Document OJ790LK0YZLZO74zJXzMYVK3Q

Monsanto . FROM ANNISTON, ALABAMA DATE SUBJECT January 6, 1966 Aroclor GLC Analysis REFERENCE TO D. R. Middleton WGK cc. Messrs: . R, Savage D. C. Armstrong D. E. Harris J. A. Mullendore L. C. Fuhrmeister R. Taylor 0. E. Dolin The sample of Aroclor 1242 (Lot KE 474) received from you January 4, 1966, has been analyzed and the data obtained is listed on the attached sheet. Three trials were made to check precision and increase accuracy. To test the reproducibility of the column used in the GLC analyses, a periodical check on the column was made. This check consisted of analyzing a given sample repeatedly o^er a period of time. Changes in the column performance resulted in a variability of +5% of the amount present in the 20 to 35 per cent range. Copies of the chromatograms are available from the laboratory records. /dp Att. J. A. Liddle DSW 248346 STLCOPCB4054057 STLCOPCB4054058 Peak Number 1 2 3,4, & 5 6&7 8 9 & 10 11 12,13,14, & 15 16,17,18,19 & 20 21,22,23, & 24 25,26,27, & 28 29,30, & 31 32,33, & 34 35,36,37,38,39, & 40 41 & 42 ' 43,44, & 45 46 47 can 48 ro 4^ 49 S 4^ -sj Trial One o.io 0.08 0.03 2.90 0.31 8.78 1.07 27.46 Lot KE-474 (No basket, Lime Treated) - Trial Two Trial Three Average 0.11 0.13 0.11 0.09 0.09 0.09 0.03 0.03 0.03 2.89 2.89 2.89 0.31 0.32 0.31 7.71 8.59 8.36 1.07 1.10 1.08 27.48 27.34 27.43 34.98 6.62 9.11 5.53 2.13 0.60 0.17 0.10 0.02 Trace Trace Trace i 35.55 6.86 9.23 5.60 2.12 0.61 0.19 0.09 0.02 Trace Trace Trace 35.33 6.80 9.22 5.19 2.09 0.60 0.19 0.09 0.02 Trace Trace Trace 35.29 6.76 9.19 5.44 2.11 0.60 0.18 0.09 0.02 Trace Trace Trace Known Isomer Biphenyl 2-chloro 3-chloro 4-chloro 2,2'; 2,6 2,5; 2,4 V . 2,3'; 2,4'; 2,3 3,5 3,4; 3,4'; 2,5,2; 4,4'; 2,3,2' 2,5,4'; 3,4,2'; 2,3,4' 3,4,4*