712 CHAPTER 67 1962 Guide And Data Book Table l .... Average Maximum Wet-Bulb Temperature in Toronto Area, Season 1950-1951 Seotember *56.3 February 22 October 45.3 March 28 November December 35.5 27 April May 38-2 48.3 January 26.7 June 5S.2 fig. \ .... Heat Transfer from Air to ice Surface as Affected by Air Velocity and Temperature to the many variable factors which enter into the calculation. Empirical values needed for calculation of the refrigeration requirements are based on data obtained from a test of 50 ice rink installations used for a wide variety of purposes, in Toronto, Canada, and its environs. It was found that some rinks, such as private clubs and figure aVating, have very light usage, except for a few hours daily and on weekends. However, they may be in use during shows or bonspiels for fig. 2 .... Effect of Relative Humidity on Heat Transfer from Air to ke Surface 18 hr per day during one week of a season. Community rinks have been used for hockey practice, free children skating, figure aVoting, and public aWting all in the same day, almost around the dock, or as much as 20 to 22 hours per day. On such rinks the service factor is much heavier than on rinks used only a few hours per day. Since, in many cases, it was impossible to foretell in ad vance the service factor to apply when a new rink was con templated, data were obtained from a number of rinks under average conditions. Tables and curves were drawn for the actual performance of the machinery, based on acceptable conditions of the ice for the intended purpose. The average wet-bulb temperature for each month of the wlrafing pragnn as shown in Table 1 was obtained from the Toronto weather bureau station. The total heat flow in Btuh per square foot was calculated and is shown graphically in Fig. 3 which was derived from Figs. 1 and 2. This heat flow will apply to all rinks at various average maximum monthly outdoor wet-bulb temperatures. The internal wet-bulb tem peratures will follow thrtgp outdoors but with a lag due to the heat capacity of the building. No attempt was mA/te to take actual readings of the wet- bulb temperature inside and outside the building, since it was felt that to make these readings representative, would require considerable time and would not help the purpose, which was to arrive at average service or load factors for the various types of rink usage. These were determined and are listed in Table 2. By knowing the tonnage of the compressor at operating conditions, and having previously calculated the heat flow, it was only necessary to add the curve at the bottom of Fig. 3 so that the refrigerating requirements could be calculated for any locality or any application. Tests have been made to check the reliability of the curves. Example: Assume a rink for use for hockey and light public skating; size 85 X 185 ft or 15,725 sq ft. The skating season is to be from October to April, the average maximum monthly wet-bulb temperature from Table 1 in the month of October is 45.3 F and in April 38.2 F. Therefore, 45 F may be used as the design wet-bulb temperature. From Table 2, the service factor for hockey and light public pWn-t-ing is 7.5. Then using Fig. 3, at 7.5 service factor and 45 F average wet-bulb temperature, the heat flow per sq ft per hr is found to be 37.5. The cooling load is (37.5)(15,725 sq ft) ------------------------------=49.14 tons refrigeration. 12,000 ICE SEASON The length of the ice season for a hockey or public skating rink depends upon location of the rink. In a metropolitan area it may be financially justified to operate all year. The usual operating season for an indoor rink is from, six to seven months. .. . Open air rinks have not only been installed in localities in moderate climates and below the Mason-Dixon line but w cities where the winter temperature may at times drop t Skating Rinks 713 Table 2 .... Service Factors Hockey rinks and light public skating Heavy public skating Curling rinks All-year figure skating Sports arenas Open air rinks (shaded) 7.5 10.0 5.0 2.5 7.5* 15-20.0 * Doe* not take into consideration the actual freezing of the ice surface (H in. tAj-trn-- in 13 hr at 200 Bto per lb). --40F as in Calgary, Alberta andAmpere, Finland, the latter bring almost within the Arctic Circle. ; If sufficient refrigeration capacity is provided--ice can be maintained even though the sun is shining and warm winds are blowing or even during a rain. TYPE OF ^CLOSURE Almost every type of building material ha* been used' to enclose skating rinks, including galvanised iron, frame, brick and concrete. The latest material to be used is translucent fiber glass panels, which also afford some protection against the sun. The type of construction to be used will depend on the funds, available, on local and climatic conditions and the ex pected maintenance of proper ice and spectators' comfort. When heating during winter is provided; it should be of sufficient capacity to bring the space temperature up to 50 F. V^en the house is filled, the temperature will rise, and ven tilation must be provided for the spectators' comfort. SELECTION OF EQUIPMENT For an ice thickness not exceeding 1H in; to be mfttntainaH " average temperature of 26 to 28 F when the average maximum ambient wet-bulb temperature is 45 F, the follow ing brine temperatures are sufficiently low at: 16 F for hockey, 18 F for public skating, and 20 F for curling. As wet-bulb temperature increases the temperature of the ice must be lowered one or more deg to maintain the same condition of ice given for 45 F wet-bulb. The compressor should be selected to operate at a suction pressure not exceeding 10 F mean temperature difference between brine in the rink surface and the primary refrigerant. A suction temperature of 5 to 10 F is satisfactory. The refrigeration tonnage may be calculated on a basis of average wet-bulb temperature, using Fig. 3. Since there are seasonal extremes in temperature, as well as service, protec tion should be provided against occasional extremes and against possible compressor breakdown at a critical when ice must be supplied by installation of spare compressor. For sport arenas and open air rinks, three compressors are favored. One compressor usually maintains the surface, the second is usually required when the rink is in use, and the third is used for a fast freeze or as a spare. Many installations have been made without a spare compressor. The evaporator should be of modem conventional Hcgjgn The liquid feed control should be tire most efficient and suitable for the refrigerant used. It should- match tire com pressor capacity under design conditions. The brine pump should be of sufficient capacity to circulate enough brine so that the temperature difference between in coming and outgoing brine does not exceed 1.75 F deg under design conditions. One brine pump is satisfactory for small rinks. A spare pump is always recommended, but if used both should be of full capacity to maintain constant velocity through the piping system and thereby prevent the brine from short circuiting some of the floor pipes. A spare pump will operating troubles. The quantity of brine should be no less than 10 and pref erably 15 gpm per ton for any application. The condensing system and liquid receiver selection will depend on local water supply conditions and type of evapora tor used. When selecting evaporative'condensers considera tion should be given not only to the maximum expected out door wet-bulb temperature during the akating season but also to suitable operating controls and to provide protection against freezing during cold weather in northern areas. Skating Surface Temperature Skaters prefer hard, dry or damp ice surfaces, depending on the use. With proper design and operation these ice condi tions an be obtained within a degree of the desired ice tem perature. Hockey players and curlers prefer hard ice; figure skaters dry ice; and public skaters damp ice. Since it is not practicable to measure the surface tempera ture, it is customary to control the ice sheet condition either from the predetermined brine temperature or from the ice temperature determined from a thermostat bulb embedded in the ice. It has been found that with approximately 45 F wb