Document OE2jaJbMENa0XN7XGO94E9z6v

1031 Speny Road Stockton, California 95206 TeU20S) 982-1500 Tetoc359491 Telaoopler{209) 46S81B4 September 5, 1986 Mr. Gerald John Payne Casualty Department Alexander & Alexander of New York, Inc. 1185 Avenue of "thfe Americas New York, NY 10036 Re: J-M A/C Pipe Corporation General Liability & Workers' Compensation Insurance Dear Mr. Payne: Your letter of August 19, 1986, addressed to Ms. Shawn M. Medvin, has been forwarded to me for my attention. As you are aware, the Federal 0SHA has recently lowered the asbestos exposure standard from 2.0 f/cc to 0.2 f/cc. However, our most recent asbestos survey (copy attached) has revealed that only nine out of thirty (i.e., 307.) airborne asbestos samples tested in Stockton plant were in excess of the new OSHA standard of 0.2 f/cc. The situation was even better at the Denison plant, only two out of thirty-one (i.e., 6.45%) airborne asbestos samples tested were in excess of 0.2 f/cc. In other words, the airborne asbestos concentrations of most samples tested were below the new OSHA permissible exposure limit of 0.2 f/cc averaged over an eight-hour time period. Even for those workers who have been exposed to airborne asbestos concentrations greater than 0.2 f/cc, are well-protected by respirators. In fact, ESIS, Inc. has already conducted an asbestos survey for Stockton Plant in this past August and will do the same thing for Denison plant this month.' We will, again, examine the survey data when they become available in the near future. It should be further noted that the airborne asbestos concentrations can be greatly reduced by maintaining an effective ventilation system and following established FPC 00472 SC-JMM-3235 Mr. Gerald John Payne September 5, 1986 Page Two proper work practices. In addition, workers' exposure can also be minimized by shortening the work shift (i:e.', the exposure duration) and wearing respirators. In summary, the J-M . A/C pipe operation is still in good shape; most sampling stations are in compliance . with the new 05HA exposure standard, and all related workers are properly protected by respirators. If you still have doubt, I suggest that a meeting be scheduled in the near future. All parties involved can then discuss this matter in greater detail: Sineerplv vnnrc ' Corporate Environmental Control EEW-.cl cc: Mr. Ron Moreland, CIGNA Mr. Homer Hsieh, J-M Ms.-r FPC 00473 TABLE 1 RESULTS SUMMARY OF SEMI-ANNUAL ASBESTOS SURVEY at . J-M Mfg. Inc., Denison, Texas March 31, 1986 Galson Project #S6-350-00 Location Employee's Name operations Exposure* Sample Sampling Level I.D. Duration Fibers/cc l Jimmy Lang 13* Utility Oper. 5756 254 2 Ed Heironimus 13' PM Tender 5757 246 3 Tommy Martin Gen. Worker 5778 279 4 Ray Terrell 13' PM Head Curer 5758 243 5 Cecil Bell 13' PM Curer 5774 239 6 Charlie Moore 13 1 Control Oper. 5771 250 7 Lewis Ives 13' EM Asst Serv 5766 270 8 Phillip French 13 * Service Opr 5773 218 9 Charles Wilson 13* PM stm Tank Opr 5759 263 10 Arlis Chambers Salvage Trk Driver 5763 259 11 Dale Kent Willow Operator 12 Pete Turnbull . Boiler oprator 13 Bill Rogers UPL Operator 14 Glen Weger UPL Helper 15 James Walsh UPL Inspector 5820 5775 5764 5768 5765 260 260 255 253 252 16 Roger Cam Janitor 5761 306 17 Dock Dill UPL Hydrotester Opr 5824 252 18 Raymond Hesse 131 Unit Leader 5809 . 248 .19 Jeck Bartley 18000# Trk Driver 5776 249 20 Thurman Stanley MOA Operator 5777 246 21 Wilbur Greene Tool Room Opr 5762 246 22 Don Dutton Molder 5787 168 23 Elliott Brown Crew leader 5792 167 24 Fredie Wright Utility Trk Driver 5803 216 25 Bill Williams Electrician 5793 125 26 Murel Abernathy Mechanic 5B02 120 27 Jerry Bruce Platform Trk Driver 5782 248 28 Jack Hansard Sm Fork Trk Driver 5788 244 29 James Bush Sample Plan Insp. . 5815 240 30 Henry Coldiron In Process Insp. 5788 240 31 Lawrence Arnold Slash Saw Opr 5805 240 0.09 0.16 0.10 0.13 0.15 0.16 0.21 0.11 < 0.02 0.02 0.19 < 0.02 0.09 0.03 0.09 0.05 0.04 0.06 0.03 0.04 0.05 0.04 0.03 0.02 < 0.03 0.04 0.08 0.03 0.08 0.03 1.08 * the locations correspond to those marked on Figure 1. * actual and estimated whole day time-weighted-average exposure level. 5 FPC 00476 TABLE la RESULTS SUMMARY OF SEMI-ANNUAL ASBESTOS SURVEY (Exposures less than 0.10 fibers/cc) J-M Mfg. Inc., Stockton, California April 4, 1986 Galeon Project SS6-350-01 Employee's Name Location* (J-M Number) Operations Exposure Sampling Level+ Sample Duration (fibers l.D. (min) per cc) 30 Area Sample - (Lunchroom--top of 5812 247 (D-14WE) food machines) 27 Area Samole (Main Office--top 5811 256 (D-14S) of file cabinets) 23 Richard Gerhart QC Auditor 5814 256 (D-10S) 24 Area Sample (Waste Dump) 5819 253 (D--11S) 22 Brenda Ganner Power Sweeper Opr 5801 298 (D-5S) 13 John Gaines Power Truck Opr 5794 263 (D-7S) 10 Area Samole (Coupling Tester) 5784 274 (D-27F) 26 Tom Corralez Forklift Opr/ 5806 232 (D-13S) Shipping Checker 17 Elliott Rutledge #3 PM Floorman 5785 251 (D-BWE) 28 Jerald Thornhill Warehouseman 5807 237 (D-3S) 16 Wanda Billberry #3 PM #1 Floorman 5799 271 (D-BWE) 14 Betty Spearman Laundry Room Opr 5795 298 (D-12S) 3 Paul Placencia #2 UPL Inspector 5769 252 (D-ibf) 4 Joe Ramirez #1 UPL Inspector 5770 255 (D--3 OF) 20 Derrel Bonds #3 Willow Operator 5787 257 (D-5WE) 11 John Castillo Sm MOA Lathe Opr 5790 256 (D-6F) < 0.02 < 0.02 < 0.02 < 0.02 0.02 0.02 0.03 0.03 0.04 0.04 0.06 0.06 0.06 0.07 0.07 jr0.08 * Numbers indicate workstations sampled on figure (1). + Actual and estimated 8-hour, time-weighted-avg. exposure level. FPC 00474 7 TABLE lb RESULTS SUMMARY OF SEMI-ANNUAL ASBESTOS SURVEY (Exposures greater than 0.10 fibers/cc) J-M Mfg. Inc., Stockton, California April 4, 1986 Galson Project #S6-350-01 Employee's- Name Location* (J-M Number) Operations Exposure Sampling Level-*- Sample Duration (fibers I.D. (min) per cc) 15 Jay Brigdon ' Madrell Truck Opr 5796 256 (D-6S) 21 M. Macadangdang Lg Coupling Cut-off 5800 162 (D-8F) Saw 9 Ed Cortez #4 UCL Operator 5783 266 (D--5F) 19 Bob Lozier #3 PM Operator 5789 253 (D-TWE) 2 Ruben Jauregui #2 UPL Inspector 5767 255 (D-19F) 12 Cerilo Acoba #2 UCL Operator 5791 261 (D-3F) 5 Glen Tunn #1 UPL Lathe Opr ` 5772 253 (D-31F) 8 Norma Christian Sm Wet Saw Operator 5781 266 (D-28F) 1 Lauri Miller Toolmaker 5755 252 (D-95) 7 Ben Cavan Lg Wet Saw Operator 5780 298 (D-17F) 18 Rick Brown #3 PM Crewleader. 5786 249 (D-6WE) 6 Mohamed Din #1 UPL Unit Loader 5779 262 (D-32F) 25 Fran Kastlehaun Coupling Operator 5825 240 (D-33F) 31 Area Sample #3 PM Flowthrough 5816 265 (D-17WE) 0.10 0.13 0.14 0.16 0.17 0.24 0.24 0.25 0.27 0.28 0.29 0.46 1.00 1.43 Numbers indicate workstations sampled on figure (1). + Actual and estimated 8-hour, time-weighted-avg. exposure level. . "8~ FPC 00475