Document O1jqek0ggJqr5knN4Rn8pbzbv
TABLE NO. 1
RESPIRATOR (CANISTER TYPE)
GAS
TYPE OF CANISTER
COLOUR MARKING OF CANISTER
Acetone Acridine Acrolein I Ammonia 1 Aniline
i Benzine (Petroleum Vapours) I Benzole 1 Bromine I Butane
Butene 1 ) Butene 11 )
Carbon Tetrachloride Chlorine j Ether * Ethane ' Ethyl Chloride j Ethylene Ethylene Oxide Hydrobromic Acid Hydrochloric Acid Hydrocyanic Acid Hydrofluoric' Acid
Isobutene Isobutylene Methanol Methyl Alchohol Methyl Bromide Methyl Chloride Nitrous Fumes Phenol Phosgene . Propane Propylene Pyridine
Sulphur Dioxide Sulphur Trioxide Sulphuretted Hydrogen Sulphuric Acid Sulphuryl Chloride Toluene Trichlorethylene Thionyl Chloride Xylene
*
--1 1 H, *--4
C
c.c.
C.C. A.
c c.c. c.c.
C. G.
Nil Nil
c.c.
C,G. C
Nil
ms*-
Nil
c
G.G.C. C.G.C
D
C.G.
Nil
Nil C C
Nil 0
N.F. C.C. C.G. Nil Nil
C
S.H.C.
C G.C S.H.
CG.C. C. G.C.
C.C. C
C.G.C. 0
Black
Black with vertical grey stripe. .
Black with vertical grey stripe.
Blue
Black
Black wit-h vertical grey stripe.
Black with vertical grey stripe.
Red Nil
Nil
Nil Black with vertical grey stripe.
Red
Black
Nil HSe L
Nil
.
Black
Red xhLth vertical grey stripe.
Red with vertical grey stripe.
White.
Red
Nil
Nil Black
Black
Nil
Black with vertical orange stripe.
Orange
Black with vertical grey stripe.
Red
Nil Nil
Black
Red with white and grey stripes
Red with vertical grey stripe.
Red -with white band
Red with vertical grey stripe.
Red with vertical grey stripe.
Black with vertical grey stripe.
Black
Red with vertical grey stripe.
Black with vertical orange stripe.
} ! | i
i
! J j
1 | \
ASSOCIATED ETHYL COMPANY LIMITED
NORTH WICH, CHESHIRE
COPY
rpATSTiP ;Tn
HARMFUL
Bauxite Bleaching Powder
Genent Iron Oxide line, quick Line, slaked Plaster Sand Soda Ash Stone Sulonur
HUISAHCE
Goal Flock Flour Grain Dust Salt (Ccanon) Wood Fullers Barth
KE 00156SQ
*0o st- COMPANY LIMITED Aloe
COPYH. FOSSETT
C. H. NOBIS
MORTHW1CH, CHESHIRE
SBG/2
25th. April 1951
B. 3,1, COMMITTEE - GAS MASKS, ETC,
I attended idle 2nd Committee Meeting of the British Standards Institution Technical Gomadtee HSS/15 yesterday afternoon. You will doubtless hare the Agenda for this meeting onyour files, but the main item for discussion was to consider the preliminary draft of the proposed standard for respirators and breathing aparatus for use in the Petroleum and allied industries.
In the minutes of the first meeting of the 22nd May1950, Mr. Kelley undertook to submit recommendations for suitable breathing aparatus for use in connection with the handling of tetraethyl lead and "Etbyltt Fluid. I do not know whether you have formally submitted the views of the Company on this matter, 1 myself, as you will appreciate, am representing the Institute of Petroleum, on the Committee, and therefore enforced to have an objective rather than a subjective view of the proceedings.
During the course of discussions, I said that tetra ethyl lead was a vapour hazard that was cemonly met with in the petroleum industry, but it was not included specific ally in the list of gases given in Table I and Table II of the proposed draft standard.
' The answer given on this point was that there was no type of canister that had been *approvedB for against this particular substance -- in other words, it was not a gas that was covered under any statutory requirement, or either under the Factory Act or Chemical Works Regulations.
All the canisters listed as approved had, in fact, been
approved by the Factories Branch of the Ministry of Labour
(formerly the Home Office), presumably at Porten after having
been tested. I think it vpould be a pity if the B.3.I, were
to issue this standard for the Petroleum, Industry, and then
for somebody in the industry to pick it up to look for the
type of breathing aparatus and/or canister that should be used
for tetraethyl lead, and not find it listed. As far as/...
KE 0015681
N19623.01
;
.'VS*-: ; -
'ME a s s o c ia
e t h y l c o mp a n y 'l imit e d
C* H* Uobl
2
CO PY
NORTH WICH. CHESHIRE
25th %rll 1951
As far as X can see, there are two possible courses open J (i) for the Company to submit its view on the subject and to ask the B.S.I. if they would he prepared to make a recommendation on this point or, (ii) for us to have the Factories Branch of the Ministry of Labour approve a canister for use specifically against T.B.L.
As I intimated at the beginning of this note, I m really stepping outside my tents of reference as an objective observer, although I did raise the point, very generally, from the angle of the Oil Industry. % personal feeling is that it might be a desirable thing for the Company to state its views* Incidentally, there was a young Army Officer there who had just been co-opted on to the Committee, those interest seemed to lie in the T.E.L, field, and he seemed to have an extremely loose appreciation of the problems.
Just as one last thought, I believe there is a bureau cratic or administrative, difficulty in asking the Factories Branch of the Ministry of Labour to approve a canister for T.E.L,, since the use of canister respirators for this application, at oil refineries or installations, is outside the formal jurisdiction of the Chemical yorks Regulations, As far as I believe, the Petroleum Act certainly does not cover the position - in fact, this Act was, X think, largely formulated to cover the distributive petroleum industry in the very early days before refining was undertaken in the United Kingdom. I think it might be of value if you were to have a general discussion with H. C9 Stephenson of the Factories Branch of the Ministry of Labour, who, as you may know, is located at Artillery Souse.
hf/ecd
HE 0015682
H, FQSSETT