American Society of Heating and Ventilating Engineers Guide, 1931
Table 16. Coefficients of Transmission (U) of 4-in. Cut Stone Veneer on Concrete Walls
' Note.--These coefficients are expressed in B.t.u. per hour per square foot per 1 deg. fahr. DIFFERENCE IN TEMPERATURE BETWEEN THE AIR ON THE TWO SIDES AND ARE BASED ON AN OUTSIDE WIND EXPOSURE OF 15 MILES PER HOUR.
Thevaluesof U inthisTablearebased onthefblloWinq InternalConductivitiesorConductances wh ichare
expressednB.Lu. per Ur: per Sq.Ft. perl"F
Stone Concrete (Stone 1.2:4 mix)
10.06 perl" 8.30perl"
Cement Mortar Plasterboard . Plaster (Gypsum)
8.00 per |" 3.73 per^ 2.32 perl*
Wood Lath t Plaster
200 as applied
Corkboard Riqid Insulation(Boardform)
0.30 perl" 0.33 perl"
Cellular Gypsum (18) Flaked Gypsum, Dry (24*)
0.59 perl" 0.48 per 1'
Y=Thickness of Insulation where specified
L $ Interior Construction -z.
Y
4>0 <0 ''
a; S \ . a *
. & 'TjyCement
* Mortar ThicknessofConcrete --X <b" a* lO' 12" 16"
A B c DE
1 Plain Walls - No Interior Finish
0.459 0.413 0.377 0.345 0796
2 \ Plaster on Concrete
3
3*
4
Plaster
on
Metal
Lath
-
Purred
0.418 a 380 0.348 0.321 0.279 0.293 0.274 0257 0.242 0.217
4 \ Pi aster on Wood Lath -- Purred
0.279 0.261 0.246 0.232 0.209
5 ^ Plaster on 3-" Plaster board-Purred
0.280 0.262 0.247 0.233 0.209
a
6
^ Rasteron Wood Lath on 2* Furrmq Strips -- Cellular Gypsum Fill b
if 0.184
0.176
0.169 0.163 Q151
5 Plasteron WoodLath on 2" Furrinq 7 Strips -- Flaked GypsumFill
a >' 0164 0.158 0.152 0147 0.137
B z Plasteron Rtqid Insulation -- ^Boandform) Purred
9
IQ 4 Plasteron Corkboard set in^ Cement Mortar.
i i.
r z 0.208 0.198 0.188 QI80 0166 r 0.158 0.152 0.147 0.142 0.133
it 0.134 0.130 0126 0122 0U6
2" 0.H0 0.107 0.104 0.102 0097
aBased on 1 in., the actual thickness of 2 in. furring strips. bThe coefficient used for cellular gypsum, 0.59 is for 18 lb. weight--weights as low as 12 lb. may be used.
52
Chapter 3--Heat Losses by Transmission
Table 17. Coefficients of Transmission (U) of Concrete Walls with Stucco as Exterior Finish
,__these coefficients are expressed in B.t.u. per hour per square foot per 1 deg. fahr. ^ PENCE JN TEMpERATURE BETWEEN THE AIR ON THE TWO SIDES AND ARB BASED ON AN OUTSIDE WIND EXPOSURE OF 15 MILES PER HOUR-
Tbevaluesrf Uin this Table are basedon thefbllawinq
Internal Conductivities orConductances which are
expressed in B.t.u.perUr. per 5q. Ft per l"F
`stucco
aoo perl
Concrete (Stone 1 = 2:4mix)
8.30 per 1
Plasterboard
3.73 per-g
Plaster (Gypsum)
2.32 perl
Wood Lath 4 Raster Corkboard
2.00 as applied ^ 0.30 per l"
Riqid Insulation (Boardform)0.33 perl
Cellular Gypsum (18*)
0.54 perl"
Flaked Gypsum, Dry (24 )
0.48 perl
Y- Tbicknessof Insulahon where specified
1 Interior Construction
2
Y
2T ** *
ft * " d
3" ,
*o
3 b '*
| /& *
n
1" Stucco*--^7---- on Wire Mesh
Thickness of Concrete - X
Co 8* IO" 12" i>" 20"
A B C DE F
1 Plain Walls - No Interior Finish
0.544 0.481 0.431 0.391 0.329 0.284
2 i Plaster on Concrete
0.486 0.437 0.395 0.361 0308 0.268
3 if Plasteron -Metal Lath -- Purred
0.326 0.302 0.282 0.264 0.234 0.210
4 j Raster on Wood Lath-Furred
0.308 0.287 0.268 0.252 0125 0.203
5 \ Plasteron \ Plasterboard-Purred
0.310 0.288 0.270 0.253 0.226 Q204
6
-j Plasteron Wood Lath on 2." Furrinq Strips-Cellulor Gypsum Fill b
a
r 0.1% 0.188 0.179 0.172 0.159 0.148
i Plasteron WoodLathon 2 Furrinq
7 Strips - FlakedGypsum pill
a
if 0.173 0.167 0.161 0.154 0.144 0-135
8 "5 Raster on Riqid Insulation
(Board form) Furred
9
10 i Raster on Corkboard bet in-E II Cement Mortar
r
z
0.223
0112
0102
0.192 0.176
0-163
r 0-167 0.160 0.154 0.149 0.139 0.130
He D.I4I 0.136 a 132 0.127 0.120 0.114 2" 0.114 0.1 II 0.108 0.105 0.100 0096
"Based on
the actual thickness of 2 in. furring strips.
bThe coefficient used for cellular gypsum. 0.59 is for 18 lb. weight--weights as low as i2 lb. may be used.
53