Document O1Kj0JoGGyyY920OV408ko6RX
394
CHAPTER 35
1952 Guide And Data Boole
Plate Cooler {la section)
Number of plates Heat transfer surface per plate Heat transfer surface in 1st section Number of passes Number of streams per pass Water Sow rate Wort flow rate
Plate Coder (2nd section)
Number of plates Heat transfer surface per plate Heat transfer surface in 2nd section Number of passes Number of streams per pass Chilled water flow rate
40 4.3 sq ft 172 sq ft 5 4 34,000 Ib/hr 17,000 tb/hr
24 4.3 sq ft
103 sq ft 3 4
52,000 Ib/hr
Fermenting Cellar
After cooling, the wort is pitched with yeast and collected in a fermenting tank, where fermentation sets in according to the chemical reaction previously outlined. For each 31-gal bbl of wort, about 25 lb of solids are converted. The daily rate of con version varies, depending on the operating procedure adopted
in each plant. A representative rate might be, on the first day, 2 lb of maltose converted. The rise in temperature caused by fermentation increases this rate to 7 lb on the second day. By now the maximum desired temperature has been attained and a further rise is checked by means of an attemperstor, so that on the third day another seven pounds is converted. This rate continues on through the fourth day. By now the amount of unconverted maltose remaining in the beer is greatly dimin ished, and because of the inhibiting action of alcohol and car bon dioxide on further yeast propagation, the action nearly halts on the fifth day when only about 3 lb are converted. Be cause of the decreased rate, the temperature of the beer begins to drop and by the sixth day further fermentation has been checked. It is then cooled to 29 F, filtered and transferred to the stock cellar. Complete fermentation can generally be ef fected in about 7 days.
Attemperatora usually consist of one or two rings of 4 in. copper tubing, concentric with the walls of the tank and supported at about two-thirds of the height of the liquid. The agitation necessary for beat exchange between the attempe* rator and the beer is provided partly by convection, but prin cipally by the ebullition set up by the CO* bubbles rising to the surface of the liquid. In estimating the heat transfer surface re quired, a heat transfer rate of 15 Btu per fsq ft) (hr) (F deg) has been found to be reasonable. The heat loss from tank walls and surface of the liquid may be disregarded in calculating the* attemperstor coil surface requirements. However, if the room temperature is allowed to drop appreciably below 50 F, the heat dissipated through metal tank walls becomes important, and depending on the degree of heat dissipation, fermentation may be retarded or even inhibited. In such instances, wooden fermenting tanks or the insulation of the tank walls and bottoms are indicated so that the control of heat removal re mains in the sttemperator.
The refrigeration requirements are necessarily based on the maximum volume of wort in fermentation at one time. Fig. 2 illustrates this load based on a 500 bbl per day production rate. The dayB are represented by the abscissa, and the pounds of solids converted per day by the ordinate. The in dividual brews in fermentation on any particular day are additive. For example, on the fifth day Brew No. 1 is finishing with a conversion rate of 3 lb for that day; Brew No. 5, which is just beginning the fermentation cycle is fermenting at the rate of 2 lb; while Brews No. 2, 3, *nH 4 are at the maximum rate of 7 lb per bbl per day each. The total solids fermented on this day is thus seen to be 26 fl) per bbl for the 2500 bbl in fermentation, making a total of 13,000 lb of solids converted.
6r*w 2 Br*w 3 6>*w 4 Bntw I
7&X500 bbt-SSOO tb 7 O.XSOO btf-3SOO tb 7IBX500 bbl=3500 lb 3 ftX500 bW= 1500 lb
261b
ISfiOOtb
Fig. 2 .... Solids Conversion Rote
Since the heat of fermentation is 280 Btu per lb, the refrigera tion load would be:
13,000X280 24X12,000
12.6 tons
Calculations for axing of attemperators must take into con
sideration tile following:
1. The internal dimensions of the fermenting capacity.
and its
2. The temperature difference between the coolant and the fermenting beer.
3. The maximum daily sugar conversion rate.
4. The heat evolved, which is at the rate of 280 Btu per lb of fermentable sugar converted.
Assuming a square fermenting tank 13 ft sq to hold a brew of 500 bbl, and allowing 1 ft between the tank wall and the attemperator for easy cleaning, an 11 ft square sttemperator can be used, giving 44 perimetrical feet of tubing.
From Ftg. 2, the maximum daily conversion rate is shown to be 7 lb per barrel. Calculating for 500 bbla, at 280 Btu per lb of sugar converted, . .
7 X 500 X 280 - 980,000 Btu per day or 40,833 Btu per hr.
Then assuming a 50 F fermenting beer temperature and 20 F brine, a temperature difference of 30 F deg, sM a heat transfer rate of 15 Btu per (hr) (sq ft) (F deg) for the attem perstor, the number of sq ft of surface required would be:
40,833 15 X 30
90.7 sq ft
Considering 4 in. OD tubing which has an external area of 1.05 sq ft per ft, the number of lineal feet required would be:
90.7/1.05 86.4ft
Therefore, two attemperatora, each 11 ft square, would give '88 ft of tubing, which is adequate for the conditions outlined.
About 13 lb of CO* are generated for each barrel of beer fer mented, most of which is collected and liquefied for later use in the brewery for carbonating, for counter pressure in transfer operations, and for the bottling lines.
Beverage Processes
395
Adequate fresh air must be provided in open tank ferment ing to safely dilute the CO* emanating from the fer menters. The amount permissible should be such that there is no health hazard to the men working in these spaces. Concen trations below one percent are considered entirely safe. In creasing amounts reduce the efficiency of the worker and con centrations of four percent make the performance of work for protracted periods untenable. Since it is heavier than air, CO* tends to settle to the floor from where it may be withdrawn by mrans of scupper connections at the floor level. Fresh air may be introduced through the ceiling, the openings being located so as not to remove or disturb the layer of protective CO* gas on top of the fermenting beer.
Stock Cellar
The stock cellar is a refrigerated room containing tanks into which the cooled beer from the fermenter is transferred for the purpose of aging and settling. New filtering methods have ob viated the need for settling, as all suspended solids are re moved during the transfer from the fermenter. The retention of beer in the stock cellar is a matter of the brewer's discretion and may be from 3 weeks to 3 months.
While the CO* pollution of the air in the stock cellar is far less than in the fermenting room, adequate provision must be mnA* to supply fresh air in sufficient amounts to keep the con centration below 1 percent
Finishing Cellar
In the finishing cellar the beer is polished by filtration, and is then carbonated by any of a number of different methods. The filtering is usually done through a series of cellulose pulp filters, the number of filters used depending on the brilliance desired in the finished product. After this final processing, it is transferred to the racking room for filling into kegs, or to the government cellar for bottling.
Kraeusen Cellar
Instead of the usual carbonating method, some brewers pre
fer to carbonate by means of the Kraeusen method, for which
a Kraeusen cellar is substituted for the finishing cellar. This
cellar contains a number of
capable of retaining a pres
sure of about 20 psig. Because the retention period is from
7 to 14 days, a greater capacity is required here than in
the case of a finishing cellar. In transferring beer from the
stock cellar, it is blended with about 20 percent of beer that
had been brewed only a few days prior and which is just com
ing to the Kraeusen stage of fermentation. It is introduced
into a closed pressure tank and as fermentation is established
the evolved CO* gradually raises the pressure within the
vessel. More and more CO* is retained in solution as the pres
sure increases, the retention of gas being a direct function of
pressure and an inverse function of temperature. At a specified
pressure the excess is relieved by means of a closely regulated
relief valve, the pressure being such that the desired amount
of CO* is dissolved in the beer.
Heat is generated by this secondary fermentation, but the
temperature of the liquid does not rise to as high a tempera
ture as it did in the fermenter because the fermentable sugars
are only available from the 20 percent which has been added
as Kraeusen. Furthermore, the bulk of the liquid had a lower
starting temperature, having come from the stock cellar at
about 29 F. A temperature of from 42 to 44 F may be reached
at the peak, after which the liquid cools to the ambient tem
perature of the room. Tins cooling can be accelerated in the
tanks by means of attemperatora through which a brine such
as propylene glycol is circulated. Since additional heat is
generated, the calculations for the refrigeration required in
clude that of lowering the liquid temperature from 44 to 29 F
and maintaining
temperature for several days to coagu
late any chill-hazing proteins that may have been introduced
in the Kraeusen. These coagulated proteins are retained in the
filter when the beer is finally transferred to the racking ma
chine or to the government cellar.
Hop Storage
STORAGE
Hops should be stored at a temperature of from 29 to 32 F with a relative humidity of 50 to 60 percent and with very little air motion, to prevent excessive drying. Sweating of the
should not be permitted, as this would carry off the light aromatic esters which would deteriorate the fine hop char acter.
Yeast Culture Room
In the yeast culture room, yeast is propagated to be used in re-seeding and replacing yeast that has lost its virility. A rela tive humidity of 80 percent is required to prevent the yeast from hardening on the vat walls. The CO* blanket on top of the vats should not be disturbed by excessive air motion.
CO* Collection
Carbon dioxide gas produced as a by-product of fermenta tion is collected in closed fermenters, compressed and stored in pressure rankn for later use, when it is used for final carbonation, counter-pressure in storage and finishing tanka, transfer and in bottling and inning of the product. In the past the CO* was stored in the gaseous state at about 250 psig. However, more recently, practice in most of the medium and large breweries is to collect tile gas, and after thorough wash ing and purification it is liquefied and stored as liquid. Car bonic acid gas stored in the liquid state occupies about l/ of the volume of an equal weight of gas at the same pressure at room temperature.
It has been shown that from each barrel of wort fermented, about 13 lb of CO* is generated over a period of 5 days, though not at a constant daily rate. Brews must therefore be sched uled as nearly as possible to provide the gas as required for production; to balance the supply of gas with demand, stor age must be provided.
Of the 13 lb per bbl of gas generated, about 6 lb is collected, the gas at the beginning and at the end of the fermentation cycle not bong suitable is discarded because of excessive air content and other impurities.
From the fermenting tank, the gas is piped through a foam trap to a gas pressure booster. A water-column safety relief tank protects the fermenting tanks from excessive gas pressure and the surplus gas is here discharged to the outside. The booster raises the pressure from 1 psig to 5 to 6 psig to com pensate for friction head kiss in the long lines to the com pressor and to increase its capacity. A compressor of the twostage type with water injection to remove the heat of compres sion increases the presure to 250 psig. The entrained injec tion water is separated from the compressed gas by means of a knock-out tank and is usually collected, cooled and reinjected. The compressed gas is then deodorized.
CO* Liquefaction
From tables of the properties of CO*, the condensing tem peratures at several pressures are:
-20 F --14 F - 8F
200.35 psig 225.14 psig 251.96 psig