Extract from the reference list of FRIOTHERM heat pumps with numbers of operating hours
Installation
Vrtan Ropsten Sandvika 1 Kista Akalla Lysaker Nimrod Fornebue Fornebue 05 Sandvika 2 Skoyen 05 Skoyen 07 Katri Vala Turku I
Type d'UNITOP
50FFE
28/28CPY 33/28CY-8129U 28/22BY-8107U 33/28CPY-10149U 28/22CY-8117U 33/28CPY-10149U 33/28CPY-816118U 50FY-101711U 34FY-81411U 50FY-81912U 50FY-81912U
N of HPs
6
2 2 1 4 1 1 1 1 1 5 1
Year of delivery
1984 (4) 1986 (2) 1988 1998 1998 2000-01 2000 2005 2008 2006 2008 2005 2009
City / Country
Stockholm / SE
Sandvika / NO Stockholm / SE Lysaker / NO Stockholm / SE Fornebue /NO Fornebue /NO Sandvika/NO Oslo / NO Oslo / NO Helsinki / FI Turku / FI
Evap. regime
2.5/0.5
10/6C 14/4C 5/2C 8.5/6C 5/2C 5/2C 8.7 / 4 C 10/5.8C 10/6.3C 10 / 4C 9 / 2.8C
Cooling capacity
6 x 20'000 kW 6 x13'500kW* 2 x 4'750 kW 2 x 6'000 kW 1 x 3'000 kW 4 x 9'000 kW 1 x 3'600 kW 1 x 5'600 kW 5'200 kW 11'840 kW 6'000 kW 5 x 12'000kW 11'900 kW
Source froide
Sea water
Sewage water
District cooling
Sea water ind. Sea water ind. Sea water ind. Sea water ind. Sewage water Sewage water Sewage water Effluent ind. Effluent
Cond. regime
57/80C
57/78C 58/81C 50/75C 68/78C 50/75C 50/75C 54 / 78 C 75 / 90C 60 / 75C 58 / 88C 45 / 85 C
Heating capacity
6 x 30'000 kW 6 x 20'000 kW* 2 x 7'000 kW 2 x 9'125 kW 1 x 4'500 kW 4 x 9'000 kW 1 x 5'400kW 1 x 8'300 kW 8'000kW 18'400 kW 9'200 kW 5 x 18'110 kW 18'000 kW
Approx. number of operating hours
180'000
230'000 120'000 150'000 100'000 120'000 100'000 100'000 110'000 100'000 100'000 90'000
* cooling/heating capacity of UNITOP 50FFE after retrofit from R22 to R134. The customer plans to operate the Vrtann Ropsten heat pumps until 2050.