Document O1jqek0ggJqr5knN4Rn8pbzbv

DownloadRandom document
TABLE NO. 1 RESPIRATOR (CANISTER TYPE) GAS TYPE OF CANISTER COLOUR MARKING OF CANISTER Acetone Acridine Acrolein I Ammonia 1 Aniline i Benzine (Petroleum Vapours) I Benzole 1 Bromine I Butane Butene 1 ) Butene 11 ) Carbon Tetrachloride Chlorine j Ether * Ethane ' Ethyl Chloride j Ethylene Ethylene Oxide Hydrobromic Acid Hydrochloric Acid Hydrocyanic Acid Hydrofluoric' Acid Isobutene Isobutylene Methanol Methyl Alchohol Methyl Bromide Methyl Chloride Nitrous Fumes Phenol Phosgene . Propane Propylene Pyridine Sulphur Dioxide Sulphur Trioxide Sulphuretted Hydrogen Sulphuric Acid Sulphuryl Chloride Toluene Trichlorethylene Thionyl Chloride Xylene * --1 1 H, *--4 C c.c. C.C. A. c c.c. c.c. C. G. Nil Nil c.c. C,G. C Nil ms*- Nil c G.G.C. C.G.C D C.G. Nil Nil C C Nil 0 N.F. C.C. C.G. Nil Nil C S.H.C. C G.C S.H. CG.C. C. G.C. C.C. C C.G.C. 0 Black Black with vertical grey stripe. . Black with vertical grey stripe. Blue Black Black wit-h vertical grey stripe. Black with vertical grey stripe. Red Nil Nil Nil Black with vertical grey stripe. Red Black Nil HSe L Nil . Black Red xhLth vertical grey stripe. Red with vertical grey stripe. White. Red Nil Nil Black Black Nil Black with vertical orange stripe. Orange Black with vertical grey stripe. Red Nil Nil Black Red with white and grey stripes Red with vertical grey stripe. Red -with white band Red with vertical grey stripe. Red with vertical grey stripe. Black with vertical grey stripe. Black Red with vertical grey stripe. Black with vertical orange stripe. } ! | i i ! J j 1 | \ ASSOCIATED ETHYL COMPANY LIMITED NORTH WICH, CHESHIRE COPY rpATSTiP ;Tn HARMFUL Bauxite Bleaching Powder Genent Iron Oxide line, quick Line, slaked Plaster Sand Soda Ash Stone Sulonur HUISAHCE Goal Flock Flour Grain Dust Salt (Ccanon) Wood Fullers Barth KE 00156SQ *0o st- COMPANY LIMITED Aloe COPYH. FOSSETT C. H. NOBIS MORTHW1CH, CHESHIRE SBG/2 25th. April 1951 B. 3,1, COMMITTEE - GAS MASKS, ETC, I attended idle 2nd Committee Meeting of the British Standards Institution Technical Gomadtee HSS/15 yesterday afternoon. You will doubtless hare the Agenda for this meeting onyour files, but the main item for discussion was to consider the preliminary draft of the proposed standard for respirators and breathing aparatus for use in the Petroleum and allied industries. In the minutes of the first meeting of the 22nd May1950, Mr. Kelley undertook to submit recommendations for suitable breathing aparatus for use in connection with the handling of tetraethyl lead and "Etbyltt Fluid. I do not know whether you have formally submitted the views of the Company on this matter, 1 myself, as you will appreciate, am representing the Institute of Petroleum, on the Committee, and therefore enforced to have an objective rather than a subjective view of the proceedings. During the course of discussions, I said that tetra ethyl lead was a vapour hazard that was cemonly met with in the petroleum industry, but it was not included specific ally in the list of gases given in Table I and Table II of the proposed draft standard. ' The answer given on this point was that there was no type of canister that had been *approvedB for against this particular substance -- in other words, it was not a gas that was covered under any statutory requirement, or either under the Factory Act or Chemical Works Regulations. All the canisters listed as approved had, in fact, been approved by the Factories Branch of the Ministry of Labour (formerly the Home Office), presumably at Porten after having been tested. I think it vpould be a pity if the B.3.I, were to issue this standard for the Petroleum, Industry, and then for somebody in the industry to pick it up to look for the type of breathing aparatus and/or canister that should be used for tetraethyl lead, and not find it listed. As far as/... KE 0015681 N19623.01 ; .'VS*-: ; - 'ME a s s o c ia e t h y l c o mp a n y 'l imit e d C* H* Uobl 2 CO PY NORTH WICH. CHESHIRE 25th %rll 1951 As far as X can see, there are two possible courses open J (i) for the Company to submit its view on the subject and to ask the B.S.I. if they would he prepared to make a recommendation on this point or, (ii) for us to have the Factories Branch of the Ministry of Labour approve a canister for use specifically against T.B.L. As I intimated at the beginning of this note, I m really stepping outside my tents of reference as an objective observer, although I did raise the point, very generally, from the angle of the Oil Industry. % personal feeling is that it might be a desirable thing for the Company to state its views* Incidentally, there was a young Army Officer there who had just been co-opted on to the Committee, those interest seemed to lie in the T.E.L, field, and he seemed to have an extremely loose appreciation of the problems. Just as one last thought, I believe there is a bureau cratic or administrative, difficulty in asking the Factories Branch of the Ministry of Labour to approve a canister for T.E.L,, since the use of canister respirators for this application, at oil refineries or installations, is outside the formal jurisdiction of the Chemical yorks Regulations, As far as I believe, the Petroleum Act certainly does not cover the position - in fact, this Act was, X think, largely formulated to cover the distributive petroleum industry in the very early days before refining was undertaken in the United Kingdom. I think it might be of value if you were to have a general discussion with H. C9 Stephenson of the Factories Branch of the Ministry of Labour, who, as you may know, is located at Artillery Souse. hf/ecd HE 0015682 H, FQSSETT