Document O3meNabdpjRoVjpGqq2eJp3mK
*6K us
Monsanto Chemical Company
W. S. KRUMMRICH PLANT LABORATORY
STANDARD ANALYTICAL METHOD
PRODUCT
date issued
12/4/57
SMITTEN BY
PAGE
NUMBER
1 OF 6
11,505
APPROVED BY
DWJ
attachments
RFS
Method 10.875. Drawing 155.154,155,157.
TEST
Monsanto Stability
| | SUPERSEDES METHOD THIS FORM ,---- ,
|X| REVISES INSTRUCTIONS
" ""
ISSUED ON q/2"3/52
SCOPE
This method determines the stability of chlorinated benzenes and biphenyls used as dielectrics. Certain components in the dielectric may break down at elevated temperatures to form HC1. The volatile HC1 is swept out of the sample with air, absorbed in water and titrated potentiometrically with silver nitrate.
EQUIPMENT
I a. Heating bath - Drawing No. 155, assembled in our laboratory to maintain a set temperature to within 0.5C. See attached drawing for particulars. Two 5 x 5" stainless steel plates not shown in the drawing are placed on top of the straighten ing vanes in the bottom of the bath.
'-4. Thermoregulator - American Instrument Co., Silver Springs, Maryland, Cat. No. 4-255.
`--2. Relay - Our relay is fabricated in our own laboratory, but any sensitive, reliable relay can be used.
2 5* Lo-Lag heater - 500 watt, 110 volt, American Instrument Co., Silver Springs, Maryland, Cat. No. 5-404.
4. Variac - 115 volt input. General Radio Corp., Cambridge 39, Mass., Type V-20M
- 5* Strip heater - 500 watt, 110 volt, General Electric Co., Cat. No. 2A-404.
~r-6. Stirring motor - l/5 H.P. Bodine motor. General Radio Co., Chicago, 111., Type NSE-12.
;v7 i. i 8.
r
j 9.
Powerstat - The Superior Electrical Co., Bristol, Conn.
Stirrer - 4 bladed i metal, 10-1/2" long, American Instrument Co., Cat. No. 4-640.
Bath fluid - Dow Corning 550, Dow Corning Corp. Midland,
Mich.
- ,____
DSW 551093
STLCOPCB4089510
Product: Aroclors, Pyranols, and Electrical Grade Chlorobenzenes
Test: Monsanto Stability
Method No. 11,503 Page 2 of 6 pages
The heating bath is essentially a 29" x 7" x 8" bath made from #16 gauge 316 SS which has been insulated with 1" of Magnesia. The three 500 watt strip heaters are connected to the variac. The thermoregulator controls the relay for the Lo-Lag heater. The bath temperature is regulated with the strip heaters to 210C. and then che thermoregulator is set to control the temperature within 0.5C. The powerstat controls the stirring motor speed at a rate to maintain a uniform temperature throughout the bath.
2 b. '
Air supply - 40 psi air is reduced to 8 psi by a pressure regulator. The 8 psi air is purified by passing through an empty trap, a scrubber bottle containing 20$ NaOH, a second empty trap, a scrubber bottle containing C.P. H2S04* a third empty trap, and a vapor trap immersed in dry ice and acetone. The purified air line is connected to a capillary tube, cut to regulate the pressure at 24 - 26 mm Hg. on the manometer, and then to a glass T; one side going to a 6" mercury manometer, the other side going to a glass manifold having one connection for each sample. Capillaries are cut to a length that permits a flow of 45 ml. per minute of air and inserted between the manifold and the inlet down tube of the absorption flask.
lyl. Empty traps - 1000 ml. filtering flask, Fisher Scientific Co., Cat. No. 10-180.
;> 2. Scrubbers - Fisher-Milligan Gas Washer, Fisher Scientific Co., Cat. No. 7-513
\ 3- Flow meter - Fisher Scientific Co., Cat. No. 11-163,
fitted with flowrator tube No. O8-150/13.
\j 4. Vapor trap - fabricated by our glassblower according to specifications given on Drawing No. 153-
i 5.
Evacuated flask, 1 quart capacity - Fisher Scientific Co., Cat. No. 10-197. The flask is wrapped with plastic tape to help prevent injury by flying glass should the flask be accidentally broken.
i 6. Pressure regulator - outlet pressure range, actual j 0-35 psi, Fisher Governor Co., Marshalltown, Iowa.
7. Capillaries, 0.25 nim I.D. - Fisher Scientific Co., ; Cat. No. 11-367.
qSnN 55A09A
{
7
STLCOPCB4089511
'1
Produet: Aroclors, Pyranols, and Electrical Grade Chlorobenzenes
Test: Monsanto Stability
Method No. 11,505 Page 5 of 6 pages
j.
8. Flask, 500 ml. Erlenmeyer with 54/45 S Joint - Ace Glass Co., Vineland, N. J.
9. Absorption flasks - Fabricated in our laboratory from 125 ml. Volhard flask, E. H. Sargent and Co., Cat. No. S-65585. See Drawing No. 154.
c. Potentiometer - our potentiometer is fabricated in our
laboratory, but any sensitive, reliable potentiometer can
\ . v;.be used.
A (>- \ '
-
.} ^
V d. Silver wire electrode - B and S #12.gauge silver wire. Handy
and Harman, 1800 W. Kenzie, Chicago 22, Illinois. .
/e.
Mercurous sulfate reference electrode - modified L and N calomel reference electrode, L and N #7724-6-P2 (inner element) and #7724-6-Pl (outer element). Prepared as follows: Dismantle the internal element from the salt bridge tube of a standard L and N calomel reference electrode. Discard the saturated KC1 solution from the tube and clean out the mercurous chloride and mercury from the internal element. Clean the parts thoroughly. Add sufficient new clean mercury to the internal element to make contact with the electrode wire and repack chamber of internal element with mercurous sulfate moistened with 0.5 H potassium sulfate. Seal the chamber with non-absorbant cotton. Fill the salt bridge tube with 0.5 :M potassium sulfate and re assemble units.
f. Magnetic stirrer - Labline Inc., Chicago, 111., Cat. No. 1250 with plastic coated stirring bar.
g.
7 h.
Buret, 1.0 ml. microburet - Koch-Fisher Scientific Go., Cat. No. 20-110.
Other usual laboratory glassware.
REAGENTS
a. Acetone - Technical grade. Carbon and Carbide Chemical Co., or equivalent. A blank determination of the acetone must'
not exceed 0.05 mtlo. ooifr0.005 N AgNOs*
b. Silver nitrate, 0.005 N solution, A.R. grade - Mailinckrodt Chemical Co., Cat. No. 2169. Make a 0.1 N solution by diluting 16.99 g. A.R. AgNOs to 1 liter. Take 50 ml. of this solution and dilute to 1000 ml, store in a dark bottle.
0SNfJ 551095
STLCOPCB4089512
Product: Aroclors, Pyranols, and Electrical Grade Chlorobenzenes
Test: Monsanto Stability
Method No. 11,503 Page 5 of 6 pages
Cover the oil bath with the transite boards and the exposed 'v part of the flasks with aluminum foil.
-6. Bubble air through the sample for 16 hours at the rate of 45 ml. per minute.
07* Disconnect the air supply.
8. Remove the absorption flask and transfer the contents to a
2 a* 2.00 jnl. beaker, rinsing fthe absorption flask into the beaker ----: wlthtwo 5 ml. portions of distilled- water.
9* Add 50-ml. of acetone and 2 drops of 1% HNOa to the beaker.
10.Titrate the sample potentiometrically following the procedure " outlined in General Method No. 35 > WGK Method No. 10,873 with
the following modifications:
a. Use a Ag-Hg-Hg2S0.4j 0.5 M K2SO4 electrode system. OOli'r
b. Use 0.-OO5-N AgN03.
c. Use a magnetic stirrer.
d. Titrate to the maximum change in potential, usually
between 75 and 100 mv.
^
CALCULATION.
_----^
f1 *
/ 9\y
x-N x--0354-57 x 100-x-10,000-
gET
--
5..ml. 0.005 N AgNOa x 0.6l
Report results to the nearest 0.1 ppm.
Duplicate results should check within 0.04 ppm.
PRECISION'
/ Based on 20 duplicate determi^iations,,by different analysts using
/ different apparatus. The standard deviation of this method is
- 0.04 ppm.
/ /`
^ DISCUSSION i '
jI
j. j I
.
The precision of the method!is based on material having a chloride
content of approximately 0. ppm. Our material is normally in
551096
pS\N
STLCOPCB4089513
Product: Aroclors, Pyranols, and Electrical
Grade Chlorobenzenes Test: Monsanto Stability
Method No. 11,503 Page 6 of 6 pages
this range so no effort has been made to estimate precision at higher concentrations.
For directions on the setting and wiring of the thermoregulator, consult "Instructions for 'Quickset1 Bimetallic Thermoregulator
- Instructions No. 545" supplied by American Instrument Co., Silver Springs, Maryland.
The apparatus Is cleaned with acetone to remove the dielectric
and then rinsed thoroughly with distilled water. After the
distilled water rinse, check the last water rinse from the
flask for chlorides by the Tyndall beam method using 10$
AgN03 solution. The water must be beam free at the end of
45 seconds. If a beam appears, wash the apparatus until the
distilled water is beam free. Dry the apparatus In an oven
before use.
.
In case the electrode system shows abnormal behavior. It may be checked by titrating a standard chloride solution. Prepare a 1.00 ppm standard by diluting 1.64 ml. of 0.5 N HC1 to 1000 ml. In a volumetric flask with distilled water. Dilute a 10 ml. aliquot with 50 - 75 ml. methanol in a 100 ml. beaker and titrate with 0.005 N AgN03. Calculate the ppm chlorides in dicated by the titration and compare with the standard value. Fresh standard should be prepared each time.
REFERENCE
a. Laboratory Notebook Reference: 148, 47.
b. "Instructions for 'Quickset' Bimetallic Thermoregulator"
- Instructions No. 545* American Instrument Co. Inc., Silver Springs, Maryland.
"The Information contained herein is, to our best knowledge, accurate; but all recommendations or suggestions are made without guarantee, since the conditions of use are beyond our control. Monsanto disclaims any liability for loss or damage Incurred in connection with the use of the above."
I
OS\N 551097
STLCOPCB4089514