PVC to filling polyethylene 1333-1430 containers 1434-1530 1532-1615 Vinyl Chloride Monomer Concentration ppm Volume/Volume .17 .22 .45 TWA .47 70 66 59 y -if9? P. Bulla - Room 1 Bagging VSKK10 Approximately 965 bags filled during this 8 hr. monitor ing period 0812-0912 0914-1013 1015-1114 1118-1157 1235-1332 1334-1431 . 26 .36 .71 .80 1.1 1.1 (T.TWA 47 1436-1532 6.2 1534-1615 1.3 J Note: Samples were collected on NIOSH approved charcoal tubes, Lot #5, with Sipin and SKC pumps calibrated at 64.5 and 57.1 cc/ minute, respectively. Each tube was in service for approximately 60 minutes. RNW20643