Document OEE6nNV813E9ZJQxGnOGgZkzX
TOWOLDMONOQ21205
SAVINGS
Cost of cable___ 945 'This figure
Annual cost of
could represent
cable losses........ .110 Total Savings 1055'
50% of the initial Pyroclor-filled . transformer cost.
SYSTEM 2- PYROCLOR
Comparethe costsof transformers at the load centre
Source of cost*
oiu
Dry-type Class 'C'
PYROCLOR
Transformer 1000 kVA
Fire protection equipment
Civil Work
58% 110%
32% 10%
Nil 8%
82%
Nil
4%
100% 118%
86%
'Estimated cost based on a percentage basis of 100 for total oil transformer installation.
TOWOLDMONOQ21206
Operating Parameters
LOSS LEVELS Pyroclor-filled transformer loss
levels are the same as oil and lower than dry-type Class
'C' units. kW
NOISE LEVELS are lower than oil or dry-type Class
'C' units.
dB(A)
O PER ATIN G PAR AM ETER S
IMPULSE AND OVERLOAD levels are the same as oil therefore higher than dry-type Class 'C' units. (Built to B.S. 171)
maintenance
M AIN TEN AN C E
................ I
V TOWOLDMONOQ21207
Fluid Characteristics
a Pyroclor is an askarel Askarel is the generic term for a group of synthetic chlorinated aromatic hydrocarbons used as electrical insulating media.
b Pyroclor as a coolant Similar cooling characteristics to top-quality transformer oils BUT it has higher thermal/chemical stability.
Pyroclor as a dielectric fluid
C A dielectric breakdown strengrh better than toD-quality transformer oil. BS148
Transient arcing
d If there is transient arcing small amounts of hydrogen chloride gas will be evolved but this will be absorbed by the gas scavenger additive in Pyroclor. thereby preventing pressure build-up in the unit. What happens to Pyroclor in the unlikely event
eof a serious fault and major arcing occurs ? Pyroclor, like oil, would form gases.
OIL Hydrogen which is explosive over a wide temperature range.
PYROCLOR Hydrogen Chloride Gas. Non-explosive. No fire risk.
W Are any other gases formed ? * IVIO ^dependent studies prove
|\ll I that phosgene and chlorine are NOT formed under arc conditions.
(0 wi o0
H <0
0 0
w
> o.
h O
*> 0
< co
EE
< 111 I CO OD
0 Ui
2 30 ,
U. CO !
Summary of Benefits
OIL
PYROCLOR
Dry type Class 'C'
Fire precautions Maintenance Fire risk Siting limitations Low loss levels Low noise levels
YES YES YES YES YES YES
MO MO IMO MO YES YES
MO YES MO YES MO MO
High impulse levels YES
-5 t|PI
YES
MO .-
SO M E USERS o f P yro clo r-fille d tra n sfo rm e rs
some rn^rs ~ Pyrotlc?i^!Ir transfonrs^
Aircraft
B 0A C Westland Ae-craft Corporation Ltd
Armed Services Ministry of Defence
Automotive
Firestone Tvre Co Ltd. Ford Motor Company Ltd. General Motors Ltd. Goodyear Tyre Co Ltd Michebn Tyre Co Ltd.
Chemical Manufacturing ICI Ltd
Electricity and Gas
Central Electricity Generating Board Midland Electricity Board North Thames Gas Board North Western Gas Board South of Scotland Electricity Board
Electronics
The Post Office Decca Radar Ltd
Food
Alfred Bird & Son Ltd. General Foods Ltd
Glass Mining
Pilkington Glass Ltd. National Coal Board
Oil British Petroleum
Steel
Richard Thomas & Baldwins Ltd The Steel Company of Wales Ltd
Industrial plants
No siting limitations Fire safety Load centre No maintenance Unaffected by air contamination Low riower loss High impulse levels
Multi-storey buildings Schools, Hospitals. Hotels
Load eontn> Fire safe?'. No matntnnanre Low noise levels
CASE HISTORIES
TOWOLDMONOQ21209