Document O3oRpOzeMQ5Qyv7b2JZDOeX6e

Sample Arp.a Choccolocco Creek. 1 mile above Uwy 71 bridge in Talladega County near Anniston, AL Dennison Slough Wilson Reservoir, AL Sample Composition 2 Goldfish 4 Cltnnnpl Catfish 4 Gizzard Shad 1 Rcdcar Sunfish 4 Largemouth Cass 3 Car 6 Gizzard Shad 3 Largemouth Bar.s 3 Redear Sunfish PCIJ'o Cug/sm) 1015/1242 1254 10.5 . 78.8 0.26 . 7.00 - W\t ^ \ in 6i i ^'0 ko,o uf'vlc HONS 002802 Methods Preparation of Samples The fish were collected by state and federal field crews and sliippcd frozen to Duluth. The fish in each sample were homogenized as a composite and given laboratory numbers consecutively from 1 to 58. Sub-samples weighing 30 gms and 20 gms were exhaustively ex tracted with a Soxhlet extractor using a 1:1 mixture of hexane and methylene chloride. The 20 gm sample extract was concentrated and placed on a 20 gra Florisil column. The PCBs and related chemicals were eluted with 250 ml hexane, and the extract was concentrated to 100 ml for Initial EC screening. The 30 gm sample was concentrated to 100 mg/ml lipids in methy lene chloride for cleanup by gel permeation chromatography. The extract was cleaned up by sequential elution of 5 ml aliquots on a bed of SX-2 Bio Reads (Bio Rad Laboratories) using methylene chloride as a solvent. The combined fractions containing the PCBs were passed through a column containing 15 gm Cellte 545 Impregnated with 9 mis of 1:1 H2SO4 and fuming (302 SO5). The extract was concentrated to 1-3 ml for screening with FiD gas chromatography and then GC/MS analysis. Electron Capture CLC Analysis The extracts of the 20 gm tissue samples were analyzed for PCBs using a Hewlett Packard 5700A gas chromatograph equipped with a Model 3352B Laboratory Data System, an automatic sampler, and linearised HONS 002803 2 arson-methane detector. The column was a 6 ft. x 1/8 inch (O.D.) glass column packed with. 80/100 mesh Cas Cla-on Q coated with 4 percent/ 6 percent SE-30/0V-210. The column temperature was programmed from 160C to 220C at 2C/rain. followed by an 8 min. hold at 220C. The chromatograms were interpreted by a program prepared by Mr. Frank Puglisi of the Environmental Research Laboratory - Duluth in which 16 reference PCfl peaks were monitored. Eight reference peaks corresponded to PCBs found in Aroclor 1016 and Arodor 1242, and eight peaks corresponded to PCBs found in Aroclor 1254. The program estimated the quantity of either Aroclor 1016 or 1254 based on the Individual peak areas and then determined the mean and standard deviation of the respective mixtures based on all reference peaks found. Peaks with areas more than twice the standard deviation were considered contami nated by an interfering chemical and were eliminated from the PCB estimate of the mixture. At least 4 of the 8 reference peaks were required to be present before an estimate of the PCB mixture was reported as an recognizable PCB mixture. CC/MS Analysis the extract of the 30 gm tissue samples were first screened using a flame ionization detector (FID) and then by GC/KS using identical GLC conditions. The column was a 6 ft. x 1/8 in. (O.D.) glass column packed with 80/100 mesh Gas Chrom Q coated with 3 percent 0V-101. The temperature was programed from 100C after a 5 min. hold to 225C at 4C/min. MOMS 002804 The CC/}IS analysis was performed on a Varlan Mat CH-5 mass spectrometer1 Interfaced with a Varlan 6021 data system. Spectra were acquired repetitively every 7 seconds during the gas chromato graph elution and, after mass conversion on the 620i computer, were transmitted to a Varlan 620L computer for data formating and analysis The screening of the GC/MS data was accomplished by selecting Iona in the mass spectra of chemicals of interest and searching all of the spectra for the GC peaks where these ions occur most intensely The most rapid screening of this data is the mass chromatogram which Is simply a plot.of the intensity (heigh) of the characteristic ion, or mass, as a function of GC retention time which is stored, in the computer as the spectrum number (i.e. one spectrum every seven seconds) Tills produces a new "gas chromatogram" in which peaks are observed only if a chemical is present that has the selected charac teristic ions. MOMS 002805