Document O1JK4mV0L08D1kkdNDvjgyVgp

f WEDNESDAY,' FEBRUARY. 2, 1077 PART VI ' ENVIRONMENTAL PROTECTION AGENCY POLYCHLORINATED BIPHENYLS (PCBs) 307.i Toxic Pollutant Effluent Standards DSW 380933 STLCOPCB4097551 6532 RULES AND REGULATIONS Title 40--Protection of Environment CHAPTER I--ENVIRONMENTAL ; PROTECTION AGENCY ' [PUL 67ft-7J PART 129--TOXIC POLLUTANT . EFFLUENT STANDARDS Standards for Polychlorinated Biphenyls (PCBs); Final Decision This Is a rulemaking proceeding under section 307(a) of the Federal Water Pol lution Control Act, as amended (the Act), 33 U.S.C. 1251 et seq. On July 23, 1976, the Environmental Protection Agency published proposed toxic pollutant effluent standards for polychlorinated biphenyls (PCBs) in the Federal Register, 41 FR 30468 et seq. Pursuant to the requirements of section 307(a) of the Act, a formal rulemaking hearing was commenced on the proposed standards on August 20, 1976 and, after 21 days of hearings, was concluded on November 30, 1976. " The proposed toxic pollutant effluent standards for PCBs published in the Federal Register on July 23, 1976 in cluded a prohibition on discharge of PCBs by any PCB manufacturer and stringent limitations on discharges by manufacturers of transformers and ca pacitors. Pursuant to section 307(a) (2) of the Act, based upon a preponderance of evidence in the record before me, I have determined that a prohibition on discharged PCBs shpuldlbc established ror translormer and capacitor manufac- xuilei's as weelli 3 maiiufaclurei's, section 307(a) (4) he /tf.t. The regulations establishing le prohibition are modified to provide for an adjustment of the prohibition in appropriate circumstances to take into account the presence of PORs" in a dis charger's intake wafer. ' Because due and timely execution of my functions imperatively and unavoid ably so requires, I have determined in accordance with 40 CFR 104.14(c) that the preparation and filing of a tentative decision and related procedures pur-* suant to 40 CFR 104.14Kb) should be omitted. 1. Background A. PARTIES AND PUBLIC PARTICIPATION IN RULEMAKING Objections to the proposed standards were received from the following, who were made parties to the proceedings in accordance with 40 CFR 104.3(a): The PCB Ad Hoc Committee ol the Elec tronics Industries Association Natural Resources Defense Council, Inc. Environmental Defense Fund American Paper Institute New York State Department of Environ mental Conservation Westlnghouse Electric Corporation In addition, in accordance with 40 CFR 104.3(b), written comments were received by the hearing clerk from the following Interested persons and were made part of the record: . General Motors Corp. Dow Chemical, USA F. R. Mallory and Co. Inc. Corncll-Dublller Electric Corp. State of California Water Resources Control Board Acrovox Industries, Inc. Department of Public Service of the City of Akron, Ohio Department of Natural Resources, Environ mental Protection Division of the State of Georgia Houston Research, Inc. Westgate Research Corp. General Electric Co. National Council of the Paper Industry for Air and Stream Improvement, Inc. Ford Motor Co. A summary of the principal comments and the Agency's response thereto are set forth below. B. DEVELOPMENT OF PROPOSED STANDARDS; RULEMAKING Pursuant to section 307(a)(1) of the Act, the Agency published in the Federal Register on July 6, 1973, a list of nine pollutants (aldrin/dieldrin, benzidine, cadmium, cyanide, DDT (DDD, DDE), endrin, mercury, polychlorinated bi phenyls, and toxapliene) (38 FR. 18044). On September 7, 1973, this list was pro mulgated by the Agency as proposed, to gether with a discussion of the Agency's selection criteria and a response to the public comments received on the pro posed list (38 FR 24342). On December 27, 1973, the Agency published proposed toxic pollutant standards for each of the nine listed substances, together with a discussion of the factors considered in setting the standards, and a list of point source categories of dischargers proposed to be covered. (38 FR 35388) In accordance with section 307(a) (2) of the Act, a prehearing conference was held on January 25, 1974, followed by a 30-day evidentiary hearing during April and May, 1974. Following review of the record of the 1974 hearings, the Agency concluded that the record did not contain sufficient evidence upon which responsible and defensible stand ards could be promulgated, owing to In-, sufficient data in certain areas. The Agency then undertook to substantially expand Its data concerning the toxicity and environmental behavior and effects of PCBs. Thus, the rulemaking proceed ings which commenced with the proposal of standards on July 23, 1976 supersede the PCBs portion of the proposal of De cember 27, 1973. The standards proposed on July 23, 1976 were developed in the context of careful consideration of the "toxicity of the pollutant, its persistence, degrada bility, the usual or potential presence of the affected organisms in any waters, the importance of the affected orga nisms and the nature and the extent of the effect of the toxic pollutant on such organisms", as required by section 307 (a) (2) of the Act. In light of the Act's manifest concern for public health, which is discernible both on the face of the statute and in Its legislative history, the Agency also considered available data concerning human health effects attributable to PCBs. In its data gathering, the Agency was assisted by numerous persons within and outside the Agency, including biologists. chemists, and other experts in the vari ous EPA laboratories. Particularly In the area of toxicity and environmental be havior and effects of PCBs, the Agency was assisted by Ian C. T. Nisbet, Pli. D., of the Massachusetts Audubon Society. Dr. Nisbet is a nationally recognized ex pert on the toxicity of PCBs and is the principal author of the Agency's Criteria Document for PCBs", which was incor porated by reference as part of the state ment of basis and purpose for the stand ards proposed on July 23, 1976. Dr. Nis bet worked closely with key personnel in the Agency's Office of Water Plan ning and Standards and Office of ToxicSubstances in developing major portions of the criteria document. Based upon the data in the Criteria Document, tfae-Ageney "ambient.wager critegogJorPCBs pf ) pill't per trillion (0.001 micrograms per mer)? Althottgfflt was "virtually Impos sible to state with confidence that any number above zero provides an ample margin of safety for man," the Agency nevertheless concluded that the ambient water criterion would provide the requi site degree of safety for aquatic orga nisms and most consumers thereof likely to be affected, assuming a continuing or chronic presence at that level in the wa ter. Though not required by the Act, the setting of an ambient water criterion was utilized by the Agency as a step in arriving at an effluent standard which would apply at the point of the effluent discharge. Based on the ambient water criterion, tlie Agency proposed effluent standards for existing and new sources taking hito account the likely effects of dilution and dispersion following discharge into areas of mixing in the receiving waters imme diately surrounding the outfall. The pro posed standards included a prohibition on discharge of PCBs by any PCB man ufacturer. With respect .to any manu facturer of transformers or capacitors, a prohibition of any PCBs in any dis charge of process wastes was proposed, with limited exceptions, and an average daily concentration limit per month of 1 part per billion (1 nob or 1 microgram per liter) was proposed for any other discharge. For new sources a prohibition on discharge of PCBs.In process.wastes. ill' Cblljunc.tiinn--with an ayprn.ee daily concentration limit per montl^ol a tenth of a plflTpcr biTQfin7*wasproiiose(J. ** In developing the proposed standards, the Agency investigated and gave lim ited consideration to technical feasibil ity of compliance and economic impact. On August 20, 1976, the rulemaking hearings required by section 307(a) were commenced. The hearings continued on September 27, 28, 29, and 30; October 5, 12, 14, 15, 18, 19, 20, 21. and 22; and November 15, 16, 17, 19, 22, 23, nnd 30. The Agency presented the testimony ol 22 expert witnesses. The PCB Ad Hoc Committee of the Electronics Industries ("EIA") presented seven witnesses. The Environmental Defense Fund ("EDI'' ) presented one witness. None of the other objectors presented any witnesses. At the conclusion of the hearing, a briefing schedule was established. Except for the FEDERAL REGISTER, VOl. 42, NO. 22--WEDNESDAY, FEBRUARY 2, 1977 DSW 360934 STLCOPCB4097552 RULES AND REGULATIONS mT, New York State Department of Environ mental Conservation, all parties submit ted briefs and reply briefs. Hie American Paper Institute ("API") submitted no reply bricT. II. Findings A. RELEVANCE OF TOXIC SUBSTANCES CONTROL - ACT In their post-hearing briefs, both EIA and Westinghouse Electric Corporation argued that when Congress passed the Toxic Substances Control Act (Pub. L. 94-469, 90 Stat. 2003 (October 11, 1976)), It provided an exclusive means of regu lating PCBs. Section 6(e) of the Toxic Substances Control Act provides for a phase-out of the use of PCBs over a two and one-half year period, with provi sions for exemptions. . Section 6(e)(5) of the Toxic Sub stances Control Act provides that: This subsection does not limit the author ity of the Administrator, under any other provision of this Act or any other Federal law. to take action respecting any poly chlorinated biphenyl. Similarly, section 9 of that Act pro tions on the discharge of PCBs into U.S. waters. B. TIIE NATURE AND USE OF PCBS PCBs are mixtures of chlorinated bi phenyls with varying degrees of chlorina tion and isometric substitution. PCBs are hianufacturcd by the reaction of bi phenyl with chlorine in the presence of a catalyst. (A biphenyl is a hydrocarbon consisting of two six-membered carbon rings--or phenyl rings--joined to gether.) During the formation of PCBs, chlorine atoms ere substituted for hy drogen atoms successively at one or more of the 10 available positions on the bi-. phenyl molecule. Chlorinated biphenyls (CBs) are substances composed of bi phenyl molecules with 1 to 10 chlorine substitutions. CBs with the same number of chlorine atoms in the molecule are known as homologs (or congeners) and are named according to number of chlo rine atoms (e.g., the homologs with 4 chlorine atoms per molecule are called tetra-chlorobiphenyls or tetra-CBs). Each homolog may exist in a number of different forms, known as isomers, in which the chlorine atoms are attached to the molecules at different points. Each isomer is named according to the posi tions of substitution, following a stand ardized number scheme. PCBs are mix tures, each of which contains several homologs, each of which is represented by a number of Lsomers. PCB mixtures are usually analyzed by gas-liquid chromatography, and the pat tern of peaks on a gas-liquid chromato gram constitutes a "fingerprint" which is characteristic of the PCB mixture under study and can be used to identify the homologs and isomers contained in it. By means of gas-liquid chromotography, in combination with other tech niques, the homologs and isomers present in the major commercial PCB mixtures have been isolated and identified. PCBs are manufactured in the United States solely by Monsanto Industrial Chemicals Corporation, which markets commercial mixtures under the trade name Aroclor. The constitution of the four Aroclor mixtures now manufactured and sold in the United States can be summarized as follows: vides as follows: sec. e. RELATIONSHIP TO OTHER FED ERAL LAWS ***** Aroclor . Percent homologs with number of clilorino atoms '0 1 2 3 4 5 6 4 7 (b) Laws Administered, by the Administra tor. The Administrator shall coordinate ac tions taken under this Act with actions taken under other Federal laws administered in '1.121 . . 1,016........ . ___ 1.242........ . .... 1,254.............. .... * 21 41 42 54 11 0) Pi (.') 511 1 231C02...000 (>) .5 4 57 491 *> 21 2215 081...500 48.0 () ... 1 23 06) whole or In part by the Administrator. If the Administrator determines that a risk to health or the environment could be elim inated or reduced to a sufficient extent by actions taken under the authorities contained in such other Federal laws, the Administra tor shall use such authorities to protect against such risk unless the Administrator determines, in the Administrator's discretion, that it is in the public interest to protect against such risk by actions taken under this Act. This subsection shall not be con strued to relieve the Administrator of any requirement Imposed on the Administrator by such other Federal laws. Sections 6 and 9 of the Toxic Sub stances Control Act clearly establish my authority to take action with regard to PCBs under section 307 of the Federal Water Pollution Control Act. If It had chosen to do so. Congress could clearly have precluded further Agency action with regard to the control of PCB-laden discharges into the nation's waters. In stead, Congress appears to have done precisely the opposite: It expressly granted me the authority to harmonize the provisions of the Toxic Substances Control Act with my authority to regu late toxic substances under other laws. The Supreme Court has recently af firmed that "repeals by implication are disfavored" and that when statutes are capable of coexistence, each must be viewed as effective "absent a clearly ex pressed congressional intention to the contrary." Administrator, Federal Avia tion Administration v. Hobertson. 422 U.S. 255, 265-6 (1975). I find nothing in the Toxic Substances Control Act which relieves me of iiiy express responsibility under section 307 of the Federal Water Control Act for setting effluent limita Other PCB mixtures manufactured in the past and used in the United States include Aroclors 1232 (32% chlorine), 1248 (48% chlorine), 1260 (60% chlo rine). 1262 (62% chlorine), 1268 (68% chlorine), and 1270 171% chlorine). PCB mixtures have also been manufactured in several overseas countries and sold under other trade-names, including Clophen, Phenoclor and Kanechlor. Some, of these mixtures are being imported into the U.S. in small quantities. The consti tution of these mixtures is very similar to that of corresponding Aroclor mixtures. In addition to commercial mixtures, a number of individual chlorobiphenyl iso mers have been synthesized for research purposes and used for studies for PCBs. Successive members of the Aroclor series overlap very substantially In con stitution and contain a number of homo logs and isomers in common. As an ex ample, Aroclor 1016--the principal com mercial mixture--is almost identical in molecular and isometric constitution to Aroclor 1212, except that it contains slightly fewer of the higher boiling point constituents and, specifically, fewer pcntachlorobiphenyls; it does, however, overlap substantially in constitution with Aroclor 1242 and shares at least one major component In common with Aro clor 1254. One specific isomer (2,5.2',5'tetrachlorobiphenyl), which is present as a substantial component of Aroclors 1016, 1242, and 1254, has been used in a num ber of studies, and forms a useful indica tor of the environmental behavior of the components of at least the three men tioned mixtures. Because of this overlap between PCB mixtures, it is not possible to distinguish completely between them in weighing their environmental be havior and toxic hazards. PCBs are now used in the U.S. pri marily as- insulating fluids in electrical equipment. In 1974 approximately 40 million pounds were manufactured in the U.S. and approximately 450,000 pounds were imported. Between 65 and 70 per cent of domestic sales are to manufac turers of capacitors, most of the re mainder to manufacturers of trans formers, and about 1 percent to other users. Presently 90-95% of all impregnated capacitors manufactured in the U.S. are of the PCB type, and Aroclor 1016 is the principal mixture used. (Aroclors 1242 and 1221 are used in limited quantities.) PCBs are used as the dielectric fluids in 5-10 percent of the transformers manu factured in the U.S. The transformer oils are blends of 60-70 percent PCBs (Aroclors 1254 or 1242) and 30-40 per cent trichlorobenzene. Domestic sales of PCBs in 1974 (excluding imports) con sisted of 21,955,000 lbs. of Aroclor 1016, 6,207,000 lbs. of Aroclor 1242, 6,185,000 lbs. of Aroclor 1254, and 57,000 lbs. of Aroclor 1221. Small quantities of PCBs are used in the investment casting industry and as hydraulic and heat transfer fluids. They have been used in the past for many other applications. Studies of the be havior of PCBs in the environment re sulting from discharges due to these ap plications provide useful Information for evaluating the behavior of PCBs dis- FEDERAl REGISTER, VOL 42, NO. 22--WEDNESDAY, FEBRUARY 2, 1977 . DSW 360935 STLCOPCB4097553 filj34 RULES AMD REGULATIONS charged from capacitor and transformer of phytoplankton, and t-o reduce rale's of manufacturing plants. cell growth and division In phytoplank PCBs arc mobile oils or viscous liquids ton ; sensitive diatoms mixed with phyto at room tenliterature. They volatilize plankton arc replaced, by resistant green slowly at normal ambient temperature, algae at. PCB concentrations far below and have very low solubility in water. those required to affect cither species (The lass chlorinated components appear when cultured alone. Reductions in to be more soluble than the chlorinated growth and other effects have been re components). PCBs are freely soluble in ported at PCB concentrations as low as organic solvents. They are strongly par one-lentli of one part pc-r billion (the titioned from water into lipids (fats) in lowest concentration tested). Aroclor biological systems, resulting in large de 1242, which, with Aroclor 1016, is the grees of bio-accumulation. PCBs are subject of further specific comment strongly adsorbed onto solids, sediments, infra, has been shown to depress the rate and airborne and waterborne particu of photosynthesis by a marine commu lates. In aquatic environments, the nity of phytoplankton at lower concen adsorption leads to their passive trans trations than Aroclor 1254. This can have port with moving sediments and inhibits profound effects on the productivity of volatilization of PCBs from water sur an entire marine ecosystem. faces. PCBs that are adsorbed in sedi 2. In agnatic invertebrates and fish. ments can be released into the water and The acute toxicity of various PCB mix taken up by fish, even where the fish do tures to a variety of acquatic inverte not contact the sediments. Experiments brates and fish is well established. PCBs have shown that fish and shrimps kept are generally toxic to acquatic organisms in aquaria with contaminated sediments at much lower concentrations in chronic accumulate PCBs to high levels. exposures than in short-term exposures. PCBs are chemically stable and resist A number of species tested are affected ant to oxidation, reduction and other by chronic exposure to PCBs at con chemical reactions (they will undergo centrations of a few parts per billion, and photochemical reactions when irradiated the reproduction of the invertebrate with ultra-violet light or sunlight; how Daphnia magna was impaired at con ever, experimentation indicates little centrations as low as 0.48-1.0 parts per overall degradation of Aroclor 1254 after billion of Aroclors 1248 and 1254. The exposure to sunlight for 3 weeks). Photo midge Tanytarsus dissimilis was tested chemical degradation of PCBs gives rise through its full life-cycle and found to to, inter alia, small quantities of poly be affected by Aroclor 1254 at levels below chlorinated dibenzofurans ("PCDFs"), 1 part per billion (survival and growth which are toxic impurities. In at least were reduced 50 percent at the lowest one reported instance, PCDFs were test concentration of 0.45 parts per bil formed in toxicologieally significant lion). Reproduction in the mosquito quantities from PCBs during service in a Culex tarsalis was adversely affected at heat exchanger. . concentrations of Aroclor 1254 as low as Environmental residues of PCBs do 1.5 parts per billion; the same mixture not correspond to commercial mixtures is toxic to commercially valuable pe- very well, because of changes that occur naeid shrimp and grass shrimp at con after discharge. There are differences in centrations as low as 0.9--1.4 parts per the way less chlorinated components and billion. Brown shrimp exposed to sub- more chlorinated components are volatil- lethal levels of Aroclor 1254 for 7 days lzed, become soluble, and are adsorbed. died when the salinity of the water was Bacterial metabolism affects primarily decreased, and important result because mono- and dichlorobiphenyls; trichloro- shrimps need to adapt rapidly to chang blphenyls are metabolized much more ing salinity in their extensive euryhaline slowly and higher chlorobiphenyls hardly migrations. Aroclor 1254 markedly re at all. Tetra- and higher chlorobiphenyls duced the number and variety of species are well retained by fish; lesser chloro of estuarine animals developed from biphenyls are not as well retained. It is planktonic larvae at concentrations as therefore impracticable and confusing low as 0.1 parts per billion, the lowest to attempt to distinguish environmental concentration tested, and the fry of residues derived from discharges of vari sheepshead minnows suffered significant ous PCBs (and therefore impracticable to mortality when raised in water contain establish criteria or standards for spe ing a measured concentration of 0.16 cific Aroclors). parts per billion of Aroclor 1254. Resi C. THE TOXICITY AND OTHER ADVERSE EFFECTS " dues of PCBs in eggs from adult sheeps . . OF PCBS head minnows exposed to as little as 0.14 1. In bacteria and phytoplankton. Ex ppb of Aroclor 1254 resulted in decreased survival of embryos and fry'. Inclusion of periments and laboratory culture tests Aroclor 1254 in fish food at a level of 0.48 have established the following: PCBs in ppb resulted In a 52 percent increase in hibited the growth of estuarine bacteria thyroid activity in coho salmon, and in laboratory cultures; Aroclor 1242 thyroid activity was similarly Increased stimulated the growth of E. coli at low in lake trout by dietary exposure to 1.2 concentrations and (together with a con parts per million (ppm) Aroclor 1248, stituent of Aroclor 1016) Inhibited preda and growth was depressed. Rainbow tion on E. coli by other bacteria. (This Ls trout eggs hatching from eggs contain evidence of a potential effect on estuarine ing 2.7 ppm of a PCB mixture compa self-purification rates.) Also, PCBs have rable to Aroclor 1242 suffered a 75 per been shown to interfere with photo-' cent mortality in the first 80 days after synthetic mechanisms in certain species hatching, with 60-70 percent of the sur vivors being deformed. Swedish investi gators have reported a statistically sig nificant association between hatching failure of Atlantic salmon and PCB resi dues in the range 0.4 to 1.9 ppm.. The "fin rot syndrome," a fungal disease, has been reported in fish exposed to PCEs in both laboratory and field observations. Reproductive failure of several species of fish in Lake Michigan is associated with PCB residues in the lake water in the low parts per trillion. The evidence of record shows adverse effects of PCBs at ambient concentra tions as low as 0.1-0.14 parts per billion in laboratory bioassays and leaves little doubt that PCBs at concentrations below even 1 part per billion have ad verse effects on aquatic insects, crusta ceans, invertebrate communities and fish. 3. In birds. PCBs are very toxic to chickens, causing deaths within a few weeks at dietary concentrations as lew as 30-40 parts per million. Aroclor 1242 has been found to be more toxic to chickens than Aroclors 1254 and 1260. In several instances, wild fish-eating birds have been found dead with lethal con centrations of PCBs in their tissues. Tw o incidents involved the bald eagle, an en dangered species; one of these was from the northern part of the Lake Michigan, where the general level of PCBs in the ambient water is probably in the low parts per trillion. PCBs have marked effects on reproduction in chickens at dietary levels as low as 8-10 parts per million, corresponding to residues as low as 1-2 parts per million in their eggs. Aroclors 1242 and 1248 have been the most potent PCBs hi the chicken dietary ' results; Aroclor 1016 was much less active than Aroclor 1242 In one test. Ring doves exposed to PCBs at 10 parts per million for two generations suffered severe re productive failure; most of the eggs in the second generation failed to hatch and the embryos exhibited chromosomal abnormalities. Similar results have been found in American kestrels. A variety of other sublethal effects in birds have been found including the Induction of hepatic microsomal enzymes, the induction of porphyria, changes in thyroid activity, adverse behavior effects, reduction in size of the spleen and bursa of Fabrlcius, and Increased susceptibility to viral disease and vitamin E-selenium deficiency. 4. In mammals. Extensive data on the toxicity of PCBs in mammals were sum marized in the Agency's Criteria Docu ment and in the testimony of expert wit nesses. Witnesses who testified for the Agency concerning their own work on the toxicity of PCBs and its relevance for the assessment of human risk included Dr. Wilbur P. McNulty, Chairman of the Laboratory of Pathology at the Oregon Regional Primate Center; Dr. Renale D. Kimbrough, Medical Research Officer in the Toxicology Branch of the Center for Disease Control, U.S. Department of Health, Education, and Welfare; Dr. Robert A. Squire, Head of the Tumor Pathology Section, Associate Cliicf of the Experimental Pathology Branch, and Acting Chief of the Carcinogenic Bio assay and Program Resources Branch, in the National Cancer Institute; D;. . FEDERAL REGISTER, VOL. 42, NO. 52--WEDNESDAY, FEBRUARY 2, 1977 DSW 360936 STLCOPCB4097554 RULES AND REGULATIONS . . ; : 6535 Harry V. Gelboin, Cliief of the Chemis within one month. After two months the per million all died. The monkeys ex try' Branch, Division of Cancer Cause and animals were so ill that they were re posed to 3 ppm and 10 ppm died after Prevention, National Cancer Institute; moved from the experimental diet. One 245 and 146 days' exposure respective Dr. James R. Allen, Professor in the De animal died two months later; on autop ly. All the monkeys showed facial swell partment of Pathology and Food Micro sy It also exhibited acne and ulceration ing, red and swollen eyelids, conversion biology and Toxicology at the University of the gastric mucosa of the stomach. of all secretory cell types of the stomach of Wisconsin, Madison and Senior Scien The female rhesus monkeys which sur to mucous cells, growth of mucous glands tist at the Wisconsin Regional Primate vived 2 months' exposure to 25 ppm of into the muscular wall of the stomach, Center; and Dr. Robert K. Ringer, Pro Aroclor 1248 have been observed for 3 multiple ulcers in the stomach, atrophy fessor in the Departments of Physiology years and still show symptoms of poison of the thymus gland, and either disap and Poultry Science in the Colleges of ing. They have given birth to six infants, pearance of sebaceous glands or conver Veterinary Medicine, Human Medicine, all of which weighed at least 150-200 sion of these glands to keratin cysts, par Osteopathic Medicine, Natural Science, grams less than infants born to control ticularly in the eyelids. Other monkeys and Agriculture at Michigan State animals. . exposed to lo ppm of Aroclor 1242 University. Infant rhesus monkeys born to experi showed similar effects. EDF was the sole objector which pre mentally exposed mothers contained In tests by Dr. McNulty with individ sented an expert toxicologist as a witness PCBs in their tissues at birth, indicat ual chlorobiphenyl isomers, a trichloro- (Roscoe Moore, who presented prelimi ing a transplacental movement of PCBs biphenyl and a pentachlorobiphenyl nary data on the incidence of cancer from the mother to the fetus. Invari proved relatively non-toxic to rhesus among occupationally exposed workers). ably infants showed a decided increase monkeys, but a representative tetrachlo- EIA presented one witness, Dr. Wolf in their tissue levels of PCBs following robiphenyl was very toxic and killed the gang Mueller, who criticized some of the nursing as a result of the high levels of test animal in less than 60 days' exposure toxicological studies and interpretations PCBs in the mother's milk. to 10 ppm in the diet. " presented by EPA witnesses. Dr. Mueller Infant rhesus monkeys dosed with 35 Comparison of the results of Drs. Allen is an expert in chemistry and toxicoki mg/kg of Aroclor 1248 for only 4 weeks and McNulty suggests that Aroclor 1242 netics and conceded that he was not an suffered skin lesions, atrophy of the is more toxic to rhesus monkeys than expert in pathology, toxic effects, or car thymus, edema and hyperplasia of the Aroclor 1248, since in the experiments by cinogenesis. He also conceded that en gastric mucosa, and enlargement of the Allen monkeys survived and even pro zyme induction is not his specialty. He liver with proliferation of the smooth duced a few young on 5 ppm of Aroclor admitted that he had not read all the endoplasmic reticulum. Although this 1248, whereas in the experiments of original papers supporting the conclu study may indicate the rhesus monkeys McNulty the monkeys were severely sions which he criticized. Moreover, al are more sensitive to PCBs when exposed affected by 10 ppm of Aroclor within 60 though he claimed familiarity with work naturally (via transplacental passage ' days' and the animal exposed to 3 ppm bn the toxicology of PCBs in his labora and mother's milk) than when dosed died. tory, he was not aware of work on the after birth, the study was terminated too Dr. Mueller's suggestion that little toxicology of PCBs in five species of early for definite conclusions. weight can be placed on Dr. McNulty's mammals at another branch of the same Female rhesus monkeys fed diets con findings was based on the false propo institute, and had not contacted the taining 2.5 and 5.0 ppm of PCBs devel sition that McNulty's conclusions were Director of that institute for informa oped the classical signs of PCB intoxica based solely on the death of one monkey tion about these studies. Dr. Mueller's tion (swelling of eyelids, loss of eye exposed to 3 ppm. In fact, however, Dr. testimony in regard to toxicology was lashes, edema of the face, and acne) McNulty's conclusions were based not limited to rats and rhesus monkeys. within two months. After six months, the only on the death of this animal, but Neither he nor any other witness at test animals were mated to control also upon the deaths of animals at 10 tempted to refute or question the evi males. Of the 8 animals that received ppm and higher doses of Aroclor 1242, dence introduced into the record by the the 5 ppm diet, only one gave birth, upon the experiments with the pure Agency as to the toxicity of PCBs to there were five abortions and two did tetrachlorobiphenyl isomers, and upon other mammals, including dogs, mink, not conceive even after repeated breed the clinical and pathological observa pigs, and humans. '. ings. tions on the entire series of exposed PCBs have low acute toxicity to rats Of 8 female rhesus monkeys fed the 2.5 animals. and mice. In subacute toxicity studies, ppm diet, only 5 gave birth and 3 abort Dr. Robert K. Ringer testified as to rats and mice proved relatively resistant ed. The 5 live-bom infants were ex the results of a series of studies of the to PCBs, whereas guinea pigs, rhesus tremely small. In addition to their diffi toxicity of PCBs to ranch mink. Miiik monkeys, mink, and big brown bats were culty in maintaining pregnancy, these fed on coho salmon from Lake Michigan much more sensitive. . animals exhibited irregular menstrual in the late 1960's suffered from repro In chronic feeding studies, similar dif cycles and extensive menstrual bleeding. ductive failure and kit mortality. After ferences between species in susceptibility Infant rhesus monkeys, born to moth a series of experiments the cause of the to PCBs were noted. Rats, mice, and dogs ers fed 2.5 ppm of PCBs showed a reproductive failure was traced to PCBs, survived well for periods of up to 1-2 rapid increase in tissue levels as a result present at levels of 12-20 ppm in the years at dietary levels as high as 100-300 of ingestion of PCBs in their mother's salmon. The results of the poisoning of parts per million of various PCB mix milk. Within 2 months, the infants be the mink from the contaminated Great tures, although a variety of physiological gan showing signs of PCB intoxication Lake Salmon had the commercially cata and pathological changes were induced that progressively increased in severity. strophic effect of wiping out a major in them. In contrast, rhesus monkeys, Three of the six infants died within four segment of the Great Lakes fishfood mink, pigs, and rabbits suffered deaths months after birth. Behavioral and industry. . and/or reproductive dysfunctions at learning experiments conducted on the Mink exposed experimentally by Dr. lower levels of exposure. surviving Infants for one year following Ringer to a diet containing 30 ppm of a In studies conducted by Dr. James weaning have revealed deficits in both mixture of PCBs all died between the Allen, rhesus monkeys fed diets contain areas. beginning of the breeding season and the ing 100 and 300 ppm of Aroclor 1248 de Female j'hesus monkeys ' which had end of the whelping period. Clinical signs veloped severe acne, swelling of the eye been maintained on dietary levels of 2.5 and lesions were anorexia, pathological lids and face, loss of hair, and severe or 5.0 ppm of PCBs for 16-18 months loss of appetite, bloody stools, fatty de ulceration of the stomach together with have been placed on normal diets for one generation of the liver and kidneys and thickening of the gastric mucosa. All of the animals died within 2-3 months. Female rhesus monkeys fed a diet con taining 25 ppm of Aroclor 1248 devel oped facial lesions similar to those in year but have continued to give birth to affected infants. Dr. McNulty testified as to the results of a series of toxicity studies conducted with rhesus monkeys exposed to Aroclor 1242. Monkeys exposed to dietary levels hemorrhagic gastric ulcers. Mink fed Aroclor 1254 at 5 and 10 ppm in the diet suffered increased mortality, enlargement of the liver, kidney, and heart, and reduced weight gains. These effects were enhanced by simultaneous animals exposed to 100 and 300 ppm of 800, 400, 200, 100, 30, 10, and 3 parts feeding of DDT or dicldrin. ' TEDERAL REGISTER, VOL. 42, NO. 22--WEDNESDAY, FEBRUARY 2, 1977 v;:V -. ; ` Dsvv 350937 STLCOPCB4097555 6536 r. . RULES AND REGULATIONS Female mink fed 5 ppm of Aroclor 1254 produced no young hi one test, and only 3 young were bom alive from 12 .females In a second test. Reproduction was also impaired at 1 ppm of-Aroclor 1254, because one female died and two others produced no young. Female mink exposed to Aroclor 101G at 2, 10, and 25 ppm In the diet suffered -impaired reproduction at all three dosage levels. Although Aroclor 1016 does not were not reported in the dogs fed Aroclor 1242 at 1 ppm, Dr. Nlsbet testified that this might well be due to chance, in view of the high Incidence in animals fed this Aroclor mixture at 10 and 100 ppm. Dr. Renate D. Kimbrough presented extensive testimony as to her experi ments on the toxicity of PCBs to rats. Additional data on the toxicity of PCBs to rats was described in the testimony of Dr. Allen and in the Criteria Document. males. On prolonged exposures to Avoclors 1016, 1242, 1248, 1254, 1260 and 1262, rats have consistently developed a variety of pathological changes in the liver. Increase in liver weight in animals exposed to PCBs has been observed in a number of experiments with rats, and is also a toxic effect of PCBs in other mam mals, including mice, rabbits, pigs, dogs, rhesus monkeys, and squirrel monkeys. Rats display marked increases in liver appear to be as toxic to mtnk as Aroclor Sherman rats exposed to Arochlors 1254 weight when exposed to PCBs for only a ' 1254, the effect of Aroclor 1016 on repro and 1260 at dietary levels of 20, 100, 500 few weeks; the effects appear slightly duction was marked at 2 ppm, the lowest and 1,000 ppm for 8 months showed en greater with the more chlorinated mix dose tested.1 At this dose level the num largement of the liver at all dose levels. tures, but in an experiment with Aroclor ber of kits raised to 4 weeks of age was Microscopic examination of the liver 1016, marked effects were seen in only 21 scarcely half that raised by the controls. cells showed a variety of changes, includ days after oral dosage of an amount Dr. Ringer testified that if the entire ing enlarged hepatocytes, inclusions in equivalent to about 8 ppm in the diet for picture of reproduction performance in cytoplasm, foamy cytoplasm, and (at rats of the age concerned. these experiments is considered, the re higher doses) increased lipids, brown pig Extensive experiments summarized in duction in the number of kits raised is ment, and adenofibrosis** the Agency's Criteria Document have very important. In a subsequent study, smaller num shown that PCBs induce a variety of en In an independent series of experi bers of Sherman.rats were exposed to zymes in the livers of rats and other spe ments by Platonow and Karstad in which Aroclors 1242 and 1016 at 100 ppm in cies, and that PCBs are especially potent mink were fed a diet containing beef the diet. Changes in the liver were gen inducers of an enzyme system known as from cows which had been exposed to erally similar to those found in the rats the mixed function oxidase system. Aroclor 1254, all the mink fed at a dietary treated with Aroclors 1254 and 1260, but Mixed function oxidases are responsible level of 3.57 ppm died within 105 days. were somewhat less severe. The changes for the detoxication of foreign chemicals, Two. of 12 females dosed at a dietary were slightly, but not markedly, less but may also be detrimental to an orga level of only 0.64 ppm PCBs died; only severe in the rats fed Aroclor 1016 than nism by metabolizing ingested chemicals one of the 10 survivors produced a litter, in those fed Aroclor 1242. to active toxic or carcinogenic forms. and 11 of her kits died during the first- Sprague-Dawley rats fed diets contain Both PCB mixtures and a large number day of life. Comparison of the results of ing 100 ppm of Aroclors 1248, 1254 and of individual chlorobiphenyl isomers in the toxicity of tests carried out by Plato 1260 for a period of 52 weeks also dis duce microsomal enzymes in the livers of now indicates that the PCB mixture used played enlarged livers and a variety of rats and other animals, including nitro became more toxic to mink during me microscopic changes in the liver, includ reductase, demethylases, deethylases, tabolism and storage in the cows. ing degeneration, enlarged cells, and fo glucose-6-phosphatase, aryl, hydrocar The reproductive performance of sows cal necrosis. bon hydroxylases, cytochrome P-450, and was severely impaired by exposure to a Dr. Kimbrough reported a study in NADPH cytochrome reductase. Aroclor dietary level of 20 ppm of Aroclor 1242 which Sherman rats were exposed for 1016, 1242, 1248, 1254 and 1260 induce from three weeks prior to conception generations to dietary levels of 1, 5, 20, several enzymes in rats after exposure to through gestation and nursing. One of and 100 ppm of Aroclor 1254, and 2. 20, only -0.5 ppm iri the diet, or 1 mg/kg/day, five treated sows failed to conceive and 100, and 500 ppm of Aroclor 1260. Ad for only 21-28 days. PCBs have been the other four produced significantly verse effects on reproduction were ob shown to enhance the metabolism of cer- fewer live young than controls, due to an served in the rats exposed to 20 and 100 tain drugs and to promote the toxicity of excess of still births and fetal deaths. ppm of Aroclor 1254, in that the number vinyl chloride in rat livers by enhancing The principal lesions observed in sows treated with Aroclor 1242 at 20 ppm in of pups per litter was reduced. In Dr. Kimbrough's two-generation reproduc its transformation to a more toxic metab olite. \ the diet and in their offspring were ero sions in the gastric mucosa. A number tion experiments liver weights were in creased in the offspring of rats fed PCBs Dr. Gelboin testified that the published studies on enzyme induction by PCBs and of offspring of treated sows, but no con at dietary levels as low as 1 ppm of Aro the biochemical characteristics of the trol offspring, died from septicemia, in clor 1254 and 5 ppm of Aroclor 1260. systems involved "certainly indicate that dicating that exposure to PCBs had in creased their susceptibility to infection. Feeding of Aroclors 1242, 1254, and 1260 to groups of beagle dogs at dietary level of 1, 10 and 100 ppm for a period of two years caused several deaths and dose-related increases in liver weight, 6erum alkaline phosphatase levels, and leukocyte counts. The noteworthy find ings in chronically exposed dogs were numerous pinpoint nodules in the stom achs: these were observed in 22 of the 66 PCB-treated dogs, but in none of the controls. . ' Stomach lesions were induced in dogs by Aroclors 1242, 1254, and 1260 at all dietary levels down to 1 ppm, the lowest dose tested. Although stomach lesions Pathological changes in the livers were noted in the offspring of rats at doses as low as 1 ppm, including neoplastic nod ules * in 3 of 7 female rats at 20 ppm of Aroclor 1254. _ In a three-generation reproduction study carried out with rats, reproduction was adversely affected in the second and third generations exposed to Aroclors 1242, 1254, at 1260 and 10 and 100 ppm. The cause of the adverse effects was a decrease in the mating indices and in the Incidence of pregnancy. Exposure of rats to Aroclor 1016 at a dietary levels of 30 and 100 ppm for 90 days caused marked and significant reductions in gonad weights in the fe 1 Adenofibrosis Is a term given to a greyish- PCBs would exhibit enzyme-inducing activity in humans". Dr. Gelboin further testified; "Since there are ubiquitous low ' levels of chemical carcinogens in the human environment, alteration of this enzyme system would be expected to change the incidence of human cancer due to these carcinogens. Thus PCBs can be suspected of altering the incidence of cancer In humans". He added that en zyme induction by PCBs "would violate the functional integrity of the human since an enzyme inducer would be ex pected to change the metabolism of drugs which may be needed for therapeutic processes, the metabolism of the normal regulation steroid hormones, and car cinogenic chemicals to which man is exposed". white area or areas which have proliferated PCBs also cause chemical prophyria in 'Dr. Ulngcr also referred to another ex in the liver cells, that at times can be quite experimental animals . (rats, mice and periment at this dose level In which no significant adverse effects had been marked and suggested that the diff erence could be explained as due to biological variability. Blnce clear adverse effects were obtained In atypical, together with proliferated fibrous, scar-type tissue. It Is often induced by car cinogens and is believed to be pre-canrerou';'. * A neoplastic nodule is a nodular prolifera tive lesion in the liver, considered by special rabbits) by stimulating the production of the enzyme delta-aminolevulinic acid synthetase, causing accumulation of por phyrins in the liver and elsewhere. one of the two experiments. 2 ppm certainly ists to be either preenneerous or already PCBs have also induced other biochem cannot be regarded as a "no-effect" level. cancer. ,. ical effects in experimental animals (in- FEDERAl REGISTER, VOl. 42, NO. 22--WEDNESDAY, FEBRUARY 2, .1977 DS\N 360938 STLCOPCB4097556 V. . RULES AND REGULATIONS ' . 6537 eluding inhibition of immune responses characterized by skin lesions and some The work of Dr. Allen and Dr. McNulty in rabbits and guinea-pigs; atrophy of times systemic disturbances. However, indicates that the rhesus monkey is the the thymus and/or spleen in chickens, the relative roles of PCDFs, PCBs and most appropriate model for the toxic mice, rhesus monkeys and pigs; and in other chemicals in causing chloracne are effects of PCBs in humans. The skin creased susceptibility of piglets to septi confused. lesions found in rhesus monkeys and cemia, of ducks to viral hepatitis, and of EDF's sole witness, Roscoe M. Moore, th'elr offspring fed low doses of PCBs fish to fungal disease). Jr., an epidemiologist at the National In aro closely parallel to those found in 5. Toxicity at low exposure levels. A stitute of Occupational Safety and humans afflicted with Yusho and chlor - number of toxic effects of PCBs in mam Health (NIOSH), reported the prelimi acne. Although there are few autopsy mals have been noted at very low levels nary results of an epidemiologic analysis reports on Yusho victims that specify of exposure. For most of these critical based on medical records of two small the condition of the stomach, the long toxicological effects, significant effects of PCBs have been noted in animals at the lowest exposure levels tested. With one exception, "no-effect;' levels have not been established or reported. Mink exposed to Aroclor 1254 at 0.64 ppm in the diet suffered some mortality and total reproductive failure, and those exposed to Aroclor 1016 at 2 ppm also suffered impaired reproduction. Liver weight in weaning rats in the second generation exposed to Aroclor 1254 at 1 ppm in the diet was significantly in creased, and pathological changes were also noted. This is the lowest dietary level at which rats have been exposed to PCBs in multi-generational tests. Stomach ul cerations and nodules were induced in dogs after exposure for two years to a dietary level of 1 ppm of Aroclors 1254 and 1260 and 10 ppm of Aroclor 1242. Rhesus monkeys exposed to 2.5 ppm Aro clor 1248 in the diet suffered dermal and stomach lesions and severe reproductive failure; several of their infants died and the survivors were impaired in behavioral and learning performance (the exposed monkeys continued to give birth to af fected infants after 16-18 months on an uncontaminated diet). Rhesus monkeys exposed to 3 and 10 ppm of Aroclor 1242 suffered severe stomach and dermal lesions and died after 60-245 days. These are the lowest doses to which rhesus monkeys have been exposed. Exposure of rats to 0.5 ppm (the lowest exposure level tested) of Aroclors 1242, 1248,. 1254 and 1260 in the diet for 4 weeks caused significant induction of several hepatic microsomal enzymes. Exposure of male rats for 21 days to daily doses of amounts of Aroclor 1016 and 1242 comparable to 0.8 ppm in the diet has been reported as a "no-effect" level for effects on liver weight. However, little weight is placed on this report because the experiment involved exposure for only 21 days, and in another experiment Aroclor 1242 had significant effects at lower doses; fur ther, Dr. Nisbet testified that there would be no reason to doubt that Aroclor 1016 would have effects at 0.5 ppm in the diet. Sows exposed to Aroclor 1242 at 20 ppm in the diet suffered stomach lesions groups of employees exposed to Aroclor 1254 at Mobil Oil Company's Paulsboro, New Jersey plant between 1949 and 1958. An elevated incidence of skin cancer (melanoma) and pancreatic cancer was found among research and development and refinery plant employees between 1957 and 1975. This was the first study associating PCBs with melanoma and/ or pancreatic cancer. Although the anal ysis is still preliminary and has limita tions (including the fact that the extent of exposure of the employees to other chemicals was unknown), the findings do add to the cencern expressed below with respect to potential carcinogenicity in humans. "Yusho" is a disease reported in Japan late in 1968 and traced to consumption of rice-oil contaminated with PCBs from a leaking heat-exchanger early in that year. At least 1,291 pei'sons were severely affected, and extensive reports have been published on the episode. The contami nated rice-oil is reported to have con tained about 1,000 ppm of PCBs of a type equivalent to Aroclor 1248, and also contained about 5 ppm of a mixture of PCDFs. Symptoms of Yusho are similar to those of chloracne, involving skin lesions, hyperpigmentation of the skin, and hy persecretion of the Meibomian gland of the eyelid, together with digestive dis turbances, fatigue, headache, cough and abdominal pain. A number of live-bom and at least two still-bom children were affected. At least one baby appears to have been poisoned via its mother's milk. Recovery from Yusho has been very slow and the symptoms of internal disturb ance are now more prominent than in 1968. Preliminary tabulations of deaths among Yusho victims suggest an excess of cancer, especially of the stomach and liver, but precise data are not yet avail able. As in the case of chloracne, the rela tive roles of PCDFs and PCBs in caus ing Yusho are uncertain. Because of the relatively large exposure of the Yusho victims to PCDFs, it is probably inappro priate to use the data from the Yusho episode to make quantitive estimates of history of digestive disturbances re ported in victims of Yusho and chloracne suggest a parallel with the stomach ul cerations found in rhesus monkeys. 7. .Carcinogenic and related effects. Carcinogenic activity in rodents is gen erally accepted by the scientific commu nity as an indicator that a chemical poses a potential carcinogenic risk to humans. This principle has been adopted as gen eral Agency policy for evaluating car cinogenic risks,* has been utilized in prior Agency Decisions,5 and has been recog nized by the U.S. Court of Appeals as a matter within the Agency's expertise.* On prolonged exposure to Aroclors 1016, 1242, 1248, 1254, 1260 and 1262, rats have consistently developed a vari ety of pathological changes in the liver, some of which represent neoplastic or preneoplastic transformations. PCBs have been shown to induce carcinogenic or precarcinogenic effects in rats and mice in addition to other pathological transformations. Dr. Renate Kimbrough described an experiment conducted by herself, in which Sherman rats fed 100 ppm of Aroclor 1260 in the diet for 21 months developed hepatocellular carcinomas (26/184) and neoplastic nodules (144/ 184) in the liver, whereas 173 control animals developed only one carcinoma and no neoplastic nodides. The carcino mas were diagnosed not only by Dr. Kim brough, but also Dr. Squire and two other reviewing pathologists; they were de scribed and illustrated in detail in the report published by Drs. Kimbrough, Squire, and their co-authors. As a re sult of this well-conducted and wellreported experiment it can be concluded that Aroclor 1260 is hepatocarcinogenic in rats. In earlier experiments by Dr. Kim brough, exposure of rats to dietary levels of 500 ppm of Aroclor 1254 or Aroclor 1260 induced adenofibrosis in the livers of most of the animals within 6-8 months. The lesions persisted In the livers of the rats even after 10 months' maintenance on uncontaminated diets. Adenofibrosis was also induced, although at lower frequency, in the livers of rats and significant reproductive failure. the toxic hazard posed by PCBs to hu exposed to 100 ppm of Aroclor 1254 for This is the lowest dose at which pigs mans. However, because the PCDFs ap have been tested with PCBs. pear to have been formed in service, the `Interim Procedures and Guidelines for 6. Toxicity in human beings. Dr. Nisbet testified that with the possible exception Yusho episode dramatically illustrates the fact that environmentally trans Health and Kconomlc Impact Assessment of Suspected Carcinogens, 41 PR 21402, May 2, 1976. ' of the results with mink, all effects noted formed residues of PCBs may be more `Opinion of the Administrator, Environ in mammals have relevance for humans (particularly the symptoms of PCB poi soning in monkeys). PDCFs--which can be created by pho tochemical degradation of PCBs--arc implicated as well as PCBs in the cause of chloracne, an occupational disease hazardous than the pure mixtures tested in laboratory bioassays. It also illustrates that the potential hazards of PCBs can not be evaluated in Isolation from those of the PCDFs that are usually found with them. mental Protection Agency on the Suspension of Aldrln-Dleldrln, 39 FR 37266, ct seq., (Oct. 18, 1974); Decision of the Administra tor on the Suspension of Hcptachlor-Chlordanc, 41 FR 7572, ct seq. (Feb. 19, 1976) ''EDF v. EPA", 610 F. 2d 1292 (D.C. Clr. 1976), "EDF v. EPA", 9 ERC 1433 (D.C. Clr. 1976). ` - '' ' . . FEDERAL REGISTER, VOL. 42, NO. 22--WEDNESDAY, FEBRUARY 2, 1977 . .> :--' . ' - . - DSW 360939 STLCOPCB4097557 '4>538 . RULES AND REGULATIONS 8 months. No adenofibrosls was observed in rats exposed to a similar dosage regime of Aroclors 1016 and 1242, but this is not a significant negative finding be cause sample sizes were very small and only males (less sensitive than females to Aroclor 1254) were tested. In one of Dr. Kimbrough's experi ments in which rats were exposed to Aroclor 1254, abnormal tissues with cells similar to those in the pancreas were found growing in the livers of treated rats. ' In another experiment reported by Dr. Kimbrough in which rats were exposed to PCBs for two generations, neoplastic nodules were found in the livers of the offspring treated with 100 ppm of Aro clors 1254 and 1260; 3 neoplastic nodules were found in the livers of 7 second gen eration rats exposed to only 20 ppm Aro clor 1254 and sacrificed at the age of only 328 days. This very early development of neoplastic nodules at low dietary levels suggests that rats are more sensitive to the ^carcinogenic activity of PCBs when exposed in utero and in infancy than later in life. Dr. Kimbrough also reported an ex periment in which neoplastic nodules and adenofibrosls were induced in the livers of mice by exposure to a dietary level of 300 ppm Aroclor 1254 for 11 months (in one case for 6 months, followed by 5 months on uncontaminated diet). In a comparative study carried out by Industrial Bio-Test Laboratories and summarized in detail in the Criteria Document, groups of 100 male and female Charles River strain rats were exposed for 24 months to dietary levels of 1, 10 and 100 ppm of Aroclors 1242, 1254, and 1260. Although the survival of the rats was comparatively poor and the experi ment has been inconsistently reported, the most recent review of the slides by the original pathologist indicated the oc currence of liver tumors ("hepatomas" and "cholangiohepatomas") in animals treated with all three Aroclor mixtures. The incidence of liver tumors In the rats exposed to 100 ppm was 3/20 for Aro clor 1242, 6/27 for Aroclor 1254, and 7/27 for Aroclor 1260, versus 0/20 in controls. In addition to lesions listed as tumors, the most recent report on the Industrial Bio-Test experiment shows high fre quency of "nodular hyperplasia"--a le sion now authoritatively considered to be at least pre-cancerous. The reported in cidence of nodular hyperplasia in the rats treated as 100 ppm was 8/20 for Aroclor 1242, 13/27 for Aroclor 1254 and 7/27 for Aroclor 1260, versus only 1/23 for con trols. Nodular hyperplasia was reported as frequent even in the rats treated at 10 ppm; 2/30 for Aroclor 1242, 3/26 for Aro clor 1254, and 9/23 for Aroclor 1260, ver sus only 1/23 for controls. Dr. Nisbet tes tified that although this Increase in in cidence was not significant for Aroclor 1242 considered alone, such a conclusion can be drawn for the tliree Aroclors con sidered together. In addition to liver tumors, the incidence of tumors of the pituitary gland was elevated in all treated groups in this experiment. Although the results of the Industrial Bio-Test experiment need further re evaluation, the reported results consti tute prima facie evidence of carcinogenic effects of Aroclors 1242, 1254, and 1260 at 100 ppm and even at 10 ppm in the diet. The results of the Industrial Bio Test experiment do not suggest a marked difference betwen the effects of Aroclors 1242, 1254, and 1260 in inducing tumors and nodules in the livers of rats. The re sults are therefore relevant to weighing the potential effects of Aroclor 1016, In view of the close chemical similarity be tween Aroclors 1016 and 1242. - In three other experiments summa rized in the Criteria Document, Japanesemade PCB mixtures (Kanechlors 500, 400, and 300) are reported to have in duced a variety of cancerous and precancerous lesions in the livers of rats and mice. The lesions were variously de scribed as cholangiofibrosis, nodular hy perplasia, multiple adenomatous nodules, and hepatocellular carcinoma. Although these experiments were conducted for relatively short periods at high doselevels, they support and extend the find ings that Aroclor mixtures have carci nogenic effects in rats and mice. In another study in rats, feeding with PCBs (Kanechlor 500) appeared to de lay or inliibit the action of three other liver carcinogens. However, pretreatment with PCBs greatly increased the suscep tibility of rat livers to acute injury by vinyl chloride monomer, a known hu man liver carcinogen. This effect is at tributable to the action of PCBs in stim ulating the liver microsomal enzyme sys tem, which oxidizes vinyl chloride to a biologically active metabolite; such acti vation is known to be required to convert vinyl chloride into an active mutagenic agent. Numerous studies have shown that PCBs activate mutagens (i.e., carcino gens and presumptive carcinogens) to their biologically active forms in vitro by stimulating the mixed function oxidase system in liver microsomal preparations. In some cases PCB-stimulated enzymes activate secondary carcinogens to bio logically active forms; in other cases they de-activate primary carcinogens. ' It has become standard practice to use Aroclor 1254 as a stimulator of the mixed function oxidase system in bacterial mutagensis bioassays to screen suspected carcinogens. The action of PCBs in ac tivating some carcinogens and mutagens, while dc-activating others, can be un derstood as a result of their exceptional potency and broad-spectrum action in stimulating liver microsomal enzymes. These observations are of profound im.portance in evaluating the environmen tal significance of PCBs, because PCB mixtures (Including Aroclors 1254, 1242, and 1016) have been found to stimulate the mixed function oxidase system at ex tremely low doses. According to Dr. Gelboln, stimulation of the microsomal en zyme system is expected to change the Incidence of cancer in humans. In addition to the carcinogenic and co-carcinogenlc effects of PCBs, the im- munisuppressive effects of PCBs are also expected to be important in potentiating the effects of other carcinogens, since suppression of immune responses may make an animal more susceptible to es- tablishment of neoplastic cell lines and development of malignant tumors. The objectors offered no evidence whatsoever that would refute or modify the evidence introduced by EPA that PCBs are carcinogenic and co-carcino genic in animals. Nor did they offer any evidence that would call into question the implication of this finding that PCBs are likely to be carcinogenic in humans. PCBs have shown by adequate test ani mals to be carcinogenic in animals. Fol lowing the consensus of scientific opinion on the subject, PCBs should therefore be regarded as a potential carcinogenic hazard to humans. . ... D. PEItSISTANCE AND MOBILITY OP PCBS Except for the least chlorinated homo- iogs, PCBs are resistant to degradation by metabolism. Bacteria can metabolize biphenyls and mono- and dichlorobi- phenyls fairly rapidly, but tri- and tetra- chlorobiphenyls are degraded much more slowly and pentachlorobyphenyls are de graded hardly at all. Aquatic inverte brates and fish can metabolize triclilo- robiphenyls to a substantial degree but have little ability to metabolize tetra- or pentachlorobiphenyls. Birds and mammals can metabolize tetra- and pen tachlorobiphenyls to hydroxy deriva tives at varying speeds, but have little ability to metabolize hexa- or higher chlorobiphenyls. PCBs have a long life in the environ ment. In one case they were identified in anaerobic marine sediments that could' be dated to the mid-1940's. More chlo rinated homologs have a life-time of years, and perhaps decades, in the en vironment. This storage of highly con centrated levels of PCBs in the tissue leads to exposure of organs of the animal to PCBs via the circulatory system, which in turn can cause acute or chronic ad verse effects to that organism. When organisms containing PCBs in their tissues are consumed, the consumers may in turn suffer chronic or acute adverse effects. i A series of experiments in which vari ous PCBs (including Aroclor 1016) were incubated in the laboratory with anaer obic lake sediments for up to nine months showed no measurable degrada tion. Similar experiments with various di-, tetra-, penta- and hexachlorobi- phenyls involving incubation in soils with and without cattle manure for one month showed no indication of any metabolism. PCBs are mobile in the environment _ and are transported in solution, by mo tion of suspended sediments, as vapors or airborne particulates, or in tire tissues of mobile animals. Dr. David Young de scribed an extensive series of investiga tions of the occurrence and dispersal of PCBs in the coastal waters of the South ern California Bight between 1972 and 1975. These investigations showed that the principal route of entry into the - '. : FEDERAL REGISTER, VOl. 42, NO. 22--WEDNESDAY, FEBRUARY 2, 1977 ' ' vy-s . . . , y . , . DSW 360940 \ . yy, - - v:- ' " ' ..r STLCOPCB4097558 RULES AND REGULATIONS 6539 coastal waters of PCB mixtures resem bling Aroclor 1242 (tri- and tetracholoro- biphenyls) and Aroclor 1254 (pcnta- and hexachloroblphenyls) was via municipal wastewater discharges through offshore sewage outfalls. As a result of the dis charges, PCBs had become widely dis tributed In sediments and biological organisms (crabs, fish, mussels, etc.) in the whole area. The concentrations of both groups of chlorobiphenyls were highest in both sediments and biota in the vicinity of the outfalls. Dr. Young's monitoring studies have shown a marked decline in the input of PCBs of the 1242-type. However, al though the rate of input of PCBs has fallen by a factor of at least 14 since 1962, the concentration of PCBs in sediments and fish have fallen by factors of only 1.2 and 1.9 respectively. Similar findings were obtained for DDT and metabolites, adding to the degree of confidence in the data on PCBs. Dr. Young's conclusion from this study was that "contamination of sewer and ocean bottom sediments by chlorinated hydrocarbons such as PCBs can cause these synthetic compounds to ^persist in bottom-feeding fishes long after major reductions have been made in the dominant inputs". This conclusion about the persistence of PCBs in sedi ments and fish applies as much to tri- and tetrachlorobiphenyls as to penta- and hexachlorobiphenyls. As a result of their persistence and mobility in the environment, PCBs have become widely (indeed almost univer sally) distributed through the world. Dr. Robert Risebrough introduced a sum mary of his own extensive studies which reported, inter alia, the identification of PCBs residues in seabirds from the Aleutian Islands, New Zealand, Iceland, Peru, Southern California, arid Green land, fish from the Aleutian Islands and Iceland, seabird eggs from the Antarctic and the South and North Atlantic Oceans, air over the North Atlantic Ocean, snow on the Antarctic Peninsula, and seawater from the Pacific Ocean off California. . PCBs are widely distributed in the en vironment in North America, having been found in fresh waters, river sedi ments, fish, birds, mammals, and human tissues, in addition to their occurrence in the marine environment described in the testimony of Dr. Young and Dr. Rise brough. . E. BIOACCUMULATION OF PCBS One of the most important environ mental properties of PCBs is their tend ency to be "bioaccumulated" or "biocon centrated" by aquatic organisms into their tissues to levels much higher than, in the ambient water. This property re sults from the high solubility of PCBs in lipids and their low solubility in water. There Is a further tendency for PCBs to be concentrated into animaLs to levels higher than in their food, a phenomenon known as "biomagniflcation." Within or ganisms. PCBs are further concentrated into certain areas, especially the fat. Fish can bioaccumulate PCBs directly from the water, in addition to uptake in the food, and in most cases direct uptake from water is more rapid and leads to much higher accumulation in the tissues. This uptake is Initially rapid, followed by a gradual decrease in the rate of uptake until a steady state is approached. The time required for approach to the steady state is from one day up to several months, depending on the size of the in vertebrate or fish. Although the steady state is sometimes described as an "equilibrium", there is no evidence in the record from long-term studies that aquatic organisms reach true equilibrium with PCBs in the water. Dr. Nisbet char acterized the steady state as "quasiequi librium" in which concentrations of PCBs hi the water and/or the fish change slowly. In one laboratory experiment PCB concentrations in fish tissue ap proached a steady state within 100 days but continued to rise slowly until the experiment was terminated at 250 days. In another study of lake trout of dif ferent ages taken from the same body of water, concentrations of PCBs increased steadily with age, rising from 1-2 ppm at the age of 1 year to about 20 ppm at the age of 11-12 years. In the "steady state" condition the concentrations of PCBs in the tissues of fish exposed to different concentrations in the water are proportional to the am bient water concentrations (although "hot spots", sediments and other factors may affect proportionality). It is possible to define a "bioaccumulation factor" as the ratio between concentrations of PCBs in the fish tissues and in the water. The bioaccumulation factor is independent of the ambient levels and is characteristic of the fish and the duration of the ex posure. The bioaccumulation factor is an operationally-defined ratio dependent on the circumstances of exposure. Bioaccumulation factors for PCBs in fish, measured in laboratory conditions, were fairly extensively reported in the Agency's criteria Document and in the testimony of a number of witnesses (in cluding one EIA witness). With only two exceptions, none of the experiments, however, extended for more than 42 days, and they thus represent only the initial uptake of PCBs and approach to steady state. The two exceptions were the 8month studies of fathead minnows con ducted by Drs. Nebeker, Veith and others, in which residues in the fish were 2-4 times higher at the end of the 8-month experiment than in fish sampled after 30 days. Thus, data for the experiments conducted for shorter periods underes timated the potential for bioaccumulatlon in the tested fish. In the 8-montli experiments described above, tire bioaccumulation factors meas ured at the end of 8 months varied be tween 32,000 and 274,000 for Aroclor 1242; 46,000 and 307,000 for Aroclor 1254: 60.000 and 120,000 for Aroclor 1248; and 160.000 and 270,000 for Aroclor 1260. The figure of 274,000 was discussed extensive ly in the record as it played an important role in the proposed standard-setting, and counsel for objectors (both environ mental groups and industries) objected to it. Environmental groups argued for a much higher rate of bioaccumulation, leaning heavily on field rather than lab oratory data; industry groups for a somewhat lower rate (for certain Aroclors) which is discussed infra. The 274.000 bioaccumulation rate was based upon the mean of 3 residue determina tions of male fish exposed to the lowest concentration (0.86 parts per billion) of Aroclor 1242. Although objectors repeat edly attempted to denigrate these meas urements, there is no reason to regard them as any less or more reliable than others obtained from these experiments. Although the mean figure for the six fish used in this test was reported by Dr. Nebeker as 274,000, Dr. Nisbet did testify that a scientifically meticulous averaging process would have yielded a figure of 345,000, and the average bioaccumulatio'n factor for four of the six was 447,000. Although all the experiments of bio accumulation indicated biological varia bility in storage of PCBs, even among fish raised in the same tank, this figure of 274,000 for the male fathead minnows was felt to be as reliable as any other in the record, and is derived from the only experiment involving long-term ex posure of any fish to Aroclor 1242. Short term exposures (up to 32 days) of other fish to Aroclor 1248. 1254 and 1260 pro duced estimates of bioaccumulation fac tors in the range of 15,000-71,000. Two experiments have been reported in which bioaccumulation of Aroclor 1016 by fish has been measured. In an experi ment conducted by Mr. David Hansen, pinfish exposed to Aroclor 1016 at con centrations between 0.8 and 13 parts per billion accumulated PCBs to levels up to 55.000 times the ambient concentration within 42 days, but the data dp not clear ly demonstrate that a steady state hadbeen reached. In an experiment con ducted by Dr. Gilman Veith, fathead minnows exposed to Aroclor 1016 for 30-32 days accumulated PCBs to levels up to 60,000 times those in the ambient water. The bioaccumulation factors in creased steadily between 10 and 32 days of exposure. This degree of bioaccumu lation is approximately half ' that re ported in fathead minnows exposed to Aroclor 1248 and 1260 in the same cir cumstances and for the same period of time. This is one of several pieces of evidence in the record which suggest that tri- and tetrachlorobiphenyls are stored in fish somewhat less efficiently than penta- and hexachlorobiphenyls. In comparable studies with sheepshead minnows, Aro clor 1254 was bioaccumulated to levels about twice as high as those of Aroclor 1016. However, comparable studies with pinfish found similar bioaccumulation factors for Aroclor 1016 and 1254. Other relevant data, including studies with pure isomers', are included in the Criteria Document. After reviewing all of the foregoing data. Dr. Nisbet concluded that "the differences in retention between tetraand higher chlorobiphenyls are small, no more than a factor of 2-3 in the circum stances of these experiments". EIA wit nesses Drs. Lauer and Mueller conceded FEDERAL rEGISTEP, VO*. 4?, NO. 22--WIOMESDAY, fEO'.UARY v -c\: y* oSNN3609^ STLCOPCB4097559 mo ^ RULES AND REGULATIONS that this was a fair summary of the concentrations In the whole fish--typi water, but also in food and sediments; at evidence. cally by a factor of about 3. This has least some fish continue to accumulate The only aquatic biologist who testi relevance In calculating safety factors PCBs over a period of years as they grow fied on behalf of the Industry objectors was Gerald J. Lauer, senior scientist and for human exposure or In evaluating risks to humans, but Is not found to be older and fatter. Moreover, PCBs are patchily distributed in the environment Director of Operations of a private con relevant In calculating the margin of and the levels in the fish may reflect sulting firm named Ecological Analysis, Inc., of Middletown, New York. He has safety for wild birds and mammals which eat whole fish. their integrated history of exposure as they have moved through natural waters, never actually measured bioaccumula tion of PCBs to fish and has had no Studies demonstrating bioaccumula tion of PCBs by aquatic invertebrates rather than strict equilibrium with the levels In the ambient waters where they personal experience with PCBs except to review some literature. N . were entered into the record, and showed that Invertebrates such as crabs and are caught. . Dr. Nisbet testified that in attempting Some scientists conducting bioassay shrimp absorb PCBs not only from water to predict the degree of exposure to experiments to determine toxicity or bio but also from contaminated food and PCBs of consumers of fish from natural accumulation report the "nominal" or sediments. Reported bioaccumulation waters, estimates of typical bioaccumu pre-determlned concentration levels factors range up to 47,000 in Daphnia lation factors obtained from field meas with which the water is dosed; some re mogna., 108,000 in scuds, 60,000 in snails, urements are more relevant than those port the actual measured concentrations 26,000 in shrimps, and 165,000 in the Obtained in the laboratory. While labo in the water; sometimes both figures are edible tissues of oysters. There is little ratory measurements made under con Teported. It is generally preferable to use the measured concentration because dur or no differentiation of lower and higher chlorobiphenyl homologs during uptake trolled conditions are precise and pro vide significant information, they do not ing tlie course of the tests PCBs tend to and storage by invertebrates; in fact, in constitute a good model of the situation some degree to adsorb to container walls, or settle out. Consequently the meas ured concentration is likely to be lower than the nominal concentration. The one study with a fresh-water crustacean, the tri- and -tetrachlorobiphenyls in Aroclor 1254 were differentially accumu lated by factors 2-8 times greater than in the field, including multiple routes of exposure, patchy distribution of PCBs, and lifetime exposures. No assumptions covering the circumstances are necessary use of the "measured" concentration is the hexa- and heptachlorobiphenyls'. to extrapolate from field measurements more likely to reflect the level to which The objectors introduced no evidence to predict the situation in the field. the organism v?as actually exposed, and whatsoever that would rebut, modify, or Dr. Nisbet pointed out that residues this is a critical piece of data in estab weaken the evidence entered into the of PCBs in wild fish, molluscs, and crus lishing bioaccumulation factors as well record by EPA witnesses, that both lower taceans are quite variable, representing as toxicity levels. and higher chlorinated biphenyls are bio bioaccumulation factors as low as 300, In his affidavit as originally filed in accumulated by high factors into the 000 to as high as 10 million, but testified these proceedings Dr. Lauer tabulated edible tissues of oysters and other that in his scientific judgment a "value some data on bioaccumulation using the aquatic invertebrates. of 3 million would be an appropriate fig "nominal" exposure levels. He then con The Criteria Document sets forth ex ure to use as a `typical' bioaccumulation cluded on cross-examination that if one tensive evidence that acquatic . orga factor" for predictive purposes. He speci is seeking to determine what the orga nisms, including fish, in natural waters fied that his figure of 3 million repre nism was actually exposed to during the frequently bioaccumulate PCBs to much sented his best judgment for penta- and bioassay test, one should measure the higher levels than have been measured hexachlorobiphenyls, -whereas a figure of actual concentration in the water. under controlled conditions of exposure 1 million would be his best estimate for Therefore, while on the stand Dr. Lauer in the laboratory. Tills evidence Includes, trir and tetrachlorobiphenyls. While em revised the presentation of data in his inter alia, bioaccumulation factors ex phasizing the variability in bioaccumula affidavit so as to recalculate bioaccu ceeding 470,000 for shrimps, 230,000 for tion factors, he stated "X do not think mulation factors for Aroclor 1016 based crabs, and 670,000 for fishes collected that a responsible, well-informed scien upon, measured water concentration. in Escambia Bay, Florida. Additional tist would question the evidence that bio Moreover, if one is making a com new data were provided in the testimony accumulation factors for this and other parison between the bioaccumulation factors for Aroclor 1016 and any of the more highly chlorinated Aroclors, of Dr. Risebrough, who reported meas urements of bioaccumulation of PCBs by oysters by factors ranging up to 650,000. chemicals in wild fish would frequently exceed those observed In laboratory ex periments conducted for only a few - the scientifically sound way to do this Although Dr. Nisbet expressed reser weeks."' - is to compare tests using the same spe vations in his prepared statement about Extensive data have been incorporated cies, the same life stage of that species; two superficially discrepant sets of data into the record on the intake, storage, and a similar exposure time. This from natural water, new data Introduced and excretion of PCBs in birds and mam principle was accepted by Dr. Lauer. during the hearing resolved these dis mals. Testimony in this proceeding Thus when Dr. Lauer drew a compari crepancies. In particular. Dr. Veith and focused upon the storage of PCBs in son of the relative bioconcentration fac Dr. Risebrough reported measurements mammalian tissue as a putative measure tors of Aroclors 1254 and 1016, he used of PCB levels in the water of Lake On of hazard. Humans appear to retain the data presented by Hansen involving tario. Dr. Veith's data showed the con PCBs in their tissues more efficiently adult sheepshead minnows, wherein each centrations to be" less than 6 parts per than any other mammals that have been group of test organisms was exposed for trillion, while Dr. Risebrough presented studied to date. Insofar as the tissue 28 days. In his affidavit, using nominal precise measurements of concentrations levels that have been sampled represent concentrations, he found a concentration In two water samples in the range of the quantities of PCBs that are circulat factor for Aroclor 1254 of 23,000 and for 2.9-3.4 parts per billion. Relating these ing within the organism, with consequent 1016 of 8,000 or a 2.8 to 1 ratio. At the water concentrations to reports of PCB exposure of critical target organs to hearing, during cross-examination, he levels In fish from the lake ranging up PCBs, this Implies that for a given testified further that if one were to to 30 ppm (0.74-17 ppm in edible tissue dietary concentration humans will have compute the respective bioaccumulation of various species), these data suggest tissue levels up to 10 or more times those factors based upon actual measured con bioaccumulat.ion factors In the range of of other experimental animals. centrations in the water, the average fac 1-10 million. Dr. Nisbet testified that the Although the human population is tor for 1254 would be approximately data of Drs. Veith and Risebrough "have widely exposed to tri- and tetrachlorobi 50,000 and that for 1016 it would be ap cleared up the last two remaining sub phenyls as a result of their widespread proximately 24,000. This would indicate stantial pieces of evidence which have distribution in fish, tri- and tctrachlorothat the bioaccumulation factor for Aro cast doubt upon that conclusion * * biphenyls appear to be comparatively clor 1254 is approximately twice that Several reasons have been given as to poorly represented in human fat sam of Aroclor 1016. . why wild fish should bio-accaumulate ples. EIA witness Dr. Wolfgang Mueller Dr. Ni.sbct testified that the concen PCBs to a greater degree than experi attempted to argue that lack of storage trations of PCBs in the edible tissue of mentally exposed fish In the laboratory. of tetrachlorobiphenyls implies a lack . fish were usually lower than the average Wild fish are exposed to PCBs not only in of toxic effects. However, in fact, it is ". ' - ' FEDERAL REGISTER, VOL. 45, NO. 22--WEDNESDAY, FEBRUARY 2, 1977 DSW 360942 yy '-rX- ': STLCOPCB4097560 RULES AND REGULATIONS 6541 exposure'rather than storage that Is and 1242 are very similar in molecular to one hundred times less toxic than the significant in determining the degree of and isomeric constitution, the most im more chlorinated Aroclors, e.g., Aroclor hazard. When asked to explain the sig portant difference being that 1016 con 1054 [sic]" relies solely on an article by nificance of human exposure to tetra- tains only 1 percent of pentachlorobi- David Hansen entitled "Effects of Aroc chlorobiphenyls, Dr. Nisbet stated that phenyls while 1242 contains 8 percent. lor 1016 on Embryos, Pry, Juveniles, and "the significance is that after they are Aroclors 1016, 1242 and 1254 contain 21,' Adults of Sheepshead Minnors (Cyvrin- .exposed, the tetrachlorobiphenyls are 25 and 21 percent respectively of tetra odon variegatus)" (1975). In fact the circulated throughout the body [in] the chlorobiphenyls; tetrachlorobiphenyls referenced Hansen study shows that al hlood and therefore the various target have been utilized in a number of stud though the toxicity of Aroclor 1016 is iorgans which they might affect within ies discussed in the findings above. In substantially less than that for 1254 for the human body are exposed to them". addition, the constitution of PCB mix newly hatched fry, the toxicity of Aroc For example, many of the studies of the tures changes after they are released lor 1016 is comparable to that of 1242 and toxic effects of PCBs show effects on the into the environment, so that environ 1254 for all other life stages. Thus Han liver of mammals. - mental residues usually do not corre sen in this article gave the following With respect, to the industry position spond to commercial mixtures. In their summary with respect to 1016: on accumulation tendencies (presented in the context of argument for different effort to have the Agency carve out spe cial standards for 1016 and 1242, EIA In the laboratory, however. It (Aroclor 1016) is as acutely toxic to oysters, brown standards for certain Aroclors, which is and Westinghouse have ignored these shrimp (Penaeus aztecus) and pinfish as discussed below), Dr. Lauer testified that critical characteristics of PCBs. Aroclor 1242 and as toxic to oysters and Aroclor 1016 has been shown to bioaccu mulate by at least a factor of 73,000 based upon measured concentrations in laboratory tests. His evidence indicates that Aroclor 1016 accumulates at a fac tor half to two-thirds that of the highly chlorinated Aroclor 1254. He conceded that the bioaccumulation factor of fish in the Hudson River, where Aroclor 1016 is discharged from the General Electric Corporation capacitor plants, could be as high as 1 million based upon levels found in water and in fish. Based on Dr. Lauer's own testimony, there is no ground for the assertion by EIA and Westinghouse that Aroclor 1016 will not bioaccumulate at factors above 50,000. Even using labora tory figures alone which were discussed by Dr. Lauer, the highest bioaccumula tion figure he discussed for Aroclor 1254 was 307,000. Using the ratio between 1254 and 1016 of 2 to 1 which he de scribed in his testimony, this would sug gest a bioaccumulation potential for 1016 of over 150,000; using the 3 to 2 ratio suggested in the Westinghouse brief, a bioaccumulation potential of over 200,000 would result. As mentioned, tetrachlorobiphenyls are important elements of 1016 and 1242; tetrachlorobiphenyls are persistent and hardly degraded at all by bacteria. In an experiment in which 1016 was incu bated with activated sludge, 14 days* in cubation had little effect on the tetra chlorobiphenyls and other higher com ponents. While pentachlorobiphenyls and higher CBs are taken up and stored by fish and other aquatic organisms more efficiently than trichlorobipfienyls and lower CBs, differences in retention be tween tetrachlorobiphenyls and higher chlorobiphenyls are small, no more than a factor of two or three. Although most environmental residues of PCBs are in the form of pentachlorobiphenyls and higher CBs, trichlorobiphenyls and tet rachlorobiphenyls are widely stored in fish in the U.S. As explained elsewhere herein exposure to tetrachlorobiphenyls is harmful (even if they are stored less efficiently than higher chlorobiphenyls) because after ingestion, the tetrachloro biphenyls are circulated through the body in the blood, with consequent exposure to critical target organs. Expensive data on the toxicity of pinfish as Aroclor 1254 (Hansen, Parrish and Forrester, 1974). Its delayed toxicity to pin fish in exposures lasting 14 or more days Is similar to that found with Aroclor 1254 (Hansen, Parrish, and Forrester, 1974). Dr. Nisbet, on cross-examination, testi fied to the same effect. In reaching his conclusion. Dr. Lauer apparently over looked the additional studies, cited above, which showed adverse effects from Aroc lors 1016 and 1242 at low levels. There Is no sound basis for concluding that Aroclor 1016 is significantly less effective than the higher chlorinated PCB mixtures in causing critical toxic effects in mammals. There are several reasons why this is so; (a) Jn cases where toxicity data for Aroclor 1016 are not available, it is rea sonable to estimate the toxicity of Aro clor 1016 by extrapolation from the tox icity of Aroclor 1242, since the two mixtures are very similar in constitution. If a toxic effect were caused by higher chlorinated compounds (not present or. present only at low levels in Aroclor 1016), it would be expected to be mani fested by a difference in toxicity between Aroclors 1242 and 1254. Aroclor 1242 has T. SEPARATE CRITERIA AND STANDARDS FOR Aroclor 1016 to aquatic organisms were 8 percent pentachlorobiphenyls versus CERTAIN AROCLORS UNWARRANTED incorporated into the record in the Cri 48 percent for Aroclor 1254, and 1 percent . Both EIA and Westinghouse urge the establishment of separate, less stringent standards for Aroclor 1016, and West inghouse suggests a separate standard for Aroclor 1242 as well. This contention has received considerable attention in Agency testimony and evidence. Much of the evidence of the harmful properties of PCBs has been established by reference to experiments and data- gathering involving Aroclors 1016 and 1242. All PCB mixtures currently in use, Including Aroclors 1016 and 1242. are capable of inducing severe toxic effects at low levels, with only minor variations In behavior in some instances; there is therefore not sufficient Justification for establishing separate standards for vari ous mixtures. ' All PCBs are mixtures of biphenyi molecules which have varying numbers of chlorine atoms substituted in place of hydrogen atoms at certain locations on the molecules. The mixtures presently marketed by Monsanto--Aroclors 1221, 1016, 1242 and 1254--are four out of several hundred possible mixtures. With teria Document and in the testimony of two EPA expert witnesses. There is little significant difference between the toxicities of 1016 and 1242, 1248 and 1254 to aquatic organisms. Only three reported studies suggest any appreciable difference and the results are inconclusive: (a) Aroclor 1016 was about 8 times more toxic than Aroclor 1248 in an acute toxicity test with channel catfish. (b) In chronic bioassays with pinfish, Aroclor 1016 was somewhat less toxic than Aroclor 1254. (c) In bioassays with sheepshead min nows. Aroclor 1016 appeared signifi cantly less toxic to the eggs than Aroclor 1254. However, It Is questionable whether this difference (observed in laboratory tests) would be relevant to field condi tions, because another report showed hatching failure in rainbow trout eggs containing PCB residues similar to Aroc lor 1242 at concentrations of only about 2 to 7 ppm. The testimony of Dr. Lauer that "the more recent and, for the most part, the more reliable data indicate that Aroc hexachlorobiphenyls versus 23 percent for Aroclor 1254. .Yet Aroclor 1254 haa not been demonstrated to be significantly more toxic than Aroclor 1242. (b) The critical toxic effects in mam mals relied upon by-the Agency in for mulating its ambient water criterion are relevant to Aroclor 1016, as follows: (1) Dr. Robert Ringer noted reproduc tive failure in mink at dietary levels of Aroclor 1016 at 2 ppm, only a slightly higher dose than the dietary level of 1 ppm Aroclor 1254 which he found to be toxic for the same conditions, or the dietary level of 0.64 ppm which platonow and Karstad found using Aroclor 1254. (2) Increased liver weight in young rats was found by Iverson after dosage at 1 mg/kg of Aroclor 1016 and 1242 per day (comparable to 8 ppm in the diet) for 21 days. (3) Although no studies are known to have been conducted on dogs with Aro clor 1016, a high incidence of stomach nodules and ulcerations have been re ported in dogs fed 10 and 100 ppm Aroclor 1242. (4) Dr. Wilbur McNulty found rhesus respect to these mixtures. Aroclors 1016 lor 1016 ranges from slightly less toxic monkey mortality occurrence In eight FEDERAL REGISTER, VOL. 42, NO. 22--WEDNESDAY, FEBRUARY 2, 1977 DSW 360943 STLCOPCB4097561 6542 - RULES AND REGULATIONS montlis from exposure to 3.0 ppm of clor 1016 may not represent detoxifica sue of rats to be almost double those for Aroclor 1242 and to 10 ppm in shorter tion because the lower biphenyls may 1242. -. periods. In light of studies performed on form metabolites which can lead to In Contrary to EIA's claim In its brief, monkeys with both Aroclors 1242 and creased toxic effects. One experiment in the Iverson study has found both 1010 1248, monkeys appeared to be more sen dicated that the acute toxicity of the and 1242 to cause significant enzyme in sitive to Aroclor 1242, the mixture most primary metabolite of a tetrachlorobl- duction in male rats after 21 days at similar to Aroclor 1016. . phenyl isomer was five times higher than daily dose levels as low as an equivalent (5) Increased activity of hepatic mi that of the parent compound. There is of 8 ppm. Dr. Harry Gelboin, EPA's ex crosomal enzymes has been reported by ample other evidence In the record that pert witness on enzyme Induction, testi .Iverson in rats treated with Aroclor 1016 metabolism of tetrachlorobiphcnyls pro fied that the Iverson study demonstrat at dosage levels as low as 1 mg/kg per ceeds via toxic intermediates, including ed that Aroclors 1242 and 1016 were day. . . . arene oxide intermediates which have equally potent as enzyme inducers and (C) The effects on liver weight and been implicated as a causative agent in that the twenty percent increase in en enzyme activity for Aroclor 1016 were toxic, carcinogenic and mutagenic effects. zyme induction over controls found for similar to those observed for Aroclor 1242 in the comparative study performed by Iverson on male rats, and were at least comparable to those observed in other EIA claims in its post-hearing brief that 99 percent of Aroclor 1016 consists of mono-, di-, tri- and tetrachlorobiphenyLs which are rapidly metabolized with male rats could be very significant oyer an extended period of time. Dr. Gelboin further noted that based on his studies with enzyme Inducers of the same class experiments with Aroclors 1254 and 12C0. (7) Observations as to the similar little accumulation. As previously stated, the record establishes that trichlorobi- as PCBs, In virtually all cases, a com pound which was an enzyme inducer in enzyme inducing effects of Aroclors 1016 and 1242 warrant a conclusion that since phenyls are metabolized much more slowly than mono- and dichlorobiphe- rats and mice was also found to be an enzyme inducer in primate or human 0.5 ppm of Aroclor 1242 considerably in nyls and higher CBs (including tetra- cells. creased rat microsomal enzyme activity chlorobiphenyls) hardly at all. Tri- and EIA attempted to refute the findings . after four weeks, similar effects can be tetrachlorobiphenyls are widely stored from the Iverson study with "two similar expected from similar' low doses of in fish throughout the U.S. On cross studies" in which no similar effects were Aroclor 1016. The degree of increased ac examination at the hearing both of found. The first study was one conducted tivity of various enzymes to be protected ElA's witnesses. Dr. Lauer and Dr. Muel for only 6 days by Bickers, et al. As was from such a dosage would be between 10 ler, were shown this data," and each tes pointed out In the Criteria Document, the and 60 percent. Thus, it appears that tified that they had no reason to dis disparity in results was probably due to chronic exposure to low dose levels of agree with it. Dr. Lauer also testified the more extended dosage regime in the Aroclor 1016 is likely to cause an effect that Aroclor 1016 has been shown to bio Iverson experiment. The second study by on enzyme activity in the human liver. accumulate by at least a factor of 73,300, Goldstein, et al. was performed on female . (8) The results of the Industrial Bio based upon conservative laboratory tests, rats. Dr. Gelboin testified that male rats Test rat experiment did not suggest a and he conceded that the bioaccumula would be expected to be more responsive marked difference between the effects of tion factor for fish in the Hudson River to enzyme inducers than female rats. Aroclors 1242, 1254 and 1260 In inducing (where Aroclor 1016 is discharged from Nevertheless, Goldstein noted marked in pathological changes in the livers of rats. General Electric Corporation plants) creases in liver weight and all drug me (9) Tumors have been produced in rats treated with Aroclor 1242. Nodular hyperplasia, a term now generally under stood to refer to neoplastic changes, has been reported in rats treated with Aro clor 1242 at only 10 ppm. (c) Only three experiments have been reported in the record which suggest differences in toxicity to mammals be tween Aroclors 1016 and 1242: (1) Mueller, the EIA witness, pointed out differences in the pathological changes induced in rat livers by expo sure to Aroclors 1016 and 1242, as sum marized in Tables m.9.4 and m.9.5 in the Criteria Document. However, Dr. Kimbrough, who conducted the experi ment in question, stated that the differ ences were minor and that the small sizes of the sample groups precluded linn conclusions. . (2) An experiment has shown some apparent differences in the induction of liver enzymes and porphyria In rats by Aroclors 1016 and 1242. However, the rats were examined only after 7 days and 6 months of exposure, and because of differences In the temporal course of in duction. it appeared that finn conclu sions could not be drawn. (3) Aroclor 1016 markedly reduced the gonad weights of female rats after 90 could be as high as 1 million based upon levels found in water and in fish. Westinghouse alleges that two com parison studies conducted by Dr. Renate Kimbrough on rats show that lower chlorinated PCB mixtures are less liepa- totoxic than the higher chlorinated mix tures. With respect to Dr. Kimbrough's comparative study of the effects of Aro clors 1016 and 1242 on male rats, Dr. Mueller conceded on cross-examination that hepatotoxic effects more serious than enlarged hepatocytes were noted for Aroclor 1016 at other exposure peri ods, as well as at 8 months. _ Contrary to Dr. Mueller's conclusions, the hepatotoxic effects found for male rats in Dr. Kimbrough's 1016/1242 study were not substantially different from those found for male rats in their earlier study with Aroclors 1254 and 1260. Dr. Mueller conceded that in fact vacuolated cytoplasm, which admittedly referred to the same phenomenon as an increase in lipids, was found by Dr. Kimbrough in both studies, and that the absence of adenoflbrosis in the 1016/1242 study did not create a significant difference be tween the two studies once one fairly compared the results for male rats at the same dose levels and for the same time period. . tabolizing systems from exposure to Aro clor 1242. In the beginning of the study Aroclor 1242 has more severe effects than Aroclor 1016. However, after six months' exposure, the effects of Aroclor 1016 were much-more-similar to those of Aroclor' 1242. EIA erroneously argued that Dr. Rob ert Ringer in his Aroclor 1016 tests on mink found no significant adverse effects at or below 25 ppm. In fact he found im pairment of reproductive performance in the females at levels as low as 2 ppm. Al though no statistical analysis has been performed on the results in Table 1 to his Exhibit F, Dr. Ringer testified that looking at the table as a whole it was sig nificant to note that, as dosage increase'1, poorer reproduction resulted--the num ber of females that whelped out of those that were mated was reduced, the num ber of kits bom alive decreased, the aver age number of kits bom per mated fe male decreased and the number of kits alive at four weeks of age also decreased. Dr. Ringer testified that results from an earlier unpublished study witli Aroclor 1016 In which no adverse effects were found at the 2 ppm level did not draw Into question his more recent conclusions. Since adverse effects were noted hi at least one study, 2 ppm cannot be con sidered a "no effect'' level. days' exposure to 30 and 100 ppm In the diet, whereas under the same conditions Aroclor 1242,1254, and 1260 did not. Thus in this case Aroclor 1016 produced nil ad verse effect not produced by the oilier mixtures. Finally, as to a comparison between Aroclors 1016 and 1242, Dr. Mueller was shown to be In error when he concluded that Aroclor 1242 would be expected to be retained to much higher levels of Aro In addition to the Information set , ' forth above, derived from laboratory ex periments, there are Important data de rived from field observations which fur ther support the proposition that It would be Inappropriate to establish separate . The biological degradability of- the clor 1016. Dr. Kimbrough found residue and different criteria of effluent stand lower chlorinated components of Ato- levels of Aroclor 1016 In the adiiiose tis ards for different commercial mixtures. FEDERAL REGISTER, VOL. 47, NO. 22--WEDNESDAY, FEBRUARY 2, 1977 360944 osnN STLCOPCB4097562 i- ' RULES AND REGULATIONS . 6543 The constitution of commercial mixtures exist as a vapor, or gas, much like the at the discharge point from an industrial of PCBs changes as they pass through the formation of water vapor or steam when plant the lower limit of detection may environment, so that plants, animals and water is heated. The gas chromatograph be sacrificed in the process of removing humans are exposed to mixtures whose is an instrument which consists of an possible interferences." Thus, "experi constitution differs from those whose oven, a long thin tube called a column, ence with effluents from capacitor and toxicity has been tested in laboratory ex a gas regulator which permits a carrier transformer facilities indicates * * periments. gas such as nitrogen to flow steadily detection limits of- approximately 0.1 The record contains ample evidence to through the column, and a detector micrograms per liter should be attainable sustain the Agency's original conclusion which detects when a chemical other on a consistent basis for 1 gallon effluent that there is no justification for setting than the nitrogen carrier exists from samples." separate and more relaxed standards for the column. When mixtures of chemicals Dr. Thomas O. Munson, a biochemist "Aroclors 1016 and 1242. Indeed, in light are introduced into the column, each employed in EPA's Region III Field Of of the statutory mandate to provide an chemical will, depending on its boiling fice at Annapolis. Maryland, and who ' "ample margin of safety", any doubts point, separate and elute (escape) from from 1969 through May, 1976, was em in this area should be resolved in favor of the column individually at different ployed by Westinghouse Electric Com protection, and against making distinc times. Each time a chemical thus es pany (an objector in these proceedings) tions among Aroclors. capes from the column, the detector pro at its Westinghouse Ocean Research duces a peak on a chart paper recorder. Laboratory, testified to the same effect C. PRESENCE OF TOXIC IMPURITIES IN PCBS The resulting tracing on the chart paper as Dr. Veith with respect to use of the Most commercial PCB mixtures con showing a peak for each chemical sepa EPA analytical method. In particular, tain small quantities of polychlorinated rated is called a "gas chromatogram." he testified that: "With a sufficient dibenzofurans (PCDFs) as impurities. The intensity of the peak on the chart amount of care, most analysts familiar PCDF content in PCB mixtures is sub recorded is proportional to the quantity with the techniques of determining ject to considerable variation and un of chemical placed on the column. Con chlorinated pesticides should be able to certainty. FCDFs can be formed by pho sequently gas chromatography permits measure PCBs to about 0.1 parts per tochemical reactions in the environment the analyst to separate mixtures of many billion (ppb) in most industrial effluents. in sunlight and as a result of metabo chemicals and determine the indentity At the Annapolis Field Office of EPA, the lism. PCDFs are potentially much more and quantity of each in the mixture. analysts routinely measure PCBs in in toxic than the parent CB, but it is un By use qf gas chromatography, it is pos dustrial effluent with a detection limit of likely that the low levels of PCDFs pres sible to identify the various PCB isomers about 0.05 ppb using this method." In ent in PCBs are a significant factor in present in a sample, and thereby to iden those samples, many of which were "very the mixtures' high toxicity in rhesus monkeys, the valuable animal model for tify which of the commercial mixtures, or Aroclors, appear to be present, as well oily and contained large amounts of in terfering sulfur material," Dr. Munson human poisoning by PCBs. In any event, as the quantity thereof present in the utilized a modification of the standard it appears impossible to disentangle the sample. This method may be used to EPA procedure as a result of which he toxic effects of PCDFs from those of PCBs. In setting criteria and standards for PCBs, it is necessary to recognize analyze for PCBs in water, fish or animal tissue, sediments, or other substances. The basic EPA method document sug was able to measure PCBs at a "working level" of 1 part per trillion (ppt) with a detection limit of 0.1 ppt. The modifica that the mixtures found in the environ ment may be more (or less) toxic than gests a detection limit of approximately 1 microgram per liter using a sample of tions utilized to achieve this are increas ing the sample size to 4 liters, extraction the commercial products studied in the laboratory. This adds an additional de 100 milliliters to 1,000 milliliters. How ever, the method can readily be adapted of the sample directly in the sample col lection vessel, and minimization of con gree of uncertainty to the assessment of to larger sample volumes to provide rea tact with glassware during the clean-up potential environmental hazards, mak sonable reliability at much lower water procedure... Dr. Munson noted that "it ing it inappropriate to set different standards for different Aroclor mixtures, and difficult to establish definitive stand ards above zero. . . H. MONITORING CAPABILITY concentrations. The EPA method is flexible and pro vides a basic framework for an analyti cal chemist. This framework allows suf ficient flexibility so that he can make minor modifications within the proce may be that not all laboratories, given their large volume of business and moni toring requirements of numerous efflu ents for a variety of substances, can routinely achieve these results, but an experienced analyst given sufficient time In its proposed standards' for PCB dure to tailor such things as sample size, to take the necessary steps" which Dr. manufacturers, electrical capacitor man extraction, and clean-up procedure to Munson described "should be able to ufacturers, and electrical transformer the particular circumstances and objec achieve or closely approach these levels." manufacturers, the Agency specified that tives of the analysis. Both EIA and Westinghouse argue that the acceptable analytical method is that Dr. Gilman D. Veith, a research ana there does not exist reliable measuring identified in Part 136 of Title 40 of the lytical chemist at the EPA Environmen and analytical capability for PCBs at Code of Federal Regulations, "except tal Research Laboratory, Duluth, testi and lielow one microgram per liter, so that a one liter sample size is required fied that by increasing the sample size, that it would be improper to establish to increase analytical sensitivity." (Sec one can enhance the sensitivity (or detec standards below at least 20 micrograms tion 129.105 (b) (2), (c) (2), and (d) (2).) tion limits) of the process. Thus, using per liter. 40 CFR Part 136 includes express pro the standard EPA method and a 1 liter However, they did not at the hearing vision for application for and approval sample size would provide a detection present any competent, credible evidence of alternate test procedures. (40 CFR limit of 0.1 micrograms per liter. Using to support this proposition or to under 136.4 and 136.5, as amended, 41 FR a sample size of 1 gallon, which is ap cut the validity of the approved EPA 62780.) proximately 4 liters, will provide a detec method and the testimony of Drs. Veith The official EPA analytical method for tion limit of 0.025 micrograms per liter. and Munson. EIA presented two wit sampling and analyzing commercial PCB The detection limit can be further re nesses on the subject, only one of whom mixtures, as identified in 40 CFR Part duced by collecting 5 gallon samples of had any first-hand experience in con 136, is contained in a document entitled water and/or by concentrating the final ducting analyses for PCBs. "Method for Polychlorinated Biphenyls extract from 10 milliliters to a smaller The first EIA witness was Dr. Eunice (PCBs) In Industrial Effluents." The volume. Dr. Veith testified further that M. Moore, Director of Research and basic methodology set forth therein is for natural waters such as lakes and Development for the Electrical Utilities the standard analytical method cur streams, cleanup of sample is minimal Company of LaSalle, Illinois. Dr. Moore rently in use for the detection and anal and a PCB detection limit of 0.01 micro does not do tests or analyses and has ysis of chlorinated organic compounds, grams per liter is commonly used. He never conducted an analysis of an indus Including PCBs, namely gas cliromatog- added that: "however, when an effluent trial effluent for PCBs. In October 197G. rapliy. Gas chromatography is the sci sample containing comparatively large Dr. Moore was asked by EIA to contact ence of separating chemicals which can amounts of chemicals other than PCBs various capacitor manufacturers and be heated to the point at which they is analyzed, such as sometimes is found have them send effluent samples to two FEDERAL REGISTER, VOL. 42, NO. 22--WEDNESDAY, FEBRUARY 2, 1977 .- oSW 360945 \ STLCOPCB4097563 6544 ' .. - or more laboratories of their choice to . determine the extent to which similar analytical results were obtained by these laboratories. The laboratories selected were four EPA Regional laboratories, six commercial laboratories, and two com pany laboratories. Dr. Moore testified with respect to this survey that her only information on the quality control of the commercial and company laboratories was conversations with the companies. She made no independent effort to as sure herself of good quality except at the Warf Institute. She did not know what analytical methods were, followed by the various laboratories. Most of the sam ple sizes were 1 gallon, but some were 1 liter. Most of the samples were com posite, but at least one was not. None of the samples were replicate samples (2 samples taken at the same place and time). She did not know whether the divisions of the 1 gallon samples among the laboratories were even. Many figures in the report of the survey show levels substantially above the solubility levels of PCBs, which is 250 micrograms per liter and below. She conceded that when the PCB volume in the sample is above the solubility level, this makes the analytical results unreliable, which might well explain the disparity of re sults between the laboratories for sam ples in excess of 200 parts per billion. No statistical analysis was done of the results. Although the results reported by Dr. Moore do show some disparities in the results obtained by the various labora tories, all of the above-mentioned limita tions raiset serious questions about the reliability of the data set forth therein. Moreover, Dr. Moore testified that she was not aware of any efforts by EIA to find a laboratory which would give more reliable results following the testing set forth in her report and so far as she knows no one from EIA has contacted EPA's Environmental Monitoring and Support Laboratory in Cincinnati for guidance, nor has anyone gone back to look at the various laboratories to find out why the results were disparate. The second witness presented by EIA on analytical techniques and measuring capability was Dr. James Laubscher of the Woodson-Tenent Laboratories of Memphis, Tennessee. The thrust of his testimony is set forth in paragraph 6 of his affidavit: ' I do not believe that my laboratory can produce accurate test results of PCB levels In Industrial effluent water at 1 part per bil lion at the pipe. This level Is too low for reliable testing. . Testimony elicited on cross-examination of Dr. Laubscher offers illuminating evi dence concerning his professed lnabliity. The principal evidence offered by Dr. Laubscher to support his contention that different laboratories get varying results when analyzing similar samples of PCBs is a round robin test conducted by Mon santo Industrial Chemical Company nmong twelve laboratories using a meth od developed and published by the American Society for Testing and Mate rials, referred to as ASTM D-3304. RULES AND REGULATIONS Woodson-Tenent Is laboratory "K" on the Monsanto round robin report. The results from laboratory K "were reject ed when it was learned that one critical step of the method was omitted." Dr. Laubscher stated that in performing his work one of Woodson-Tenent's labora tory technicians had not extracted the sample properly, which was "a major deviation from the accepted procedure." Dr. Laubscher, apart from the work of his laboratory, had no first hand knowledge of any other aspects of this testing. He had no idea what amount of time elapsed between the taking of the samples and the analyzing of them, or the number of transfers of the sample from vessel to vessel. He did not know the identity of the laboratories doing the tests, other than his own. He did not know whether the samples were repli cate or split, or who prepared them, or how they were prepared. Although most of the results actually range within 10 to 25 percent of the mean, he has no basis for independently validating any of the data reported in the Monsanto round robin test. Dr. Laubscher testified that Wood son-Tenent does not use the EPA meth od for sampling and analysis. Moreover he has rejected the ASTM method used in the Monsanto round robin as unsatis factory because of the amount of glass ware involved. He testified that sidewall adsorption to glassware is why one must avoid multiple glassware exposure, for such sidewall adsorption results in "dra matically reduced levels" in the analysis, which in turn would reduce his confi dence in the results obtained by any such method. Woodson-Tenent uses in stead an analytical method developed ten years ago by someone.named "Bill" in the National Center for Communica ble Diseases. Although he has used this method to report to commercial custom ers PCB analysis accurate to 2 decimal places in micrograms per liter (i.e., to 100th of a-microgram per liter), he gave conflicting testimony as to his degree of confidence in the reliability of these re suits. Woodson-Tenent's analytical perform ance over the last several years has not been impressive. Two years ago they sub mitted analytical test results on three chlorinated organic compounds, aldrin, dieldrin, and DDT, to EPA's Cincinnati laboratory, using a gas chromatography analytical technique which is essentially the same as that used for PCBs. The re sults of Woodson-Tenent's analysis as compared with the actual spiked values placed hr the samples by the EPA Cin cinnati laboratory indicate a very sub stantial differente between the values reported by Woodson-Tenent and the values actually present in tire samples. Woodson-'I'enent also did some analyses on Hudson River water in connection with the proceedings by the State of New York against tire General Electric capac itor plants. However, the laboratory in correctly used the wrong size injection syringe, which allowed tire needle through which the sample is Injected to the clrromatograph to be plugged up, so that ho sample was injected Into the \: chromatograph, and thereby "botched up" the job. Of the "over 5,000 analyses" for PCBs which Dr. Laubscher stated in his affi davit that he has "personally conducted", most of these have in fact been per formed by others under his general di rection, and only three or four have actual^' been conducted by him on the effluents from capacitor manufacturers. He testified that on drinking water sam ples he could reach detection levels of 75-100 ppt, but offered no explanation as to why he apparently could not achieve anything close to these levels when measuring in industrial effluents-- particularly in light of his testimony that there is not a lot of interference in the extracts from samples taken from capacitor plant effluent. No evidence was presented which sug gested that a commercial laboratory, using the EPA method and a degree of care comparable to that described by Drs. Veith and Munson, could not achieve detection levels comparable to theirs. For point sources subject to a prohibi tion on discharge of PCBs in their efflu ent, while it is reasonable to expect im provement, existing methods are ade quate to monitor for compliance. ; I. INDUSTRYWIDE STANDARDS Both EIA and Westinghouse contend that the Administrator is without au thority to establish national or indus trywide toxic pollutant effluent stand ards for PCBs, but may proceed under section 307 (a) only on a plant-by-plant basis. This argument is contrary to both the law and the evidence. Section 307(a)(5) expressly provides as follows:"' . . When proposing or promulgating any efflu ent standard (or prohibition) under this Sec tion, tho Administrator shall designate the category or categories of sources to which the effluent standards (or prohibition) 6liall apply. Any disposal of dredged material may be included in such a category of sources after consultation with the Secretary of the Army. Thus the effluent standards by law are to be applicable to a "category or cate gories of sources," and are not to be set on a plant-by-plant basis. EIA quite incorrectly asserts that Dr. William Brungs testified that there is a need for `local regulation" and that it is "difficult to assess the environmental implications of a given discharge by means of a national effluent standard." In fact. Dr. Brungs' testimony was that it is appropraite to establish mixing zones on a site-by-site basis; nowhere does he suggest that it would be inappropriate to establish a toxic pollutant effluent stand ard which would be applicable on a na tional, or industrywide, basis. EIA also asserts that "the record con tains no specific information concerning the bodies of water into which the capac itor and transformer plants affected by the proposed regulation discharge." This again is quite Incorrect. Dr. Gilman Veltli presented considerable informa tion showing that PCB concentrations in the ambient waters and fish arc con , ; FEDERAL REGISTER, VOL 42, NO. 22---WEDNESDAY, FEBRUARY 2, 1977 DSW 360946 STLCOPCB4097564 RULES AND REGULATIONS 6545 sistently very high in areas where plants which manufacture PCBs or PCB-filled transformers or capacitors are or have been located. There are some compounds which arc so toxic, persistent, and mobile that they should be regulated through a national or industrywide standard, including, where justified, a prohibition. Section 307(a) confers this express authority on the Administrator. As the evidence in this proceeding abundantly demon strates, it is hard to imagine a compound for which regulation on a national basis is more appropriate, in.view of the ex traordinary persistence and mobility of PCBs. J. SUBSTITUTE MATERIALS Although neither the Agency's pro posed standards nor my decision here were based upon the availability of sub stitutes for PCBs for use in transformers and capacitors, evidence indicates there are some substitutes presently available, and industry is proceeding to develop others. All transformers used in the electrical industry have provision for cooling, based on either gaseous or liquid cool ant, because the efficiency of a trans former is maximized if it is kept at a low operating temperature. Tile coolants in common use today are mineral oil and PCBs for liquid cooled transformers, and air and gas for dry-type transformers. PCB-cooled transformers account for about 5 percent of all electrical trans formers in service. The PCB coolant in these transformers is a mixture of 60 to 70 percent PCBs and 40 to 30 percent trichlorobenzene and is commonly known by the generic term "askarel." The PCBs currently used in these mix tures are Aroclor 1242 and Aroclor 1254. Askarels produce highly corrosive hydrochloric acid when arcing takes place and cost about eight times as much as mineral oil on a volume basis. For these reasons, askarel-filled transform ers are only used where considerations of fire safety, reliability, availability, and cost make such a unit preferable to an oil-filled or a dry-type transformer. They are also limited by the dielectric strength of the liquid to ratings below 69,000 volts. , Oil-filled and dry-type transformers are currently used in 95 percent of all applications and could, with proper en gineering design, be used to replace most of the remaining askarel-filled units. Mineral oil-filled transformers are the same size as the askarel units, are con siderably lighter in weight, and have somewhat better heat transfer charac teristics. Moreover, an electrical arc in mineral- oil results in non-corrosive breakdown products. Furthermore, askarel-filled transformers cost about 1.3 times as much as oil-filled units of the same capacity. Thus the oil-filled trans formers actually have a number of ad vantages over those which use PCBs. The major disadvantage to mineral oil is its flammability. However, the issue of flammability only becomes important where the distribution transformer must be buried, as in many urban applications,. or located close to, within or on the roof In situations where askarel-filled of the building which it serves. Oil-filled transformers are used (in hazardous lo transformers are used in almost all power cations) , low viscosity silicone fluids such transformer applications, for most sub as polydimethyl siloxane could be used station distribution applications where as substitutes. Little information is the high voltage from the transmission available concerning the fate of silicones lines is reduced to 12.8 kilovolts for local in the environment or the toxicity of distribution, and for most rural pole- their breakdown products. Extended mounted transformers which reduce the feeding studies Revealed polydimethyl voltage to 220 volts. For those applica siloxane to be relatively non-toxic. No tions, the transformers must be suitably tendancy for bioaccumulation occurred isolated from flammable structures or the in experiments. Known chemisty sug structures must be suitably safeguarded gests that environmental degradation against fires. would occur through sunlight exposure. For certain uses, air-cooled or gas- Dow Corning has indicated that its pres filled transformers are employed, which ent domestic capacity for polydimethyl do not require ackarels. Use of open air siloxane production would be adequate cooled transformers is generally limited to supply new transformers. to dry, clean locations where the load re High flash-point mineral oils have quirements are fairly even and constant, been developed by RTE Corporation and where the maximum voltage does using the tradename "RTEMP" as a pos not exceed 30 kilovolts. They have been successfully used in large office buildings, particularly in tall buildings where the transformers are located every few floors. They are about equal in price- to askarel-filled transformers of the same kilovar rating. Closed gas-filled transformers use a dry gas as a heat transfer medium. Be cause they must be installed in pressuretight containers due to the changes in the gas pressure caused by changes in temperature, they are 30 to 40 percent heavier and cost two-thirds more than askarel transformers (and twice as much as oil-filled transformers). The maxi mum voltage ratings of these gas-filled transformers can be equal to those of liquid-filled units. They also avoid the maintenance problems caused by mois ture and dust in open air-cooled trans formers. Very few distribution transformers presently use askarels. Most distribution transfoimers are installed at the site of major generating plants and there would be little difficulty in designing new plants so that mineral oil cooled trans formers could be used safely. Those which do have askarels are located in side or on the rooftops of public, com- mercial, or industrial buildings. Most power transformers are situated in remote locations where fire or explo sions are not a threat to property. Min eral oils are commonly used in power transformers in these safe locations. Askarel-cooled power transformers are used to supply high-voltage electricity to electrostatic precipitators, which are sible replacement for PCBs in trans former applications. The primary advan tages of the high flash silicone mineral oil are price relative to biodegradability and low toxicity. . High flash-point synthetic hydrocar bons are being studied by Monsanto as a possible CB substitute in transformers, using the trade name "MCS-1866". These mixtures are purported to be en vironmentally acceptable and to have the high flash-point characteristics of RTEMP or silicone with relatively low viscostly and satisfactory heat transfer characteristics at a much lower cost. Manufacturers of capacitors and their suppliers are actively engaged in devel oping environmentally acceptable sub stitutes. Four capacitor manufacturers recently entered into a joint venture agreement with Justice Department ap proval for the development of an al ternative. - PCB-filled capacitors are presently be ing used in three principal categories of applications: high voltage power factor correction; fluorescent ballast and high intensity discharge lighting; and other capacitor applications such as "motor run" circuits, low voltage power correc tion, and electronic filter capacitors. Large, high voltage (4,800 to 13,800 volts) power factor correction capacitors are used by electrical utility companies to improve the efficiency of their system operations. They are generally installed outdoors in non-hazardous locations such as in banks in a substation or mounted in groups oivutility poles. Their location thus minimizes the importance of fire re usually mounted on or near industrial stacks. Evidence indicates it should be sistance. Butylated monochlorodiphen.vl oxide is being marketed by Dow Chemical possible to use mineral oil-cooled trans formers in air such applications. Company under the tradename "XFS4169L" and by McGraw-Edison under Railroad locomotive engines are the tradename "EDISOL" as a viable equipped with askarel-filled distribution substitute for PCBs in high voltage power transformers due to Penn-Central Rail capacitors. Power capacitors impreg road regulations. However, foreign ex nated with XFS-4169L have been found perience indicates that there is no sig to be more reliable than the same type nificant fire risk from the use of more of capacitor impregnated with Aroclor flammable liquids in these transformers. 101G after 3 years of accelerated life tests European practice has traditionally and more than 18 million kilovar hours in been to use mineral oil locomotive trans formers. The Japanese have been using silicone oils in new railroad transformers for the past four years and no service full-sized units without failures. The size of the XFS-4169L capacitors is the same as PCB capacitors at equal kilovar ratings.,Furthermorc XFS-4169T. has been found to be envircjjPjfP^aliv^Lce.niiLThle. problems have been reported. based on an assessment of its biodegrad- EEDERAL REGISTER, VOL. 42, NO. 22--WEDNESDAY, FEBRUARY 2, 1977 ' ..c .. DSW 360947 STLCOPCB4097565 6546 RULES AND REGULATIONS ability, bioconcentration In fish, toxicity in the June 10, 1976, notice of proposed With respect to discharges to the navi to animals, and toxicity to fish. The Dow standards for four pesticides (41 F.R. gable waters by manufacturers of ca . fluid is readily available to meet In- 23578-9). This issue has been dealt with pacitors or transformers utilizing PCBs, ~ creased market demand. The long-range at length in my Final Decision of De the discharges generally come from one price of power capacitors Impregnated cember 30, 1976, concerning effluent or more of the following sources within with XFS-4169L should be reasonable. standards for aldrin/dleldrin and other the various plants; Non-contact cooling Industry witnesses expressed optimism compounds (FWPCA (307) Docket No. 2, water, water-sealed vacuum pumps and that an acceptable substitute to PCBs pp. 46-56), 42 F.R. 2588 (January 12, steam jet ejectors, detergent washing of for use in small and medium AC ca 1977). . components and assemblies, boiler blow pacitor applications would be available in In order to obtain information as to downs, air conditioning condensates, the reasonably near future. There is no the availability of various methods of contact cooling water from welding and shortage generally of the substances control and related technology by which soldering operations, certain contami presently under consideration or in use discharges of PCBs might be eliminated nated process wastewaters (including as substitutes to PCBs in capacitors. At or reduced, the Agency engaged the serv vacuum pump condensates, laboratory this time, the industry-wide preference ices of Versar, Inc. ("Vrsar"), of Spring wastewaters and wastewaters from sur for use of a dielectric liquid to replace field, Virginia, who are recognized ex face treatment operations such as plat Aroclor 1016 in small industrial capac perts in tiie study of waste water treat ing, phosphatizing, painting, fluoride itors, Including low voltage power factor ment technology and the control of pol treatment, and caustic baths), sanitary correction, ballast lighting, motor run lutants discharged by industrial sources. and personal hygiene wastewaters, and ' circuit and electric filter capacitors, Versar prepared and submitted to the in the case of one plant which has a would be phthalate esters plus additives. Agency a report concerning the indus waste incinerator, the wet scrubber. How Phthalate esters have been used in trial discharge of PCBs and the assess ever, not all plants have wastewater small industrial capacitors in Japan for ment of wastewater management and streams containing PCBs from all these several years and are currently being treatment technology, including tech sources. Most plants have eliminated marketed for use in the United States nologies which are actually in use` or PCBs from many if not most, and in a by several manufacturers. Phthalate which are or may be available to indus few cases all, of these sources. ester capacitors would be the closest In tries to control or eliminate the dis Water is not an essential component of size to PCB capacitors. This substitute is charge of PCBs. This report, entitled the transformer manufacturing process. tijp pvnnti frig possible alter "Assessment of Wastewater Manage Similarly, there is no need to utilize natives. is readily available in'large,pro- ment, Treatment Technology, and As water in tiie manufacture of capacitors flUUtlOh Quantities ana appears to be en sociated Costs for Abatement, of PCBs filled with PCBs. The principal use for vironmentally acceptable. In those cases Concentrations in Industrial Effluents," water in capacitor manufacturing plants Where""phtfiaiate" estf"are in use, no was completed on February 3, 1976. It is as non-contact cooling water, which evidence of fire hazard has been reported. was supplemented with a report dated normally should not expose the water Protective devices are available for use July 2, 1976, entitled "PCBs Water Elimi stream to PCBs. Even non-contact cool with phthalate ester capacitors which nation/Reduction Technology and Asso ing water can be eliminated by use of a prevent case rupture and fire by remov ciated Costs, Manufacturers of the Elec heat exchanger, or a cooling tower, or a ing the capacitor from the source of trical Capacitors and Transformers; Ad "chiller", which Is like a refrigerator. electricity in the event of capacitor dendum to Final Report, Task II". Both Nathan Ray Clark of Universal Manu failure. of these documents were Incorporated as facturing Corporation described at the Metallized polypropylene film has been part of the Agency's statement of basis hearing the chiller in use at his com widely used in Europe in low voltage ca and purpose for the proposed standards, pany's capacitor manufacturing plant in pacitors. This new design is actively being and went into evidence at the com Totowa, N.J. which results in a com developed in the United States, with test mencement of the proceedings. The data pletely closed system, with no effluent marketing of both dry and liquid-filled reported by Versar, as amplified by the discharge whatsoever except for sanitary capacitors by some capacitor manufac 3 witnesses presented by EPA who testi wastes which go to a publicly owned turers. Although their, use is presently fied at the hearing concerning control treatment works. limited to below 330 volts, they would technology, form the principal basis for For those plants which do have dis eliminate PCBs and are small in size, the following discussion of technology. charges of effluents which may contain capable of operating at high tempera The domestic annual production of PCBs from one or more of the various tures and have a normal end-of-llfe fail- PCBs in 1974 was 40,466,000 pounds, of processes enumerated above, there are lire mode of an open circuit. This makes which approximately 22 million pounds existing technologies and feasible in them suitable for low voltage applica were used by capacitor manufacturers plant modifications so as to eliminate tions such as fluorescent lighting ballasts and 12 million pounds were used by each. These may be briefly summarized and air conditioners, and, placed to transformer industries. The balance re as follows: series, for higher voltage applications. flects inventory changes and about (a) Non-contact cooling water should 5,395,000 pounds of export sales. There be segregated from all other plant waters K. AVAILABLE CONTROL TECHNOLOGY AND ' are a total of 37 PCB user plants (ca and recycled. As noted previously, this . . PROCESS CHANGES . pacitor and transformer) in the United process can be aided by use of cooling As a preliminary matter, it should be Slates and 1 PCB manufacturer. Of the towers or heat exchangers, or a "chiller". noted that while I am adopting a prohi 38 plants, at least 11 directly discharge (b) Water-sealed vacuum pumps and bition on discharge of PCBs (with an their effluents to the navigable waters; steam-jet systems can be replaced with adjustment for influent PCB levels), I the remainder of discharge into publicly- mechanical, oil-sealed vacuum pumps, continue to believe that although Con owned treatment works. The sole PCB wliich arc presently in wide use in the gress obviously did not intend that the manufacturer, Monsanto, discharges a industry. objective of protecting the environment dally average of 3.06 pounds of PCBs to (c) All aqueous detergent washing op and human health be compromised on a publicly-owned treatment works. The erations can be replaced with organic- solely economic grounds, it is not incon daily discharges of PCBs by the capacitor vapor degreasing. Solvent recovery would sistent with Section 307(a) for the industry average 5.86 pounds and by the be accomplished by distillation, and still Agency in developing its proposed stand transformer industry 0.17 pounds per bottoms, or sludges, would be inciner ards to investigate and, where possible, day. Monsanto has announced its inten ated. At some locations, the detergent identify promising technology and give tion to cease the manufacture and dis washing of components can be com limited consideration to the likely eco tribution of PCBs as of October 31. 1977. pletely segregated physically from any nomic impact associated with its stand Consequently there is no present PCB areas where PCBs are used, so as to avoid ards. Tiie Agency's authority to take into manufacturer with a direct discharge the possibility of contamination. account these factors was noted in the into navigable waters, and it is expected (d) With respect to boiler blow downs, preamble to the standards proposed on that there will be no domestic manufac as well as any bleed from the closed non July 23, 1976, and discussed more fully ture of PCBs at all after October 31,1977. contact cooling water circuit, air condi- FEDERAl REGISTER, VOl. 42, NO. 22--WEDNESDAY, FEBRUARY 2, 1977 ,v... DSW 360948 STLCOPCB4097566 RULES AND REGULATIONS 6547 tionihg condensates, and any contact In a wide variety of Industrial adsorption Biphenyls: Transformer, Capacitor, and cooling waters (though In fact there is no need for contact cooling water and It should he eliminated), these can be collected In an equalization basin, and thereafter filtered, demineralized, and problems. It Is being applied successfully to the removal of new organics from water on a continual basis. Our cooperative labora tory work with several suppliers has con firmed preliminary published reports of suc cess In removing PCBs. All of the aspects of PCB Manufacturers" was prepared for the Agency by Jack Faucelt Associates, Inc., under the supervision of EPA's Office of Water Planning and Standards. This report also satisfied any require returned to the non-contact cooling commercial carbon adsorption from favor ment under Executive Order 11821 that water circuit. (e) Any remaining small amounts of contaminated water or other contami nated waste may be Incinerated or dis posed of by contract services. (f) One option to avoid contamina able capital and operating economies to rea sonable operating methods, materials of constuctlon, and lack of transport of pollution to air or land, have been proven for PCBslikc materials. There Is every reason to be lieve that there will be commercial success with PCBs removal from wastewater. an Inflation Impact Statement be pre pared, although it does not appear that the impact of these regulations is suffi cient to Impose a formal requirement for such a statement. - When the standards were proposed, tion of wastewater streams from plating operations is to completely segregate them physically. (g) This can also be done with re spect to painting operations. Still an other alternative to avoid contamination of waste streams from painting is to re place conventional painting operations, which require a water spray, with a dry electrostatic painting and labeling proc ess. Such conversion has been made in the Industry, but it is not known to what extent it can be applied to all plants. (h) Sanitary .and personal hygiene fa cilities should be installed which use a minimum amount of water. Disposal of these waters can be by Incineration or to a publicly owned treatment works. (1) For the one plant with a waste incinerator using a wet scrubber, the scrubber liquor can be collected in an equalization basin, filtered and treated by carbon adsorption. There does not ap pear to be an alternative dry process to replace wet scrubbing. Contaminated stormwater runoff into point source discharge conduits can be eliminated by diking or curbing and, where necessary, roofing over loading areas, storage areas, and other sources of contamination. Use of the foregoing technologies and process changes can be expected to result In achievement of prohibition of PCBs in process wastes (except.for certain proc ess wastes, specifically water used in welding, plating, or painting operations, and scrubber and quench water from in cinerator operations), and reduction of all other discharges to 1 pg/1 or less using a treatment system based upon ac tivated carbon. A more stringent effluent limitation should be achievable using either carbon adsorption or ultravioletassisted ozonation treatment, discussed more fully below. Any source should be able to eliminate any process discharge resulting from welding, plating and painting operations using the technolo gies previously outlined. The capabilities of a wastewater treat ment system based upon granular actirated carbon was Investigated and dis cussed at length. With respect to the feasibility of the. carbon adsorption treatment technology, Versar reached the following conclusion: This technology was further described at the hearing by Joseph L. Rizzo, of Calgon Corporation. Calgon Corporation has pioneered the development and use of the carbon adsorption teclinology, and Mr. Rizzo has been one of the principal individuals involved in this development effort. . . - Calgon Corporation presently has a contract with General Electric Co. to in stall a treatment system for the treat ment of effluent containing PCBs from the General Electric capacitor plants at Hudson Falls and Fort Edward, New York. General Electric is already in the proc ess of taking a number of remedial steps described above to reduce or eliminate wastewater flows containing PCBs. Among other things, they are segregat ing contaminated and uncontaminated streams and changing the cooling water from once-through to a recycled system, thereby avoiding a discharge. They are eliminating contaminated water wher ever possible, and replacing open trenches and sewers with drip pans. The detergent washing machine for capac itor cleaning is being replaced with a vapor degreasing unit, while other wash ing machines are using three independ ent closed water systems. PCB contam inated wastes are being sent to a disposal contractor. Wastewater will be im pounded In basins and then treated by the granular activated carbon adsorp tion columns furnished by Calgon. The Calgon contract Includes off-site spent carbon regeneration. / Houston Research, Inc., of Houston, Texas and Westgate Research Corp. of Marina Del Ray, Calif., have developed a technology which brings together twro previously proven water purification technologies, ultraviolet radiation and ozonation, to form a synergistic combina tion to destroy organic compounds, in cluding PCBs. Because UV-ozonation actually de stroys the PCB by a dechlorination reac tion, thereby converting it to relatively non-toxic products, it would appear to be capable of reducing PCBs to any de sired level. At the hearing, Dr. Mauk testified that PCBs could be reduced to any detection level, even 0.1 parts per trillion, and that their laboratory re the economic assessment was not yet complete. Indeed, the report was not available until early November, at which time it was placed in evidence at the hearing, the project officer in charge was made available for cross-examination, and public notice of the availability of the report was published in the Federal Register with opportunity for comment. (The absence of the report was one of the reasons why the Agency elected not to include in its July 23 proposal a pro hibition .on discharges by manufacturers of capacitors and transformers.) The Faucett report concluded that most of the transformer and capacitor manufacturers could financially afford to Install the technology outlined in the Versar report which would enable them to achieve compliance with the stand ards proposed by the Agency on July 23, 1976. The report further concluded, how ever, that few ifady W6ma actualjv in stall inis coonnttrrool lt_e_cnnoio_g_y.Katgfr they wornd drsconOnue tne'iise of , _ 'Together wli'en 'Vegulatl6n| WW6 I'itclois which crystal)iV.eri_fluring ~~ ~ The was passage of the Toxic Substances Control Act, Pub. L. 94-469, 90 Stat. 2003 (October 11, 1976), which requires a phase-out of the "distribution in com merce" of PCBs hv Jn)v 1. 1979. The sec ond was the decision by Monsanto to cease supplying PCBs as of Octoher 31 1977. . --This conclusion is entirely consistent with the evidence presented by the Elec tronic Industries Association. Philip Mur ray of the Cornell-Dubilier Electric Cor poration testified that by late 1978 his company would discontinue the use of PCBs in capacitors because of Monsan to's decision to discontinue the distribu tion of PCBs, and apart from any consid eration of section 307(a) standards. Thus the only impact of the proposed 307(a) standards on this company would be that the company would stop using PCBs a few months earlier, i.e., the difference be tween the time when the company would cease using them in response to the Mon santo decision and the time when the 307(a) standards would go into effect. Similarly, Nathan Ray Clark of the Universal Manufactufme Testiiiecl lhalt 'iiis capacitor manufactur- Our survey oi wastewater treatment tech sults were consistently below the .1 part lng plant in Bridgeport, Connecticut nology was most extensive, and excellent po per billion detection limits of their would. In reennnee t.he Arenr.v's pro tential tor current, near and long term meth ods was found. The longer term pilot or re search scale methods hold great premise of allowing zero discharge. analytical equipment. posed Standards, ee-ice ncW PnR^.ln 1. Economic impact. An assessment of- their Cftnacitoff a few mnntha-earlier the economic impact of the Agency's pro In this category, our prime recommenda posed standards entitled "Economic tion Is carbon adsorptlun. This technology Analysis of Proposed Toxic Pollutant ~t'FeaImcnr~EHl nolnrv. Both Mr. has been proved over most of this century Effluent Standards for Polychlorinated Murray and Mr. Clark testified that their FEDERAL REGISTER, VOl. 42, NO. 22--WEDNESDAY, FEBRUARY 2, 1977 DSW 360949 STLCOPCB4097567 <?5 IS RULES AND REGULATIONS Industry has no plans to import PCBs, and that they are looking as rapidly as possible for substitutes, which they ex pect they will have. . Dr. Ernest Mosbaek, who is with Jack Faucett Associates, Inc. and was project leader responsible for preparation of the economic assessment report, testified that he had reviewed the testimony of Messrs. Murray and Clark in this regard, and that their decision to stop using PCBs in mid-1978 was consistent with his findings with respect to the rest of the transformer and capacitor manufactur ing industry generally. Tftus the eco ----- :----- sessment report coppiiiricditet decisions' iparnnafiua^^ tS) the Toxic Substances Control Act just signed by President Ford which for bids production of PCBs in the U.S. after January 1, 1979, or their sale after June 30, 1979. Imports would be forbidden by June 30, 1979. The economically useful life of effluent treatment facilities ap pears to be so short that investment in treatment is unlikely." The Faucett report also concluded that the proposed standards themselves would result in price increases industry-wide for capacitors of less than 5 percent in 1977, and little price increase with re spect to the transformer industry. Fur ther, the report concluded that "there are no significant effects on energy consump tion, balance of payments, or employ ment. The announced and apparent shifts to non-PCBs and the expected de mand for capacitors and transformers are likely to increase rather than de crease sales and industry-wide employ ment." Testimony and evidence indicate that there appears to be no threat to the domestic transformer and capacitor in dustry from foreign competition, and It is unlikely that the 307(a) standards would interfere with energy conserva tion efforts. , M. THE AMBIENT WATER CRITERION In its July 23, 1976 proposal, the Agency provided for an "ambient water criterion" for PCBs of 1 part per trillioA (0.001 micrograms per liter). Although an ambient water criterion is not ex pressly required under section 307(a), the Agency concluded that the establishment of such a criterion would be an impor tant ingredient in carrying out the man date of that section to provide "an am ple margin of safety" for organisms which might be affected by discharges of PCBs to the aquatic environment. The rationale for the establishment of this ambient water criterion is discussed in the preamble portion of that notice of proposed rulemaking, 41 FR at 30470 and 30473, as well as in the preamble to the Agency's notice of proposed toxic pollut ant effluent standards for aldrin/dieldrin, DDT (DDD, DDE), endrin, and toxapliene published on June 10, 1976, at 41 FR 23576, 23579-23580. Water criteria are meant to reflect an estimated safe level' of a pollutant in an aquactlc environment which will pro At 2.5 ppm (milligrams per kilogram In the tect against adverse effects from chronic food) reproductive disfunction occurred In. exposure. If there are enough data to the rhesus monkey. establish a "no-effect level" for a sub stance, that level can be used as the water quality criterion. However, there are rarely enough data to predict with confidence the "no-effect level" for all At 3 ppm (mUUgrams per kilogram In the food) mortaUty was seen In the rhesus . monkey. . In rats, 0.5 ppm (milligrams per kilogram In food) resulted In the Induction of liver enzymes. affected species. In such cases, it is a rec At levels of between 40 and 300 ppm PCBs in ognized and sound scientific practice chicken feed, deaths of chickens occurred. (and one recommended by the National Academy of Sciences) to derive a water quality criterion for a particular sub stance by multiplying an "application factor" by the acute toxicity value for Reproductive failures in chickens occurred at between 6 and. 10 ppm PCBs In the food. /. Ulceration In the stomachs of dogs occurred after long-term feeding at 1 ppm PCB In feed. the most sensitive species sought to be protected. The application factor may be an experimentally derived factor or, more commonly, a factor set at a level judged by general experience with the effects of pollutants on aquatic orga . Furthermore, a criterion of 0.001 pg/1 Is substantially below the lowest observed effect levels in aquatic organisms. For example it is well below the following documented effect levels: nisms to provide adequate protection. 0.1 g/l of PCBs will cause population shifts (The criterion determined by this In phytoplankton. method would have been higher than the 0.001/ig/l criterion proposed by the Agency.) . In establishing a criterion for PCBs, however, it was determined that this ap proach would not provide adequate pro tection against possible harm resulting from chronic exposure, due to the extraordinary bioaccumulation potential of PCBs. Accordingly, the Agency con sidered bioaccu mutation as well as chronic effects in determining the proper ambient water criterion for PCBs. As discussed elsewhere herein, the bioac cumulation potential of PCBs has been demonstrated in the laboratory to be up to 274,000 times the measured PCB con centration in the water. (This figure, de scribed above, was developed from a long-term study with Aroclor 1242. Dur ing the hearings, EPA introduced evi dence through Dr. Lauer that laboratory bioaccumulation factors for Aroclor 1254 0.4 to 0.6 pg/1 lowers the reproductive poten tial of some Invertebrates. 0.1 pg/1 wlU lower the species diversity of some Invertebrates. Development of the ambient water cri terion was tlie initial responsibility of Dr. Leonard J. Guarraia, Chief of the Criteria Branch, Office of Water Planning and Standards, EPA. This effort was car ried out thoroughly and carefully, in con sultation with many scientists (includ ing aquatic biologists, toxicologists, and chemists) both inside and outside EPA. These scientists concurred in the judg ment of EPA that the proposed ambient water criterion of 0.001 pg/1 should pro vide an ample margin of safety for aqua tic organisms and most consumers thereof.7 The factors which the Administrator must consider in establishing toxic pol lutant effluent standards under section 307(a)(2) are "the toxicity of the pol may be as high as 307,000.) The evidence lutant, its persistence, degradability, the also shows that bioaccumulation "in the usual or potential presence of the af field" may be substantially higher than fected organisms and the nature and ex these levels. Thus the Agency concluded tent of the effect of the toxic pollutant that it would not be unreasonable to use on such organisms." The level of con the highest demonstrated laboratory trol must be one which the Administrator bioaccumulation factor in deriving its . determines provides "an ample margin of ambient water criterion. safety" for organisms to be protected, as The ambient water criterion of 0.001 proposed by the Agency was derived by examining the lowest documented chronic effects levels in aquatic orga nisms, as well as the lowest no effect levels in consumers of aquatic organisms. It was determined that the criterion must be at a level which. If bioaccumlated 274, 000 times, would result in tissue levels below the lowest level at which adverse results in consumers of aquatic orga nisms were reported. The proposed criterion of 0.001 pg/1 multiplied by 274,000, produces a tissue level of 0.274 parts, per million (ppm). This is below any of the reported effects levels relied on by the Agency in develop ing, the criterion, exemplified by the fol lowing: ' - required by section 307(a) (4). Although human health Is not ex pressly mentioned In section 307(a), other sections of the Act, coupled with the legislative history, leave no doubt that humans are among the organisms to be protected. See sections 402 (k) and 502 (13) of the Act; and "A Legislative His tory of the Water Pollution Control Act Amendments of 1972," pp. 1421-2, 1495-6 (S. Rept. No. 92-414, 92d Cong., 1st Sess., October 28, 1971, pp. 3-4, 77-8). According to the latter, the Adminis trator must consider under section 307 (a), among other things, "the seriousness and irreversibility of any effects on man or the environment that might occur" and "the possibility for incorporation into biological organisms and man in concentrations which the latest scien- At 0.04 ppm (milligrams per kilogram In the food), total reproductive failure wits ob served in mink. At 3.57 ppm (milligrams per kilogram In tlie food) mink died. ' T Under section 304(a) of the Act the Agency has also established an ambient water criterion of 0.001 ,,g/l. (See "Quality Criteria for Water (1976)"j. ' FEDERAL REGISTER, VOl. 42, NO. 22--WEDNESDAY, FEBRUARY 2, 1977 DSW 360950 <* STLCOPCB4097568 RULES AND REGULATIONS . ... 6549 tlfic knowledge suggest will produce ef exceed 274,000. Dr. Nisbet, who had pre with Arodors 1260 and 1254, in the case fects on man and organisms." Id., p. 78. viously expressed reservations about cer of Aroclor 1254 at only 20 ppm In the However, In preparing the Criteria tain aspects of tills evidence, testified diet. Moreover, PCBs have been shown Document, the Agency acknowledged that the new data had "cleared up the to Induce neoplastic nodules in rats at that the proposed criterion of 0.001 /<e/l last two remaining substantial pieces of levels as low as 10 ppm in the diet. The might not in fact provide assurance of evidence which have cast doubt upon significance of these findings is that it an "ample" margin of safety for humans that conclusion". Consequently Dr. Nis Is impossible on the basis of existing and some consumers of aquatic organ- bet testified that a figure In the.rangc of knowledge to establish "threshold" or and some consumers of aquatic orga 1-3 million would be an appropriate "no effect" levels for chronic exposure to nisms. Section V of tire Criteria Docu number to use as a bioaccumulation fac PCBs. Calculations performed by EDF ment stated: The chronic effects of PCBs In man may occur at extremely low concentrations. Al though It becomes virtually Impossible to Btato with confidence that any PCB concen tor to predict exposures off consumers of fish. If these bioaccumulation figures are correct, then a criterion of 0.001 //g/1 would probably not provide an ample margin of safety for certain fish-eating and reviewed by EDF with Dr. Nisbet during cross-examination suggested that the hypothetical carcinogenic risk posed by PCBs to the human population might be substantial, especially if a figure of tration above zero provides an ample margin birds and fish-eating mammals, espe 1-3 million were adopted for the bioac of safety for man, the PCB criterion number cially species demonstrated to be sensi cumulation factor used in predicting is believed to provide protection for the tive, such as mink and bald eagles. Dr. exposure. aquatic environment, (p. 354) Nisbet testified that In his scientific New evidence that PCBs are associated The basis for the Agency's reservations opinion a criterion of 0.0001 //g/1 (0.1 with elevated cancer incidence in man, about the margin of safety provided for parts per trillion) or lower would "prob both in the Yusho episode and in occupa humans and certain other consumers are ably be necessary" to provide an ample tional exposures, although Inconclusive expressed in the July 23, 1976 notice of margin of safety for such species. Fur on the basis of the Information pre proposed rulemaking and in a report pre ther, the reproductive failures in herring sented, nevertheless adds considerably to pared for the Agency by Dr. Ian Nisbet gulls In Lake Ontario are now associated the degree of concern for the risks of low- on the basis of Sections I-IV of the Cri teria Document and may be summarized as follows: (a) Effects of PCBs in mammalian test species have been noted at very low lev els of exposure: (b) ``No-efiect levels" for toxic effects of PCBs in mammals have not been es tablished in most cases: ' (c) Humans are exposed for much longer periods (including pre-natal ex posure) than the experimental animals; (d) Humans are known to retain PCBs in their tissues more efficiently than the experimental animals, with consequent greater exposure to sensitive organs; (e) Human breast-fed infants prob ably ingest 30-40 times as .much PCBs as their mothers on a mg/kg basis; (f) Synergistic effects with drugs or other pollutants are likely in the human population and Indeed have been dem onstrated in several experiments with animals; (g) The presence of toxic contaminants and metabolites in variable concentra tions means that environmental residues of PCBs may be more toxic than the mix tures tested In the laboratory; (h) There Is some evidence that bioac cumulation factors in wild fish exceed the laboratory-based figure of 274,000 utilized In establishing the 0.001 p.g/1 cri terion. In the course of this hearing, additional evidence was presented which confirmed the soundness of the grounds for the res ervations expressed by the Agency in this regard. On the basis of this record, it becomes even more difficult to assert with confidence that an ambient water cri terion of 0.001 fig/1 for discharges would provide the requisite ample margin of with PCfB levels in the water as low as 0.003 g/1, so it is questionable whether this species also would be protected by a criterion of 0.001 //g/1. The. testimony of Dr. Allen provided additional evidence of the hazards of low-level exposure to PCBs, In that the offspring of rhesus monkeys exposed to 2.5 ppm In the diet are now known to be suffering from learning and behavioral deficits, and that the treated monkeys are continuing to give birth to affected infante after a year on uncontaruinated diets. Dr. Allen's recent work on metab olism of tetrachlorobiphenyl has ex tended and confirmed the evidence that the less chlorinated biphenyls are metab olized via highly toxic intermediates. Dr. Gelboin provided expert testimony at the hearing that the effects of PCBs, including Aroclor 1016, in Inducing hepatic microsomal enzymes in rate at very low dose levels would not only have direct predictive relevance for enzyme induction in humans, but would imply substantial risk to humans because of the expectation that Induced enzymes in humans would enhance the metabolism of drugs and carcinogens. Dr. Gelboin testified that alteration of this enzyme system "would be expected to change the incidence of cancer in humans." A series of calculations performed by Dr. Nisbet during cross-examination would tend to Indicate that a person with average con sumption of fish would be at risk from these effects. These calculations assumed an ambient water concentration of 0.001 fig/1 and a bioaccumulatJon factor of 274,000; the evidence that actual bio accumulation factors may be substan tially higher than this would increase the Implied risk. Additional evidence was introduced at the hear ing which increases the degree level exposures. The foregoing evidence makes it .very difficult to state with confidence that any ambient criterion above zero would pro vide an ample margin of safety to man. Nevertheless, although I regard the 0.001 criterion with considerable reservations, I am not prepared to change It at this time pending further development of the scientific data. My decision not to change this number at this time is prompted by two considerations. First, our knowledge at this time is not adequate to pick a specific number below .001 //.g/1 as being safe. Second, and somewhat more signif icantly, the question of the level at which the ambient criterion is set Is largely academic in view of the fact, dis- cussed elsewhere herein, that a prohibi tion on discharges of PCBs is being es tablished for manufacturers of PCBs and manufacturers of transformers and ca pacitors. This prohibition reflects the im port of the evidence reviewed above, namely, that every reasonable effort ehoifld be made to eliminate any further discharges of PCBs to the environment, and to minimize the risks of human ex posure. - V. MODIFICATION OF PROPOSED STANDARDS In proposing standards for the capaci tor and transformer manufacturers on July 23,1 considered imposing a prohibi tion on any PCBs in their discharge. I refrained from doing so in part because tho data then available Indicated that a prohibition under section 307(a) "at tills time would probably cause a severe Im pact on the transformer and capacitor manufacturing Industries which utilize PCBs, and deprive the nation of the fu ture availability of products which utilize 6uch transformers and capacitors." Ac cordingly, in the proposed standards I re quired that discharges be prohibited safety for all consumers of fish. of confidence that PCBs are carcinogenic where possible, and that other discharges The testimony of Dr. Vcith and Dr. in rodents. Dr. Kimbrouch not only in comply with the very test results which Risebrough reporting Improved measure troduced her own study of the carcino available technology can achieve. ments of levels of PCBs in the natural genicity of Aroclor 12G0 in rate; she also As noted earlier, when the Agency pro waters of the Atlantic and Pacific Oceans testified that she had diagnosed neoplas posed an ambient water criterion of 0.001 and Lake Ontario, adds considerably to tic nodules (characterized by Dr. Squire //g/1, it cautioned that for protection of the evidence that bioaccumulation fac as "precancerous, if not already cancer") human health and. particularly for some tors in wild fish In many cases appear to in rats treated in another experiment other organisms as well, a criterion even FEDERAL REGISTER, VOl. 42, NO. 22--WEDNESDAY, FEBRUARY 2, 1977 DSW 360951 STLCOPCB4097569 6550 RULES AND REGULATION lower than this might be necessary. In fact, the' present problem of PCB con tamination In the environment Is so severe that In many waters throughout the United States PCB loads are already . in excess of this number, in some cases by as much as three orders of magnitude. A survey completed by EPA's Office of Toxic Substances in January, 197C, en titled "Review of PCB Levels in the En vironment", reported widespread pres ence of PCBs in the Nation's waters at levels far exceeding 0.001 ^g/1, and in some cases levels at or above 1 mE/1. Although point source discharges rep resent a relatively small part of the total environmental PCBs problem, discharges from plants manufacturing capacitors and transformers which utilize PCBs as a dielectric or heat transfer fluid repre sent the largest industrial categories. Moreover, discharges from such facili ties are having profound adverse effects on the aquatic ecosystems into which they are discharging. Dr. Gilman D. \ Veith, a research chemist at the EPA \ Environmental Research Laboratory-- Duluth, Minnesota, presented at the hearing a group of chromatograms of fish extracts from approximately 25 wa tersheds. He testified that "in each of the watersheds in which the very high concentrations of PCBs were observed, a capacitor or transformer manufactur ing or production plant is or has been located in the watershed." He noted by way of example that fish in the Coosa River and Choccolocco Creek contained PCBs in excess of 25 parts per million ' (ppm) in their issue. Fish from Lake Hartwell, Georgia, contained 41 ppm of the PCB Aroclor 1242, while the Hudson River showed fish contain ing Aroclor 1016 at levels as high as 350 ppm. PCB levels in the Acushnet River, where General Electric manufac tures PCB-filled transformers, are so high that the river has been closed for fishing by EPA Region IV. All of these levels are substantially above the 5 ppm temporary tolerance, or "seizure level", for PCBs in fish established for the pro tection of public health by the Food and Drug Administration (FDA) of the De partment of Health, Education and Wel fare, 21 CFR 122.10 (July 6, 1973). (It \ .should be' noted that the FDA an nounced on February 26. 1976, that it is actively considering a lower temporary ' tolerance for fish in light of recent toxi cological data concerning PCBs, 41 FR ' 8409.) . Moreover, because of the extraordi. . nary longevity, persistence, and mobility of PCBs in the environment, once there is a discharge of PCBs into a particular aquatic environment, the threat of ex . posure is not limited to the immediate area, but in fact is virtually unlimited in terms of potential transport and expo sure. In n situation where all of the evi dence relating to toxicity, bioaccumulalion, persistence, and transport indicates that ambient levels must not exceed . 0.001. Mg/1 and perhaps should be well below' that, while at the same time evi . dence from the "field" indicates that this level is already exceeded in many As noted above, the argument for a parts of the Nation's waters, it is ex prohibition based on considerations of ceedingly difficult to justify any dis toxicity Is compelling. Only the most se charge of PCBs whatsoever which would vere adverse economic impact should be necessarily further increase this already allowed to override these toxicity consid dangerous environmental burden. erations, which Congress strongly em The standards proposed on July 23, phasized (both in the language and the 1976, included a prohibition on the dis legislative history of section 307(a)) charge from any PCB manufacturer. must be paramount. It now appears that This is consistent with the purpose of no such severe adverse economic impact the Act, and imposes no economic hard is likely. Accordingly, I believe the stand ship since there is no present PCB man ards proposed on Jnlv 23 should ho iriodi- ufacturer with a direct discharge. For fipfl to .nmuj^o fnr- .n nmhihitinn .f'n. jnv manufacturers of transformers and ca pacitors, the Agency proposed a prohi PCBS.iQ^flhaJigaJ^-aiai -capacitors r-- 1iTantHY1il'S Pf bition on PCBs in the discharge of most process wastes, and for all other dis charges from existing sources, a maxi mum PCB concentration of 1 Mg/1 as a daily average, calculated over any cal endar month, with occasional excursions not to exceed 5 ng/1. For new sources the standards were proposed as 0.1 pg/1 maximum daily average with occasional excursions not to exceed .5 le setting of stringent- standards in this proceeding will have an additional impact on the control of the discharge of PCBs beyond the coverage of the three industrial categories whose direct dis charges are regulated under these stand ards. the Ag ' _________ ` tieaimjpt^tandards^for In making the translation from the de sired ambient water criterion to the "end-of-the-pipe" effluent standard re quired by section 307(a), the Agency con sidered mixing zones and the constraints of-technology and economics. With re spect to mixing zones, the Agency took into account the fact that following dis charge from a point source a pollutant normally becomes dispersed and diluted in the receiving waters, with the result that as much as a 1,000-fold dispersion or more of the pollutant concentration may take place within the bounds of a reasonable mixing zone. In some in stances, because of local hydrologic or hydrographic conditions, there may not exist adequate dispersion and dilution to achieve the desired ambient concentra tion of 0.001 mE/1- To deal with these sit uations, the Agencf relied upon the "tightening variance clause" set forth in 5 129.7 of the general implementing regu lations to provide establishment of a more stringent effluent limitation where necessary to achieve this objective. In doing so, however, the Agency expressed the following concerns: . there are other point source categories which are dis charging PCBs and which are not sub ject to the present standards. These in dustrial categories include manufactur ers of some machinery and mechanical products, transformer and capacitor reclamation and repair facilities, in vestment casting operations, paper mills using recycled paper and facilities utiliz ing PCB-filled hydraulic and heat trans fer systems. Contrary to the assertions of EDF and NRDC, insufficient data presently exist upon which the Agency can reasonably base an expansion of the scope of coverage of the regulations at issue here to additional industrial point source categories. In the absence of standards promulgated under section 307(a) for PCBs which expressly apply to discharges from these operations, they Because of the extraordinary persistence will be regulated under the NPDFS per of PCBs, reliance on mixing zones, while of mit system, with limitations established assistance in the immediate future, cannot be regarded as a long-term solution to the problem. Finally, it is recognized that to allow a dis charge at the proposed levels may pose some risk of adverse effects to some organisms, par ticularly those located near the outfall, and dll' it case-hv-case basis. Under section 4ilmJ (1) of the Act, the cognizant per mit-issuing authority must issue a per mit with "such conditions as the Ad ministrator (or Regional Administrator or state director of an approved permit possibly to the consumers thereof. (41 F.R. program) determines are necessary to at 30476) carry out the provisions of this Act", in As discussed elsewhere in this Decision; the constraints of technology and eco nomic impact do not appear at*this time to be as severe as was feared at the time of the proposal of the standards. Because of the Toxic Substances Control Act and Monsanto's decision to stop supplying PCBs, transformer and capacitor manu facturers will phase out their use of PCBs by mid-1978. Therefore, a prohibition on cluding compliance with requirements under section 307. The standards set in these proceedings will provide major guidance to the permit-issuing authori ties across the country in setting ap propriately protective effluent limitations for other industries with PCBs in their discharge in order to cany out the pur poses of Section 307. Furthermore.,.,, t,he .transformer discharge of PCBs effective in the year ancT c imr us will have no greater economic Impact ing than that of the standards originally ' fiflOxjsaae to ' fflu- proposed on July 23,1976. FEDERAL REGISTER, VOl. 42, NO. 22--WEDNESDAY, FEBRUARY 2, 1977 DSW 360952 STLCOPCB4097570 RULES AND REGULATIONS 6551 slncc~tliey will no longer be "electrical capacitor manufacturers" or "electrical transformer manufacturers" producing or assembling products "in which PCB or PCB-containing compounds are part of the dielectric". (See the specialized def initions, 129.105(a) (2) and (3) of the proposed standards.) At thatjoint they, needed even after the cessation of use of PCBs, since PCBs will remain in the pipes and system, and may thereby con tinue to contaminate the effluent. Thus the standards established in these proceedings will provide a vital foundation for the control of the dis charge of PCBs from all other point sources. Accordingly, it is imperative that these standards be sufficiently strin gent to provide "an ample margin of safety" for any important organism likely to be affected, including humans. Because of the extraordinary and per haps unique persistence, mobility, and environmental transport of PCBs, they are frequently found in the intake waters of industrial plants. In the general Im plementing regulations proposed on June 10, 1976, and promulgated on Jan uary 12, 1977, 42 F.R. 2588, 5 129.6 in cluded a provision for adjustment of the effluent standards for the presence of a toxic pollutant in the intake water. Es sentially, this section is modeled after the Agency's "net-gross" regulations for NPDES permits issued under section 402 of the Act, 40 CFR 125.28. Section 129.6 of these general implementing regula tions allows a credit for presence of pol lutants in a facility's intake water if the following conditions are met: (1) The source of the owner's or operator's water supply is the same body of water Into which the discharge is made and if (2) it Is demonstrated to the Regional Administra tor (or State Director; if appropriate), that the toxic pollutant(s) present in the owner's or operator's intake water will not be re moved by any wastewater treatment systems whose design capacity and operation were such as to reduce toxic pollutants to the levels required by the applicable toxic pol lutant effluent standards in the absence of the toxic pollutant In the Intake water. . The Agency has interpreted "waste water treatment systems" to include process changes or other controls. In this section, as in the comparable provisions of 40 CFR 125.28, the Agency does not allow "net" treatment where the source of the intake is a different water body than the receiving waters into which the effluent is discharged. A principal reason for this is to prevent degradation or pollution from the receiving waters with waters from other sources which may be chemically or biologically "dif ferent" and lienee harmful to the re ceiving water ecosystem. EIA argued that it would be inequita ble to require a plant not only to reduce or eliminate any and all additions of PCBs from that plant's own operation and facilities, but aLso t-o clean up the pollution of others which may have con taminated tlie plant's Intake waters. I find that tills argument has special force where a zero discharge is being set and Tlie Agency does not find any merit in where process controls (which may in this objection. Most commercial PCB clude elimination of the use of PCBs) mixtures are now known to contain are the likely response of industry to the small quantities of polychlorinated Agency's standards. In light of the wide dibenzofurans (PCDFs) as impurities. spread presence of PCBs in Influent One study with Aroclor 1016 did not waters I believe that an exception should show PCDFs present but only one sample be made to the Agency's policy so as to was tested and tlie results proved incon allow a credit for PCBs in the influent clusive. Small quantities of PCDFs ap in appropriate circumstances. Including pear to be formed from PCBs in service, those where the source of the intake by photochemical reactions and - by waters is not the same as the receiving metabolism. Hence PCBs in the environ waters. This can be achieved by adding ment arc likely to contain small, but a new section to the regulations, as variable quantities of PCDFs. follows: / (Section 129.105(e)) Adjustment oj Effluent Standard for Presence oj PCBs in Intake Water Whenever a facility which is subject to There is little precise information about the toxicity of PCDFs; only one isomer has been tested and only in short term tests. It was found to be extremely toxic to chickens and guinea pigs, but these standards has PCBs in Its effluent not to rats or mice. PCDFs are said to which result from the presence of PCBs In be particularly toxic and acneigcnic in Its intake waters, the requirement of sub man and to have been abandoned by in section (1) of { 129.6(a), relating to the source of the water supply, shall be waived, and such facility shaU be eligible to apply for a credit under { 129.6, upon a showing dustry for that reason. Although there *is evidence that FCDFs may play a role in the observed toxicity of commercial by the owner or operator of such facility to PCB mixtures, some of the observed the Regional Administrator (or State Di symptoms are also produced by pure rector, If appropriate) that the concentra chlorobiphenyl isomers or by PCB mix tion of PCBs In the intake water supply of tures with extremely low levels of such facility does not exceed the concentra tion of PCBs in the receiving water body effluent to which the plant discharges Its effluent. PCDFs. -. It is impossible to disentangle the toxic effect's of PCDFs frorii those of PCBs. Likewise it is not possible with our The provisions of this section are, of present knowledge and capabilities to course, subject to the requirement that predict or measure tlie exposure of hu any applicable state water quality stand ' mans or other vulnerable species to ards or other applicable standard be PCDFs. In regulating PCBs, therefore, complied with. (See 129.5(e) of the it is necessary to recognize that the mix general implementing regulations.) In tures found in the environment may be addition, it is expected that appropriate more (or less) toxic than the commer monitoring will be performed or required cial products whose toxicity has been by the permit issuing authority to in studied in the laboratory. Although the sure that the anti-degradation policy lower chlorinated components of PCB reflected in this section is not violated. mixtures aTe less persistent and less bio (See 5 129.5 and 129.6.) _ accumulated than the higher chlo Section 307(a) (6) of the Act provides rinated compounds, tetra- and even that any effluent standard or prohibition trichlorobiphenyls are sufficiently per shall take effect on such date or dates sistent and bioaccumulated to lead to as specified in the order promulgating significant human exposure. the standards, but in no case riiore than As regards toxicity, several of the one year from the date of promulgation. critical toxic effects in mammals were In order to permit manufacturers to reported in experiments conducted with change over to substitute materials or Aroclor 1254, or in some cases Aroclors to install technology to attain a pro- 1260 and 1248. Since much of the ma hibition on PCBs in their discharge, I terial subject to discharge now consists am allowing a one-year period for of Aroclors 1242 and 1016, the Agency' compliance. . considered whether their toxicity was m. Summary of Principal Comments to Proposed Toxic Pollutant Ef fluent Standards for PCBs and the Agency's Responses Thereto substantially different. Given tlie molec ular constitution of Aroclor 1016, it was reasonable to assume that its toxicity would be generally similar to that of Aroclor 1242. Although differences were The principal comments of a substan noted between the toxicity of Aroclors tive nature, together with the Agency's 1016 and 1242 and that of the higher responses, thereto, including any revi sions to tlie proposed regulations'in light of such comments are summarized below: chlorinated PCB mixtures, there is in sufficient evidence on which to base a conclusion that Aroclor 1016 is sig nificantly less effective than higher chlorinated mixtures in causing the (1) Comments were received from the critical toxic effects under consideration. General Electric Company recommending -Furthermore, studies have shown that the Agency develop separate criteria for metabolism of PCBs appears to proceed different Aroclor mixtures because mixtures containing or capable of degrading to pentaand hcxaclilorlnatcd dlbenzofurans (rCDFYi) pose a more serious liamrd than do such mixtures as Aroclor 1016, which contains fewer pent- and hexachloroblphcnyls (the via toxic, possibly carcinogenic, inter mediates. This suggests that tlie degrad ability and metabolism of Aroclor 1016 may be associated with increased toxicity. Accordingly in establishing substances associated with the correspond toxic pollutant effluent standards for ing PCDFs). : PCBs there appears no convincing basis FtOtSAl REGISTER, VOl. 42, NO. 22--WEDNESDAY, FEBRUARY 2, 1977 \- . : --- - OSNN *>0953 STLCOPCB4097571 .6552 RULES AND REGULATIONS for setting different standards for the various isomers or Aroclor mixtures. -- (2) General Electric also commented that the Agency failed to provide any rational basis for choosing- .001 ^g/1 as the ambient water quality criterion. The Agency set forth in great detail its consideration of "the toxicity of the pollutant, its persistence, degradability, the usual or potential presence of the affected organisms in any waters, the im portance of the affected organisms and the nature and extent of the effect of the toxic pollutant on such organisms,'' as required by section 307(a) (2) of the Act, in the PCB Criteria Document. The Criteria Document concluded: "Based upon the proven bioaccumulation poten tial of 274,000 times the ambient water concentration in controlled conditions, the level of 0.001 ng/1 PCBs should afford protection for consumers whose sole diet consists of aquatic organisms contam inated at the "worst or maximal level predicted by the laboratory data." This "worst or maximal level" can be calcu lated to be 0.274 mg/kg of fish flesh, lower by a factor of approximately 2 than the 0.64 ppm which caused total reproductive failure in mink and the 0.5 ppm which caused hepatic enzyme induc tion in rats. A more detailed discussion of the Agency's derivation of the cri terion number and the data upon which it was based can be found in Chapter V of the Criteria Document filed as part of tire Agency's statement of basis and purpose in these proceedings. (3) The National Council of the Paper In dustry for Air and Stream Improvement (NCASI) commented that the Agency's standards were arbitrary and capricious be cause they were based on the belief that bioaccuriiulallon factors derived from experi mental data were 10 to 30 times those ob served in the laboratory. The Agency's ambient water criterion was based primarily on laboratory data, as noted above. "Field" data taken from the wild indicated that actual bioaccu mulation levels experienced by wild fish may be considerably higher than levels reported in the laboratory--possibly as high as 10 million. These data confirmed the soundness of the Agency's selection of a bioaccumulation figure at the high end of the spectrum of laboratory-de rived data, namely, a figure of 274,000. It was this laboratory number, however, rather than field numbers, which were used in the Agency's calculation. (4) NCASI faulted the Agency for having failed to Justify the differences between the criteria and standards as currently proposed and those proposed in December 1973. The Agency need not justify changes from earlier proposals. The Agency's de cision to gather new data and to repro pose the regulations is set forth in the Preamble to the Notice of Proposed Toxic Pollutant Effluent Standards for Aldrin/ Dieldrin, DDT, Endrin and Toxaphene which were published in the Federal Register on June 10, 1976, 41 FR 23576. The subject regulations are based on more extensive information and (he most recent data available to the Agency ns set forth in the Criteria Document and amble referred to above, and the Deci the hearing record. sion accompanying promulgation of the (5) NCASI commented that the Agency had not related Its proposed ambient water standards. The criterion number of .001/jg/l is the same as the federal water criterion and standards to any predicted or quality standard for PCBs which ap demonstrated need for water quality im pears in the Agency's "Quality Criteria provement in water bodies adjacent to PCB for Water (1976) " published pursuant to discharge. . section 304(a) of the Act but is intended The Agency is not required to consider the need for water quality improvement in siwcific water bodies under section 307(a) of the Act. The Agency based its ambient water criterion on the avail able information on the toxicity and bioaccumulative effects on PCBs In both lab oratory and natural systems. The tech nology report prepared for the Agency to have independent significance. The Agency has also determined that 307 (a) standards are necessary to re strict the addition of PCBs into our Na tion's waterways because of the poten tially serious threat to human health posed by the accumulated and wide spread presence of PCBs in the envi ronment. presented data demonstrating substan (8) General Motors recommended that tial discharges of PCBs from transformer the Agency recognize the existence of an and capacitor manufacturing industries often significant background level of PCBs into the navigable waters. It is believed in natural waters in establishing its ambient that the Agency's regulatory action will ' water criterion. reduce the adverse impact of PCBs in As previously noted, the Agency's es those receiving waters, although esti tablishment of an ambient water crite mates of rates of improvement have not rion is designed to provide an ample been made. Since in some water bodies margin of safety for aquatic organisms, the existing PCB levels already exceed the Agency's proposed ambient water cri terion, every reasonable effort should be made to reduce or eliminate any further discharge of this highly toxic and per sistent compound. and most consumers thereof and does not take into consideration actual am bient levels of PCBs found in the en vironment. The fact that some water bodies contain levels of PCBs higher than the criterion level was recognized (6) NCASI also criticized the Agency's am by Congress when it passed the Toxic bient water criterion for not referring to the Substances Control Act of 1976, includ EPA guidelines for fish fiesh. ing section 6 which requires the eventual Although the Agency noted the FDA action level of 5/ig/g for fish flesh, its criterion derivation is not dependent upon such a level. The Agency has pro posed a criterion intended to be protec tive in a "worst case" situation (i.e,, .001/ig/l of PCB in water and a 274,000 bioaccuinulation factor). FDA guidelines seizure levels and are not intended to be levels safe for chronic consump elimination of PCB use. Through regu latory action it is hoped that overall levels of PCBs in the environment will be reduced over time. As discussed elsewhere herein, the Agency has recognized the often signifi cant background level by allowing a credit for PCBs in the influent in cir cumstances not otherwise violative of the Agency's antidegradation polities. tion. (9) Comments were received from the City (7) Comments from the Ford Motor Com pany objected to the Agency's Inclusion of an ambient water criterion as unnecessary, scientifically inappropriate, and exceeding the authority of section 307(a) of the Act. They feared that the criteria would be mis of Akron Department of Public Service citing the presence of PCB levels in the Cuyahoga River which exceed the Agency's ambient water criterion of ,001/ig/l but which is not attributable to any known point source of PCBs. . interpreted as setting uniform federal-state The Agency recognizes the presence in water quality standards. They also urged that the Agency's proposed standard take into consideration the extent and probabil ity of environmental exposure to PCBs. the ambient waters of high levels of PCBs even in areas where no known source of PCBs has bee^K determined. It is indeed likely that significant amounts Section '307(a) does not preclude the of PCBs are contained in air fallout use of an ambient water criterion in the and rainfall, The data have shown that process of establishing toxic pollutant PCBs have a high propensity for biologi effluent standards. For the reasons set forth in the preamble to the notice of proposed rulemaking published on June 10, 1976, the use of this approach is sci entifically sound in light of the primary cal transport. (10) Several commenters asked the Agency to provide more detail concerning the ana lytical procedures which it expected to be used to detect PCBs at levels below 1/tg/i (1 emphasis of section 307(a) in protecting ppb). Particular concern was raised about against the effects of toxicity, which is. the presence of other chlorinated organic in turn to a large extent a function of compounds in industrial effluents which concentration of the pollutant. The could interfere with analytical methods. Agency, in setting nationally applicable The EPA analytical method acceptable toxic pollutant effluent standards, is not for sampling and analyzing PCB mix constrained to consider sile-specific cir tures is that specified in Part 136 of Title cumstances. Indeed section 307(a) urges 40 of the Code of Federal Regulations, the setting of national standards. In ar with tile additional requirement of the riving at these standards, extensive con use of a one liter sample size to increase sideration has been given to environ analytical sensitivity. The basic meth mental exposure, as reflected in the odology of gas chromatography Is used Criteria Document for PCBs. the pre to analyze for PCBs in ambient waters, FBOCRAl TEGISTEP, VOl. 42, NO. 22--WEDNESDAY, FEBRUARY 2, 1977 DSW 360954 STLCOPCB4097572 RULES AND REGULATIONS 6553 or otner animal tissue, and sedi rather has put iorward effluent stand Even though the section 307(a) re ments, as well as Industrial effluents. Al ards for PCBs to meet the environmental quirements may not apply once use of though the EPA method Is designed to requirements set forth In the stntule. PCBs in the manufacturing process achieve a detection limit of approximate The statute carries no obligation to pro ceases. National Pollutant Discharge ly l/'g/l, several EPA witnesses testified vide assurances with rcsi>ect to substi Elimination System (NPDES) permit at the hearings that reasonable reliability tutes. It would be expected that any con requirements may require achievement could be achieved at levels as low as sideration of replacement fluid environ of comparable limitations, which may in OQlfig/1 (1 ppt) by adapting the EPA mental acceptability would be in compli turn prompt the affected plants to con method to larger sample volumes. At the ance with the requirements of the Toxic sider utilization of treatment technolo lftg/1 level, intercferencc is not expected ' Substances Control Act and/or other gies similar to those discussed In the to be as serious an analytical problem os relevant federal and state statutes. Agency's statement of basis and purpose at lower levels of detection. In any event, In addition to the treatment tech to control the discharge of PCB residues it is recognized that mass spectroscopy is nology identified in the contractors re In manufacturing systems. Such tech capable of separating out PCBs from port prepared in support of these reg nology might be required for several other chlorinated organic compounds at ulations, the Agency has published guid- years until residues arc: totally flushed the lower levels. According to the analyt nnce for disposal of PCB contaminated from contaminated systems. At least one ical witness who testified on behalf of units in a notice entitled, "Polychlori manufacturer has agreed to install the the electrical capacitor industry, inter nated Biphenyl-containing Wastes, Dis requested technology, partially at least, fering compounds are not a major prob posal Procedures" in 41 FR 14134 for this reason. lem with effluent from capacitor manu (April 1, 1976). In addition, the Agency (16) P. R. Mallory & Co., Inc. commented facturing plants. The commentcrs are is required to prescribe methods for dis that the proposed standards give no con advised to refer their specific questions posal of PCBs by June 30, 1977 under sideration to the volume of water discharged concerning the EPA method to the EPA section 6(e)(1)(a) of the 1976 Toxic by a particular manufacturer and thereby Environmental Monitoring and Support _ Laboratory in Cincinnati. Ohio. (11) Another comment from General Elec Substances Control Act (Pub. L. 94-4G9, 90 Stat. 2003). These regulations are in the process of being developed at this encourage a presently small water user to use moro water lu order to dilute PCB con centrations in their discharge. tric disagreed with the Agency's inclusion time. . The proposed regulations combine a of process changes In conjunction with add on treatment in the technology identified for existing plants. General Electric suggested that such process changes only be required for new sources thereby only requiring exist ing sources to consider add-on treatment technologies. (13) Dow Chemical Company tJ.SA. ob jected to the Agency's statement that sat isfactory PCB substitutes ore not readily available and claimed that they produce a PCB substitute "which has been found en vironmentally acceptable and to perform equal to or better than capacitor grade prohibition of discharge of certain wastes with certain exceptions wherein a lfig 1 concentration must be achieved. Because wastewater quantities and feasible control alternatives appear to vary widely among plants, it was not feasible to include a mass limitation The Agency, by its contractors, has PCBs." . . similar to that proposed in other section evaluated several technologies available for reducing PCBs in waste discharges in cluding those leading to elimination of the discharge of PCBs. Since the Agency's stated goal is to reduce all designated section 307(a) toxic pollut ants to a concentration level of ap proximately the acceptable criterion number for that substance, the Agency has investigated process changes as well as add-on treatment. The identified tech nology upon which the Agency bases the proposed effluent standard includes proc ess changes where it appears that shell changes could be installed within one year, where equivalent PCB removals could be achieved and where such changes appear less costly than end-ofplpe treatment. The Agency Interprets section 307 requirements separate and apart from the effluent limitation guide lines requirements of sections 301, 304 and 306 of the Act. The Administrator lacks authority in this standard-setting process to pass judgment on the technical or environ mental acceptability of any potential PCB substitute. However, the informa tion submitted by Dow Is helpful and w ill no doubt be of interest to those man ufacturers of transformers and capaci tors who are actively engaged in seeking acceptable substitutes. The Agency notes that evidence adduced at the hearing suggests that the Dow substitute may not be satisfactory for use in small low volt age capacitors. Phthalatc esters were considered to be the most promising al ternative in such low voltage uses. (14) Comments wore submitted by sev eral capacitor manufacturers who were also represented at the hearings by the Electronics Industry Association. They noted that the 60le producer of PCBs (i.c,, Monsanto) has announced its discontinuance of PCB pro duction by October SI, 1977 and that capac 307 (a) standards. However, it should be noted that recycling would be required for large volume water uses (e.g., cooling water) to reduce the final discharge volumes. The standards as promulgated are sufficiently stringent as to make it virtually impossible to comply with them by means of dilution. (1G) The"State of California Water Re sources Control Board urged the Agency to Include firms engaged In the repair, remanu facture, salvage, and/or disposal of PCBfilled transformers and/or capacitors when It promulgated Its final PCB standards. The Agency recognizes that other dis charges of PCBs exist. The proposed regulations were not intended to include all sources of PCB discharges, but were limited to PCB manufacturers, capacitor manufacturers and transformer manu facturers based on available data. Upon obtaining additional information on other PCB sources and the relevant ex (12) Comments from Edison Electric In stitute stated that even If proven acceptable substitute dielectric and Insulating fluids are available for new electrical equipment, substitution of the fluid or replacement of itor manufacture after July 1, 1978 will by necessity use dielectrics other than PCBs. They argued that the Installation of treat ment technology similar to that Identified by the Agency for such a short period would be tent of their discharge, the Agency will take appropriate regulatory measures to limit the addition of PCBs from,other sources into the environment. . the equipment would not be an acceptable Impractical and uneconomical, These com- (17) General Motors noted several opera solution for existing capacitors and trans meuters thus anticipated that their produc tional difficulties with the treatment tech formers. They also noted that EPA must pro tion facilities would be closed from the point nology for PCB removal which the Agency vide assurance that substitute fluids are in time when the standards become effective briefly described in its Notice of Proposed environmentally acceptable and that "normal until a suitable replacement fluid becomes Rulemaking on July 23, 1970. They ques methods for handling, storing and disposal available. tioned the effectiveness of carbon adsorption of these substitutes" can be used. An Imme diate problem facing users of PCB-flllcd These same facts were brought to the for removal of PCBs In the presence of other organic`compounds; the availability of other equipment was said to relate to proper meth Agency's attention at the hearings. The treatment technologies Buch as oil extraction ods for disposal of rotlrcd or failed units. Agency's economic impact statement pre for PCB removal; the Agency's cost estimates The standards here at issue control effluent discharges into navigable waters and do not require substitution of fluids in capacitors and transformers already in use at this time. The Agency has not banned the use of PCBs by industry but pared in support of these standards (No tice of availability published at 41 PR 51048 (November 19, 1970)) has taken these considerations Into account in de termining that no significant economic impact will result from the promulga tion of the Agency's proposed standards. for a PCB treatment system; and the impact of PCB disposal problems on domestic energy consumption. Evidence presented at the heaving by a representative of Calgon Corporation, an acknowledged leader In carbon ad sorption technology, Indicated that car- FEOERAt REGISTER, VOl. 42, NO. 22--WEDNESDAY, FEBRUARY 7, 1977 DSW 360955 STLCOPCB4097573 6534 RULES AND REGULATIONS bon adsorption will treat PCB contain ' IV. Conclusions . ' hearings, as discussed In the preceding ' I -5 ; - ing effluents down to the 1 /ig/1 level. The presence of other chlorinated organic compounds is not believed to be a major problem in the control of effluent from capacitor manufacturers. In any event, biological processes can be utilized to re duce levels of such other compounds prior to carbon adsorption treatment. By increasing the mass of carbon in the sys tem, effluents with increased degrees of chlorination are capable of being treated. . The Agency's contractors considered liquid/liquid extraction using oils during the course of its study of treatment tech nologies for PCB-containing effluents. However, their study was not intended to be an exhaustive listing of potential treatment alternatives. Rather their pur pose was to show that particular tech nologies were available. Because no lab oratory or pilot data were available on oil extraction technology, it was not deemed fruitful to explore a hypothetical process. Furthermore, the partition co efficient for oils is much higher than that for carbon, potentially resulting in great er cost and disposal problems. The Agency arrived at its cost figures based on the most current information available from suppliers of treatment systems. It therefore believes that its cost estimates were reasonable. The disposal problem associated with . PCBs was raised by other comments as well as by General Motors and was ad dressed more fully above. As noted pre viously, the Agency is required under TOSCA to study this issue but it is not a relevant concern in the context of these 1. The toxic pollutant effluent stand ards proposed by the. Agency for PCBs ( 129.105) by publication in the Pedekal Register on July 23, 1S76, 41 FR 30468 ct seq., together with the Agency's sup porting statement of basis and purpose, embody a careful and thorough consid eration of the toxicity of PCBs, their per sistence, degradability, the usual or po tential presence of affected organisms in any waters, the importance of the affected organisms, and the nature and extent of the effect of PCBs on such or ganisms, as required by section 307(a) of the Act. The evidence presented at the rulemaking hearings by the Agency and also by the various objecting parties expanded upon and added to the exten sive data base which was set forth by the Agency in its statement of basis and purpose. 2. The Findings set forth above are based upon substantial evidence in the record concerning the extraordinary tox icity, persistence, and mobility, the low degradability, and the severe bioaccumu lation properties of PCBs, as well as their serious human health implications. When the Agency issued its proposed standards for PCBs on July 23, 1976, it stated in connection with the ambient water criterion that it was "virtually im possible to state with confidence that any number above zero provided an am ple margin of safety for man" (41 FR 30470) . Additional evidence introduced at the hearing confirmed the soundness of that reservation, and the seriousness of the PCBs problem. This included sub ' Findings, I have concluded that the toxic pollutant effluent standards as originally proposed should be modified so as to es tablish a prohibition on PCBs in any discharge by any manufacturer of PCBs or any electrical transformer or electri cal capacitor manufacturer, in order to provide an ample margin of safety for the protection of aquatic and other orga nisms and consumers thereof, including humans, who may be affected by dis charges from such manufacturers. 5. In addition, for the reasons set forth in the preceding Findings, I have concluded that because of the extraordi nary persistence and mobility of PCBs which often results in the. presence of PCBs in intake water supplies, the pro posed standards should be modified so as to include a new 5.129.105(e) which would allow, for PCBs only, a credit for pollutants in the intake waters where the source of those intake waters is other than the waterbody to which the effluent is discharged, so long as the PCB concentration in such intake wa ters does not exceed and thereby degrade that of the receiving waters. Such a credit is already available where the source of the Intake water is the same as the receiving waterbody, under 40 CFR 129.6 (the general implementing regula tions, promulgated on January 12, 1977, 42 FR 2588, 2614). 6. In subsections (b) (1) (i), (c) (1) (i), and (d)(1) (i) of 5 129.105 as proposed, there was the following language setting forth the application of the standards to stormwater and other runoff: proceedings. (18) Comments were received from both Westgate Research and Houston Research disagreeing with the Agency's conclusions with respect to the feasibility of ultraviolet- stantiation of earlier preliminary evi dence that PCBs may bioaccumulate in the field at substantially higher rates than those experienced in laboratory tests upon which the Agency placed pri These standards or prohibitions apply to: ' * (B) All discharges from the manufacturing areas, loading and unloading areas, storage areas and other areas which are subject to assisted ozonation as a PCB treatment tech mary reliance in developing its proposed direct contamination by PCBs as a result nology. standards, additional evidence of the of the manufacturing process, Including but The Agency has re-evaluated its tech nical basis for UV-ozonation, in light of the present comments as well as the af fidavit and testimony of a UV-ozonation equipment manufacturer (Houston Re search) who furnished additional tech nical and cost information which is now in the hearing record. The Agency be lieves that the performance capability of UV-ozonation is now well documented in the record in this proceeding. (19) Dow Chemical urged the Agency to revise Its definition of PCBs to exclude chlorinated biphenyls "that have functional groups attached other than chlorine unless hazards of low-level exposure to PCBs to a wide range of organisms, and addi tional evidence of carcinogenicity. 3. Evidence presented at the hearings also showed that the impact of a prohi bition of PCBs on the industries In ques tion would be no greater than the im pact of the effluent standards proposed by the Agency on July 23, 1976. As dis cussed in the Findings above, this alters the picture from that which confronted the Agency at the time of proposal, when it appeared that the incremental Impact of a prohibition on discharge of PCBs by transformer and capacitor manufactur not limited to: (1) stormwater and other runoff; . Subsection (ii) of 'each of those sections then provided as follows: These standards do not apply to storm water runoff or other discharges from areas subject to contamination solely by fallout from air emissions of PCBs; or to storm water runoff that exceeds that from the ten year 24-hour rainfall event. For clarification, each of the subsec tions first mentioned above should be modified by inserting after the words "stormwater anc} other runoff" the fol lowing language: "except as hereinafter that functional group * * * Is determined ers would have a far more adverse eco provided in subsection (ii)." to be dangerous to the public health, safety nomic effect than standards at the levels 7. The toxic pollutant effluent stand and welfare * proposed. As set forth In the Findings, ards proposed by the Agency for PCBs, The Agency's definition of PCBs Is "a mixture of compounds composed of the biphenyl molecule which has been chlo rinated to varying degrees." The biphenyl molecule has a total of ten carbon-hydro gen bonds at which chlorine substitution is possible. The exclusion suggested by tlie reasons for the concern I expressed in the preamble to the proposed stand ards regarding such incremental Impact (which led the Agency to not propose a prohibition at that tiriie on PCBs In the discharges from capacitor and trans former manufacturers (41 FR 30474-' 30475)) have largely ceased to exist. with the foregoing modifications, ate fully supported by substantial evidence on the record as a whole. No further modification of such standards is justi fied "based upon a preponderance of evi dence" adduced at the hearings within the meaning of section 307 (a 1 (2) of the Act, and accordingly the standards, with Dow is determined by the Agency to be 4. Based upon a preponderance of the the foregoing modifications, should be unnecessary and inappropriate. evidence on the record adduced at the promulgated. FEDERAL REGISTER, VOt. 42, NO. 22--WEDNESDAY", FEBRUARY 2, 1977 Dsw 360956 STLCOPCB4097574 RULES AND REGULATIONS .. 655a ' S. Under section 307(a) (6) of the-Act, composed of the biphenyl molecule which from areas subject to contamination toxic pollutant effluent standards are to has been chlorinated to varying degrees. solely by fallout from air emissions of be complied with "in no case more than . 3. Subpart A of Part 129 is further PCBs; or to stormwater runoff that ex- one year from the date of such promul amended by adding a new 129.105 to cee<ls that from the ten-year 24-hour gation." Although I have the authority read rs follows: rainfall event. under that section to require compliance with these standards in a shorter period of time, it is my conclusion that the full statutory period should be allowed to enable plants to either phase out their use of PCBs, convert to substitutes, make appropriate technological or process changes, or take such other steps as they may decide upon in order to achieve compliance. 9. It is my further conclusion, based upon the Findings set forth above and the evidence of record, that the stand ards as thus promulgated fully satisfy the requirements of section 307(a) of the Act, that compliance therewith is achiev able within the prescribed time frame, and that the standards which are prom ulgated at this time are not likely to cause serious adverse economic impact to the Nation or to the industries which are subject to their provisions. Effective date: The amendment as hereinafter promulgated will become ef fective February 2, 1977. Due to the op eration of 129.8, the compliance date for the standards promulgated below will be February 2,1978. 129.105 Polychlorinated (PCBs). liinhciivls ' (a) Specialized definitions. (1) "PCB Manufacturer" means a manufacturer who produces polychlorinated biphenyls. (2) "Electrical capacitor manufactur er" means a manufacturer who pro duces or assembles electrical capacitors in which PCB or PCB-conlalnlng com pounds are part of the dielectric. (3) "Electrical transformer manufac turer" means a manufacturer who pro duces or assembles electrical transform ers in which PCB or PCB-contahiing compounds are part of the dielectric. (4) The ambient water criterion for PCBs in navigable waters is 0.001 pg/1. (b) PCB Manufacturer--(1) Applica bility. (i) These standards or prohibi tions apply to: (A) All discharges of process wastes; (B) All discharges from the manufac turing or incinerator areas,, loading and unloading areas, storage areas, and other areas which are subject to direct contamination by PCBs as a result of the manufacturing process, including but not limited to: _ (2) Analytical Method 'Acceptable. Environmental Protection Agency method specified in 40 CFR Part 13C, except that a 1-liter sample size is re quired to increase analytical sensitivity. (3) Effluent Standards--(1) Existing Sources. PCBs are prohibited in any dis charge from any electrical capacitor manufacturer; (ii) New Sources. PCBs are prohibited in any discharge from any electrical capacitor manufacturer. (d) Electrical Transformer Manufac turer--(1) Applicability. (i) These standards or prohibitions apply to: (A) All discharges of process wastes; and (B) All discharges from the manufac turing or incineration areas, loading and unloading areas, storage areas, and other areas which are subject to direct contamination by PCBs as a result of the manufacturing process. Including but not limited to: (f) Stormwater and other runoff except as hereinafter pro vided in subparagraph (ii); and (2) Water used for routine cleanup or clean up of spills. (ii) These standards do not apply to stormwater runoff or other discharges Dated: January' 18,1977. . Russell E. Train, Administrator. (1) Stormwater and other runoff ex cept as hereinafter provided in sub paragraph (ii); and (2) Water used for routine cleanup or from areas subject to contamination solely by fallout from air emissions of PCBs; or to stormwater runoff that ex ceeds that from the ten-year 24-hour 1. In 40 CFR Part 129, Subpart A (as cleanup of spills. rainfall-event. promulgated at 42 FR 2588 et seq. Jan (ii) These standards do not apply to ' (2) Analytical Method Acceptable. En uary 12, 1977, and amended at 42 FR stormwater runoff or other discharges vironmental Protection Agency method 2617 et seq. January 12, 1977), the table of contents is further amended to read as follows: Subpart A--Toxic Pollutant Effluent Standards and Prohibitions from areas subject to contamination solely by fallout from air emissions of PCBs; or to stormwater runoff that ex ceeds that from the ten-year 24-hour rainfall event. specified in 40 CFR Part 136, except that a 1-liter 'sample size is required to in crease analytical sensitivity. (3) Effluent Standards--(i) Existing Sources. PCBs are prohibited in any dis Bee. 129.1 1292 1292 129.4 129.5 Scope and purpose. Definitions. Abbreviations. Toxic pollutants. Compliance. _ . (2) . Analytical Method Acceptable-- charge from any electrical transformer Environmental Protection Agency meth manufacturer; (ii) New Sources. PCBs od specified In 40 CFR Part 136 except are prohibited in any discharge from . that a 1-liter sample size is required to increase analytical sensitivity. any electrical turer. transformer manufac 129.6 Adjustment of effluent standard lor presence of toxic pollutant in the Intake water. 129.7 Requirement and procedure lor es- tabllshlng a more stringent efflu- - ent limitation. 129.8 Compliance date. 129.9-129.99 [Reserved] 129.100 Aldrln/dieldrin. . 129.101 DDT. DDD and DDE. 129.102 Endrln. 129.103 Toxaphcne. 129.104 Benzidine. 129.105 Polychlorinated Biphenyls (PCBs). AtrrnORiTT: Sec. 307, 308, 501, Federal Wa ter PoUutlon Control Act Amendments of (3) Effluent Standards; (i) Existing Sources. PCBs are prohibited in any dis charge from any PCB manufacturer; (ii) New Sources. PCBs are prohibited in any discharge from any PCB manufac turer. (c) Electrical Capacitor Manufactur er--(1) Applicability, (i) These stand ards or prohibitions apply to: (A) All discharges of process wastes; and (B) All discharges from the manufac turing or incineration areas, loading and unloading areas, storage areas and other (e) Adjustment of effluent standard for presence of PCBs in intake water. Whenever a facility which is subject to these standards has PCBs in its effluent which result from the presence of PCBs In Its Intake waters, the owner may ap ply to the Regional Administrator (or State Director, if appropriate), for a credit pursuant to the provisions of 5 129.6, where the source of the water supply is the same body of water into which the discharge is made.. The re quirement of subparagraph (1) of 129.6(a), relating to the source of the water supply, shall be waived, and such facil 1972 (Pub. Ii. 92-500, 86 Stat. 816, (33 UJS.C. areas which are subject to direct con ity shall be eligible to apply for a credit 1251 et seq.)). tamination by PCBs as a result of the under. 129.6, upon a showing by the 2. Subpart A of Part 129 is further manufacturing process, including but not owner or operator of such facility to the amended by adding a new paragraph (f) limited to: Regional Administrator (or State Direc to 129.4 to read as follows: (1) Stormwater and other runoff ex tor, if appropriate) that the concentra 129.4 Toxic pollutants. * (f) Polychlorinated : (PCBs) --polychlorinated Biphenyls biphenyls cept as hereinafter provided in subpara graph (ii); and C2) Water used for routine cleanup or cleanup of spills. (ii) These standards do not apply to tion of PCBs in the intake water supply of such facility does not exceed the con centration of PCBs In tlie receiving water body to wlilch the plant discharges its effluent. (PCBs) means a mixture of compounds stormwater runoff or other discharges (FR Doc.77-8024 Filed 2-1-77;8:45 nm] FEDERAL REGISTER, VOL. 42, NO. 12--WEDNESDAY, FEBRUARY 2, 1977 . .' ,t OSVM 360957 STLCOPCB4097575