Document O34DJkw3Y06L6mK2L0BndVazQ

'S, J- A & * Interoffice Communication _> To From Date1/ 4 Subject A. F. Gallagher4' L. Gi Peyton T April 24, 1974 * Personnel Monitoring Program % Objective: To determine plant personnel exposure to vinyl chloride monomer using portable personnel mounted collection devices. To record, analyze and file the results as a means for controlling VCM levels well below the QSHA standard. Plan: , ii bH j The plant will be broken into areas of study in which each job classifica tion will be monitored to include all probable operations which would subject, an employee to VCM... All classifications within the areas will be monitored weekly until the time that the area shows a 3 week history of less than OSHA standard. When a 3 week "Clean History" is attained that area will then be monitored once per month unless a high level is recorded. At the time a high level is noticed the area will be monitored again on a weekly schedule until a "Clean History" (3 weeks less than standard) is developed. * Method: , VCM collection with a charcoal impinger at 1.5 liter/minute for 2 to 4 hour period depending on job activity. Analysis of the recovered gas with a GC to produce VCM in ppm. Monitoring will be conducted while an employee is in the area of concern and unprotected (i.e. Reactor people will not be monitored while they leave the area for a break. Employees will not be monitored while wearing an air mask). Data: ' <T All results will be determined by GC in the Aberdeen Analytical Lab and reviewed by Dr. F. J. Scott. He will relay the data to safety director. Bob Freele, who will maintain a filing record as outlined and in accordance with OSHA regulations. * ** * Data taken will relate the employee's name, area worked in, job classifi cation, sample period, sample date, and analytical^results. See attachment 1. The safety department will be responsible for completion of the data sheets. The laboratory supervisor, safety driector, and analyst will t VAB.0001042952 #4 Personnel Monitoring Program April 24, 1974 PagO 2 Data: (Con't) gnature Schedule: ---1------ -- It is the responsibility of the safety department and plant operations to have the dosimeters and personnel available for monitoring dictated by the schedule and/or necessity. Area 1 Management Offices Warehouse VTN'SvvjCaA- General Maintenance Shop Instrument/Electrical Shop Engineering/Drafting Offices 0\ r-u\ 0^<'vr' Area 2 * Vinyl Blending Mid Compounding Operat C - S\ Aytot f vcA. IXWAy j ^Wvods. O9 ^ * <A> v- Area 3 Laboratory Laboratory Supervisors Offices Area 4 (2, kv-yA* "Acc\\. C_e> AiC>\ ZiJ>V ^ iV > V- '* V, v Cf Vs Yard Yard Yard Area General VCM Unloading and Transfer Resin/Compounding Loading and Unloading Bulk Container Cleaning \ Dryer Storage Bin (Tops) Dry Resin Transfer S Slurry Switching Sta Slurry Storage Tanks 'v VKS cSvV yyfc If 'vV'V' i\v V \ tor* h'^' '*~f *r Area 6 V-12 Reactor Building Area 7 CV\ecV c V^ eye. 09 e v icA'fc'r Vj ' O Os\ ' X'A'J V-ll Reactor Building D-300/400 Reaction Area C, Vi f Vi 0^<?r ^At>v C.> l 0 y (? ^ \o O W, \y \ \ . cAc, sr OA A A si L K v <* t * p ^^ 'V V- Dy^ l (Jl v to v{ i V t \ *' > o'V S Vcs Cj OcV'A-Vv I KJ WtvV TecV1 r ,|l -jS" i 'J VAB.0001042953 I Personnel Monitoring Program April 24, 1974 Page 3 m ( Schedule: (Con*t) * Area 8 v * V-10 Reactor and Dryer Building "X^xx^^ovv\^ ^ Monday *3 ^ Morning -Area 1 + A * Management Offices Cindies Purchasing) B Warehouse (Utility or Fork Truck Operator) C Vinyl Bagger m* Afternoon - Area 1 D Maintenance Shop E Engineering/Drafting Office F Instrument Shop * Tuesday i Morning - Area 2 A Dry Blend B Compound Operator/Helper C Plasticizer Afternoon - Area 3 w # . D Resin Tech * E Compound/Development Tech F Supervisor Wednesday Morning .-t* . 'A.-- , A B C M, - Area 4 #- VCM Unloading and Resin/Compounding Pond Sampling * Transfer Loading and Container 't rfc. i.lf-. vt V \ Cleaning Afternoon - Area 5 '# r 1 '+< D Dryer Operation - E Storage Bin Measuring/Resin Transfer Line F Slurry Line Switching ^ Thursday Morning - Area 5 . A Slurry Storage Tank Cleaning/Area B Dryer Utility Clean up < h h + r '* L /v i-T*.-*' fc, ? ^ ' - . - fci. * VAB.0001042954 .r'exsonne- ,,1 v.on:. coring rrogran April#24, 1974 Page 4 Schedule: (Con't) 4 i Thursday Iw mm Morning - Area 6 I a*' C V-12 Recovery Operator Afternoon - Area 6 **'m D v 12 Utility E V 12 Maintenance (General or Instrument) F V-12 Charge Operator Friday Morning - Area 7 A V-ll Utility, B V-il Recovery 6 V4i Charge **-*- * i- ^* Afternoon - Area 7 D D- 300/400 Lead 300/400 A Operator F F V- f>f)Cv ` D-300/400 V- n - ; Maintenance (Include Vinyl Shop) A k \ l Ml t. ' i jLI . K' *-4 .% \h Senior Process Engineer sw s\ cc: HMS, GKP, RWS, LNK, KWC, JES, RJF, FJS, TRL cc: K"s . g: *, r- j**#*0m * -f *''&** r V-'li*. V***. Tl t i- *' - - * j - * * t --- -'"V / :- * VAB.0001042955.