Air System Equipment * Fans and Blowers Bayley Blower Company 1817 S. Sixty-Sixth Street Branches in principal cities Milwaukee, Wis. Builders of Heating, Ventilating, Cooling, Purifying, Humidifying and Air Washing Equipment; Exhaust and Drying Apparatus, Mechanical Draft and Blast, Fans and Blowers of all Types Bayley Plexiform Fan: Is a multi-blade fan for supplying air for heating and ventilating systems, manufacturing processes, drying systems, forced and induced draft sys tems. It is suitable for handling high or low temperature gases at medium or low pressure. Will deliver maximum quanti ties requiring minimum space with great economy. This is a distinct Bayley product, high class material and workmanship, properly designed to avoid excessive vibration and overstressing of parts. Inlets and outlets are properly sized for maximum delivery and maximum efficiency. Fans are fur nished in single or double width of any required arrangement and with sleeve or anti-friction bearings. Aeroplex Fan: Is of high speed design with self limiting power characteristics. Application parallel to the Plexiform Fan. Highly efficient and quiet in operation. Bayley Exhausters and Pressure Blowers: Type "B" exhaust fan is for heavy duty, hand ling refuse from industrial and textile plants. Type <4EX" is used in handling smoke, fumes and dust laden gases. Type "H" for high-pressure work. These units are highly efficient and of high class design and workmanship. Bayley Turbo Air Washers, Humidifiers and De-Humidifiers: The Turbo Atomizer used in the Bayley Washer produces a steady,, fine spray. Water at low pres sure is deliv ered to the . The Bayley Turbo Air Washer Shov center of a ing Turbo Atomiser and Eliminator rapidly re volving cone-shaped rotor provided with atomizing pins set in its periphery. This atomizer requires very little attention, and will operate successfully under low water pressure. The orifices are large and this atomizer, unlike high pressure nozzles, cannot clog. Bayley Chinook Heating Sections: The Chinook sec tion is used with blast heating, venti lating and drying systems, and is suit able for high or low pressure steam cir culation. The base is divided into two chambers. Steam enters (see cut) the lower chamber, ris ing through 2^-in. pipes located within the 1^-in. pipes leading from the upper chamber. Condensation takes place in the larger pipes, the water falling into the upper chamber and draining away through the return outlet. The Chinook can be repaired in the middle of the bank without breaking steam connections or taking down a section. Shipped assembled in smaller sizes, and knocked down in the larger units. May be installed in horizontal or vertical position. Bayley Chinookfin Heating Sections: Are the same design as the Chinook Heaters, using heavy gauge copper fin tubes. As compared with Chinook it is much lighter and occupies less space. Bayley Plexfin Unit Heaters: This huit incorporat es Chinookfin radiation and Plexiform or Aeroplex fans. The fan assem bly including top plate and motor is re movable as a unit for main tenance and inspection. The heating element is a re movable unit. Casing all welded extra heavy gauge. This is an exceptionally high grade unit at a moderate price. 964 Air System Equipment Fans and sio^era Buffalo Forge Company 450 Broadway, Buffalo, N. Y. Branch Offices NY _________ 1303 Standard Bldg. Ga-------------------------;305 Techwood Drive Miami, Fla.--Southern Air Conditioning Corp.. 149 N. E 20th Terrace Me508 St. Paul St Minneapolis. Minn-------------------------------------------------------------------- 2102 Foshay Toro Riirnu Mass. Melrose Sta507 Mein St NASUvn.LK.TNNN.--SouthernSolesCo. 117 Kift.ii Ave., North ..............20 North Wacker Drive /NvriNNvn Ohio ....................- 626 Broadway Cle^lOT Ohio"!.................... --418 Rockefeller Bldg. Dalias*Texas......_................1801 Tower Petroleum Bldg. Newark27 Woshioston St, Room 203 New Orleans, La.--Devlin Bros-------1003 Maritime Bldg. New Yore, N. Y..................39 Cortlaodt Bldg,, Room1110 Omaha, Nebraska..------------ ------------- 660 North 18th St Davenport. Iowa--D. C. Murphy Co., 305 Security Bldg. Philadelphia, Pa--------------------------------- 702 Cunard Bldg. Denver. Colo.--Hendrie 4 Bolthoff Mfg. 4 Supply Co., u 1635 Seventeenth St Phtsburoh. Pa.--.....---------(1-------- i j Bjjj*- Richmond, Va.--Williamson & Wilmer, Inc., Mutual Bldg. Des Moines, Iowa--D. C. Murphy Co., 214 Old Colony Bldg. San Francisco, Cali?.--Moore Machinery Co., Detroit. MlcH.-Coon DeVimer Co.. ' ^' 2051 W. Lafayette Blvd. ,,T ,, Sr. Louis, Mo1598 Arcade Bldg. V"N" Greenville, S. C21 Blue Bldg. Seattle, Wash-------------------------------------------------- --------------------- 500 First Ave., South Houston Texas____ ________ ____________505 Rusk Bldg. kSSeneb, Ont., Canada-- Toledo. Ohio--------------------------- V oij922 Luiwood AveWashington, D. C.--640 Woodward^BWg Canadian Blower & Forge Co., Ltd. 15tb and H Sts., N.W. Knoxville, Tenn.--C. F.Sexton. .702 Empire Bldg. .Wilkes-Barre, Pa--Power Engineering Co Los Angeles, Calif.708 Pershing Square Bldg. 517 Brooks Bldg 'PRODUCTS: Heating and Ventilating Equipment including: Unit Heaters, Multiblade Fans, Pipe Coil Heaters, Buffalo Air Washers, Buffalo Unit Air Washers, Buffalo Unit Coolers, Drying Equipment, Mechanical Draft Fans, Air Preheaters, Exhaust Fans, Blowers, Dust Collectors, Disc Fans, Spray Nozzles. Buffalo Air Washers Buffalo Limit-Load Fans Buffalo Air Washers and Humidifiers are built for the most efficient washing, puri fying and tempering of air under varying atmospheric conditions. Designed and constructed for low cost installation and maintenance. Careful attention to struc tural details insures long service-ability with a minimum of attention. Several types and models to meet specific plant requirements. Fans for Every Ventilating Need Buffalo Fans represent over 60 years of specialization in the design and construc tion of fans for practically every venti lating and air-handling application from small kitchen fans to rugged fans for boiler draft. For complete information state the type of fan you are interested in and a catalog will be sent. Buffalo Limit-Load Fans for ventilating embody several improvements to deliver stepped-up efficiency under practical con ditions. Durably built for years of service. Dynamically balanced. Quiet, economical to operate. Non-overloading character istic prevents motor from overloading and burning out, regardless of fan load. Buf-flow Axial Flow Fans This specially de signed high pressure fan--with direct ional guide vanes-- propels the air stream in a true axial direction. Energy losses, are j reduced to a mini mum with a resulting increase in fan efficiency and marked power savings. What's more, this fan cannot overload and burn out the motor. (See also Page 1072) 965