Document O3MVogRjxzo6y3eoL7NVDK1Yw

Boiler Number [ S-Hr. Rating Sq. F t. Steam Crate Area, 1Sq. F t. Height to Top Outlet, In. Height Water line, In. Ashpit, Inside, In . Number Height to 1 of Outlet, Inches Nominal Di of Grate Inches SizeSmokeInches Height of W aterline Inches [Number an ISize of Out jInches Number an Size of lnle Inches D irect Rai` tion Boiler supply at 8* firing perio< Boilers Richardson & Boynton Co. Manufacturers of "RICHARDSON" "PERFECT" Heating and Cooking Apparatus Since 1837 Executive Offices: 260 Fifth Avenue, NEW YORK CITY Chicago Philadelphia Providence Boston Rochester Buffalo Cleveland Albany Detroit Minneapolis St. Louis Springfield Pittsburgh RICHARDSON ROUND BOILERS Ratings and Dimensions Height to Top Outlets Direct Boiler No. 8-Hour 8-Hour Rating Rating Sq.Ft. Sq.Ft. Steam Water Nom. Diam. Crate In. Grate Area Sq.Ft. Outle t. In.* Height - and Water Inlets Line No. Steam Water In. and Rad. Boiler will Supply Size Sq. Ft. 1190 300 500 19 1.97 47% 45% 42% 2-2% 200 1191 350 575 19 1.97 51% 49'/, 46'/2 2-2% 235 1192 375 625 19 1.97 55% 53'/, 50'/2 2-2% 250 1221 450 750 22 2.64 53 Ml'/, 48'/. 2-2% 300 1222 500 825 22 2.64 57 M'/, 52'/, 2-2% 335 1223 550 900 22 2.64 61 38'/, 56V, 2-2'/$ 375 1251 625 1025 25 3.41 mv7 52 49'/, 2-3 410 1252 675 1100 25 3.41 58% 56 53'/, 2-3 450 1253 725 1200 25 3.41 62'/, 60 57% 2-3 460 1261 875 1350 28 4.28 55% 53'/* 51 2-3% 600 1282 950 1550 28 4.28 59% 57'/. 55 2-3% 650 1283 1025 1675 28 4.28 63% 61'/. 59 2-3% 700 * Richardson Round Boiler RICHARDSON SECTIONAL BOILER Ratings and Dimensions co V . OS ^ c On Z <9 255C 1000 1600 4.57 55 48% 27%*35% 2-3% 256C 1250 2000 5.7(1 55 48% 27%x42% 2-3% 257C 1500 2400 6.83 55 48>/, 27%x50 2-3% 258C 1700 2800 7.97 55 481/, 271/2x57'/. 2-3'/2 355C 1950 3125 7.85 63 56 39 i33% 2-4 356C 2400 3850 9.81 63 56 39 *41% 2-4 357C .2850 4575 11.75 63 56 39 x50 3-4 358G 3300 5300 13.70 63 56 39 x58'/4 3-4 359C 3750 6025 15.65 63 56 39 166% 3-4 427C 3500 5600 13.82 66 60 45 x50 7-5 423C -4050 6500 16.11 66 60 45 x58'/4 2-5 479C. 4600 7400 18.40 66 60 45 ,661/2 2-5 4210C 5150 8300 20.69 66 60 45 *74% 3-5 42IIC .5700 9200 22,98 66 60 45 x83 VS 536 6300 10000 18.94 82 70'/, 55 x55 2-6 537 /300 11600 22.68 82 70'/, 55 *65% 2-6. 538 8300 13200 26.40 82 70'/, 55 *76% 3-6 539 9300 14800 30.12 82 70'/2 55 *87% 3-6 5310 10300 16400 33.88 82 55 x98 3-6 362 Richardson End Feed Sectional Steam Boiler Richardson & Boynton Co. Boilers SMOKELESS ROUND BOILERS Ratings and Dimensions Steam a a -O JH *o S ;= g < Sit ee c tS S-432 53V7 23 2.89 9 48% 2-3 2-3 320 sqit. 700 S-532 57V4 23 2.89 9 52% 2-3 2-3 350 " 750 S-632 62 23 2.89 9 56% 2-3 2-3 380 * 800 S-462 55'/2 26 3.70 10 40'/, 2-3% 2-3% 450 " 900 S-562 59Vi 26 3.70 10 53% 2-3'/, 2-3% 500 0 1000 S-662 64 26 3.70 10 58 2-3% 2-3% 550 a 1100 S-492 60 29 4.58 10 53% 2-3% 2-3% 630 a 1250 S-592 65V* 29 4.58 10 38% 2-3% 2-3% 700 * 1350 S-692 70% 29 4.58 10 64% 2-3% 2-3% 770 " 1450 Water W-432 45V4 23 2.89 9 W-532 50 23 2.89 9 W-632 54'/4 23 2.89 9 W-462 47'/g 26 3.70 10 W-562 51 Vs 26 3.70 10 W-662 555/a 26 3.70 10 W-492 50>/2 29 4.58 10 W-592 55% 29 4.58 to W-692 61% 29 4.58 10 2-3 2-3 2-3 2-3% 2-3'/, 2-3% 2-3% 2-3% 2-3% 2-3 520 sq.ft. 1(50 2-3 570 " 1225 2-3 620 1300 2-3% 725 " 1500 2-3% 800 " 1650 2-3% 875 " 1800 2-3% 1025 * 2050 2-3% 1125 " 2225 2-3% 1225 2400 Richardson Round Smokeless Boiler Direct radiation boiler will supply, is based on the use of cast-iron radiation in a 70 F. temperature and with the assumption that the Boiler and Piping system is thoroughly covered in the usual manner. For churches, garages, schools, or where pipe coils, wall or indirect radiation is used, the tax on the boiler must be figured on a basis equivalent to cast-iron radiation as above. When coils or indirect water heaters are used in connection with steam and water boilers, for heating water for domestic purposes, additional capacity must be figured at the rate of 1H square feet of direct radiation for a steam boiler; and 2lA square feet of direct radiation for a hot water boiler, for each gallon of water to be heated per hour. Height of chimney for 23" series, 35 feet; 26" series, 40 feet; 29" series, Inside area of chimney flue, 23" series, 96 sq. in.; 26" series. 96 sq. series, 144 sq. in. RICHARDSON HOT BLAST SMOKELESS BOILERS End Feed Sectional Steam and Water Special features of the "Richardson" Hot Blast Smokeless Boilers "C" Series. They are made in sectional form and can be erected at any time, whether the build ing is new or old. This enables the boiler to be installed with a minimum handling expense. The natural fire travel and draft eliminate excessive heights in chimneys. Long smoke travel and no obstruction to the flames, aid combustion to the perfection point and utilise maximum beat from the fueL "Y" Flue Construction equalises the circulation and assures a steady water line. . Overhanging prime heating'surfaces are at the maximum, producing 'the highest evaporative power. During the process of the fuel-coking; gases are drawn back into a large chamber in front of the bridgewall, which has two port holes at the top center, making it impossible for gases to accumulate and explode. The base is made in sections, permitting enlargement of a boiler if ever necessary. Fire door: Replacing of grates through fire door big enough for man to enter (15x20 inches) means important saving in tune. The size of this door permits even distribution of fuel over the fire. Made in sizes 1850-16,150 sq. ft. for steam Made in sizes 3000-26,600 sq. ft. for water 363