Document OEE6nNV813E9ZJQxGnOGgZkzX

TOWOLDMONOQ21205 SAVINGS Cost of cable___ 945 'This figure Annual cost of could represent cable losses........ .110 Total Savings 1055' 50% of the initial Pyroclor-filled . transformer cost. SYSTEM 2- PYROCLOR Comparethe costsof transformers at the load centre Source of cost* oiu Dry-type Class 'C' PYROCLOR Transformer 1000 kVA Fire protection equipment Civil Work 58% 110% 32% 10% Nil 8% 82% Nil 4% 100% 118% 86% 'Estimated cost based on a percentage basis of 100 for total oil transformer installation. TOWOLDMONOQ21206 Operating Parameters LOSS LEVELS Pyroclor-filled transformer loss levels are the same as oil and lower than dry-type Class 'C' units. kW NOISE LEVELS are lower than oil or dry-type Class 'C' units. dB(A) O PER ATIN G PAR AM ETER S IMPULSE AND OVERLOAD levels are the same as oil therefore higher than dry-type Class 'C' units. (Built to B.S. 171) maintenance M AIN TEN AN C E ................ I V TOWOLDMONOQ21207 Fluid Characteristics a Pyroclor is an askarel Askarel is the generic term for a group of synthetic chlorinated aromatic hydrocarbons used as electrical insulating media. b Pyroclor as a coolant Similar cooling characteristics to top-quality transformer oils BUT it has higher thermal/chemical stability. Pyroclor as a dielectric fluid C A dielectric breakdown strengrh better than toD-quality transformer oil. BS148 Transient arcing d If there is transient arcing small amounts of hydrogen chloride gas will be evolved but this will be absorbed by the gas scavenger additive in Pyroclor. thereby preventing pressure build-up in the unit. What happens to Pyroclor in the unlikely event eof a serious fault and major arcing occurs ? Pyroclor, like oil, would form gases. OIL Hydrogen which is explosive over a wide temperature range. PYROCLOR Hydrogen Chloride Gas. Non-explosive. No fire risk. W Are any other gases formed ? * IVIO ^dependent studies prove |\ll I that phosgene and chlorine are NOT formed under arc conditions. (0 wi o0 H <0 0 0 w > o. h O *> 0 < co EE < 111 I CO OD 0 Ui 2 30 , U. CO ! Summary of Benefits OIL PYROCLOR Dry type Class 'C' Fire precautions Maintenance Fire risk Siting limitations Low loss levels Low noise levels YES YES YES YES YES YES MO MO IMO MO YES YES MO YES MO YES MO MO High impulse levels YES -5 t|PI YES MO .- SO M E USERS o f P yro clo r-fille d tra n sfo rm e rs some rn^rs ~ Pyrotlc?i^!Ir transfonrs^ Aircraft B 0A C Westland Ae-craft Corporation Ltd Armed Services Ministry of Defence Automotive Firestone Tvre Co Ltd. Ford Motor Company Ltd. General Motors Ltd. Goodyear Tyre Co Ltd Michebn Tyre Co Ltd. Chemical Manufacturing ICI Ltd Electricity and Gas Central Electricity Generating Board Midland Electricity Board North Thames Gas Board North Western Gas Board South of Scotland Electricity Board Electronics The Post Office Decca Radar Ltd Food Alfred Bird & Son Ltd. General Foods Ltd Glass Mining Pilkington Glass Ltd. National Coal Board Oil British Petroleum Steel Richard Thomas & Baldwins Ltd The Steel Company of Wales Ltd Industrial plants No siting limitations Fire safety Load centre No maintenance Unaffected by air contamination Low riower loss High impulse levels Multi-storey buildings Schools, Hospitals. Hotels Load eontn> Fire safe?'. No matntnnanre Low noise levels CASE HISTORIES TOWOLDMONOQ21209