Document OEVO5g2OLmGjZZgdXYjebVZJv
Air System Equipment
Anemostat Corporation of America
ANENOSTAT10 East 39th Street
Representatives in
New York 16, N. Y. DRAFTLESS
DIFFUSERS Principal Cities
THE ANEMOSTAT PRINCIPLE
The Anemostat Air Diffuser consists of a series of conical shaped members of specific design and assembled in definite relationship to each other. Due to these exclusive and patented features, the Anemostat Air Diffuser breaks the primary air stream into a multiplicity of planes traveling in all directions, and at the same time creates an equal number of counter currents of room air traveling toward the device. This causes a quantity of room air equal to as much as 35 per cent of the supply air to be drawn into the device and mixed with the supply air before it is discharged. This important effect, which distinguishes the Anemo stat Air Diffuser from all other air outlets, is known as Aspiration, and should not be confused with secondary air motion. The Anemostat Air Diffuser, mQreover, permits air expansion within the device, instantly reducing velocity.
The mixture of primary and room air discharged from the Anemostat Air Diffuser entrains addi tional room air, which, due to the turbulence of the discharged air, is readily drawn into and mixed with the discharged air. This will continue until the movement of the discharged air has ceased.
The Anemostat Air Diffuser, therefore, thor oughly diffuses and mixes the incoming air with the room air, closely equalizing temperature and humidity throughout the room, and promptly con verts the velocity energy of the incoming air into pressure energy which prevents drafts in the occu
pancy zone.
1216
Anemostat Corporation of America
Air System Equipment
ANEMOSTAT Draftless Aspirating AIR DIFFUSERS
B a s ic F unc
t io n Siz e s
1 A s p ir a -
| TIO N C ool in g
N eck V e
lo c it y
L im it s o c a t io nL
This table shows basic data only ... Consult complete cata log for full information.
type
Ho a2
Applications
o
z
Nsse
z ta
J<
aah
> PH
,
AC AR-l
:jU
Combination supply and exhaust
Supply Frequent air change with low air velocity in room
10 Up to to Yes Yes 60 30%
15 Up to to Yes Yes 05 30%
Yes Yes
On exposed
No
700 to 2500
duct or flush to
railing
On exposed
Yes
700 to 3000
duct or flush to
ceiling
B
Supply
10 Up to to Yes Yes 05 35%
Yes
On exposed
Yes
700 to 3000.
duct flush to
ceiling
c Supply
10 Up to to Yea Yes 05 35%
Yes
700 to Flush to No 2500 ceiling
only
C-l
Supply Adjustable
pattern
12.5 Up to to Yes
45 35%
Yes
Yes
On exposed
Yes
700 to 2500
duct or flush to
ceiling
CSL
_______ _g
Supply Combination
diffuser
and light
20 Up to to Yes Yes 95 35%
Yes
E sp^*|
E-l Supply
.10 Up to to Yes Yes 30 35%
Yes
No
700 to 1500
CombinatioQ with | light cove
Acoustic
No 800 to tile orj
ceiling
NL-1
Combination diffuser and light
15 Up to to Yes Yes 40 30%
Yes
On exposed
No
700 to 1500
duct or flush to
ceiling
HU U2, .
For use with unit heaters
25 to 82.5
Up to
25%
Yes
No
No
No
700 to Projection 2500 heaters
Use on duct work for
heating and ventilating
25 Up to to Yes
82.5 25%
Yes
Up to Yes 108 Dif
ferentiftl
No
700 to On exposed 2500 duct
W ISIS
Wall type supply
5 Up to to Yes Yes
40 35%
Yes
No
700 to Wall or 2500 ceiling
"NO AIR CONDITIONING SYSTEM IS BETTER THAN ITS AIR DISTRIBUTION" -
1217
^