Document OEL9p4GVonRQekqjv8JZjpaKX

PLAINTIFF'S EXHIBIT INTERNAL CORRESPONDENCE INDUSTRIAL HYGIENE PRELIMINARY REPORT P. O. BOX 471, TEXAS C < TV, TEXAS November 19, 195J. F. Erdmann Texas City Plant to: R. W. Narvaez A. P. Yalcinkaya Summary Pipe insulation removed from #2 Powerhouse November 12, 1984 at 10:28 a.m. by Mr. J. W. Ickes was analyzed to determine percent water by weight and qualitative presence of asbestos. Procedure Sample was analyzed by Don Morgan for Total Solids (Vinyl Resins Method), and R. W. Narvaez for asbestos by Asbestest Kit. Results 14.28% volatiles by weight Positive asbestos test (Iron present). Kirk E. Martin KEM:IR Asbes2PH TjClC 10763