Document OE9mjk9jXGdVkvvpOVMQBGEQX

ABD00316370 t t VINYL 1985 SAFETY PROGRAM I. Monthly Safety Meetings A. Have two meetings dedicated to writing and discussing Job Safety Analysis. B. Have one meeting discussing home safety and home emergency preparedness. C. Have the Safety Department give the required annual respirator training to provide shift-to-shift consistency. D. Prepare the monthly meetings so that there is more operator participation. E. Have a meeting to review the recently revised power failure procedure. II. On-Shift Meetings A. Develop the use of short on-shift meetings to discuss recent safety problems, operational problems and review new or existing procedures. B. These meetings would also be used to get operator feedback on developing operational problems. III. Training Needed A. Train the "A" operators to assist in permit procedures by learning to clear equipment and prepare for maintenance. B. Have a training session for the Shift Supervisors and Chief Operators on the VCM tank farm. This would cover the railcar unloading operation and environmental/safety systems at the tank farm. ABD00316371 VINYL SAFETY REVIEW 1) 1984 REVIEW INJURIES b) VCM EXPOSURE 2) l98D DEPARTMENT GOALS 2) YARD SUPPORT A ) 1985 SAFETY PROGRAM *) ABD00316372 VINYL INJURIES Lee Childers - 12/22/84 - OSHA - bruised/fractured heel and stramec knee- fell off ladder while trying to open valve. Mike Nathan - 7/9/84 - OSHA - cut finger on insulation band - nor wear <z-1oves Mi 1 tan Threadgi11 7/8/84 - FA got a bug in his eye. Sammie Stokes - B/2/84 - FA - Skinned his knee - Climbed up on the aio un dump bo:-; to open a. valve. DATE 84/01 NAME Reactor Operator Reactor Operator Lead Operator ABD00316373 VINYL VCM EXPOSURE EXPOSURE 1.2 ppm- respirator 1.4 ppm- respirator i.5ppm- no respirator Shift Supervisor 84/02 Chief Operator 84/03 Chief Operator Reactor Operator Reactor Operator 84/04 Reactor Operator 84/85 Reactor Operator Chief Operator Reactor Operator Reactor Operator Reactor Operator 2,4ppm- respirator 29.1 ppm- respirator 454 ppm- respirator 3.7 ppm- no respirator 3.5 ppm- no respirator 1.4 ppm- respirator 144-6 ppm- respirator 16 ppm- no respirator 1.8 ppm- respirator 6 ppm- no respirator 3.7 ppm- no respirator 84/06 Utility Yard Operator Chief Operator Lead Operator Reactor Operator 10.7 ppm- respirator 2.5 ppm- respirator 3.7 ppm- respirator 4.3 ppm- respirator 3.9 ppm- respirator SOURCE / ^ Changing VCM filters in old unit. Conducting a VCM leak check in old unit. Worked in control room when presouricat ion was not working. Checking VCM filter packs in both units. Helping change VCM filter pack. Helping control emergency VCM release at tanK farm. Routine duties. No specific cause identified. Routine duties. No specific cause identified. Checking for leaks m the old unit. Changing VCM filter packs. Disconnecting and unplugging lip seal line on D30G. Changing VCM filter pack. Routine duties. No specific cause found. Painted handrails at incinerator and helped label breakers in vil dryers. No cause found. Monitoring blend tank level during pond ^esin pump up. Helped mechanics work on Corkens at tank farm. Blocking in VCM pum = with blown seal. Pumping pond resin. Changing VCM filter packs. Page 1 DATE 84/08 84/09 34/10 34/11 34/12 NAME Lead Operator Yard Operator Chief Operator Reactor Operator Reactor Operator Reactor Operator Utility Yard Operator Lead Operator Yard Operator Yard Operator Reactor Operator Reactor Operator Reactor Opera tor Yard Operator Reactor Operator Yard Operator Reactor Operator ABD00316374 VINYL VCM EXPOSURE EXPOSURE 1.3 ppm- no respirator 1.7 ppm- respirator 1.2 ppm- respirator 10.1 ppm- no respirator 1.4 ppm- respirator 2.9 ppm- no respirator 1.1 ppm- no respirator 2.6 ppm- respirator 2.2 ppm- no respirator 1.3 ppm- respirator 1.3 ppm- respirator 23.5 ppm- respirator 2.6 ppm- respirator 16.1 ppm- respirator 4.6 ppm- respirator 1.9 ppm- respirator 2 ppm- respirator 1.7 ppm- respirator SOURCE / Spent entire shift in control room. No cause found. Hooking/unhooking VCM rail cars and working on Corker, compressors. Changind VCM filter pad-. Doing routine .job. No cause found. Sampling 745 reactor. Training another operator in old unit. No specific cause found. Training in old unit. No specific ca-.-.se found. Hooking/unhooking VCM raiIcars. Working in vicinity of a VCM filter pack being changed. Hooking/unhooking VCM rai1 car s. Kcg!c i ng/un hoo!; ng '/CM raiIcars. Changing VCM filter packs. Rinsing out Chem Wash rank Changing VCM filter pack. Hooking/unhooking VCM raiIcars. Washing out Chem Wash tank, Unloading VCM railcars. Looking for leaks in the new unit. Page 2