Interoffice Communication
To From Date Subject
Robert L. Lembke, M.D. Oran D. Steffey January 22, 1975
ABERDEEN CHEMICAL PLANT
During the week of January 12, 1975, Andy Longoria, M.T., and I visited the Aberdeen Chemical Plant for the purpose of taking biological samples and checking the Installation from the standpoint of OSHA Standards which cover General Environmental Control-Sanitation.
The following areas were covered from a general Industrial hygiene standpoint:
Main Offices Color Weigh Area Automatic Bagging Area Old Hose Line Area Line III Lines I and II Plasticizer Building Central Break Room Storeroom Dryer Building V-ll Switch Gear Room D 300-400 Reactor Area Compressor Building Treating Ponds Drum-Material Storage Lupersol Storage Prairie Storage
West Warehouse Manual Bagging Area Hog Area New Warehouse Dry Blend Control Room Laboratory Main Change Room Shop V-10 Reactor Building Vinyl Break Area V-ll Reactor Building Steam Generation Plant Dry Chemical Storage Blending Silos Empty Drum Storage Federal Compress Storage VCM Unloading
a
The following comments are made relative to the above areas:
Main Offices - This area was found to be in good shape. Discrepancies which were reported as a result of the June 23, 1974, inspection have been corrected.
Warehouse-West - The storeroom over the Purchasing and Accounting offices is in very poor condition. Floors were dirty and needed cleaning. Insula tion material, which appeared to be old asbestos type insulation, had been torn from lines and left laying on the floor. Precautions should be taken when removing asbestos type insulation and it should be placed in plastic bags, marked and disposed of immediately. Materials need to be sorted out and should be stored in an orderly manner. Containers of chemicals
*
VAB.0001050522
4
Robert L. Lembke, M.D. January 22, 1975 Page Two
were found stored in this area. All chemicals should be in an area used for normal safe storage of such materials. The platform area just out* side this storeroom should be cleaned up and materials should be stored in an orderly manner. Railings have been installed around this area.
In the warehouse proper, materials were found to be stacked unsafely. Some containers had been left stacked precariously, some boxed materials were crushed on the side. Contents of some containers were spilled onto floors and onto pallets. All spilled materials should be cleaned up, dust should be vacuumed from all stored materials and floors in general should be kept free of dust and trash. There is still the very unsanitary condition, which existed during the last inspection of this area, where people walk along the fence and spit tobacco onto the floors and onto the
. This practice creates a very unsightly and most unsanitary condition.
Color Weigh Area - The area next to the color weigh room used for storage of materials needs to be cleaned up. Floors are dusty, some bags are broken and materials have spilled onto the floor and other stored materials. Some of these materials contain lead. This entire storage area has been in need of better maintenance for some time, especially since materials which contain 'lead are stored here.
The weight room is dusty throughout. The hood exhaust system still appears not to be efficient in removing dust. Again the recommendation is made for cleaning of filters and maintenance of this equipment. If this equipment is not found to be efficient due to needed engineering changes, these changes should be made without delay.
Manual Bagging Area - This area has been improved, however, dust is still prevalent to the extent that better attention should be given to use of vacuum cleaning.
Automatic Bagging Area - Excessive noise is caused in this area from compressors. These units should be sound proofed or moved to an area which would eliminate the noise in the bagging areas. If moving is chosen for alleviating this problem, relocation should be in an area where other persons are not effected by the same problem. The floors need to be cleaned. Dust and various incidental materials have been left laying about the area.
Hog Area - This area in general is very discouraging. Much fine dust covers parts of equipment and floor in thick layers. Water lays about the equipment and especially around electrical switch gear boxes along the east wall. Poor lighting, which has been an item of past industrial hygiene inspections, has not been improved. With no more light than is' provided in this area and with the poor housekeeping condition now prevalent, this area is very unsafe and unhealthy.
VAB.0001050523
Robert L. Lembke, M.D. January 22, 1975 Page Three
4V
Old Hose Line Area - This entire area needs to be cleaned up. Materials should be stored in an orderly manner, space should be left between items to allow for cleaning and sweeping and trash and dust should be kept cleaned from the stored materials and from the area in general. Various odds and ends such as hose spools and other materials are stored in an unorganized manner. Floors are dusty and dirty.
New Warehouse - The floors around the shrink-wrap machine should be cleaned and swept. Trash and odd items need to be picked up and removed from this area. The drinking fountain near the south wall next to the office and loading dock doors needs to be replaced. This fountain appears to be plumbed directly to the sanitary waste line. A trap should be placed in the drain line between the fountain and the sanitary waste line.
Compound Line III - Materials on the floor around the equipment need to be picked up and. the floors should be swept and kept cleaned.
The room adjacent to and just south of Line III, needs to be cleaned up. Materials stored in the south east corner of this room should be stored in an orderly manner, dust should be vacuumed from items and broken bags of materials should be cleaned up.
In the Line III compound mixer area, the floors are dusty, materials need to be stored more orderly, dust should be vacuumed from floots and stored materials. It was observed that a compressed air hose was being used to remove dry blend mix from equipment. Blowing of materials by an air hose should be prohibited. Various materials were stacked around the door exit near the master batch blender. All exits should remain clear at all times. The master blender is very dusty. It is recommended that engineering attention be given to provide for a more efficient and less dusty operation.
Dry Blend Control Room - The drinking fountain drain line appears to be plumbed directly to the sanitary waste line. A trap should be Installed between the fountain and the sanitary line. It was observed that fresh air masks were notbeing kept clean. These were being taken into dirty areas for use and left hanging or laying around to collect dust and dirt in these areas.
Compound Lines I and II - These lines were not in operation at the time of this Inspection. Most of the area was in good condition, however, dust needed to be cleaned from the equipment and from the floors around the equipment.
Laboratory Area - The ladies restroom needed to be cleaned* Materials and various items were stored haphazardly on the floor and on a small shelf. All items should be kept stored neatly on this shelf and nothing should be left on the floor. The floor needed to be cleaned and especially around the toilet stool and at the junction of floor and wall. Tiles should
y
VAB.0001050524
Robert L. Lembke, M.D. January 22, 1975 Page Four
be cleaned and the lavatory needed to be cleaned. The drain from the drinking fountain in the main part of the laboratory appeared to be connected directly to the sanitary waste line. This drain should have a trap installed between the fountain and the waste line.
Storage shelving in the storage area in the southeast part of the labor atory should have protective lips Installed on those being used for bottles and glass containers of chdmlcals and samples. The aisle in this storage area was cluttered with boxes and dolly carts. Laboratory benches along the north wall of the development laboratory need to be cleared of stored materials. All benches should be kept clean and free from storage items.
Plasticizer Building - The ground level floors need to be swept and cleaned. Drums containing Formic Acid are corroded along sides and some have sides near the bottom ends crushed in. These should be tested for soundness and those not safe should have the contents transferred to a new drum.
On the second floor, P-Toluenesulfonic Acid, which is contained in drums, is being heated by steam strap heaters and the material is being transferred to the reactors by use of a bucket. A safer method and one less likely to cause exposure should be devised for handling this chemical. Floors need to be cleaned, especially around the reactors.
In the storage area, workers were at work re-bagging Isophthalic Acid without the use of dust masks or gloves. Floors in this area need to be cleaned and dust should be vacuumed from floors and stored materials. Blsphenol bagged materials need to be re-stacked and re-bagged since some stacks are tilted and some bags are split open. Trimetalllc Anhydride bags are broken and contents should be re-bagged. Powdered Activated Carbon bags are broken and materials need to be re-bagged. This storage area in general needs to be cleaned, materials re-bagged, and all items re-stacked in an orderly manner.
Change Room - For the most part this area was found to be in good shape.
Central Break Area - Lunch pails are being left on the tables and in window sills. All lunch pails should be stored on shelves which have been provided, thus making it easier for those doing janitorial work to clean and maintain the rooms. Used paper cups and refuse had been left on tables, this should be placed in receptacles provided. Trash and dirt has been allowed to accumulate under and behind vending machines. This same condition existed during the last inspection. These machines should be moved out from the walls at least once a month and the floors cleaned In order for sanitary conditions to exist. With the conditions as they are there was evidence of cockroaches and one does not need to look very far to see the reason for the presence of such disease bearing insects. These same vending machines were found to be dirty and needed cleaning. Some of these were out of order and appeared to not be of much use. If these
VAB.0001050525
Robert L. Lembke* M.D. January 22, 1975 Page Five
are to remain in this room* they should be serviced and maintained in workable condition or they should be removed so as not to contribute to catching of dust and trash and to prevent problems for those charged with cleaning the room. The microwave oven is still sitting on an Inverted metal trash can. This same condition has existed during past inspections. The inside of this oven is dirty and needs to be cleaned. A table should be provided without any more delay. A wood panel below one of the windows in the west wall has a hole in it and needs to be replaced with a new painted panel. The drinking fountain needs to be cleaned and should be checked to be sure it has a trap in the drain pipe. Floors in this lunch room need to be scrubbed* mopped and cleaned* especially around the edges at the floor-wall juncture and in the corners. The windows are dirty and need to be cleaned. Water was running and dripping from the roof over the east entrance and water was standing all along this area In the approach to the laboratory-warehouse area. The drainage should be improved to eliminate this standing water and the source of the dripping water should be eliminated.
Shops - This area has Improved in housekeeping but much is yet to be desired. Floors beneath and behind workbenches need to be cleaned and in general the entire area requires a constant effort to maintain cleanliness and for the storage of materials in an orderly fashion.
Storeroom - Personnel are trying hard to maintain good housekeeping in this area. Space is at a premium. Aisles are cluttered with materials and by necessity items must be stacked outside needed storage shelving. An electrical line leading from an outlet on the south wall into the office in the west side of the storeroom should be replaced with a permanent line. The panels on the main electrical duct work have been left open and electrical lines* some of which are bare and possibly live* have been left dangling in the open and unprotected from being touched. The roof above this office and where electrical switch gear boxes are Installed leaks. This condition should be corrected as soon as possible.
+
V-10 Reactor Building - This building is being cleaned and straightened. Even though this building is no longer a production area, it should be maintained in an orderly and clean condition. All drums and containers being stored in this building should be properly labeled as to correct contents.
Dryer Building - Fresh air masks are stored in a mask cabinet which is blocked by steel cabinets. Masks have also been stored dirty and dusty. A new drinking fountain appears to be plumbed directly to the sanitary waste pipe. A trap should be Installed in the drain pipe between the fountain and the sanitary line. The dryer building was found to be in good shape throughout its entirety.
Vinyl Break Area - The refrigerator needed to be cleaned* especially the freezing compartment. The inside of the microwave oven needs to be cleaned. The drinking fountain should be checked for installation of a trap in the
VAB.0001050526
f
Robert L. Lembke, M.D. January 22, 1975 Page Six
drain pipe between the fountain and the sanitary waste line* The rest room was much improved, however, the floors should be cleaned and scrubbed In the corners and at the juncture of floor and wall. Wall tiles need to be scrubbed and cleaned.
h
V-ll Switch Gear Room - Some of the control boxes were open. These should be kept closed. One control was tagged to indicate work being done on a unit controlled by this box. A lock out should be used under these conditions to assure that the system is not actuated.
V-ll Reactor Building - This building is not being used. It was found to be clean and In good condition.
D 300-400 Reactor Area - The small refrigerator needs to be defrosted and cleaned. The drawers in the metal cabinet behind the consol and which is being used in conjunction with food preparation and lunches need to be cleaned. These drawers are cluttered with trash, they are dirty and should be maintained in a clean, sanitary condition. The control room in general was found to be in good shape.
Steam Generation Plant - This area has been improved, however, much needs to be done in the way of sorting and storing of materials. Items stored in shelving and on benches should be cleaned up and stored in an orderly manner. Preformed insulation materials are stored on the metal walk way along the east wall of the building. Some of this has been broken. This should be cleaned up and a check should be made to assure that there is no asbestos type of insulation stored here. Materials above the office and storage should be sorted and stored orderly. Shelving being used, in the office or test room, for storage of chemicals should have protective lips installed. The drinking fountain appears to be connected directly to the sanitary waste line. This should have a trap installed in the drain line between the fountain and the sanitary line. There is some question as to whether untested well water used for boiler feed is being used through this drinking fountain. The water being supplied to this fountain should be city water only.
Compressor Building - Water was covering part of the floor in the west part i of this building. Drain channels should be cut into the floor leading to the floor drains in order to alleviate this condition. Covers to electrical ducts located in the northwest part of this building were open and electrical wires were exposed and draping out. These wires should be tucked inside the ducts and the covers should be closed and secured.
The cooling water reservoir beneath the floor of this building does not appear to have sufficient overflow relief which could result in flooding of the entire building floor surface. If this happens a very dangerous condition would exist since banks of switch gear boxes are Installed along the south side of the room in a recessed portion of the floor.
VAB.0001050527
1
Robert L. Lembke, M.D. January 22, 1975 Page Seven
A sufficient overflow relief should be provided In order to prevent such condition. Trash should be cleaned from behind the most southwest located bank of switch gear boxes.
Dry Chemical Storage - The enclosed part of this area should be cleaned, floors should be swept and all materials should be stored In an orderly manner.
Treating Ponds - Sulfuric Acid Is used In this area to adjust the pH of the water in the ponds. This requires the presence of a safety shower which has been installed but it has been located in a very poor location. It Is somewhat hidden behind buildings and associated equipment, it is not well marked. It is some distance from where the acid Is being added to the ponds and it was not In working order due to being frozen on the day it was Inspected. This shower should be relocated to an area which would make it more accessible, It should be marked and painted a bright contrasting color, and it should be kept in usable condition in any kind of weather. The acid drums should be kept stored together in an orderly manner. These were scattered over the general area and not stacked together very neatly.
Blending Silos - These silos continue to be a very dusty area. Resin was found to be laying about the area In very thick layers. This material should be kept cleaned up and the general area should be kept clear of all products.
The area along the east side of the building and just to the north of these silos was stacked with all sorts of trash and various materials. This should be cleaned up and the entire area along the building should be kept clear of materials. This area has been one which has Indicated a problem during every Inspection which has been made.
er
Drum-Material Storage - The fenced storage area located at the southeast comer of the hew warehouse needs to be cleaned up. Drums should be stacked with more care. Some of these are stored so that they overhang pallets and present a d.angerous unbalanced condition. Room needs to be left between rows of stacked drums so that access can safely be gained and so that housekeeping can be done.
It was noticed that a fire extinguisher located at the southwest corner of the fence of this area was completly blocked by material which had been left stored around it.
Empty Drum Storage - This area located just south of the plasticizer building is greatly improved. Drums are near the southeast corner of this building. Pallets have been left laying around in disarray. These should be stacked in an orderly manner and out of the way in order to give safe passage through the area. Various products are allowed to run from the supposedly empty drums stored here.
4
+
f
VAB.0001050528 ?
Robert L. Lembke, M.D. January 22, 1975 Page Eight
This causes a very undesirable condition not only on the cement pad along the building but along the entire graveled area along the south of this cement pad* Some method should be devised to safely drain pro ducts left in the drums and maintain a clean sanitary condition in this area. This condition has been reported before.
Lupersol Storage - A new storage area has been constructed for lupersol. This was found to be in good condition.
Federal Compress Storage - For the most part this area was found to be in good shape. Bags of PVC resin should be stacked with greater care. Some of these were stacked with questionable stableness. A small mobile trailer which affords a clean lunch area and which has restroom facilities has been provided for those working in the area.
a
Prairie Storage - Warehouses being used for storage were found to be in good shape in most respects. The restroom would still be considered make-shift. It was not clean. An electric heater was being used to reduce the chill in the toilet area and this required plugging in the heater to a wall outlet outside the toilet and draping the electric cord across the entrance way. The fability consists of walls constructed around a stool and lavatory with no roof or ceiling provided. Lighting is still quite inadequate throughout these warehouses.
VCM Rail Unloading - This area was found to be in good shape. A periodic inspection needs to be made to assure that all grounding lines are in
4
good shape throughout their full lengths.
In addition to the above discrepancies found in the specific areas listed, the following comments are made relative to other areas:
The area just south of the shops and west of the Central Break Room needs to be cleaned up. All materials which are placed in this area should be stored in an orderly manner and the area should be maintained clean and neat.
Near the southwest outside corner of the shop and storeroom, sulfuric acid is being used at a treating pit. No safety shower was in evidence. A safety shower and eyewash fountain should be provided for this area. They should be located so that easy access will be assured, they should be painted a bright contrasting color and be marked with proper signs.
i
All drinking fountains throughout the plant should be checked for installation of drain line traps between the fountain and sanitary waste lines. These should also be checked to assure that city water is provided at the fountain.
A clear answer did not appear available as to frequency of sampling of breathing air provided by the compressor unit near the west property line.
VAB.0001050529
r
Robert L. Lembke, M.D. January 22, 1975 Page Nine
Concern for this was shown during the last Inspection. The OSHA regulations concerning breathing air was pointed out In specific terms in the last Industrial hygiene trip report. A program for sampling this air should be instituted which would give unquestionable information as to the quality as specified for breathing air.
Indications were quite obvious that much improvement is being made at this plant. A greater effort is being made to clean up most areas. Much is to be done but with a progressive effort to attain a clean, safe plant and with the institution of a program which would maintain good, clean hygienic conditions once these are attained will give desired qualities to working conditions in the plant. Management is to be commended for this effort shown.
4
i Industrial Hygienist
rla
VAB.0001050530
4
Robert L. Letnbke, M.D Oran D. Steffey January 22, 1975 TRIP TO ABERDEEN CHEMICAL PLANT
During the week of January 12, 1975, Andy Longoria, M.T, and I visited the Aberdeen Chemical Plant for the purpose of taking biological samples and checking the installation from the standpoint of OSHA Standards which cover General Environmental Control-Sanitation.
The following areas were covered from a general industrial hygiene standpoint:
Main Offleas Color Weigh Area AntoWitic Bagging Area Old Hbse Line Area Line III Lines I and II Plasticiser Building Csntrsl Break Room S torercom Dryer Building V-ll Switch Gear Room D 300*400 Rssetor Arss Compressor Building
Treating Ponds Drum-Material Storage
Storage Storage
West Warehouse Manual Bagging Arss Hog Area New Warehouse Dry Blend Control Room Laboratory Main Change Room Shop V-10 Reactor Building Vinyl Break Araa V-ll Reactor Building Steam Genaratlon Plant Dry Chemical Storage Blending Silos Empty Drum Storage Federal Compress Storaga VCM Unloading
The following comments are made relative to the above areas:
Msln Offleas - This aras was found to bs in good shape. Discrepancies whichevere reported as a result of the June 23, 1974, inspection have been corrected.
Warehouse-West - The storeroom over the Purchasing and Accounting officea is in very poor condition. Ploors were dirty and naeded cleaning. Insula tlon material, which appeared to be old asbestos type insulation, had bean torn from llnei and left laying on the floor. Precautions should bs taksn when removing asbestos type insulation and it should be placed in plastic bags, marked and disposed of immediately. Meterisle need to be sorted out should be stored in an orderly manner. Containers of chemicals
VAB.0001050531
i
Hobart L. Ltabb* M.D January 22, 1975 Page Two
4
vara found stored in this area. All chemicals should be In an area used for normal safa storage of such materials* The platform area Just out side this storeroom should be cleaned up and materials should be stored in an orderly manner* Railings hare been Installed around this area*
In the warehouse proper, materials were found to be stacked unsafely. Some containers h# been left stacked precariously, some boxed materials were crushed on thp side. Contents of some containers were spilled onto floors and onto pfIleta. All spilled materials should be cleaned up, dus should be vacuumed from all stored materials and floors In general should be kept free of dust and trash. There la still the very unsanitary condition, which existed during the last Inspection of this area, whers people walk along ithe fence and spit tobacco onto the floors and onto the fence* This practice creates s vary unsightly and most unsanitary condition.
Color Weigh Arcs - The aree next to the color weigh room used for storage of materials nsedf to be cleaned up. Floors are dusty, soma bags srs broken and materials have spilled onto the floor and other stored materials. Some of these materials contain lead* This entire storage ares has been in need of bettermaintenance for some time, especially sines materials which contain lead are stored here*
The weight room is dusty throughout* The hood exhaust system still sppssrs not to be Efficient in removing dust* Again tha recommendation is made for cleaning of filters and maintenance of this equipment. If this equipment is mot found to be efficient due to needed engineering changes, thase changes should be made without delay*
Manual Banging Arms - This area has been improved, however, dust is still prevalent to the! extent that batter attention should be given to use of
vacuum cleaning*
Automatic Bagging -Area - Exeaaalva noise la caused in this area from compressors* These units should be sound proofed or moved to an area which would allxjjiste tha noise in the begging areas. If moving is
chosen for alleviating this problem, relocation should be in an area whera other persons are not effected by the seme problem. The floors need to be cleans!)* Rust and various incidental materials hove been
left laying about the area.
Hog Area - This afoa In general la vary discouraging* Much fine dust
covers parts of equipment and floor in thick laysrs* Water leys about
tha equipment and,especially around electrical switch gear boxes along
the east wall*
lighting, which has been an Item of past industrial
hygiene inspections, has not been improved* With no more light than Is
provided in this gras and with tha poor housekeeping condition now
prevalent, this area Is very unsafe and unhealthy.
VAB.0001050532
4CT .
Robert L. Lambke, M.D. January 22, 1975 Page Three
014 Hose Line Ar*
This entire area
Materials
should be stored
an orderly manner, space should be left between items
to allow for cleaning and sweeping and trash and dust should be kept
cleaned from the stored materials and from the area in general. Various
odds and ends such as hose spools and other materials are stored In sn
unorganised maimer*
and
New Warehouse - The floors around the shrink-wrap machine should be cleaned and swept. Trash luid odd items need to be picked up and removed from this area. The drinking fountain near the south wall neat to the office and loading dock doorajneeds to be replaced. This fountain appears to be plumbed directly lip the sanitary waste line. A trap should be placed in the drain line between the fountain and the sanitary waste line.
Compound Line III Materials on the floor around the equipment need to be picked up and the floor* should be swept and kapt cleaned.
The room adjacentJfco and just south of Lina til, needs to be cleaned up.
Materials stored %t the south sast corner of this room should ba stored
in an orderly manner, dust should be vacuumed from items end broken bags of materials should be cleaned up.
In the line XII compound mixer area, the floors are dusty, materials need to be stored more fbrderly, dust should bs vacuumed from floors and stored materials. It wa(ij observed that e compressed air boss was being used to
remove dry blend wjfLx from equipment. Blowing of meterisle by an air hose
should he prohlbilbd. Various material* were stacked around the door exit near the master Mpch blender. All exits should ramain clear at all times. The master blender is very dusty. It is recommended that engineering attention be given to provide for a more efficient end less dusty operation
Dry Blend Control Room - The drinking fountain drain line appears to be plumbed directly Sp the sanitary waste line. A trap should be installed between the fountjjiln end the sanitary line. It was observed that fresh
sir masks were ncwelng kept elaan. These were being taken into dirty ereee for use and''lieft hanging or laying around to collect dust and dirt
in these areas.
Compound Lines I ijind II - These lines were not In operation at the time of this Inspection. Twbst of the area was In good condition, however, dust needed to be clearned from the equipment and from the floors around the equipment
Laboratory Area - The ladles restroom needed to be cleaned. Materials and various items were stored haphassrdly on the floor and on a small shelf. All items llsbould be kept stored neatly on this shelf end nothing should be left on the floor. The floor needed to be cleaned end especially around the toilet istool end at the junction of floor and wall. Tiles should
y.
4
VAB.0001050533
1
4
Robert L. Leabkefc M.D January 22, 1975 Rage Four
be cleaned and the lavatory needed to be cleaned* The drain from the drinking fountain In the main part of the laboratory appeared to be connected directly to the sanitary waste line* This drain should have a trap installed between the fountain and the waste line*
Storage shelving In the storage area in the southeast part of the labor atory should have protective lips Installed on those being used for bottles and glass containers of chemicals and samples. The aisle In this storage area was cluttered Kith hexes and dolly carts. Laboratory benches along the north wall of the development laboratory need to be cleared of stored materials. All benches should be kept clean and free from storage Items
Plasticizer Building - The ground level floors need to be swept and cleanad Drums containing Formic Acid ars corroded along sides and soma have sides near the bottom etuis crushed in. These should be tested for soundness and those not safis should have the contents transferred to s new drum.
On the second floor, P-Toluenesulfonic Acid, which is contained In drums, is being heated by steam strap heaters and the material Is being transferred to the reactors by use of a bucket. A safer method and one less likely to cause exposure should be devised for handling this chemical. Floors need to be cleaned, especially around the reactors.
In the storage area, workers were et work re-bagging Isophthallc Acid
without tha use of dust masks or gloves. Floors in this ares need to be
cleaned end dust should be vacuumed from floors and stored meterlals.
Blsphenol bagged materials need to be re-stacked and re-bagged since some
stacks ere tilted and some bags are split open. Trlmetalllc Anhydride begs
are broken and contents should be re-begged. Powdered Activated Carbon
bags are broken and materials need to be re-bagged. This storage area In
general needs to be cleaned, materials re-bagged, and all items re-stacked
in an orderly manner*
t
Change Room - For the most pert this area wee found to be in good shape*
Central Break Ml
window sills.
- Lunch pails are being left on the tables and in palls should bs stored on shelves which have bean
provldsd, thus making it easier for these doing janitorial work to clean
and maintain the rooms. Used paper cups and refuse had been left on tables,
this should be nlnfjfd in receptacles provided. Trash and dirt has been
allowed to
e under and behind vending machines. This same
condition existed
the last inspection. These machines should bs
moved out from
at least once s month end the floors cleanad in
order for sanitary conditions to exist. With the conditions as they ere
there was evidence
cockroaches and one does not need to look very far to
sea the reason for the presence of such disease bearing Insects. These
asms vending mechli^a were found to be dirty end needed cleaning. Some
of these were out of order and appeared to not be of much use. If these
VAB.0001050534
j ji \
1
Robert L. Lembke, M.D. January 22, 1975 Pag# Viva
r
ava to ranain in this room, they should ba serviced and maintained in workable condition or they should ba removed so as not to contribute to catching of dust and trash and to prevent problems for those charged with cleaning the room. The microwave oven is still sitting on an Inverted metal trash can. This same condition has existed during past inspections. The Inside of this oven is dirty and needs to be cleaned. A table should bp provided without any more delay. A wood panel below one of the windows in the west wall has a hole in it and needs to ba replaced with a new painted panel. The drinking fountain needs to be cleaned and should be checked to be sure It has a trap In the drain pipe. Floors In this lunch room need to be scrubbed, mopped and cleaned, especially around (the edges at the floor-wall juncture and in the comers. The windows are dirty and need to be cleaned. Water was running and dripping from the roof over the east entrance end water was standing all along this area in the approach to the laboratory-warehouse area. The drainage should be improved to eliminate this standing water end the source of the dripping
water should be eliminated.
'i .f
Shops - This area has improved in housekeeping but much Is yet to be desired
Floors beneath and behind workbenches need to be cleaned and in general the f
entire area requires a constant effort to maintain cleanliness and for the
storaae of materials in an orderly fashion.
/
Storeroom - Personnel are trying hard to maintain good housekeeping in
' --II IHH'M IIIW--I
'*
- a -. _
._
this area. Space is at a premium. Aisles are cluttered with materials
and by necessity items must be stacked outside needed storage shelving.
An electrical line leading from an outlet on the south wall into the
office in the west side of the storeroom should be replaced with a
;
Lm.
u
t
H
l
/
permanent line. The panels on the main electrical duct work have been left open and electrical lines* some of which are bare and possibly live have been left llngllng in the open and unprotected from being touched.
r
/
/
/r
The roof above this office and whare electrical switch gear boxaa are
/
Installed leaks* This condition should ba corrected aa soon as possible
u
t,
.0 Reactor Building - This building is being cleaned and straightened. i
Even though thlp ^building is no longer a production area, it should be
i vL /
maintained in en orderly and clean condition. All drums and containers
being stored in this building should be properly labeled as to correct
contents.
t{:
Dryer
stored
v
r
i.
i%
blocked by steel cabinets. Masks have algo been stored dirty and dusty
A new drinking fountain appears to be plumbed directly to the sanitary
t
i
;V
>\
waste pipe. A trap should be installed in the drain pipe between the
fountain and
sanitary line. The dryer building was found
good shape throughout its entirety.
x-.
Y
\ S'
Vinyl Break Arfta - The refrigerator needed to be cleaned, especially the Y: -r.' freexlng compartment. !% inside of the microwave oven naada to be clashed %K- '-r.
hi V < y
The drinking fountain should be chapied for installation of a trap in the V
VAB.0001050535
i
Robert L. lasihlre, MD. January 22, 1975 Page Six
*
f
drain pipe between the fountain and tha sanitary waste line. The rest** room was such improved, however, tha floors should be cleaned and scrubbed in tha comers and iit tha juncture of floor and wall* Vail tiles need to be scrubbed and clesined.
V-ll Switch Gear Holla * Sons of the control boxes were open* These should be kept closed* Oaf control was tagged to indicate work being done on a unit controlled by Ibis box* A lock out should be used under these conditions to assure that the system is not actuated*
f-k
V-ll Reactor Building * This building is not being used* be clean and Id goodcondition
It was found to
D 300*400 Reactor Afljea - The small refrigerator needs to be defrosted and cleaned. The drawersin the metal cabinet behind the consol and which is being used in conjunction with food preparation and lunches need to be cleaned. These drapers are cluttered with trash, they ere dirty and should be maintained in a glean, sanitary condition* The control room in general was found to be in good shape*
Steam Generation
4MP
m
to be done in the
This area has been improved, however, much needs sorting and storing of materials* Items stored
in shelving and on fetiches should be cleaned up and stored in a
manner* Preformed Insulation materials are stored on the metal
along the east vall^pf the building. Some of this has been broken. This
should be cleaned up and a check should be made to assure that there le no
asbestos type of lajtulation stored here* Materials above the office and
storage should be sprted and stored orderly* Shelving being used, in the
office or test room! for storage of chemicals should have protective lips
Installed The dripking fountain appears to be connected directly to the
sanitary waste line* This should have a trap installed in the drain line
between the fountain and the sanitary line* There is some question as to Whether untested wij|i water used for boiler feed is being used through
this drinking fountain* The water being supplied to this fountain should
be pity water only*
Build! * Water was covering part of the floor in the west part of this building* brain channels should be cut into the floor leading to the floor drains In-order to alleviate this condition* Covers to electrical ducts locatsd in tbjji northwest part of this building wars opsn and elsctrlcal
wirea war# exposed and draping out These wires should bs tucked inside tha ducts and tha c#vers should bs closed and secured*
'}
| Tha cooling water reservoir beneath the floor of this building doss not appear to have sufficient overflow relief which could reeult In flooding of the entire buildjfng floor surface* If this happens a very dangerous condition would sxipt since banks of switch gear boxes srs installed along the south side of the room In s recessed portion of the floor.
i
VAB.0001050536
Robert L. Lerabke, M.D.
January 22, 1975
Ptge Seven
A rufflelent overflow relief should be provided In order to prevent such condition. Treah should be cleaned from behind the aoet soutbeest located bank of switch gear boxes.
" manner.
- The enclosed part of this area should be cleaned. -- pt and all naterlals should be stored In an orderly
Treating Ponds - Sulfuric Acid Is used In this area to adjust the pH of the water In the ponds. This requires the presence of a safety shower
which has been Installed but It has been located In a very poor location.
It Is somewhat hidden behind buildings and associated equipment. It is not well marked, it Is some distance from where the acid la being added to the ponds and It Isas not In working order due to being frosen on t$te day It was inspected. This shower should be relocated to an area which would make it more accessible. It should be marked and painted a bright contrasting color, gjlftd 1* should be kept In ueable condition In eny kind of weather. The acid drums should be kept stored together in an orderly manner. These ware scattered over the general araa and not stacked together vary neatly.
Blending Silos - These alios continue to be a vary dusty ares. Resin was found to be laying About the area in vary thick layers. This material should he kept cleaned up and the general area should be kept deer of ell products.
The area along the seat side of the building and just to the north of thaaa silos was stacked with all sorts of trash and various materials This should be cleaned up and the entire area dong the building should be kept deer of materials. This araa has been one which has Indicated a problem during aveigy inspection which has been made.
Drum-Material Storage - The fenced storage area located at the southeast corner of the new warehouse needs to be cleaned up. Druse should be stacked with more cage. Some of these are stored so that they overhang pdlets and present e dangerous unbalanced condition. Room needs to be left between rows of stacked drums so that access can safely be gained and so that housekeeping can be done.
It wee noticed that a firs extinguisher located at the southwest corner of the fence of this area was completly blocked by materld which had bean left stored around It.
Empty Drum Storage -This area located just south of the plasticiser building Is greatly improved. Drums ere still being stored hepheserdly near the southeast comer of this building. Pallets have been left laying around In disarray. These should be stacked in an orderly manner end out of the way in order to give safe passage through the area. Various products era allowed to run from the supposedly empty drums stored here.
4
VAB.0001050537
Robert L. Letnbke, M.D.
January 22, X975 Page Sight
K
\ Thla eauaaa a very undesirable condition not only on the cement pad
` Vv
along the building but along the entire graveled area along the south of this cement pad* Some method should be devised to safely drain pro~ v ducts left in the inns and maintain a clean sanitary condition in this
Tl s _
: >V area. This condition has been reported before.
Lupersol Storage - A nee storage area has been constructed for lupersol. This was found to be in good condition.
Federal Compress Storage - For the most part this area was found to be in good shape. Bags of PVC resin should be stacked with greater care. Some of these werc*istacked with questionable stableneas. A small mobile trailer which affofds a clean lunch area and which has restroom facilities has bean provided tor those working in the area.
Prairie Storage - Warehouses being used for storage were found to be in good shape In most respects. The restroom would still be considered make-shift. It wei not clean. An electric heater wae being used tp reduce the chill Ip the toilet area and this required plugging in the heater to a wall optlet outside the toilet end draping the electric cord across the entrant! way. The facility consists of walls construetad around a stool and:lavatory with no roof or calling provided. Lighting Is still quite inadequate throughout these warehouses.
VCM Rail Unloading - This area was found to ha in good shape. A periodic inspection needs to be made to assure that ell grounding lines ere in good shape throughput their full lengths.
In addition to the above discrepancies found in the specific areas listed, the following comments are made relative to other areas:
*
it
The area just south of the shops end west of the Central Break Room naada to ba cleaned up. ;A11 materials which are placed in this area should be stored in an orderly manner and the area should be maintained clean and neat.
Near the southwest *outside corner of the shop and storeroom, sulfuric acid is being used let a treating pit. MO safety shower was in evidence. A safety shower and eyewash fountain should ba provided for this area. They should ba located so that easy access will ba assured, they should ba painted a bright contrasting color and ba marked with proper signs.
All drinking fountains throughout the plant should be checked for installation of drain line traps between the fountain and sanitary waste lines. These should also be checked to assure that city water is provided at the fountain.
A clear answer did not appear available as to frequency of sampling of breathing air provided by the compressor unit near the west property line.
4
VAB.0001050538
* IT
4
Robert L. Lenbke, M.J* January 22, 1975 Page Nine
Concern for this vu shown during the last Inspection* The 08HA regulations concerning breathing air was pointed out in specific terns in the lest industrial hygiene trip report. A program for ssapling this air should be instituted which would give unquestionable information as to the quality as specified for breathing air*
Indications were quite obvious that nuch improvement is being made at this plant. A greater effort is being node to clean up meet areas* Much is to be done but with a progressive effort to attain a clean, safe plant and with the institution of a program which would maintain good, clean hygienic conditions once these are attained will give desired qualities to working conditions in the plant. Management is to be commended for this effort shown.
Oran D. Sreffey Industrial Hygienist