Document OE2jaJbMENa0XN7XGO94E9z6v
1031 Speny Road Stockton, California 95206 TeU20S) 982-1500 Tetoc359491 Telaoopler{209) 46S81B4
September 5, 1986
Mr. Gerald John Payne Casualty Department Alexander & Alexander of
New York, Inc. 1185 Avenue of "thfe Americas New York, NY 10036
Re: J-M A/C Pipe Corporation General Liability & Workers' Compensation Insurance
Dear Mr. Payne:
Your letter of August 19, 1986, addressed to Ms. Shawn M. Medvin, has been forwarded to me for my attention. As you are aware, the Federal 0SHA has recently lowered the asbestos exposure standard from 2.0 f/cc to 0.2 f/cc. However, our most recent asbestos survey (copy attached) has revealed that only nine out of thirty (i.e., 307.) airborne asbestos samples tested in Stockton plant were in excess of the new OSHA standard of 0.2 f/cc. The situation was even better at the Denison plant, only two out of thirty-one (i.e., 6.45%) airborne asbestos samples tested were in excess of 0.2 f/cc. In other words, the airborne asbestos concentrations of most samples tested were below the new OSHA permissible exposure limit of 0.2 f/cc averaged over an eight-hour time period. Even for those workers who have been exposed to airborne asbestos concentrations greater than 0.2 f/cc, are well-protected by respirators.
In fact, ESIS, Inc. has already conducted an asbestos survey for Stockton Plant in this past August and will do the same thing for Denison plant this month.' We will, again, examine the survey data when they become available in the near future.
It should be further noted that the airborne asbestos concentrations can be greatly reduced by maintaining an effective ventilation system and following established
FPC 00472
SC-JMM-3235
Mr. Gerald John Payne September 5, 1986 Page Two
proper work practices. In addition, workers' exposure can also be minimized by shortening the work shift (i:e.', the exposure duration) and wearing respirators.
In summary, the J-M . A/C pipe operation is still in good shape; most sampling stations are in compliance . with the new 05HA exposure standard, and all related workers are properly protected by respirators.
If you still have doubt, I suggest that a meeting be scheduled in the near future. All parties involved can then discuss this matter in greater detail:
Sineerplv vnnrc
'
Corporate Environmental Control
EEW-.cl
cc: Mr. Ron Moreland, CIGNA Mr. Homer Hsieh, J-M Ms.-r
FPC 00473
TABLE 1
RESULTS SUMMARY OF SEMI-ANNUAL ASBESTOS SURVEY
at . J-M Mfg. Inc., Denison, Texas
March 31, 1986 Galson Project #S6-350-00
Location Employee's Name
operations
Exposure* Sample Sampling Level
I.D. Duration Fibers/cc
l Jimmy Lang
13* Utility Oper. 5756
254
2
Ed Heironimus
13' PM Tender
5757
246
3
Tommy Martin
Gen. Worker
5778
279
4 Ray Terrell
13' PM Head Curer 5758
243
5 Cecil Bell
13' PM Curer
5774
239
6
Charlie Moore
13 1 Control Oper. 5771
250
7 Lewis Ives
13' EM Asst Serv
5766
270
8
Phillip French 13 * Service Opr
5773
218
9
Charles Wilson 13* PM stm Tank Opr 5759
263
10 Arlis Chambers Salvage Trk Driver 5763 259
11 Dale Kent
Willow Operator
12 Pete Turnbull . Boiler oprator
13 Bill Rogers
UPL Operator
14 Glen Weger
UPL Helper
15 James Walsh
UPL Inspector
5820 5775 5764 5768 5765
260 260 255 253 252
16 Roger Cam
Janitor
5761
306
17 Dock Dill
UPL Hydrotester Opr 5824
252
18 Raymond Hesse 131 Unit Leader
5809 . 248
.19 Jeck Bartley
18000# Trk Driver 5776
249
20 Thurman Stanley MOA Operator
5777
246
21 Wilbur Greene Tool Room Opr
5762
246
22 Don Dutton
Molder
5787
168
23 Elliott Brown Crew leader
5792
167
24
Fredie Wright
Utility Trk Driver 5803
216
25 Bill Williams Electrician
5793
125
26 Murel Abernathy Mechanic
5B02
120
27 Jerry Bruce
Platform Trk Driver 5782
248
28 Jack Hansard
Sm Fork Trk Driver 5788
244
29 James Bush
Sample Plan Insp. . 5815
240
30 Henry Coldiron In Process Insp.
5788
240
31 Lawrence Arnold Slash Saw Opr
5805
240
0.09 0.16 0.10 0.13 0.15
0.16 0.21 0.11 < 0.02 0.02
0.19 < 0.02
0.09 0.03 0.09
0.05 0.04 0.06 0.03 0.04
0.05 0.04 0.03 0.02 < 0.03
0.04 0.08 0.03 0.08 0.03
1.08
* the locations correspond to those marked on Figure 1.
* actual and estimated whole day time-weighted-average exposure level. 5
FPC 00476
TABLE la
RESULTS SUMMARY OF SEMI-ANNUAL ASBESTOS SURVEY (Exposures less than 0.10 fibers/cc)
J-M Mfg. Inc., Stockton, California April 4, 1986
Galeon Project SS6-350-01
Employee's Name Location* (J-M Number)
Operations
Exposure
Sampling Level+
Sample Duration (fibers
l.D. (min)
per cc)
30 Area Sample -
(Lunchroom--top of 5812
247
(D-14WE)
food machines)
27 Area Samole
(Main Office--top 5811
256
(D-14S)
of file cabinets)
23 Richard Gerhart QC Auditor
5814
256
(D-10S)
24 Area Sample
(Waste Dump)
5819
253
(D--11S)
22 Brenda Ganner Power Sweeper Opr 5801 298
(D-5S)
13 John Gaines
Power Truck Opr
5794
263
(D-7S)
10 Area Samole
(Coupling Tester)
5784
274
(D-27F)
26 Tom Corralez
Forklift Opr/
5806
232
(D-13S)
Shipping Checker
17 Elliott Rutledge #3 PM Floorman
5785
251
(D-BWE)
28 Jerald Thornhill Warehouseman
5807
237
(D-3S)
16 Wanda Billberry #3 PM #1 Floorman 5799 271
(D-BWE)
14 Betty Spearman Laundry Room Opr 5795 298
(D-12S)
3
Paul Placencia #2 UPL Inspector
5769
252
(D-ibf)
4 Joe Ramirez
#1 UPL Inspector
5770
255
(D--3 OF)
20 Derrel Bonds
#3 Willow Operator 5787
257
(D-5WE)
11 John Castillo Sm MOA Lathe Opr
5790
256
(D-6F)
< 0.02 < 0.02 < 0.02 < 0.02
0.02 0.02 0.03 0.03 0.04 0.04 0.06 0.06 0.06 0.07 0.07 jr0.08
* Numbers indicate workstations sampled on figure (1).
+ Actual and estimated 8-hour, time-weighted-avg. exposure level.
FPC 00474 7
TABLE lb
RESULTS SUMMARY OF SEMI-ANNUAL ASBESTOS SURVEY (Exposures greater than 0.10 fibers/cc)
J-M Mfg. Inc., Stockton, California April 4, 1986
Galson Project #S6-350-01
Employee's- Name Location* (J-M Number)
Operations
Exposure
Sampling Level-*-
Sample Duration (fibers
I.D.
(min)
per cc)
15 Jay Brigdon '
Madrell Truck Opr 5796
256
(D-6S)
21 M. Macadangdang Lg Coupling Cut-off 5800 162
(D-8F)
Saw
9 Ed Cortez
#4 UCL Operator
5783
266
(D--5F)
19 Bob Lozier
#3 PM Operator
5789
253
(D-TWE)
2
Ruben Jauregui #2 UPL Inspector
5767
255
(D-19F)
12 Cerilo Acoba
#2 UCL Operator
5791
261
(D-3F)
5 Glen Tunn
#1 UPL Lathe Opr ` 5772
253
(D-31F)
8
Norma Christian Sm Wet Saw Operator 5781
266
(D-28F)
1 Lauri Miller Toolmaker
5755
252
(D-95)
7 Ben Cavan
Lg Wet Saw Operator 5780
298
(D-17F)
18 Rick Brown
#3 PM Crewleader. 5786
249
(D-6WE)
6 Mohamed Din
#1 UPL Unit Loader 5779
262
(D-32F)
25 Fran Kastlehaun Coupling Operator 5825 240
(D-33F)
31 Area Sample
#3 PM Flowthrough 5816
265
(D-17WE)
0.10 0.13 0.14 0.16 0.17
0.24 0.24 0.25 0.27 0.28 0.29 0.46
1.00 1.43
Numbers indicate workstations sampled on figure (1). + Actual and estimated 8-hour, time-weighted-avg. exposure level.
.