Document O1LYM2Xg8Y29J5xgDe64VnGZL

Dow U.S.A The Dow Chemical Company P 0, Box 150 PlaQuemme. Louisiana 70765-0150 September 9, 1992 Daniel Cortez Eddie Guillory Petrin Petrin Building 4106 cc: Rock Gustin LHC II Building 4801 PRODUCED FOR THE ASBESTOS DATABASE PATE: MASTER No. l Asbestos Monitoring Enclosed are sample results for potential exposure to asbestos. The OSHA 8-hour permissible exposure limit for asbestos is 0.2 f/cc >5 microns and the 30-minute short term exposure limit is 1 f/cc >5 microns. The results displayed are based on sampling duration. The data sheet shows the results of exposure using two methods, the Limit of Detection (LOD) and the Limit of Quantitation (LOQ). Included on the data sheet is an explanation of the method Limit of Quantitation. Thank you, Darlene S. Creel Industrial Hygiene Ext. 6181 Building 3502-E Attachment dsc DO A 114048 CONFIDENTIAL LOUISIANA^DiyiSION INDUSTRIAL HYGIENE SAMPLE RECORD SAMPLE |\|o 1 5 44 2 PLANT/DEPT uf4l Jt__________________________ DATE f -I ? ~ MONITORING FOR:_______ C.'bf>_______________________________________ ^_______ OTHER CHEMICALS PRESENT._,,------------------- _-------------------------------------- - TEMPDEGREE F -HUMIDITY SAMPLE COLLECTION MEDIA BADGE NO TYPE 3 CHARCOAL TUBE 9-FILTER CASSETTE SILICA TUBE DRAGER TUBE 3 OTHER __________ SIZE________________ SIZE SIZE________________ TYPE_______________ shift. 3-Thr. ft ,, cKpersonnel sample area sample 3 FULL SHIFT TWA 3 STEL/TASK -----------WIND DIRECTION employeenamf EMPLOYEEI.D # ' /<! JOB CLASSIFICATION irSv IH JOB CODE# -- CONTRACTOR COMPANY (r T, noAS RESPIRATOR USED' CTYES 3 NO J RESPIRATOR MODEL / CANISTER TYPE A/vr-ft. I/OO 14 wlfr&A MOUTH-BIT DUST 0" HALF-FACE FULL-FACE 3 AIR-LINE O SCBA DESCRIPTION OF AREA SAMPLED/JOB PERFORMED DURING MONITORING . (LMf7vZ%hJ2- PUMP SERIAL no CALIBRATION DEVICE^ _________ ObUBBLEMETER 3 ROTAMETER 3 OTHER _____________________________ PUMP FLOW RATE CALIB BEGIN 1._ 2_ 3._ r/U_ drdr BEGINNING FLOW RATE AVG. ( ENDING I 2-HsJ Z. 3 JWUE/ ENDING FLOW RATE AVG. >Sl/"^~ 3<TfO 3"CC/MIN 3 l/min szYj'O 3^C/MIN 3 L/MIN SAMPLE AVERAGE FLOW RATE TIME STARTED I/O. 00 TIME STOPPED tO/'M TOT RUNNING TIMEIMIN1 __________ _________ SAMPLE VOLUME (AVG FLOW X RUN TIME) v 3".A/' - analytical report reference # ANALYTICAL RESULTS __________ MlO RESTRICTED FOR USE WITHIN DOW ONLY * , O.OI tQb VfM24 48 FORM FILLED IN BY:. LOUISIANA DIVISION INDUSTRIAL HYGIENE SAMPLE RECORD PLANT/DEPT _ LH-c. xT MONITORING FOR: /f-5 UnJaS F*. fa*/- s DATE ?- ></-*?>OTHER CHEMICALS PRESENT SAMPLE No 15437 TEMP DEGREE F HUMIDITY , SAMPLE COLLECTION MEDIA 3 BADGE NO,____ TYPE. 3 CHARCOAL TUBE SIZE. 3-FILTER CASSETTE SIZE. jjJCjajyL. 3 SILICA TUBE SIZE. 3 DRAGERTUBE TYPE. 3 OTHER ___________ SHIFT 3'8'hr 3 12 HR O' PERSONNEL SAMPLE 3 FULL SHIFT TWA STEL/TASK 3 AREA SAMPLE __ WIND DIRECTION EMPLOYEE NAME. EMPLOYEE I.D.# JOB CLASSIFICATION. IH JOB CODE # CONTRACTOR COMPANY. 'P-'+r.y Cvrp RESPIRATOR USED' 3"?ES 3 NO RESPIRATOR MODEL / CANISTER TYPE filer At 11 OO Uu/ltpa 3 MOUTH-BIT 3 DUSTr 3--TI3RAAILFC-F.AECEATCf 3 full-face 3 air-line 3 SCBA DESCRIPTION OF AREA SAMPLED/JOB PERFORMED DURING MONITORING PUMP SERIAL NO. j~l > ' CALIBRATION DEVICE CTBUBBLEMETER 3 ROTAMETER 3 OTHER______________________________ PUMP FLOW RATE CALIBRATION: BEGIN 1 2. 3 ?rTT BEGINNING FLOW PATE AVG. J 5~i <4 FNDING.1. 2 ?y,:?..... .. ?rvy "CC/MIN 3 L/MIN [ENDING FLOW RATE AVG.. 3TYL3_ 3^CC/MIN 3 L/MIN SAMPU AVERAGE FLOW RATE Z^iuSi TIME STARTED, :h*\ TIME STOPPED. .2 o.'-L'tn TOT. RUNNING TIME(MIN). 'S~u>7TwT~ SAMPLE VOLUME (AVG FLOW X RUN TIME). - Ua^S- ANALYTICAL REPORT REFERENCE # AttdSQl*. ANALYTICAL RESULTS: Z-Hqp '<0-0/ "~n5b * RESTRICTED FOR USE WITHIN DOW ONLY * VP 124 5L FORM FILLED IN BY. J? A 1 14849 nfto fnttai. ASBESTOS MONITORING DATA RESULTS: LHC H 1992 **LOD ***LOQ EXPOSURE GUIDELINES 8-HR. TWA LIMIT - 0.20 FIB/CC 30-MINUTE LIMIT = 1.0 FIB/CC LIMIT OF DETECTION = 7 FIB/MM2 LIMIT OF QUANTITATION = 100 FIB/MM2 DATE SAMPLE# PERSONNEL DESCRIPTION 8/13/92 15442 *433-19-6528 Insulator: Removing insulation from 3' line - WET METHOD USED 8/14/92 15437 *437-60-8864 Insulator: Removing insulation from 3" line - WET METHOD USED DUR(MIN) VQL(L) 30 74 30 75 LOD FIB/CC 0.01 <0.01 ***LOQ FIB/CC <0.52 <0.51 * The proper protective Nothing was worn during the job. North 7700 Respirator with HEPA filters were worn during the job. Note: The Limit ol Quantitation has been defined as 100 Fibers/MM2 using the minimum fiber loading criteria specified. In the NIOSH analytical method 7400, the stated range of the method is 100 to 1300 Fibers/MM2 filter area. Although samples below this range can be analyzed, the method has not been validated below 100 Fibers/MM2. However, the NIOSH method 7400 also establishes the estimated Limit of Detection as 7 Fibers/MM2 (Reference OSHA Std. 1910.1001, Appendix B). Based on this information, we will establish 100 Fibers/MM2 filter area as our Limit of Quantitation and 7 Fibers/MM2 filter area as our Limit of Detection (which is more representative of the actual fibers present) for asbestos monitoring. We will report both Limit of Quantitation and Limit of Detection. If only Limit of Quantitation were expressed, the minimum reportable result would calculate to be 0.04 Fibers per cc for an S-hr. Time weighted average sample at a flow rate of 2 liters per minute and 0.6 fibers per cc for a 30 minute time weighted average short term sample at a flow rate of 2 liters per minute. DOW CONFIDENTIAL i j O 14 (j (j CONrTDFNTTAi