Document OJDK0X71e5o401MNQj9dwnRGQ

-2- Asst, to Chief for Epidemiology and Pi eld Studies, DOH -- .4/8/66 At the Kahwah laboratory a number* of brake testing dynamom eters were available which could simulate various operating conditions. These machines were set to test a variety of typical brakes and air samples of the decomposition products were taken on membrane filters. Electron micrographs were made of the deposits thus collected and a number of fields were scanned for the presence of fibers. Where significant numbers of fibers were found an estimate of the fraction of the decomposition product which was fiber was made by sizing all of the particles and fibers seen. The results of these tests are as follows: Decomposition of Brake Linings No. Type of Brake Condition of Presence Test of Fibers 1 Disk Brake Normal:' driving Few 2 Bus Brake City driving None 3 Automobile 100-200 P drum Few temperature 4 Automobile Brake 300-500 F drum temperature * 5 Automobile Brake 600-700 F drum Numerous temperature 6 Automobile Clutch Normal driving None 7 Bus Brake 450-550 P drum None temperature 8 Automobile Brake 100-300 P drum None temperature 9 Automobile Brake 400-600 P drum Few .-V*T temperature 10 Bus- Brake 450-550 F drum None temperature % Fiber (mass) <5 0 *0 <1 15 0 0 0 r'O 0 One clump of fibers still largely coated with binder and having a roughly rectangular shape. 1 011951 JWK007834