Document O1gmVqvX4rkMyQG4VgeJvnqBK
FILE NAME Quebec Asbestos Mining Association QAMA
DATE 1935 June 3
DOC QAMA100
DOCUMENT DESCRIPTION Internal Report by D. Wolochow RE Investigation of Asbestos
. 4
7
s 3
.
AUTHOR D. WOLOCHOW
INVESTIGATION ASBESTOS
PROGRESS KERVNI
DIVISION
CHEMISTRY CHEMISTRY
PERIOD COVERED Kay 19
ewan ee abs 6m
ne OEE es CONT ED + FACC a T h SED
DATEJune 1936
Date Typed 23 June 193
TOPICS .
2
3
Utilization of Short Fibre Asbestos Fibre for Filtration Standard Testing Procedure
Purposes
5 Tests on Asphalt Floor Tile 6 Visitors to the Laboratory
1. Utilization of Short Fibre
a
It has been found that if the light material is separated
from short fibre 7 R and is then mixed with portland cement
the product obtained is considerably lighter in weight then when
the whole fibre is used Thus with equal weights of this light
fraction and portland cement the product weighs about 40 cu.ft
and has considerable strength Because of the low density this
product should also have low thermal conductivity
purposes
prepared Using fibre such as has been
a product of very low density was
for filtration
obtained - 17 cu.ft
and the colour is light cream
b
report figures
The pressure molded specimens mentioned in the previous No. C47-38 p.2 par.f have been broken and the following are representative of the results obtained
Fibre No. 646 - 1 part Portland Cement 1 part
Tensile Strength
No water added
1125 lbs in
7.5 water edded
15 water added
1225
9
"
"
1340
Comp
Strength
Density
15,375 lbs
90. in
19,875 1887
BQ in
19,000 lbs
60. in
227 gus or
142 lbs cu.ft
2.40 gms OI
150cu.ft
2.27 gms ccc
142 cu.ft
The specimens pleasing appearance and
purposes
which were molded with water had a very
should be suitable for decorative building
COPY FOR THE PRESIDENT
J.
M. PLAINTIFF'S EXHIBIT
Bayone 962
2
Asbestos Fibre for Filtration Purposes
a
Tests have been made on opening of fibre with
rode in place of pebbles in small pebble mill also with hard
rubber balls in place of the pebbles It was found that the
rods did not cut the fibre as much as pebbles do but on the
other hand the opening efficiencways somewhat lower
study is warranted
Further
The
fibre at all
with a rubber
hard rubber balls did not of course damage the but the efficiency was very low A metal ball
covering would perhaps give interesting results
The possibility of using the J. M. opener for opening fibre for filtration purposes has been investigated but the results indicated that this type of machine would not be satisfactory Seven passes through the opener left the fibre
with a large number of pencils and did not redeqse the magnetit
to nearly the same degres as the pebble mill does
was
for
b
At the request of Mr. W. A. Newall a conference
attendeadt Toronto regarding the proposed arrangements
the production of filtration asbestos on a commerdta
scale After a lengthy discussion of the various terms of the
agreement it was suggested to Mr. Hewall that he write a letter
to the Council listing items on which he wished to obtain
more official information items he wished amended deleted
or added
3
Standing Testing Procedure
procedure
Work on the development of a standard testing
procedure for the q S. test has been continued In report
No. C 67-383 prepared by A. van Winsen a tentative procedure
consisting of cake opener - press - cake opener is suggested
but tests which have been made indicate that the problem has
not been entirely solved as variations in test were still
obtained
4
Q. A. P. A. Meeting
The regular meeting of the Association held on 23 May 1938 at Sherbrooke was attended
Report No. C61-388 ( see above ) was presented
and discussed It was decided that the Canadian Mansville Company would build a cake opener such as was designed here and would put it at the disposal of the Technical Committes
sae
~
one
ae Re Oe
eam nee eae
ne
The chairman of the Fibre Inspection Committee brought
up
the
the Council's
request for
a
certified
statement
regarding
the performance of the metal machine After much discussion
he was authorized to issue such a certificate
Dr. Stephenson ( C.J.M.medical C.J.M.medical officer was present
and a round table discussion of asbestosis took place The
application of
the proposed provincial
legislation on this
hazard was discussed by Mr. Robertson safety service agent
For the association 59 & summary of the complete discussion
is to be circulated with the minutes of the meeting it will
not be dealt with here
5
Tests on Asphalt Floor Tile
- See report No. C 57-38S dated 12 May 1938
60
Visitors to the Laboratory
Professor J. W. Bell of McGill University spent
half a day in the laboratory inspecting the equipment and
discussing the work which is being done
.
fica
JJA