Document O3b55wO9N3zygqryppLyR2djp
IViltACRON
To B. Ransdell ^
CC W. Eckerson L. Treat G. Baldwin R. Hempelmann
B IU
From
Marko Paliobagis Larry Hogan Kathy Lautenschlegar
Location
Date February 23, 1977 Subject Airborne Asbestos Concentratio:
Diamond Room, Products Divisio:
COMPANY CONFIDENTIAL
The workroom atmosphere of the Diamond Room of Products was tested for airborne asbestos fibers on Saturday morning, January 22, 1977. During this period normal production practices were being followed and Plenco, an asbestos containing material,was being used. In this investigation both personal samples and fix point samples were obtained. The actual asbestos analysis was done by Kettering Laboratory, University of Cincinnati.
Z
The current-OSHA .compliance level for asbestos fibers is .^8''fibers per cubic centimeter of workroom air, with the fibers having a length greater than 5 microns.
The results of this investigation indicated that all samples collected were below this OSHA compliance level.
One of the fixed point samples, directly above the lathe cutting operation, indicated a level of 3.7 fibers/cc. While this is below the OSHA 5 fibers/cc level, we would recommend that a proper exhaust hood system -be installed on this lathe; for all practical considerations this would eliminate exposure to asbestos fibers to the employees in the Diamond Room.
It was noted during one period of the above tests, that there was excessive
uncontrolled use ci -.ir hoses in other operations in the Lrsr.or.i
This
can only lead to the unnecessary increase of dust levels ir. this room.
In conclusion, we find no reason why the Plenco asbestos material cannot be safely used if the above minimal recommendation is carried out.
- PLAINTIFF'S EXHIBIT CGI-11
MIL 000012
Technical Report will follow. rm
MIL 000013
A/iSLACROM
To B. Ransdell
CC W. Eckerson L. Treat G. Baldwin R. Hempelmann fj, CrrifhikS
COMPANY CONFIDENTIAL
iWSfcSS 2 aU*
From
Marko Paliobagis Larry Hogan Kathy Lautenschlegar
Location
Date February 23, 1977
Subject Airborne Asbestos Concentratic: Diamond Room, Products Divisior
Summary
The workroom atmosphere of the Diamond Room of Products was tested for
airborne asbestos fibers on Saturday morning, January 22, 1977. During this
period normal production practices were being followed and Plenco, an
asbestos containing material,was being used. In this investigation both
personal samples and fix point samples were obtained. The actual asbestos
analysis was done by Kettering Laboratory, University of Cincinnati. .
t
The current OSHA compliance level for asbestos fibers is *5. fibers per cubic centimeter of workroom air, with the fibers having a length greater than . . 5 microns.
The results of this investigation indicated that all samples collected were below this OSHA compliance level.
One .of the fixed point samples, directly above the lathe cutting operation, indicated a level of 3.7 fibers/.cc. . While this is below the OSHA 5 fibers/cc level, we would recommend that a proper exhaust hood system be installed on this lathe; for all practical considerations this would eliminate exposure to asbestos fibers to the employees in the Diamond Room.
It was noted during the period of the above res-.3. char there was excessive uncontrolled use cf air r.cses rn ocher cceracrons rr. me Diamond Room. T-'._s can only lead to the unnecessary increase of dust levels in this room.
#
In conclusion, we find no reason why the Plenco asbestos material cannot be safely used if the above minimal recommendation is carried out.
MIL 000014
Technical Report will follow.
M. Paliobagis/ rm
L. Hogan
X'ad,/ lf,UT7v.y/^,
K. Lautenschlegar
MIL 000015