Document OEjzo4d44NJQOXq7qybpQ7gyM

0 C'Lv*. b(&.cf<) 2 PYDRAUL Fire-Resistant Hydraulic Fjuid 0 SELECTOR A guide to selecting the cor rect Pydrau I fluid for hydraulic systems. O/FF-3 Monsanto CLv. &/. TOWOLDMONOQ35385 lH'f' ':,kV'..).1111?MijJi'l'^lHStMB PYDRAUL fluids Development Fire protection for industrial hydraulic opera tions began with Pydraul in 3951. Pydraul fluids have since provided industry with millions of machine hours of safe operation. Pydraul fluid has never caused a fire--not even when sprayed from broken high pressure hydraulic lines onto white-hot surfaces. New ways are continuously being explored to improve the excellent performance records of Pydraul fluids. From the first Pydraul fluid, (Pydraul F-9) the family has grown to a dozenplus specially tailored, fire-resistant safety fluids. Each answers a major but specific hy draulic fluid need for industrial use. In addi tion to guarding against fire, each Pydraul fluid lubricates as well as premium grade oil. Pydraul fluids have answered the need of vir tually every industrial hydraulic operation, in doors and out--from the sub-zero, outdoor hy draulic lift operations for refineries and blast furnaces to the low-viscosity fluid demands of high-speed, precision machine tools. 1 Performance Pydraul fluids offer a wide range of viscosities from which you can select the proper range speci fied by your hydraulic equipment manufacturer. Whichever Pydraul fluid you select, each pro vides the same protection against fire, premium lubricity, ease of maintenance, and freedom from corrosive action and foam. Pydraul hydraulic fluids also offer several additional benefits-- Cfjj yldp+0[reduced FIRE INSURANCE RATES Pydraul eliminates fire hazards from hydraulic operations, reduces fire threats to surrounding structure and equipment. Insurance premiums for plants using Pydraul are often lower than premiums for operations using petroleum oil. LONGER PUMP LIFE Machines which operate on water-based fluids frequently require pump repair or replacement as often as every two or three months. Machines which use Pydraul hydraulic fluids can operate on the same pump for several years. Pydraul hydraulic fluids give the same long pump life as the finest grade petroleum oil. NO CORROSION PROBLEMS Any metal hydraulic system component in con tact with Pydraul will not rust. Pydraul hydrau lic fluids do not lose anti-rust properties even after extended use. MAXIMUM EQUIPMENT RESPONSE Pydraul never produces excessive froth or foam during normal operations to interfere with hy draulic equipment response. Because Pydraul hydraulic fluids lubricate as well as premium petroleum oils, Pydraul permits equipment to operate at optimum response capability. INSPECTION AND REPLACEMENT DOWN-TIME ARE VIRTUALLY ELIMINATED Pydraul hydraulic fluids are designed to be permanent. Pydraul fluids do not wear out. Ex cept for normal "make-up" requirements, you never have to add new Pydraul to hydraulic systems. Pydraul eliminates "drain and change" periods; it does not have to be inspected in your system from month to month--or replaced from year to year. $ 05V01<>* i TOWOLDMONOQ35387 PYDRAUL Selector One r physicaO^operties Appearance Spec. Gravity 257257. Neutralization No. (acidity) (mg I* Moisture (max.) 'gm) max. VISCOSITY Centistokes(?/; 1007. 2107. Saybolts as(<i 1007. measured: 210F. "Absolute Saybolts" ( 1007. (SSU x Density) 2107. Pout Point Compressibility x \0-` sq. in./lb. Bulk Temperature Max. (lor continuous operation) Boiling Point 7 8t 760 mm Hg. Coelticient ot Thermal Expansion per 7. Specific Heat BTU/lb./7. ( 777. Thermal Conductivity BT U/hr./ft./0F. Vapor Pressure mm Hg(n 2007. Bulk Modulus /Room Temp.\ ( 1000-6000 ) V psi / Solubility in Water EIRE RESISTANCE TEST High Pressure Spray Test <AMS-3150C and Federal Test Method Std. 791) Test fluid sprayed at 1000 psi through orifice, passing through flame of oxyacetylene torch, 60007. Low Pressure Spray Test (AMS-3150C). Test fluid sprayed at low pressure over ignited, oil-soaked rag to determine degree of increase in flame intensity. Hot Manifold Test (Federal Test Method Std. 791). Test fluid dripped on at 13007. Molten Metal Ignition Test. Test fluid exposed to the surface of aluminum alloy at 12007., to test for spontaneous ignition. PYDRAUL F-9 Cloudy Blue Liquid !.280-1.295 0.10-0.35 0.20% 43 to 53 cs 5.0 to 5.8 cs 225 SSU 43.3 SSU 327 SSU 52 SSU --57. ^__ 2.58 2257s. 6647. 0.00041 0.32 0.067 0.013 387,000 Negligible PYDRAUL A-200 Cloudy Blue Liquid 1.415--1.430 ' 0.80-1.10 ' 0.05% 30.0 to 33.0 cs 2.8 to 3.0 cs 144 SSU 35.7 SSU 204 SSU 48 SSU 4 157. 2.28 2507. 6207. 0.00040 N. 0.28 0.068 \o.? 438,00cNv Negligible Does not flash or ignite up to 3`A feet from orifice. No increase in flame intensity^ Does not flash or burp* D_p*s" not flash or ignite up to 31/? ^eet from orifice. Slight increase in flame intensity. Does not flash or burn. Does notigfme: flashes by spark. Does not ignite. Fire-resistance Advantages of Pydraul Pydraut fluids protect hydraulic equipment and persi nel with permanent fire protection. Pydraul fluids cont; no wafer to evaporate and leave a flammable rej ' During their millions of hours of machine use/^draul fluids have been accidentally sprayed over molten metal, through electrical arcs, into flames and^ffarks--without causing fire. Pydraul fluids have neydr caused or con tributed to a hydraulic fire in ajj/iype of equipment. They pass all of the importapt'tgnition tests for fire' resistance. Monsanto introduced Pydraul F-9 as industry's first straight synthetic, fire-resistant hydrau lic fluid. Pydraul F-9 rapidly be came the standard against which all other synthetic hydraulic fluids were judged. Today, it is still considered the basis for comparison. Pydraul F-9 is used in every major type of diecasting machine and a wide variety of other equipment found in the metal-working, glass, and pro cess industries. No other fireresistant hydraulic fluid has more on-the-line proven per formance to offer. Pydraul F-9 is listed by Underwriters Lab oratories for use in hazardous hydraulic applications. It is also approved by Factory Mutual and U.S. Bureau of mines. Pydraul A-200 is one of the most widely used, general-purpose, fire-resistant hydraulic fluids in industry. Introduced in 1959, it was the first fire-resistant, straight synthetic hydraulic fluid to break the "price/per formance barrier." Pydraul A-200 performs like premium-grade petroleum oil in a wide variety of industrial ap plications, from die-casting to aluminum extrusion. It protects plants and personnel with chem ically "inherent" fire-resist ance, yet costs less than other straight synthetic fluids. Pydraul A-200 is approved by Factory Mutual. TOWOLDMON0035388 IX ptjjfji PYDRAUL 280 PYDRAUL 625 Cloudy Blue Liquid 3 1.385--1.405 | 07-0.5 0 0.15% Cloudy Blue Liquid 1.360-1.400 0.30 0.15% 5G to 62 cs 3.9 to 4.1 cs 274 SSU 39.1 SSU 38? SSU 54.5 SSU H?DT ?,47 yT y 225r. yr MflMO yT 078 S' 0.066 0.15 406,000 Negligible 125 to 145 cs 5.7 to 67 cs 625.7 ^7|5$SU 59 SSU 430F. 2.66 225*F. 724f. 0.00040 0.28 0.065 0.009 375,000 Negligible PYDRAUL 150 Cloudy Blue Liquid 1.120-J^T yS^ 0.10% 29 to 34 cs 6.9 to 8.1 cs 145.9 SSU 52.9 SSU 163 SSU 56 SSU --55F. 3.13 ` 150F. 617F. 0.00042 0.40 0.072 0.01 319,000 Negligible PYDRAUL 60 Cloudy Blue Liquid 1.088-1.091 0.25 0.10% 9.6 to 10.4 cs 2.3 to 2.5 cs 60 SSU 35 SSU 60.5 SSU 35 SSU --70F. , 3.05 175F. 707 r. 0.00044 0.42 0.047 0.002 328,000 Negligible Hast) ot ignite up to 3'/? feel fiofruuifice. Veiy slight inebs^se in flame in tensity. Poes not flash of bum. Does not flash or ignite up to 31/? feet from orifice. Very slight increase in ttame in tensity. Does not flash or burn. Does not ignite. uOav^nodgnite. Self-extinguishing. Slight increase in flame intensity. Intermittent flashing and burning. Little burning in pan below. Does not ignite. Self-extinguishing. Slight increase in flame intensity. Intermittent flashing and burning. Does not bum after leaving tube. Does not ignite. Pydraul 280 is a shear stable, higher viscosity medium range safety fluid. Developed spedtically for hydraulic clutches in Gorman coal mines, Pydraul 280 has proved successful in a variety of hydraulic applications including diecasting machines and automatic welders. Blended to provide a fluid with a viscosity range between Pydraul A-200 and Pydraul 625, Pydraul 280 is now performance-proved with qualities equal to those of the tong accepted Pydraul fluids. Pydraul 280 Is approved by factory Mutual. High viscosity "fyd/aul 625 is Pydraul 150 is used in hydraulic Low viscosity Pydraul 60 flows tailored for ultra-heavy-duty hy- systems to control fuel-to-air freely at --20F. It retains its draulic operations, such'for ratios for blast furnaces, soak- properties and thermal stabil- large industrial presses ing pits, and other similar re- ity at temperatures up to 200 pumps. Pydraul 625 is also used 'v, lated equipment. Although de- F. In hydraulic operations that asa fire-and-explosion-resistant air compressor lubricant. Py- v-veloped especially for severe cottj'Weather, outdoor opera- require precision flow ir>s(antly, Pydraul 60 supplies smooth draul 625 can be used in any tionsrPydraul 150 is also used operation from machine start to equipment requiring an 800 for certain missile-launch pro- to 1000 SSU oil. jects and in gears of LOX pumps stop; it offers flow-on-demand operation without hydraulic lag. Pydraul 625 has all the good located in oxygen-jich atmos- Pydraul 60 offers excellent. performance characteristics pheres at missile-fueNog sites. fire-resistant, hydraulic opera- which have won Pydraul fluids Pydraul 150 also performs** an tion with vane, gear and piston the reputation of quality and excellent low-viscosity fluid for pumps in high-speed machine dependability throughout in- high-speed machine tools. ^ 'stools. dustry. In years of industrial field use, Pydraul 625 has proved to be a top-grade lubri cant. Pydraul 625 is approved by Factory mutual. 3 OSlOiVb TOWOLDMONOQ35389 TOWOLDMONOQ35390 VISCOSITY, SAYBOLT UNIVERSAL SECONDS VISCOSITY, SAYBOLT UNIVERSAL SECONDS KINEMATIC VISCOSITY, CENTISTOKES -70 -60 -50 20 00' loom 5 000 2 000 1 000 000 000 000 Sr-i .11 _N-Ji___ ___ i___ 500 000 200 000 100 000 50 000 N, 20 000 10 000 5 000 3 000 2 000 1000 -0 -30 -20 -10 10 20 30 *0 50 60 70 80 1 : 1 --j ! . i 1 11 ji j ; * > \* V NS NS %LV 4. \ \ \ --2*k v S s \ \ \ VsIs _ 90 100 HO 120 i Pydraul Measured Viscosities/^ In Centistokes Pump manufacturers recommended[operating PYDRAUL 625 PYDRAUL 280 PYDRAUt`A-200 PYDRAUL F-9 ^PYDRAUL 150 PYDRAUL 60 11 --p - -- \ --3^ C <c OD __i1 x s ia >s X>| 1 \ s > Ns N -so -0 -30 -20 -10 o 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270280 290 30031032033031 TEMPERATURE, DEGREES FAHRENHEIT KINEMATIC VISCOSITY, CENTISTOKES V TOWOLDMON0035391 Pydraql Lubricatk Properties Pydraul fluids lubricate as well as premium petroleum oil. Because of this prernium/fubricity, Pydraul fluids give the same lopg pump life as premium petroleum oil. Equipment re sponds at its optimum capability. And Pydraul fluids are designed to be permanent--they never evaporate or wear out. Timken Load (Passing) Almen Weai Almen Load falex Load--Jaw Load--Lbs. --Torque--lb. inches Falex Wear (Under conlimious load (fi 100 lbs., loss in inches) 1st 10 minutes 2nd 10 minutes Shell Four-Ball Wear (167F. 1 hr., 630 rpm, mm scar) Steel on Ste io 4p% Stget on Bronze 10 kg. 40 kg. PYDRAUL PYDRAUL V F-9 60 KNta. 14 lbs. l?,S00V^i 7,400 psi 2.0 mg((\ V4,000 psi r / 43 lbs. lbs. 25,000 psi ^y)|^psi PYDRAUL 150 ,, X 40lbs. Jf(200 psi 3.9 mg( 4,000 psi 46 lbs. 23,000 psi PYDRAUL A-200 50 lbs. 16,300 psi 1.3 mg( 4,000 psi 44 lbs. 24,000 psi PYDRAUL 280 53 lbs. 19,800 psi 1.7 mg( 4,000 psi 47 lbs. 23,500 psi 4100 a y ^0.000428 0.000190 N2300 2000 73 X 64 0.000475 0.000380 0.000*28 0.00033>v 4200 90 0.000380 0.000380 4100 87 0.0004 9 0 0.000356 4100 89 O.OOOG18 0.00033? 0.28 0.27 0.36 o!h. 0.25 0.26 0.67 0.48 0.51 0.43 N. 0.52 0.62 \1.18 0.82 0.80 1.40 1.25 1.28 2.35 1.58 1.70 -0.0084 -0.0011 -10.0120 -0.0063 -0.0037 -0.1859 +0.0008 -0.0020 -0.1212 -0.0378 --0.1601 --0.1134 -0.0848 -0.0191 -0.0151 -0.0217 Mixing Compatibilty <DRAUL WITH OTHER HYDRAULIC FLUIDS F9 | 60 | 150 | A-ZOO] 280 ] 6 PYDRAUL WITH OTHER PYDRAUL FLUIDS F9 60 150 A-200 312*_. 280 >9 X NO YES YES fES YES ' 60 150 A-200 X_ YES^ NO yes' \s NO yes'* YjX YES - YES YES YES YES YES YES 312 YES YESS 'Vs YES - YES 280 " YES YE8' Xs YES YES vtsAs625 YES YESn YES YES WATER-GLYCOL apd WATER-OIL EMULSION Fluids- Pydraul hydraulic fluids arstiot compatible with theV fluids. Pydraul31? is one of a family ol new low-cost synthetic bW Pydraul Ine-te- sistant Urfids characterised by high performance and low cost TV other (Itids m this family have the same compatibility as Pydraul 31? with olher Vriiaulic fluids anjj<With other Pydraullluids. The new Pydiau'lluids include PydiatH'ID, Pydiaui Pydraul 230, Pydraul 312, Pydraul 540. X 0510199 TOWOLDMONOQ35392 a Converting to PYDRAULis Easy Regardless of the type hydraulic fluid being & used, converting a system to low-cost Pydraul fluids is easy. Virtually every type of equipment l* which uses fire-resistant hydraulic fluid has been converted to Pydraul fluids. Most equip ment manufacturers are experienced in Pydraul fluid conversions and should be consulted. If changing seals is necessary, equipment manu al I facturers can recommend what seals to change, rtlA'- and many carry a supply of correct seals, at (iuC\ Laboratory tests and operational experience l\ ) 8^ow Viton*, Teflon*, and silicone the preferred jdj* \J elastomers for compatible seals^>r- moderate V\ -{beloW-TM -srafo. ewvineHiflually acccptable.-Nylon-and -teflon To replace other fluids which are compatible with Pydraul and where compatible seals are in the system, it is only necessary to add Pydraul as make-up fluid. It is not necessary to drain or clean. When converting from petroleum oils, j non-compatible synthetic fluids, water-glycol ' fluids, or water-in-oil emulsions, the following steps are recommended. These conform to USA Standard R93.5--19GG. a^<*vmHk^'TmC'future ^l^wikmticcordTng ^age8-in^hw'bortctet. Please ask the Monsanto fluids specialist for recommendations and assistance, #444494-260& Change-Over Procedures * iWrm V* CHANGING FROM PETROLEUM OIL 1. Completely drain and clean the system. Small amounts of oil will not interfere with the per formance of Pydraul, but resistance to fire is reduced by the amount of oil left in the system. 2. Drain and blow out pipelines. Manually clean valves and reservoirs. (^Registered trademark ol E. I. Du Pont de Nemours & Co., Inc. C i>/_______________________________ 3. Open or remove and drain valves. Replace gaskets, packings, and seals with those com patible with Pydraul. It is particularly im portant to change dynamic seals. Static seals do not necessarily have to be changed if they are not leaking. Non-compatible static seals will have to be replaced when the part is disassembled for maintenance. 4. Remove pumps, accumulators, and cylinders, if necessary, for draining. Replace packings, seals, gaskets, and bladders with those com patible with Pydraul. 5. Check component functions before the sys tem is closed and fluid is added. 6. If your system cannot be completely drained, you may have to flush it with a small amount of Pydraul. CHANGING FROM WATER-GLYCOL OR WATER-IN-OIL EMULSION 1. Drain and clean system thoroughly. Remove all traces of water. Empty all lines and low points or dead pockets in components. 2. Clean with steam or warm water. Follow by blowing with dry air. 3. Check sealing materials, hoses, and accumu lator bags. Replace if necessary with com patible materials. 4. Install a minimum charge of Pydraul and operate the system from 16 to 24 hours. During this period, inspect the reservoir. If water or other contaminants float to the top, skim them oil. 5. Drain the flushing charge immediately after shut-down while the fluid is warm. Drain all isolated points or parts which do not drain back to the reservoir. If. water is apparent in fluid clinging to walls, wipe down all acces sible parts. CHANGING FROM PHOSPHATE ESTERS (OTHER THAN PYDRAUL) 1. Drain the system completely. 2. Cleaning is unnecessary. 3. Generally, seal changes are unnecessary at the time of conversion, but installation of compatible seals is recommended during routine maintenance. I yx l II& 0510200 TOWOLDMONOQ35393 Sealsjand Packings___ Information PYDRAUL FLUID ^ ^ BUTYL A-200 F-9 s 150 R 625 S 280 S 60 R R--RecorpmCnded Materials compatible with Pydraul hydraulic fluid are necessaryTol* --dynamic-or moving seals. For static seals'lhey "are preTerredrbut not essential. The following table indicates materials recoinmended^.de pending on the Pydraul fluid selected. EPR M R" S S R VITON R R R R U S--Satisfactory SILICONE R R R R*\ S BUNA N u u u u u u... NEOPRENE u u u u u u NATURAL RUBBER u u u u u u M--Marginal Unsatisfactory'" \'TTUh1is list of component nmnpfacturers is a guide to obtaihing seals compatible with Pydraul fluids. Please contact yobt equipment manufacturerqV seal supplier for their most current recommendations/'- Acushnet Process Company 776 Belleville Avenue New Bedford, Massachusetts 02745 Anchor Packing Company 401 North Broad Street Philadelphia, Pennsylvania 19108 Bearings, Inc. 3634 Euclid Avenue Cleveland, Ohio 44115 A. W. Chesterton Company Everett Massachusetts. 02149 Chicago Rawhide Manufacturing Company 1311 Elston Avenue Chicago, Illinois 60622 C. E. Conover & Compan 333 Passaic Avenue Fairfield, New Jersey QX006 Crane Packing Company 6400 Dakton Street Morton Grove, Illinois 60053 Garlock Packing Company Palmyra New York 14522 Goshen Rubber Company, Inc. P. 0. Box 416 Goshen, Indiana 46526 Greene, Tweed & Company North Wales Pennsylvania 19454 Hercules Packing Corporation 11061 Walden Road Alden, NeW^ork 14004 International Pah^m#1 rporation' Bristol New Hampshire^ 3104 JohnsManYi^fe, 22 East 40th Street New York, New York 10016 CyW. Marsh Company 6 Hudson Street Muskegon, Michigan 49441 Minnesota Rubber Company 3630 Wooddale Avenue Minneapolis, Minnesota 55416 Parker Seal Company 10567 Jefferson Boulevard Culver City, California 90230 Plastic & Rubber Engineering, l/lc. 756 East Florence Avenue yr Los Angeles, CaliforniaJMJOOl Plastic & Rubber Products Company 2100 Hyde Park Boulevard Los Angeles, California 90047 Precision Rubber Products Corporation Hartmann Drive .eloanon, Tennessee 37087 Raybestos-Manhattan, Inc. Packing Division Passaic, New Jersey Reliable Rubber Products Eddyington Pennsylvania 19020 Rockwell Mechanical Packing Company, Inc. 1634 Long Beach Avenue Los Angeles, California 90021 W. S. Shamban Company \11617 West Jefferson Boulevard v^lver City, California 90230 Vellumbid Company Rockdale'Btreet and Beaman Avenue Worchester, Massachusetts 01606 The James Walker F Company, Inc. P. 0. Box 75 Chicago Heights, Illinois 65411 ( 8 0t> 104O1 TOWOLDMONOQ35394 ik. '^'Filters and Hoses FILLTT,ERS/Most standard oil filters are satisfactory. You can use aeliv<Nsirlh or clay types. Filter manufacturers include: Briggs Filtration Division Bowser Corporation Cookeville, Tennessee Dollinger Corporation 20 Centre Park Rochester 3, New York Pall Corporation 32 Sea Cliff Avenue Glen Cove, L. I., New York / Purolator Products 1000 New Brunswick Avenue Rahway, New Jersey Capital Engineering'Company 5839 Ashland Avenue\ Chicago, Illinois Fulflo Specialties Company, Inc. 410 Fancy Avenue Blanchester, Ohio Rosaen Filter Corporation 1776 E. Nine Mile Road Hazel Park, Michigan Commercial Filters Corporation (Honan-Crane) Lebanon, Indiana Cuno Engineering Corporation Sub. ot American Machine & Foundry 4627 S. Vine Street Meriden, Connecticut Hilliard Corporation 98 W. Fourth Street Elmira, New York Marvel Engineering Company 7227 North Hamlin Avenue Chicago 45, Illinois Schroeder Bros. Corporation 101 Nichof Avenue McKees Rocks, Pennsylvania / / Serfilco Division Service Filtration Corporation ^408 North Milwaukee / Niles, Illinois 60648 HOSES/Although both neoprene &nd buna elastomers swell some what in 1'ydraul, hose of these'materials have given satisfactory service when made of a reinfor<4d braid construction. Butyl, nylon or Viton are preferred when new hoses are installed. Suppliers include: / Lewis Products Hohenwald, Tennessee 38462 Samuel Moore Co. Mantua, Ohio Anaconda Metal Hose Divisipn Anaconda American Brass Co. Waterbury, Connecticut 08/20 Anchor Coupling Company 3600 N. Fourth Streep Ubertyville, Illinois/ Eastman Mfg. Coifipany (See Imperial-Etfstman Corp.) Department T/ 6300 West Howard Street Chicago 48y4llinois Electric Hose & Rubber Co. 1201 Duro Street Wilmington, Delaware Gates Rubber Company 999 South Broadway Denver, Colorado 80217 Imperial Eastman Corp. 6300 W. Howard Street Chicago, Illinois Resistoflex Corp. Roseland, New Jersey Stratoflex, Inc. 222 Roberts Cutoff Rd. Fort Worth, Texas Weatherhead Corp. 302 E. 131st Street Cleveland, Ohio 44108 OblQU^ TOWOLDMONOQ35395 Other Components PAINTS . . . resistant to Pydraul are supplied by: SWIVEL COUPLINGS Systems for Pjdraul fluids often contain swivel Couplings, Some suppliers are: Chiksan Division FMC Corporation 332 N. Brea Boulevard Brea, California Amercoat Corporation Department T Brea, California Andrew Brown Paint Company 5413 S. District Boulevard Los Angeles, California Carboline Company 32-R Hanley Industrial Court St. Louis, Missouri PIPE JOINT SEALERS . . . can be bought from: American Sealants Company (See Loctite Corporation) 115 N. Mountain Road Hartlord 11, Connecticut Crane Packing Company 6410 Oakton Street Morton Grove, Illinois Dow Corning Corporation Midland, Michigan Friesland Plastics Company Friesland, Wisconsin General Electric Company Insulating Materials Department 1 Campbell Road Schenectady 6, New York Permatex Company Department T. R. Flagler Court Building West Palm Beach, Florida Carrol Products 148 Marine Street Farmingdale, New York Vinch Paint & Chemical Company Torrence, California W. P^Vuller & Company 1645 W. Valencia Drive Fullerton, Cahfornia The Glidden Company 900 Union Commerce Buijding Cleveland, Ohio \ J Interchemical Corporation Finishes Division / 1255-T Broad Street Clifton, New Jersey / Lowe Brothers Company Third & Madison Streets Dayton, C^\o W. S. Shamban & Company 11617 W. Jefferson Boulevard Culver City, California Shell Chemical Company 110W. 51st Street New York, New York Magna Coatings & Chemical Corporation 1785 N. Eastern Avenue Los Angeles, California Nycote Laboratories 15002 Delano Street Van Nuys, California Pittsburgh Plate Glass Company One Gateway Center Pittsburgh 22, .Pennsylvania Rinshed-Mason Company 5935 Milford Detroit/Michigan Royalty Paint & Varnish Company B6sadena, California Saran Protective Coatings Company 2415 Burdette at Reed Ferndale, Michigan Sherwin-Williams Company 101 Prospect Avenue, N. W. Cleveland, Ohio Titanine, Inc. Seagrave Corporation Elmwood & Morris Avenues Union, New Jersey U. S. Paint, Lacquer & Chemical Company 2101 Singleton St. Louis, Missouri ACCUMULATORS . .. many hydraulicy/ystems for Pydraul contain ai/accumulator which uses a bladfler to separate the fluid from/iir or nitrogen pressure. For/these, a rubber compatible with the fluid is nec essary. Suppliers include: Greer Hydraulics, Inc. 5930 W. Jefferson Boulevard Los Angeles, California Ob 10*0i 10 TOWOLDMONOQ35396 eclaiming PYDRAUL Fluids Pydraul hydraulic fluid lost from leaks and spills can beWlaimed because it is exceptionally stable and resistant to water and other con taminates. If fluid losses are appreciable--fluid recovery can result in considerable savings. Simply placing a container beneath leaks until they can be repairedVill save some fluid. Where drip pans have boen\ised beneath hydraulic / machinery, more than half of the total Pydraul- leakage has been reclaimed. " This dollar-saving recovery appears especially advantageous because it isn't practical to re claim either water glycol or water-oil emulsions except to filter out large dirt particles. Re claiming Pydraul fluid helps make it the most economical fire-resistant fluid available. Reclaiming Pydraul consists of two steps: re moving water, and filtering dirt or other solid particles. / WATER REMOVAL... Water, does not mix with Pydraul and will, therefore,\form a layer on top. A drum reserved for contaminated fluid with a side and end bung, placed horizontally on a cradle about two feet off the floor, is a simple and effective settling chamber. Salvaged fluid can be added through a large funnel in the top opening and Pydraul periodically drained off through the lower opening. FLUID PURIFICATION SYSTEM For a more elaborate system, permanently stalled settling tanks, or a commercial installa tion can be used. / A second method is centrifuging. Suitable units are made by DeLaval and Sharples/Co. Cen trifuges operate swiftly . . . will separate water from large volumes of fluid in a short time. FINAL FILTRATION ... A number of filtration units are available complete1' with filter pump CENTRIFUGE SYSTEM FOR PURIFICATION anti motor. Other systems use filter media such as cotton linters, felt or metal screens. Attapulgus clay and Fuller's earth may be used to help keep the fluid clean, reduce moisture and lower neutralization number. Diatomaeeous earth filtraticjn is recommended for solid parti cles removal only. Paper and fiber type filters are recommended for water and particle re moval but are ineffective for lowering neutra lization number (acidity) values. Filters in the 3 to 5 micron range are recommended for Pydrainfiltration and rec lamation.'Such filter media will not affect the basic Py draul formulation. 11 05X020*. TOWOLDMONOQ35397 Handling Animal toxicity studies and human experience indicate that the Pydraul hydraulic fluids may^ be used safely if a few reasonable precautions are taken. Repeated or prolonged skin contact should be avoided not only to prevent absorp tion of the material and possible systemic effect but, also, because the fluids are excellent sol/ vents for the oils normally present in the skin. Thus, drying and irritation could occur. / When splashed or sprayed into the eyes, Pydraul causes painful smarting. There is no eyidenc.e, however, oT any permanent eye injury. In the event of accidental contact with the eyes, the eyes should be flushed with copious amounts of water for 15 minutes and the/Workman re ferred to a physician; physicians have used 1% Pontocaine solution and ophthalmic cortisone acetate solution to relieve imitation. When Pydraul is kept at .room temperature, it does not constitute a vapor inhalation hazard except in a confined, 4unventilated space. Res piratory protection or mechanical exhaust ven tilation should be provided if there is repeated and prolonged contact of the fluid with heated surfaces with resulting volatilization or possible decomposition-^ the fluid. Where a ruptured oil hydrauliofine near a white-hot surface means a Are, a ruptured hydraulic line containing Py draul causes a vapor with an unpleasant odor that eai/help you locate the trouble. OblOtOS TOWOLDMONOQ35398 DISTRICT SALES OFFICES ALL DIVISIONS AKRON, OHIO 44313 260 Springslde Drive VMontrose Development Park Tel. (216)666-4111 ATLANTA, GEORGIA 30326 Lenox Towers East 3400 Peachtree Rd. N. E,--Suite 1711 Tel. (404) 577-2260 BOSTON, MASSACHUSETTS 02149 Everett Station Tel. (617)387-5010 CHICAGO, ILLINOIS 3158 Des Plaines Ave. Des Plaines, Illinois 60018 Tel. (312)296-6688 CINCINNATI, OHIO 45206 1501 Madison Road Tel. (513) 751-6707 DETROIT, MICHIGAN 48235 500 Northland Towers East Tel. (313)357-0910 HONOLULU, HAWAII 96812 205 Pacific International Bldg. 677 Ala Moana Blvd., P.O. Box 3824 Tel. (808) 531-2744 HOUSTON, TEXAS 77002 1300 Main Street Tel. (713) 223-4011 LOS ANGELES, CALIFORNIA 90022 6670 E. Flotilla St. Tel. (213)723-2492 NEW YORK, NEW YORK 10017 277 Park Avenue Tel. (212)922-4111 ST. LOUIS, MISSOURI 63166 800 N. Lindbergh Blvd. Tel. (314)694-1000 SAN FRANCISCO BAY AREA 2710 Lafayette, Santa Clara, Calif. 95052 Tel. (408) 243-0414 SEATTLE, WASHINGTON 98104 911 Western Avenue Tel. (206) 622-4203 SPRINGFIELD, MASSACHUSETTS 01101 730 Worcester Ave. Tel. (413) 788-6911 WILMINGTON, DELAWARE 19803 2005 Concord Pike, Fairfax Tel. (302)658-6531 ultura^ivlsion all/ntownSpennsylvania < Professional Building 0 HamiltoX Street el. (215)437-1471 DE > MOINES, IOWA 50310 12 Merle Hay Tower el. (515)276-8r`" FF :MONT, NEBRASKA 68025 : >0 South Main Sveet >1. (402)727-12. ' INI IANAPOUS, INDkNA 46205' S lite 218, 4000 Maadows Driv:|. (317)547-914^ LU1 ING, LOUISIANA 0070 0, Box 174 . 1. (504)784-626^ MA JKATO, MINNESO' |A 560C 1 1 Madison East fl. (507) 387-3406 ME 4PHIS, TENNESSEl 3810-5 2 )3 Union Plaza Bid T si. (901) 278-7811 Ml SCATINE, IOWA 52/61 ' 0. Box 473 }|. (319)263-1331 EL fcORADO, ARKANSN,S 7173 Lion Oil Building I. (501) 863-3111 JAdKSON, MISSISSIPPI 39209 0. Box 10937, Wl stland St 1. (601) 352-364EJ N. llTTLE ROCK, AR| 4|0 West 8th Stret. (501)376-24: MEfdPHIS, TENNESSEE 38113 11)23 Riverside Drive, P. 0. E ifjl. (901) 948-44^1 Organic Division (Rubber Instruments) AKRON, OHIO 44111 0 Brown Strelt, P. 0. Box . (216) 434-J962 ILWORTH.flEW JERSEY 0 rth Sevenlfi St. & Monroe (201) 27fc-2900 Te*lle$ Divispn ATLANTA, GEl)l ' jlanta Merchandise 3 Peachtlee St., N . (404) 377-2260 rTE, NORTH C . Road, T1 (704) S64-0U0 GRE|ENVILLE. MoAlister Pfe; P.l>. Box 554, Statj 1(803) 2: NEW V)RK, NEty Y^bK 10001 350 Fifth Aver Tel. (2X> 556-5100 Monsanto "Nothing contained herein is to be construed as a recommendation to use any product in conflict with any patent MONSANTO MAKtS NO WARRANTIES AS TO THE FITNESS OR Ml RCH ANT ABILIT Y Of ANY PRODUCTS REFERRED TO. no guarantee of satisfactory results from reliance upon contained information oi recommendations, and disclaims all liability tor any resulting loss oi damage " Monsanto Company / P u.j /800 North Lindbergh Blvd. /St. Louis, Missouri 63166 TOWOLDMONOQ35399 0 5 1 0 *0 7