Document O1mXr8N1Kge2ONpvzvb6z7xaK

-IK f$OM) TENNECOINTEROFFICE MEMO CHEMICALS, INC. to Route List from Carr Subject Testing Method 4-115 At AT Burlington d*te January 20, 1972 copy to Distribution List Attached Attached is Testing Method 4-115 entitled "Wet Screen Analysis, Blending Resins" which is to be placed in Section 4 of your Quality Control Manuals. Also attached is your revised Index for Section 4. This index supersedes the one dated December, 1970. please discard the obsolete copy and insert the revised one. Attachments (2). HBC/jt H.B. Carr COLORITE 016677 TENNECO INTERMEDIATES DIVISION TENNECO CHEMICALS, INC. INDEX SECTION 4 TITLE % Total Solids Content of Methocel Solutions Wet Pisheye Determination % Total Solids Determination of Centrifuge Effluent Determination of Contamination (Wet Slurry) Quantitative Analysis of Recovered Monomers Viscosity Measurement (Ford Cup) Ether Extract Filtration Time of Plastisol Latex Hot Plate Determination of $ TSC of DHW-80 Titration of 1755 and 0565 Latex Calibration of Pycnometer Refractive Index Measurement of Liquids Pressed Plaque Evaluation Filterabllity of Plastisol Latex (Filter Leaf Test) Evaluation of Methocel Solution for JJndissolved Methocel Wet Screen Analysis, Blending Resins METHOD NUMBER 4-100 4-101 4-102 4-103 4-104 4-105 4-106 4-107 4-108 4-109 4-110 4-111 4-112 4-113 4-114 4-115 Effective January, 1972 Supersedes Index Dated December, 1970 COLORXTE 016678 TENNECO INTERMEDIATES DIVISION TENNECO CHEMICALS, INC. QUALITY CONTROL TESTING METHOD DATE: January, 1972 METHOD NO.: 4-115 TITLE: Wet Screen Analysis, Blending Resins SCOPE: The quantitative determination of resin retained on a 200 mesh screen. APPARATUS: Torsion Balance U.S. Standard Screen, 200 mesh Oven, forced air CHEMICALS: Sample to be tested. Tap water. PROCEDURES: 1. To a tared 200 mesh screen add 50 grams of resin to be tested. 2. Place under running tap water and agitate with the fingers until the only sample remaining is that which cannot pass through the screen. 3- Place the wet screen in a forced air oven until dry. 4. Remove from oven and cool to room temperature. 5- Weigh on torsion'balance. The increase of weight recorded (a). CALCULATIONS: A x 2 = $ retained REPORT: Report to the nearest 0.1$. Written by: E.L. Kanyok Issued by: H.B. Carr Supervisor - Quality Control COLORITE 016679