Document O39NvXnd8GN70qn5R7byEeqve

American Society of Heating and Ventilating Engineers Guide~J935^ Convectors 20 in. or lower may have a heating effect of 15 per cent included rating; for higher convectors, 1 per cent shall be deducted for each 1 in. jncr,, height above 20 in. No heating effect shall be included in the ratings for conv S with a cabinet 35 in. from the floor to the top, or higher. All ratings published wilM^ definitely that this heating effect factor is included in the catalog ratings. S"Y Concealed heaters or convectors are generally sold as completer5" built-in units. The enclosing cabinet should be designed with suitabl^ air inlet and outlet grilles to give the heating element its best performance6 Tables of capacities are catalogued for various lengths, depths and heights and combinations are available in several styles for installations, such ?s the wall hanging type, free-standing floor type, recess type set flush with wall or offset, and the completely concealed type. Most of these types may be arranged with a top outlet grille, although the front outlet is practically standard. In cases where enclosures are to be used but are not furnished by the heater manufacturer, it is important that the pro portions of the cabinet and the grilles be so designed that they will not impair the performance of the assembled convector. The output of a concealed' heater, for any given length and depth, is a variable of the height. Published ratings are generally given in terms of equivalent square feet, corrected for heating effect. However, an extended surface heating unit is entirely different structurally and physically from a direct radiator and, since it has no area measurement corresponding to the heating surface of a radiator, many engineers believe that the per formance of convectors should be stated in Btu's. For steam convectors, as for radiators, 240 Btu per hour may be taken as an equivalent square foot of radiation. CODE TESTS FOR RADIATORS AND CONVECTORS As previously indicated, the output of radiators and convectors is still designated by the terms of older practice, but this is gradually giving place to an engineering method of designating heat emission. The A.S.H.V.E. has adopted the following standards: Code for Testing Radiators (1927); Codes for Testing and Rating Concealed Gravity Type Radiation (Steam, 1932, and Hot Water, 1933). c For steam services the actual condensation weight is taken without any allowance for heating effect; for hot water services the weight of circulated water is used without allowance for heating effect. In all^cases the total heat transmission varies as the 1.3 power of the temperature difference between that inside the radiator and the air in the room, and is expressed in Btu or Mb per hour. Standard test conditions specify either a steam pressure of 1 lb gage (215 F), or hot water at 170 F and a room temperature of 70 F for radi ators, or an inlet air temperature of 65 F for convectors. The heating capacity of a steam radiator or steam convector is determined as follows: Ht = Wsh,g (1) where Ht -- Btu per hour under test conditions. We = condensation in lb per hour. fcsg = latent heat in Btu per lb. 498 6f radiators: ,, /215 - 70V-3 ( 145 \l-3 8 \Ts-Tr) Vn-rJ (2) .vr>;..rv<S.vi-^.f."0r convectors: ,, V/2r1,5 -- r6i5/V'3 " V/ r,is-o rJy.3 v The output under standard conditions will be: Hs - Cs Ht (3) (4) where . r Cf,s -=. ccsooterrarreemcctttiieoomnn pffaaeccrtatootrur.re during test, degrees Fahrenheit. St = room temperature during test, degrees Fahrenheit. Tj - inlet air temperature during test, degrees Fahrenheit. Hs =* heat emission rating under standard conditions, Btu per hour. Similarly, for hot water convectors, the output under test conditions may e determined as follows: ..... ,, N 3600 ,H W (6i -- e) (5) where Btu per hour under test conditions. paovuenradgseotfewmapteerrahtuarnedolefdindleutrinwgatteers,td. egrees Fahrenheit. average temperature of. outlet water, degrees Fahrenheit. Ul -- O.v.v-0^ . i =; duration of test, seconds. To convert test results to standard conditions, the following correction factor is used: - ^_L+ -- 7i J \-S" L / (6) \* /. X. It has been shown that when the exponent 1.3 is used'the range of error is less than 5 per cent8. GRAVITY-INDIRECT HEATING SYSTEMS8 The heating units for this system are usually of the extended surface type for steam or hot water, and are installed about as shown in Fig. 6. Tests of Coavecton is a Wans Wall Testing Booth, by A. P. Kratz, M. K. Fahnestock, and G. L. Broderick {Beat'ing', Piping andtAhiisrsCuobnjedcittioseneinAg.,SA.Hug.Vu.sEt,. C19o3d3e)o. f Minimum Requirements for the Heating * Equipment of Buildings, by Harding and