Document O17dxj3B3BgN5rE7vk2DD1EmL
2400F
Johns-Manville's Modern Research Center and Manufacturing Plants Combine to Produce Insulating Fire Brick and Refractories of Highest Quality and Top Value
JOHNSMANVJLLE
iN THB REFRACTORIES LABORATORY
Optical pyrometer and other temperature*measuring instruments are used by ceramic engineers in test furnaces capable of maintaining up to 3000F. In illustration below, an insulating fire brick designed to withstand very high heat is being tested under simulated service conditions.
JOHNS-MANVILLE RESEARCH CENTER
The Johns-Manville Research Center (left), near Manville, New Jersey, is one of the country's largest and most fully equipped groups of buildings of its kind, with a large staff of scientists, engineers and technicians.
A special refractories laboratory with the most advanced testing equipment is located at the J-M Research Center. There, ceramic engineers regularly test the performance of all J-M refractories under conditions closely simulating those of high tempera ture service in the field. Chemical as well as physical tests are made, and individual raw materials are subjected to scientific analysis. Evaluations are also made to determine the optimum balance of refrac tory properties.
There, too, comparisons of different formulations and blends are continually checked for development of new refractories. Tests are also made to determine new uses for established J-M refractories in order to meet present production requirements. Special test ing furnaces are available for this research, as well as the most advanced apparatus for temperature measurements, microscopic studies and X-ray.
The ceramic engineers also carry out research assignments related to specific customer problems. This broad research program plays a major part in Johns-Manville's ability to offer exactly the right insulating fire brick and refractory-the most eco nomical and efficient castable, gunning mix, light weight aggregate, mortar or patching material--for a given service.
filie's cturin ire Bn iualit)
TWO MODERN PLANTS TO SERVE YOU
Johns-Manville's modem refractories plant at Zelienople, Pa. (above), is one of the two plants that manufacture J-M insulating fire brick. This plant, and the one at Lompoc, California, are geographically situated to supply industry with the most complete line of insulating fire brick to meet the diversified requirements of modem furnace construction.
At Zelienople's control laboratory, trained cera mists continually conduct physical and chemical tests to insure product uniformity and high quality. This control is of paramount importance in these days of higher operating temperatures and mount ing operating expenses. It is important whether you use insulating fire brick, castable, gunning mix, bonding mortar, patching material or lightweight fill.
At Lompoc, California (below), in an area once submerged beneath the sea, Johns-Manville owns and works the largest and most uniform deposit of diatomite --the fossilized remains of microscopic marine plants ( diatoms i which died millions of years ago. From it, the Lompoc plant manufactures three types of Sil-O-Cel insulating brick used for back-up insulation behind refractory fire brick linings or behind insulating fire brick linings.
TABLE OF CONTENTS
Page
INTRODUCTORY
INSULATING FIRE BRICK AND SIL-O-CEL INSULATING BRICK
2-5
. . -...sr/nr Firt brick General Information Specification Data Method of Production
Typical Uses Heat Losses Table...................... Standard Shapes ...
Insulating Brick
General Information Specification Data Standard Shapes
>peciai Shapr- .
.
I'aikagmg and Paiieticing
I /instruction Details
Straight Walls .
...
Curved Walls
Division Walls
Sprung Arches
Domes and Arches
Suspended Arches and Walls
Periodic Kiln Domes
... ... ...
HYDRAULIC-SETTING REFRACTORIES Castables and Gunning Mixes
6- < S-9 10-11 12-15 20-21 22-23
16-17 18-19 22-23
24
24-25
26-27 26 29 30 31
31-32 32-33
.'.:r,,cu::i"'
34-35
H-o-.h
General Information Specification Data Application Instructions
36 36-37 36-39
H .::ccreU General Information Specification Data Application Instructions
.
40 40-41 42-43
REFRACTORY BONDING MORTARS
icui:44
v \-Mix n. .4 /' -x.-r.'iI' ( muniBiakite. Super Blakite. Hellite andNo. 2u
44
If \. H`ir-x.!'!l' < i No. 31 and No. 32
44
If. A: - x. rtn.L' l
No. 26
44
/'c: t uc. /.;.....
LIGHTWEIGHT REFRACTORY
AGGREGATES AND FILLS
' rc' I
a:,. '
A '!'.:
CERAFELT REFRACTORY FIBER FELT
7.......-
.m;:.
T".u _______ GLOSSARY OF STANDARD TERMS
45
46 46-47
46 48 46 49-51
insulating Fire Brick and Sil-O-Cel Insulating Brick
M---------------
JOHNS-MANVILLE INSULATING
FIRE BRICK PROVIDE
UNSURPASSED HEAT-CONTROL
EFFECTIVENESS TO 3000F
Johns-Manville provides industry with the most complete line of insulating fire brick and lightweight refractory aggregates, fills, and castables for tem peratures through 3000F. J-M INSULATING FIRE BRICK--Produced from high quality refractory clays. All six types contain a care fully graded organic filler which is burned out during manufacture, resulting in a uniform, controlled pore structure. Each insulating fire brick or shape is ac curately ground to size.
With six types of top-quality fire brick. JohnsManville offers operators and builders of high tem perature equipment the opportunity to use the one insulating fire brick that is right for a given service.
Each J-M insulating fire brick has the correct balance of thermal, chemical and physical properties for its recommended use. In addition, J-M insulat ing fire brick has high purity flow reducible oxides >. making them adaptable for use in prepared atmos phere furnaces and special ceramic kilns that use salt glazing processes. All six types have light weight, low conductivity and high structural strength for the efficient and economical control of heat.
J-M insulating fire brick are used as refractory lin ing or as back-up insulation behind other refractory protection. Their light weight and high insulating value make possible thinner furnace walls, improved efficiency and lower operating costs. Furnaces can be brought up to operating temperatures with un usual speed, thus resulting in increased production.
COMPLETE LINE OF INSULATING FIRE BRICK The six types of J-M insulating fire brick with their respective temperature limits are described below. The weights are approximate.
JM-3000 to 3000F - A high temperature insulating brick made for back-up or exposed use. This brick is especially adaptable for use in forge furnaces, ceramic
6
Inins, ohpmiefll process furnaces and other types of high'temperature equipment operating above JM-28'8 temperature range. JM-3000 has excep tional service advantages in many operations at lower temperatures where regular or special fire brick is ordinarily used (3.8 lb. per brick).
JM-28 (to 2800F)--With its comparatively light weight of 3.4 lb. per brick and high spalling re sistance, this brick can be used as insulating fire brick or back-up insulation in enameling furnaces, forge furnaces, soaking-pit covers, ceramic kilns and other locations where it will not be subjected to temperatures above 2800F.
JM-26 (to 2600F) --Combines high spalling resist ance and light weight (2.8 lb. per brick). It is suit able for use as an insulating fire brick or back-up insulation in calciners, ceramic kilns, heat-treating furnaces and imilar equipment where the tempera ture on the JM-26 brick does not exceed 2600F.
JM-23 (to 2300F) --A lightweight high purity brick (1.7 lb. per brick) with low iron content which pro vides high resistance to the deleterious effects of prepared atmospheres. It is designed for direct ex posure or back-up insulating in such equipment as oil heaters, ceramic kiln domes, drawing furnaces, electric furnaces and hardening furnaces.
JM-20 (to 2000F)--This is a high purity brick (1.6 lb. per brick) with the perfect balance of chemi cal and physical properties for effective heat control in prepared atmospheres. It is made from carefully selected materials with an extremely low iron oxide content. The brick has high cold-crushing and hotload bearing strength. It is used in annealing ovens and various other types of equipment such as car bonizing furnaces, lehrs, normalizing furnaces, oil stills and heaters, and for stack linings.
JM-1620 (to 1600F exposed, to 2000F back-up) -- This insulating fire brick (1.5 lb. per brick) is recom mended for use as a direct refractory lining for tem peratures not over 1600F, and for service behind fire brick or other insulating fire brick where the temperature on the JM-1620 brick will not exceed 2000F. It is used in such equipment as core ovens, hot blast mains, producer gas mains, regenerators, recuperators, stress-relieving furnaces and similar equipment.
t
Physical Properties*
JM-3000 JM-26 JM-26 JM-23 JM-20 JM-1620
Temperature Limit
3000F-- 2800F" 2600F-* 2300F" 2000F" 2000F--' 1600F-
Approximate Density, pet
65 58 51 31 29 27
Transverse Strength. psi
200 175 140 140 105
95
Cold Crushing Strength, psi
400
300 210 210
155
145
Linear Shrinkage, percent
T0.B at 3000F
1.4 at 2750F
1.0 at 2600F
0.1 at 2300F
0.0 at 2000F
0.0 at 2000F
Reversible Thermal Expansion, percent
0.65-0.75 0.65-0.75 0.65-0.75 0 5-0 6 0.5-0.6 0.5-0.6 at 2000F at 2000F at 2000F at 2000F at 2000F at 2000F
The figures given m this tepie are average values obtained m accoroanee witn acceoted test methods Back-up or exposed Bach-uo only ?4-nr Simulative Service Panel test, an others 24-nr soaking period
Typical Chemical Analysis
Material Composition
JM-1620
JM-20 and JM-23
JM 26
SiOTiO; Fe:0: Al j0; CaO MgO Na;0 K;0 P50. Al Metal
43.0 1.3 0.5
36.9 17.6
.06 .03 .21 .13 -
44.2 1.29 0 46
38.0 15.2
.06 .02 .27 0.16 -
57.4 1.7 .8
39.7 0.2
.1 .1 .1 -
JM-26
39.0 1.25 .5
59.0
-
-
.19 .06
-
-
JM-3000
29.4 1.0 .71
65.6 0.3 0.5 0.1 0.1
-
3.6
Thermal Conductivity: BTU IN. PER SQ FT PER F PER HR
MEAN TEMPERATURE. F
JM-3000 JM-28 JM-26 JM-23 JM-20 JM-1620
500 3.22 2.55 2.22 1.01 0.95 0.88
1000 3.30 2.80 2.44 1.18 1.11 1.05
1500 3.37 3 06 2.68 1.34 1.28 1.23
2000 3 46 3.32 2.93 1.50
-
Compliance with Government Specs
JM-20 complies with MIL-B-16305A. Class A JM-28 complies with MIL-B-16305A. Class B
fc 9
9
Streamlined methods cut production time and speed delivery of J-M Insulating Fire Brick in standard and many sizes of special shapes
In Johns-Manville's modem refractory plant at Zelienople, Pa., high quality insulating fire brick is made better and faster by an improved method dif ferent from the conventional process. With the J-M method, standard brick and a wide range of special shapes are cut out of fired slabs.
The slabs are molded, fired rapidly through tunnel kilns, then cut into the desired shape. Handling of the slabs throughout the process is easier, a more stable load is possible on the kiln cars, with uniform
temperatures and better spacing to permit bum-out.
Many shapes which normally have to be molded and processed as special items can now be produced directly from slabs. They are also superior to shapes made by joining individual brick.
This streamlined operation provides the flexibility and basis for giving quick shipment of high quality standard and special insulating fire brick shapes to J-M customers.
(1) Slinger machine throws selected mix from pug mill and forms continuous stiff column on pallets moving along molding conveyor.
(2) Sharp blades first trim top and sides of column, then cut it into slabs so that each slab is on a pallet.
CASTING METHOD
(JM-1620, JM-20 and JM-23)
(1) Blends of high purity refractory materials, setting agent and burn-out are thoroughly mixed with water in paddle-type mixer, then poured into a mold.
(2) When mix hardens, the mold is moved to the stripping machine where slabs are removed from mold and put on kiln car.
The two types of fired slabs receive the same finishing procedure after they are removed from the tunnel kiln. They are ground and cut into standard and special brick shapes by a sizing machine which slits the slabs to the proper width and length. The brick are then packed into cartons and stored until they are shipped by rail or truck.
10
IN THE FERROUS METALS INDUSTRY
Annealing furnaces Barrel furnaces Billet-heating furnaces Blast furnace stoves Butt weld furnaces Colorizing furnaces Carburizing furnaces Car top6 Case-hardening furnaces Controlled-atmosphere furnaces Crucible furnaces Electric furnaces Flues (high temperature) Forge furnaces Hardening furnaces Laboratory furnaces Malleableizing furnaces
IN THE NON-FERROUS METALS INDUSTRY
Die-casting machines Electrolytic cells (magnesium) Galvanizing and tinning furnaces Heat-treating furnaces Annealing furnaces Reduction pots (aluminum) Crucible furnaces (lead) Brazing furnaces
12
nsulating Fire Brick
Normalizing furnaces Open-hearth furnaces Plate-heating furnaces Pusher furnaces Radiant tube annealing covers Recuperators Rolldown furnaces Rotary hearth furnaces Sintering furnaces Slab-heating furnaces Soaking pits Soaking pit covers Spheroidizing furnaces Stress-relieving furnaces Tempering furnaces Walking beam furnaces
i-
J
M H 13
Typical uses for J.f
| IN THE PETROLEUM AND CHEMICAL INDUSTRIES
PETROLEUM INDUSTRY Hot air and gas mains Breechings Catalytic reformers Ducts Flues Oil heaters or furnaces walls, arch, floor Heai tor chambers Regenerators Stacks Stills Vessel linings
CHEMICAL INDUSTRY Ammonia reformers Calcining furnaces Carbon baking oven covers Driers High-temperarure pressure vessels Hot gas mains Rotary calciners and dryers Special process furnaces Stacks and breechings Sulphur furnace?
| IN THE CERAMIC AND GLASS INDUSTRIES
CERAMIC INDUSTRY Chamber kilns Tunnel kilns Shuttle kilns Rotary kilns Car seal backs Periodic kilns Movable hood kilns Procelain enamel furnaces Flues and stacks Controlled atmosphere kilns Calcining furnaces GLASS INDUSTRY Bending furnaces Flattening ovens Gas mains Glass tanks, regenerators, flues and uptakes Lehrs Ports
14
II
III Insulating Fire Brick
m
Boiler walls, floors, tops Breechings Ducts Flues Stacks Fireboxes
MISCELLANEOUS APPLICATIONS
Core-drying ovens Japanning ovens Enameling furnaces Bake ovens Burners Coke ovens Cross-over flues Domestic oil burners Furnaces Gas producers and mains
Heaters Incinerators Kilns Ovens Retort benches Stacks Stoves Gas generators Duct linings
Providing Good Insulating
Sil-O-Cel insulating brick is made in Johns-Manville's Lompoc, California plant, using selective blends of diatomaceous silica. This material contains millions of microscopic cells that offer maximum resistance to the fow of heat. Consequently, these high loadbearing brick are ideal for use behind fire brick at temperatures through 2500F.
Three types ofSil-O-Cel insulating brick are avail able to meet the varying temperature requirements encountered in back-up insulation service: Si-O-Cel Super, Sil-O-Cel C-22 and Sil-O-Cel 16L. All are used in boilers, stills, heat-treating furnaces, kilns, lehrs, flues, retorts, stacks and other types of hightemperature equipment. (Sil-O-Cel 16L insulating brick may also be used for exposed as well as back up service, i
Used as back-up insulation, Sil-O-Cel insulating brick make it possible to reduce the necessary thick ness of the exposed refractory as much as one-third. This results in a considerable saving in furnace wall construction for all types of high-temperature equipment.
Sil-O-Cel insulating brick are pressed, then dried and fired in tunnel kilns. They are pressed to size, not sized after firing, as is the case with J-M insulat ing fire brick.
THREE TYPES OF BRICK
The three types of Sil-O-Cel insulating brick are:
Sil-O-Cel 16L--Made from diatomaceous silica, molded and calcined. They serve for temperatures to 1600F, back-up or exposed. This type of Sil-O-Cel brick is one of the most efficient insulating brick obtainable and is used in preference to other types of Sil-O-Cel brick except where severe temperatures are encountered.
These brick have a cold crushing strength of ap proximately 350 psi, so they are amply strong for structural purposes. Owing to the extremely low reversible thermal expansion, less than 0.1 at 1600F, Sil-O-Cel 16L brick are particularly advantageous in building long-lasting refractory masonry. Because of this valuable property, 16L brick can also be bonded for direct exposure.
Sil-O-Cel 16L brick are finished so that accurate, smooth surfaces are assured. This enables the brick to be laid up with thin joints and permits bonding with the fire brick where required.
Value and High Strength . . .
a Sil-O-Cel C-22 -- An efficient, diatomaceous silica brick, pressed and calcined for use as a back-up in sulation behind fire brick or behind insulating fire
a brick where the temperature on the insulation will not exceed 2000F. In preventing transmitted heat loss. C-22 brick
a are three to four times as effective as fire brick in retarding heat flow through furnace walls. In other characteristics, they combine, to a remarkable de gree. all those qualities desirable in an ideal, general-
a purpose insulating brick. These brick have a cold crushing strength of about 700 psi. which is equivalent to over 50 tons per sq. ft.
a They are therefore especially recommended for locat ions where high load-bearing properties are essent ial.
a Sil-O-Cel Super -- A calcined type of Sil-O-Cel brick designed for exceptionally severe insulating serv ice where subjected to temperatures behind the
a refractory. These brick have a cold crushing strength of ap proximately 300 psi. which is equivalent to over 21 tons per sq. ft.
In many cases, it is possible to cut down on the thickness of first-quality fire brick when Sil-O-Cel
a Super brick are used. For instance, in equipment where Sil-O-Cel 16L would be used behind 1312" of fire brick. Sil-O-Cel Super brick could safely be used back of 9". or in some cases as low as 41 j" of refrac
a tory. thus making a considerable saving.
Johns-Manville Sil-O-Cel Insulating Brick
SIL-O-CEL INSULATING BRICK Specification Data
Physical Properties'
Super
C-22
1CL
Temperature Limit Approiimate Density Transverse Strength Cold Crushing Strength Linear Shrinkage
Reversible Thermal Expansion
2500F** 40 pet
90 psi 300 psi 2.0% at 2500F
1.3% at 2000F
2000F** 39 pet
115 psi
700 psi 0.8% at 2000F
0.7% at 2000F
1S00F***
34 pet
CO psi 350 psi 0.7% at 1600F
less than 0.1 % at 1G00F
'The fijures given m this table are average values obtained in accordance witn accepted test methods. "Bach-up only Bach-up or exposed.
Thermal Conductivity: BTU IN. PER SQ FT PER F PER HR
MEAN TEMPERATURE, F
500
1000
1500
Super C-22 16L
1.70 1.67 0.92
1.95 1.88 1.07
2.19 2.08 1.22
2000
2.45
-
-
Compliance with Government Specs Sil-O-Cel Super complies with MIL-6-16182B
Standard Sizes
TYPE Sil-O-Cel Super Sit-O-Cel C-22 Sil-O-Cel 161
SIZE Furnished in all standard 9-in. shapes of the 2 Vi and 3 in. senes, as well as special shapes.
Heat Losses, Heat Storage and
J-M Insulating Fire Brick and
HOT FACE TEM
Wall Thicknes
Construction
1000 1200
1400
1600 1800
HL JT ST HS HL JT ST HS HL JT ST KS HL JT ST HS W. JT
4#*JM 1620
169 -- 158 1175 214 -- 176 1440 263 -- 196 1740 314 -- 216 2050 -- --
4K'JM20
173 -- 163 1250 220 -- 183 1550 269 -- 202 1900 322 -- 222 2200 379 --
4V4'JM23
191 -- 171 1450 241 -- 191 1850 293 -- 212 2200 345 -- 232 2550 407 --
4K' 4Vi* JM 26
383 -- 243 2500 479 -- 274 3100 581 -- 303 3700 688 -- 329 4400 800 --
4WJM28
432 -- 260 2850 541 -- 292 3450 657 -- 322 4170 779 -- 349 5100 906 --
4V4' JM 3000
S15 -- 285 3300 639 -- 318 4100 768 -- 347 5000 900 -- 372 5750 1036 --
4#'FIRECLAY BRICK
974 -- 387 6300 1272 -- 430 8300 1596 -- 468 9400 1933 -- 510 10900 2259 --
4#'JM 1620+Hi'SX 122 418 141 1630 156 500 156 2070 191 585 171 2550 227 675 186 2980 -- --
4K'JM20+1H'SX
126 423 142 1790 159 506 157 2250 194 595 172 2740 231 686 187 3240 271 779
6*
4WJM23 + lH'SX
134 444 145 2070 168 531 161 2550 204 9 176 3150 242 712 192 3900 282 90S
4H'JM26+1K'SX
202 615 175 3660 252 735 196 4700 304 855 216 5770 359 975 235 6730 416 1096
4V4'JM28 + IK'SX
214 645 180 4260 267 771 202 5540 323 897 222 6600 381 1022 243 7860 441 1148
4M'JM3000+ lM'SX 230 684 187 4880 285 812 208 6250 341 938 229 7620 400 1063 249 9900 461 1196
9' JM 1620
87.7 -- 126 2220 110 -- 134 2740 135 -- 144 3310 162 -- 156 3990 -- --
9' JM 20
89J -- 125 2400 114 -- 136 2940 139 -- 148 3650 167 -- 160 4300 195 --
9' JM 23
99.7 -- 130 2900 125 -- 142 3500 152 -- 154 4100 181 -- 166 4940 211 --
9' 9* JM 26
207 -- 177 4700 257 -- 196 5700 310 -- 218 6800 365 -- 237 8100 422 --
9' JM 28
235 -- 119 5300 293 -- 211 6600 352 -- 233 8000 415 -- 254 9600 480 --
9' JM 3000
285 -- 206 6100 350 -- 232 7600 416 -- 2S5 9000 484 -- 276 10600 553 --
9' FIRECLAY BRICK 551 - 295 11400 703 -- 333 14600 868 - 366 17600 1047 - 395 21000 1238 --
9* JM 1620 + 3' SX
63.3 400 114 3320 79.5 478 122 4080 97.3 561 131 4950 116 646 140 5900 -- --
9' JM 20+ 3* SX
64.6 403 113 3480 81.6 485 121 4345 99.7 569 130 5335 119 656 139 6310 139 746
12'
9'JM-23+ 3' SX
69.0 425 115 4010 86.6 508 123 5090 105 594 132 6250 125 682 141 7340 145 772
9' JM 26 + 3' SX
106 596 133 7250 132 713 144 9350 158 830 156 11000 186 948 169 13200 216 1067
9' JM 28 + 3' SX
112 627 136 8480 140 750 148 10600 169 873 161 13100 198 997 174 15400 229 1121
9' JM 3000 + 3' SX
121 667 140 9720 150 792 153 12200 179 916 165 14700 209 1039 178 17600 240 1161
13K'JM 1620 + 3H'SX 45.5 346 105 4280 56.8 409 111 5540 69.8 478 117 6790 83.7 552 123 8060 -- --
13K'JM20+ 3K'SX
46.5 350 104 4900 58.8 418 110 6030 71.8 489 116 7310 85.6 564 123 8890 100 641
17'
13H'JM23+3K'SX
50.0 369 106 5530 62.8 440 112 7100 76J 513 118 8690 903 589 125 10200 105 666
13V4* JM 26+ 3M* SX
80.5 536 121 10000 100 640 130 12800 120 745 139 15600 142 851 149 18500 164 958
13K* JM28+ 3K'SX
86.4 568 123 11800 107 678 133 15300 129 789 143 18700 152 901 154 21800 176 1013
13K'JM3000 + 3K'SX 944 610 127 13700 116 723 137 17400 139 836 148 21100 162 947 158 24610 185 1058
HL - Hut Los at Study State Condition, BTU/SQ FT /HR. JT - Junction Temperature between Brick and Backup Insulation. F. * Ambient - 80 F, Still Air.
ST - Outside Surface Temperature, F. HS - Hut Storage, BTU/SQ FT.
20
I Outside Surface Temperatures of Walls
Superex Compared to Fireclay Brick
I
PERATURE*--F
I 1800 2000
2200
2400
2600
2800
ST HS HI n- ST HS HL JT ST HS HL JT ST HS HL JT ST HS HL JT ST HS
242 2550 ! <38
261 2900
252 2950 469 - 271 3350 533 - 290 3800
353 5000 917 - 374 5700 1040 - 394 6400 1168 - 411 7000 1300 -- 427 7600 --
373 5850 1040 - 394 6600 1179 - 413 7400 1324 -- 430 8200 1474 -- 447 8800 1627 - 465 9600 394 6600 1175 - 414 7400 1317 - 431 8400 1462 - 448 9200 1607 -- 465 10000 1754 - 482 11000 570 12700 2670 - 586 14100 3070 - 619 15500 3510 - 642 17200 3990 - 658 18700 4450 - 703 20500
203 3790 207 4350 254 7710 263 9030 268 10300
312 873 219 4330 324 899 223 5000 476 1216 273 8770 505 1273 282 10300 523 1308 287 11600
368 994 238 5550 538 1336 291 9650 572 1398 300 11400 588 1428 304 12700
604 1455 308 10700 642 1522 318 12700 656 1546 321 14200
673 1574 325 11800 716 1645 335 13800 726 1662 336 15300
793 1766 350 14900 798 1775 351 16400
172 4900 226
185 5600
179 5700 242 - 192 6400 275 - 205 7200
257 9400 482 - 275 10600 543 - 292 12000 607 -- 309 13600 673 - 325 14600 -
274 11000 547 - 293 12600 617 - 312 14000 689 - 329 15600 764 - 345 16800 841 - 360 18400
295 12400 623 - 314 14000 694 - 330 16000 767 -- 346 17600 840 - 361 19200 915 - 374 21000
421 23400 1440 - 445 26000 1653 - 469 29000 1871 - 497 33000 2090 - 533 35000 2305 - 584 39000
148 7400 151 8410 181 15300 187 17700 191 20200
160 838 157 8290 166 864 160 9920 246 1186 193 17200 262 1245 199 20100 272 1282 203 23100
189 957 170 10800 278 1305 206 19300 296 1369 212 22200 304 1401 216 25200
311 1424 218 21300 331 1493 225 24300 338 1518 228 27400
345 1543 231 23400 368 1616 238 26500 373 1634 240 30500
406 1738 251 29700 409 1749 252 32600
130 10100 132 11600 159 21600 164 25000 168 28600
116 720 137 11700 121 746 139 13200 187 1065 169 24400 200 1126 174 28100 209 1167 178 32600
137 826 147 15100 210 1173 179 27500 226 1239 185 31200 234 1276 188 35800
235 1281 189 30100 252 1352 196 35000 259 1383 198 39500
261 1389 199 32900 280 1465 206 38100 285 1489 208 43500
308 1578 217 41200 312 1593 218 46600
)
I 21
Standard Shapes of J-M insulating
i
r
NO 1 WEDGE
22
NO. 3 ARCH
T
Fire Brick and Sil-O-Cel Insulating Brick
V -\r
EDGE SKEW
FEATHER EDGE
23
Types of Straight Wall Construction
RECOMMENDED CONSTRUCTIONS-The most common constructions where J-M Insulating Fire Brick is used are those consisting of all headers or of alternate header and stretcher courses. These con structions are recommended unless other factors in fluence the type of wall used.
PERMISSIBLE UNSUPPORTED HEIGHT- Unsup ported wall 4^' thick, should be no higher than 3 ft. Unsupported wall 9' thick, tied in by combinations of header and stretcher courses, can be used up to 8-ft. heights; 1314' walls under same conditions are suitable up to 12-ft. heights.
HEADER COURSES
ALL HEADERS --Many 9'-thick Insulating Fire Brick walls are built of all-header courses. This is especially true of bell-type annealing furnaces. Ad vantages are a reasonably stable wall with the back side of all brick under comparatively low tempera tures. Hence, a preferred construction for walls
operating near their temperature limit. MAINLY OF HEADERS -- This type of wall possesses many of the advantages of one constructed entirely of headers, but has greater rigidity. This wall is usually laid with three to four header courses to each stretcher course.
STRETCHER COURSES
ALL STRETCHERS--Not very rigid and is not rec ommended except for walls under 3 ft. in height, or walls having other means of support, such as sus pended walls or veneer courses between a heavier wall and exterior casing. Even for walls under 3 ft. high other types of construction are preferable.
MAINLY OF STRETCHERS-This type of wall is ex tensively used where the brick are subjected to slagging or other erosive action. The advantage of this type is that the exterior face can be repaired by applying a 4 J o'-skin wall tied into the remaining brick work.
ALTERNATE HEADERS AND STRETCHERS--
Walls of both 9' and 1312' thicluiesses constructed of alternate headers and stretchers make a very stable
wall and is considered "good practice." Walls of this type are most common in mill-furnace construction, especially where dense fire brick is used.
26
- Unsupihan 3 ft. binations sed up to itions are
oossesses . entirely i wall is urses to
vaU is exiected to .image of paired by emaining
ills of this itruction,
m
m
Curved Walls
Most curved walls are used as linings of stacks or of circular-pit type furnaces. An exception is sometimes encountered in the side walls of furnaces made in the form of a curve to give greater stability than can be obtained with straight walls.
ADVANTAGES--A properly constructed curved wall is much more stable than a straight wall, thickness for thickness. Therefore, such walls can generally be constructed higher than straight walls.
When walls of sufficient curvature are enclosed in a casing such as in a stack lining . the wedging action of the brick prevents them from falling toward the
inside and the casing prevents them from falling outward, so the only limiting factor on height is the ability of the brick to carry' the weight of the over head material under operating conditions.
BRICK SHAPES--Curved wall sections are usually constructed by using circle brick and key brick, either alone or in combination. When necessary, arch and wedge brick can also be used, but are much less desirable.
When using insulating fire brick to make curved walls or roofs, it is always preferable to use specially cut brick to fit the curvature rather than a combina tion of straight brick and standard shapes as is customary practice with dense fire brick.
CONSTRUCTION GUIDE
Wall Thickness Recommended Brick
Other Possible Brick
** * ` "
9"
13Vi" and heavier
Circle Key Key
Arch brick are sometimes used but are not recommended
Combination ot circle and key brick may be laid uc. using any combina tions used for straight walls
Same as for 9" brick If necessary, wedge brick can be used on low walls, but their use is not recom mended
MAXIMUM HEIGHT--On walls where the curvature is sufficient to make the wall self-supporting, the height is limited only by the ability of the brick in the lowest course to carry the weight of the courses above. Since the crushing strength of all refractories varies with temperature, the safe height of such linings will depend upon the type of brick used and operating temperature.
Division Wails
Occasionally, furnaces are designed having heating chambers side by side, with a common wall between. This construction is usually more expensive than two separate walls and is subject to the weaknesses outlined below.
OPERATING TEMPERATURE--In the ordinary single furnace, only one side of each wall is heated, thus resulting in a temperature drop from the inside to the outside. The outside of the brick remains strong, while the hot exposed sections may be approaching their softening point.
TYPE OF BRICK -- Because of the high operating temperature, a higher quality brick may be required for a division wall than on the remainder of the furnace. In addition, the brick in the interior of the division wall will be subjected to the same tempera ture as the exposed brick, so the same high quality brick used on the exposed portion should also be used in the center of the wall.
CONSTRUCTION -- In Fig. 1, the skewbacks are sup ported by a solid course of refractory brick. Fig. 2 illustrates the skewbacks supported by channels resting on brick spacers. This construction, either with or without flues, permits one arch to be repaired without disturbing the other. However, it is neces sary to space out the brick between the channels to dissipate the heat.
The air flues in the center of the division walls Fig. 31 allow the heat to escape to the outside air. They are formed when laying the brick, providing openings that are either vertical or horizontal, or both. Where horizontal flues are used alone, air is frequently blown through by mechanical means or by connection to a vertical flue or stack at one end.
THICKNESS --The thickness of division walls should be at least 4H' greater than for ordinary walls. If the wall is to support two sprung arches, the thick ness should be no less than the width of the two skewbacks involved.
29
BRICK SPACER AT INTERVALS
FLUE AT BOTTOM FIG. 2
1 ___1 _ _____ 1
1 1 11
11 l
1 1
1 1 .1 1 --1____ 1
FIG. 3
Sprung Arches
Sprung arches are the most common type of arch used in furnaces. They are fairly easy to erect and require the least elaborate mechanical means of
support. These arches rest at both ends on skewbacks which
transmit the arch stresses to the supporting parts of the furnace. The "built-up" skewback of cut stand ard 9-inch brick is the most accepted form, but the special one-piece skewback is also widely used. Since movement of the skewbacks may cause failure of the arch, furnaces must be rigidly constructed.
Sprung arches for direct exposure can be made from insulating fire brick or dense fire brick. The same practices governing proper arch construction apply to both types of brick. Although insulating fire brick may have less strength per unit of weight than some types of fire brick, they serve for as wide a span, because any deficiency in strength is overcome by lower weight and more uniform sizing of the insulat ing fire brick. This uniformity results in an even distribution of the load over all the brick in the arch.
BRICK SHAPES USED--Since dense fire brick are moulded to size and burned and cannot be machined readily, standard sizes were adopted for arch, wedge and key brick: designating them No. 1, No. 2, and No. 3 arch. Arches are built using a combination of No. 1. 2. and 3 brick and straights in quantities suffi cient to turn a given circle.
J-M Insulating Fire Brick, however, are machined to size after firing and are furnished with the correct taper for any specific arch. This results in a sturdier construction and simplifies the laying operation, as only one brick size is involved, although, when nec essary. the standard shapes can be used. The stand ard shapes used for various arch thicknesses are:
Arch Thickness
Shapes and Combinations
4V4" 6V" 9"
Over 9"
Arch brick ora combination of arch and straight. Large 9" arch or combination of large 9" arch and large 9" straight.
Wedge brick or a combination or wedge and straight. (Con struction of key brick or combination of key and straight are not common as the load is placed on the narrow face of the brick. This construction is only used where special conditions make it desirable.)
Constructed, necessarily, of special wedge brick. However, 13V4" wedge brick are furnished as standard by some manu facturers.
RISE OF ARCHES--The minimum rise for an arch should be 11^2' per foot of span. Arches with a rise of 1.608' per foot of span are common, as this rise results in an included angle of 60 degrees with the inside radius equal to the span. Wherever possible, however, for wide spans, it is recommended that the rise be made at least l3.*' per foot of span.
The maximum rise of an arch has generally been set as 3' per ft. A rise of 3' per ft. will be sturdier than one with less rise. Therefore, as great a rise as possible is recommended within the limits of 134'' minimum to 3' maximum per foot of span.
TYPES OF SPRUNG ARCHES-The "bonded" arch is the most commonly used arch and the best for most conditions, because the entire construction is tied together. If one or several bricks fail in the bonded arch, the load will be taken by the brick on either side and the arch will remain in place until replacement is made.
With the "ring" type arch, however, if one brick in a ring fails, the entire ring drops, thus making repair difficult. The chief advantage of this type arch is ease in laying, especially when a combination of standard shapes is used.
The "ribbed" arch is used chiefly for open hearth furnaces. The ribs strengthen the arch and give it stability after the intermediate brick have eroded away.
"Jack" arches are very seldom used except over openings, since they are costly and possess few advantages over the other types.
30
Domes and Crowns
A dome or crown differs from a sprung arch in that a sprung arch describes a portion of a cylinder, while a dome or crown describes a portion of a sphere.
The recommended thickness of a J-M Insulating Fire Brick dome is 9', made up of key brick used in combination with wedge key and arch key brick. Each brick is color coded at the factory on the large end of the shape for quick identification on the job.
All brick have the same key cut to accommodate the difference between the inside and outside arch lengths of the dome. In addition, some brick also have a wedge taper and others an arch taper. The brick are laid up in AV2' rings until the dome is closed except for the hole in the center. During con struction. a template is frequently used. This con sists of a wood frame attached to a pipe vertically positioned directly below the top of the dome. The template is free to rotate around the vertical pipe and. having a shape that conforms to the final inside surface of the dome, acts as a guide for each brick course.
TYPICAL DOME SKEWBACK
The drawings (at right i show a typical dome skewback. These skewbacks are the same as those used in sprung arches except that they are tapered so they can be laid in a circle of the proper diameter.
Suspended Arches and Walls
A suspended arch or wall is one which is not selfsupporting. but which is held in place mechanically. This support is usually obtained by metal hangers fitting into holes or grooves, or over projections on the brick. In some constructions, special ceramic shapes are also used for this purpose.
While there are literally hundreds of different types of suspended arch constructions, a few of the more popular types are: Pipe, Tee Bar, Rod, Special Formed Member, and Ceramic Hanger.
There are two types of suspended walls: Air-cooled --Where there is a lane for the flow of air directly in back of the refractory; and Insulated--Where in sulation is placed directly behind the refractory. Both the air lane and the insulation serve to protect the metal structure from high temperatures.
WHY USED --The main reasons for using suspended arches and walls are:
111 It is possible to erect wide span flat arches and thin, lightweight walls with high thermal effi ciency and structural stability. The height of the wall or width of the arch is limited only by
UinUriMuO'CF*OCRutthtiso C*>atp
MARK
NUMBER DIMENSION
REQUIRED
X
Dimension Y
A
636
2.34*
219*
B
MB
2.2B*
2.13*
C 1B3 232" 2.07*
0 BO 2.15' 2.01-
E 69 2.10* 196F 5? 2-01* IBB*
G
45
1.B9*
ITT-
N
35
1 66*
1.57*
J
24
1.29*
131*
10 STRAIGHT BRICK 9' a 4H* 2H* REQUIRED FOR CENTER PLUG-MARK'S APPROXIMATELY 900 LB OF 1626 CEMENT REQUIREO
s DETAIL OP MARK -K14* REQUIRED
NOTES ALL MICK TO BE MARKED WITH MARK LETTER QUANTITIES GWEN INCLUDE NO ALLOWANCE FOB WASTE
31
the ability of the structural members to carry the load.
(21 To permit the use of special furnace designs making possible the use of special conveying mechanism or control of combustion or radia tion. With self-supporting walls and sprung arches or domes, the variation in furnace shapes is quite limited, while with suspended construction, a shell ofany desired size or shape may be constructed of structural steel and then lined with refractory.
(3> A saving in overhead space, especially on wide-arch spans.
(4' To permit the construction oflarge, removable sections.
C5i To act as occasional anchorage in otherwise self-supporting walls.
ADVANTAGES Repair costs are generally lower, because of the ease with which brick can be removed and replaced, and also because repairs can be confined to the brick which are actually damaged. In some cases, there is the further advantage in that hot repairs can be made without loss of production.
In suspended arches, the main load is carried on the structural steel while the refractories carry rela tively light loads and therefore have less tendency to deform at high temperatures than in other arch and wall structures. Definite allowance can conveniently be made to take care of thermal expansion, both horizontally and vertically, to avoid stresses which can cause breaking. Provision can easily be made for ventilation or for water-cooling as conditions may require.
If the weight of the roof is supported by suspended construction, the top courses of the walls may neces sarily be tied to the furnace binding by metal hangers or clips to keep the walls from bowing inward.
DISADVANTAGES
The chief disadvantage to suspended construction is its cost. For equal thickness, the cost of most sus pended construction will be higher than the cost of self-supporting brickwork. This is brought about not only by the cost of supporting steel work but also by the additional cost of necessary special shapes. Many suspended constructions also are unable to stand as much mechanical abuse as selfsupporting brickwork.
THICKNESS The thickness of suspended-arch and wall construc tion is limited only by the manufacturing limits of the brick shapes. Most common thicknesses in in sulating refractories are 4^' and 9'. Very few sus pended arches or walls are constructed with a thick ness less than 412'` or more than 9'.
32
SIZE OF UNITS
Brick shapes for suspended arches and walls require absolute uniformity of size to assure close fitting and to eliminate the possibility of air infiltration and gas leakage. The most common insulating fire brick unit for this construction is the 2>' series straight, although many suspended constructions employ 9' large brick. The large brick are used to reduce the amount of steel work and hangers required. In most cases, the use of large brick results in a lower over all cost of steel, labor and refractories than when the 2l/2* size is used.
NOTE: Where suspended construction is used, only one insulating fire brick of sufficient thickness to obtain the desired insulating effect should be used. Do not use a combination of insulating refractories and back-up insulation, as such construction will dam up the heat on the hangers and cause trouble.
Periodic Kiln Domes
Round periodic kilns are widely used in structural clay plants which manufacture such products as ceramic tile, brick, pipe and other clay ware. These kilns vary in diameter from 15 to 40 feet, typically constructed as shown in figure 2. The rise is usually 2> 2'to 3'per foot of span. The sidewalls are normally constructed of dense fire brick although a layer of insulating fire brick is recommended to effectively reduce heat transfer through this area. The kilns are either coal, gas, or oil fired.
Calculation of Brick Quantities and Shapes
1. Refer to Figure 1, "Kiln Dome Layout For Calcula tion Data." The following calculations are based on the trigonometric relationships shown in this figure.
2. Determine the length of the outside arc Lo from the t of the dome to the base of the dome. L* o (inch, es) = 2--i-r--R--n---x--l-oggD^so-m---e---A--n-gle
3. Since the brick are laid the
way, the total
number of courses is 47.-5=. The center hole will reduce the number of courses just calculated by J-2 its diameter in inches divided by 4.5.
4. Determine the angle a formed by a single brick
(projected to the dome center). See Figure 1.
g 4.5
360 (4.5)
360 = 2 i Ro' * 2 r Bo
5. At this point, the total number of courses as de termined in step 3 may be checked by
^ Dome Angle _ Total number of courses (leas
center hole).
6. All brick in the dome are key cut, and the key taper
is determined by
X Bj 4.5 * E? A
45ft = Bo
-
(4.5' - X')
Key cut on all brick.
7. Set up a table of eleven columns across and of a length equal *to the number of courses. The first column indicates the course number.
8. In Column 2 list the angle between the vertical / of the dome and the farthest edge of each course
(see Figure 1). This angle is Hof the Dome Angle minus the sum of 's to each course. For example, for a 120 Dome, course No. 1 is 60.000 -- 0 -- 60.000; Course No. 2 is 60.000 minus ; Course No. 3 is 60.000 - 2 a; etc.
9. Convert the decimal portion ofeach angle to minutes of a degree to facilitate determining its size or use decitxig tables.
10. In Column 3 list P0, the horizontal distance from the to the lower edge of each course on the outer arc (Point C on Fig. 1) P0 * B sin Col 2 angle. Use a calculator and 5 place trigonometric tables.
11. In Column 4 list the circumference (in a horizontal
plane) of the loci of point C about the . This circumference C0 = 2 r P0.
12. In Column 5 list the difference (Co -- Bj) between
the outside circumference ofeach course, Co (Column 4) and the inside circumference (Point B -- Fig. 1)
OtNlC mv MCI
of the inside edge of the same course about the
This
circumference
isB^Co--Bj- (l-lj) Co-
His is derived as follows:
Si " So ' " Ko Therefore Co -- Bj Co -|jCo - Co(l-j^)
^1 -- is a constant.
13. In Column 6 list the total number of brick per
course. This is Co (Column 4) divided by 2H'> the
width of the outside end of each brick regardless of
shape. To speed calculation by avoiding a division
for each course, remember that Co 2 t Po, so
that Total Number of brick per course
2 r Po
)ris a constant, 2J>1328
14. In Column 7 list the number of wedge keys required per course. The difference in circumferences, Co -- Bj (CoL 5) must be satisfied by inserting a number of wedge-cut brick in each course. For example, if a
(2H* -- 2) wedge cut is selected, each wedge key tapers H'< so if Co -- Bj is 10' for a course, 20 wedge keys must be used to turn the circle of that course. Therefore Column 7, Number of
Wedge Keys
15. In Figure 1, note that for any course. Point C swings a larger circle about the l than Point A, the upper outer edge of the same course. Point A is, however, the same as Point C for the next higher course. So, to determine the difference in circumference be tween the loci ofpoints A and C, use Co course No. 1 minus Co course No. 2, Co course No. 2 -- Co course No. 3, etc. This difference is listed for each course in Column 8.
16. In Column 9 list the number of arch key required
per course. The difference in circumferences shown
in Column 8 between Point C and Point A must be
satisfied by inserting a number of arch cut brick in
each course. For example, if a (2H' -- 2') arch cut
is selected, it tapers H'- So, if the difference in
circumferences in Column 8 is 10' for a course, 20
arch keys must be used. Therefore, CoL 9, number
of arch keys
Column 8 Arch-Cut Taper.
It is necessary, sometimes, to use two or more degrees of arch taper on the arch key brick. The key taper remains the same, but on courses approaching
the top of the dome, the arch taper is increased so that the difference in circumference (Column 8) can be satisfied with fewer arch key brick. This is im portant in the upper courses because there are so few brick per course.
17. In Column 10 list the total number of arch key and wedge key for each course. This figure is the sum of Column 7 and Column 9.
18. In Column 11 list the number of key brick required per course. After the arch and wedge requirements have been met, all the remaining brick in a course are keys. Therefore, Column 11 -- Column 6 minus Column 10.
33
Jobns-Manville offers a wide range of refractories for forming monolithic linings. All of these materials are of the highest quality and each performs a
I specific service to industry.
Castable Refractories
-Hydraulic Setting
Refractories
(Castables and Gunning Mixes)
Gunning or "Slap 'Troweling" Mixes................................................
i
I This classification refers to castable refractories
I that, when tempered with water, will develop struc tural strength by reason of a hydraulic set. These refractories are composed principally of alumina or aluminum-silica aggregates, using hydraulic-setting
I cement. Castables are furnished in dry form, are mixed with water on the job. and poured or cast in place
i like portland cement concrete. When casting or pour ing. certain rules must be observed. It is essential to use water suitable for drinking, in the correct ratio,
i with a short mixing time and quick installation. For best results, a vibrator should be used when the castable is placed in the form. Care should be taken to limit the vibration, as excessive agitation will
|----------------------------
force the binder and fines to the surface.
Where the castable is poured in contact with por ous surfaces, such as insulating fire brick or block insulation, it is necessary to coat the surface to pre vent the water escaping from the mix. This can be done by using oil, grease or waxpaper as a coating.
Depending upon atmospheric conditions, installed castables will harden in less than 8 hours, but they should have approximately 24 hours of water curing to assure proper hydration of the binder and to re move heat generated by the chemical reaction. High ambient temperatures lessen curing time, while low temperatures prolong it. Castables should not be installed at freezing temperatures or allowed to freeze until thoroughly cured.
I
I In many industrial furnace operations, it is often de sirable to build or repair sections ofrefractory furnace linings by gunning or "slap-troweling" applications.
wet. With the dry type, the mix is forced through the hose and the right amount of water is added at the nozzle. The wet type combines water and mix in
GUNNING is done with a pneumatic gun that ap-
the hopper to produce a wet mix which is then forced
plies gunning mixes which are hydraulic-setting re
through the hose and ejected from the nozzle.
fractories. These are applied at high velocity and
"SLAP-TROWELING" is used in locations where it is
a pressure to form dense, homogeneous linings.
not suitable or economical to employ gunning pro
|
Gunning mixes are used to advantage in vessels,
cedures. "Slap-troweling" means the cement is
stacks, ash pits, tanks, slab-heating furnaces and
thrown or forced into place with the use of a large-
individual boilers. Densely-compacted linings can size trowel. The cement is mixed with water to a
be gunned quickly and easily with the use of forms. stiff consistency for easy application. The proper
There are two types of guns available: dry and consistency can quickly be found by trial and error.
I
35
J-M Firecrete castable refractories
DESCRIPTION: Johns-Manville produces nine types of castable refractories to meet practically every requirement for temperatures through 3000F. Each of these refractories is economical and effi cient in the service range for which it is recom mended. All harden rapidly and are highly resistant to spalling.
AVAILABLE TYPES:
3X Firecrete--A high alumina refractory for service to 3000F. It is used extensively in ceramic kilns for casting cartops. doors and special shapes of all description. Suitable for casting shapes and linings 2-inch thick or more.
H. T. Firecrete--An economical, high alumina re fractory for service to 2800F. Suitable for casting shapes and linings 2-inch thick or more.
JM-20 Firecrete--A lightweight, economical, alu minum silicate refractory for service to 2000F. This castable combines unusually light weight, high in sulating value and strength. Recommended for cast ing shapes and linings 2-inch thick or more.
2200 CA Insulating Firecrete--A high purity, light weight refractory for service to 2200F in controlled atmosphere applications. This castable supplements CA Insulating Firecrete or JM-20 Firecrete. Recom mended for casting shapes and linings 2 inches thick or more.
Lo-D Firecrete--Designed primarily for use as a back-up insulating refractory in naval boilers. Service to 2500F.
C-31 M Refractory Cement--A chrome base castable refractory for service to 3000F. Used in boilers.
Standard Firecrete--An economical, aluminum sili cate refractory for service to 2500F. It is a generalpurpose castable, developing high strength on air curing. Suitable for casting shapes and linings 1inch thick or more.
L. W. Firecrete--A lightweight, aluminum silicate refractory for service to 2400F. This castable com bines unusually high insulating value with excep tional strength. Recommended for casting shapes and linings 2-inch thick or more.
CA Insulating Firecrete--A high purity, lightweight refractory for service to 2600F. Developed especially for use in controlled atmosphere applications. Rec ommended for casting shapes and linings 2-inch thick or more.
ADVANTAGES:
Hardens Rapidly Firecrete permits casting and use of any desired shape within 24 hours.
Resists Spalling All nine types are highly resistant to spalling.
Negligible Shrinkage Firecrete has no drying shrink age and only negligible fire shrinkage at recom mended temperatures.
Easy and Economical to Use The adaptability of Firecrete makes possible the easy construction of monolithic furnaces, linings and the like which would otherwise require the use of special shapes or in volve costly cutting and fitting of brick.
Specification Data
Physical Properties'
Highest Recommends) Service Temperature
Pyrometric Cone Equivalent
Weight As Placed Oven Dried at 220F After 5-Hr Firing at 1750F
3X
3000F 3313173F)
148 pcf 134 pc) 130 pcf
H.T.
2800F 30 (3002F1
131 pcf 113 pcf 110 pcf
ST0.
2500F 16 (2669FI
130 pcf 116 pcf 110 ocf
l.W.
2400F 1512615F)
109 pcf 80 pcf 75 pcf
CA Insulating
2600F 32 Vi (3135F)
109 pcf 80 pcf 75 pcf
JM-20 C-31 M Refractory
2000F 14 (2552F)
3000F 36 (3290FI
96 pcf 62 pel 58 pcf
193 pcf 183 pcf 177 pcf
2200 CA Insulating Firecrete
2200F 16-17 (2740F)
97 pcf 66 pcf 57 pcf
Crushing Strengths After 5-Hr Firing at:
220F 1200F 1750F 2200F 2400F
3500 psi 2680 psi 2350 psi 2490 psi
2950 psi
700 psi 560 psi 300 psi 580 psi
1500 psi
1310 psi 1190 psi
780 psi 1190 psi 2130 psi
630 psi 595 psi 490 psi 690 psi
1690 psi
580 psi 475 psi 595 psi 650 psi 840 psi
500 psi 490 psi 410 psi 365 psi
IB)
2920 psi 1780 psi 1300 psi 1690 psi 3850 psi
310 psi 320 psi 375 psi 380 psi
IB!
Linear Change Alter 5-Hr Firing at:
1200F
17507 2200F 2400F 2800F
0.2% 0.1% 0.2% 0 7%
09%
0.1% 0.2% 0.1% -0 6%(A) -0.9%!A)
0.0% 0.2% 0.6% -1.6%(A)
(Bi
0.2% 0.3% 0.5% 1.2%
(Bi
0.1% 0.2% 0 3% 0 8%
(Bl
0 4% 0 4%
(B) (B) (Bi
0 2% 0.2% 0.3% 0.5% 1.9%
0.1% 0.1% 0 7%
(B) (B)
'The figure* given n this table are Average values obtained m accordance witn accepted test methods (A Minus sign denotes expansion
(8 Above recommended temperature limit
36
Lo-D
2500F
100 pcf 48 pcf 44 pcf
80 psi 60 psi 80 psi 110 psi 260 psi
0 7% 10% 2.6% 4.2%
(B)
al. aJuF. This gh in-
cast-
. lighttrolled ?ments lecom* thick
as a ervice
castilers.
se of
-tant
inkom-
of rt of
'Id
*
m
| Calculated Chemical Analyela
Material 3X H.T.
LW. JM-20
CAIas. 2200 La-0
Cenpe- Firt- Fire- Standard Fire- Fira- C-31M Fire- CAIts. Fire-
sftaan crate crete Firecrete ertte crate Cement crate Firacrati crate
SiO, 39.9 39.3 40.6 46.2 31.2 4.7 40.1 272 323
Al0j 53.0 503 43.8 36.0 38.4 31.7 513 53.9 413
Fa0j 0.6 4.0 4.7 5.6 4.8 0.8 03 0.4 23
TiO, 13 2.0 22 13 13 0.3 12 02 03
CaO 2.7 4.0 7.8 8.9 21.4 4.7 4.7 152 173
MgO KjO Na,0
0.1 -----
0.1 - 03 15.4 0.1
02 12
I0.4
--
- ( 02 --)
-
--
| 0.1 f 0.4 I
1 01
FeO CrjOj
--
---
- - -- 12.3 - * -- -- 28.5 - -
-
--
Misc.
-- 0.4 0.1 0.9 -- --
-- -- trace
Ig. Loss 0.2 --
0.3 12 0.8 0.7 1.1
13 22
| Thrrmal Conductivity CONDUCTIVITY: ITU IN. PER SO FT KR F PER HR MEAN TEMPERATURE, F
800 1000 1200 1400 1600 1800 2000
3X Firecrete
-- 7.0 72 7.5 7.8 8.4 9.4
H.T. Firecrete
-- 4.45 4.76 5.08 5.41 5.74 --
Standard Firecrete
4.16 4.34 4.59 4.88 5.19 532 --
LW. Firecrete
1.99 2.09 221 2.36 236 2.82 --
CA Insulating Firecrete
-- 237 2.70 2.90 3.12 333 3.65
JM-20 Firecrete
1.43 1.50 137 1.65 1.75 1.87 --
C-31 M Refractory Cement
-- 6.0 6.1 6.3 63 6.7 6.9
2200 CA Insulating Firecrete -- 1.50 137 1.65 1.75 1.87 1.98
Lo-0 Firecrete
- .96 1.16 126 136 1.46 136
| Compliance with Government Spec* lo-D Firecrete complies with MIL-C-19794A
Packaging Information
3X Firecrete............................. H.T. Firecrete........................... Stenderd Firecrete................... L.W. Firecrete........................... CA insulating Firecrete............. JM-20 Firecrete........................ C-31 M Refractory Cement....... Lo-0 Firecrete........................ 2200 CA insulating Firecrete ...
100-lb bags 100-lb bags 50 or 100-lb bags 100-lb bags 100-lb bags
80-lb bags 100-lb bags 50-lb bags 80-lb bags
J-M Firecrete application instructions
Mixing: Firecrete hardens rapidly, therefore water should not be added until the job is ready for applica tion. Only clean, fresh water should be used. Hie amount of water will vary depending upon the size, shape and type of installation. Mix thoroughly after addition of water and adjust to proper percentage. Avoid an excess of water in order to obtain maximum structural strength in the refractory concrete. If cast against a porous material it is necessary to waterproof, or thoroughly wet, the surface to pre vent water being taken from the refractory mixture.
Casting: Forms for casting shapes can be made of either wood or metal. Wooden forms should be coated with shellac to prevent the absorption of water. If necessary, wooden forms can be burned away with out damage to the refractory. If more than one shape is to be cast, heavy metal forms are more satisfactory. They should be smooth and coated with oil or grease to permit the easy removal of shapes. The refractory mixture should be "rodded" with a blunt-end tool,until all comers are filled and air pockets eliminated. The use of vibrating equip ment is recommended.
Curing and Firing: Firecrete air-hardens sufficiently in six hours to permit the removal of forms if neces sary. For linings or large shapes, it is preferable to air cure for 12 hours or longer before firing. In firing, apply heat slowly and without interruption until temperature is brought above service-operating conditions.
Preparation of Door Frames: A door which is less than 4 sq ft in area generally requires no reinforcing to hold the refractory *in place. On larger doors, how ever, it is necessary to provide the refractory with some means of anchorage. Rods with bent ends or bolts with washers and nuts are generally used. Although such anchorage is necessary, best practice suggests that it be kept at a minimum, both in thick ness and number.
All bolts or rods, spaced on about 24' centers, should extend through approximately one-half the thickness of the refractory and, where possible, be placed in a staggered construction. The maximum diameter of the bolts or rods generally used is }-' Anchors should not be placed at the comers of the door. Wrap rods with friction tape to allow for expansion.
Storage: Firecrete should be stored in a cool, dry place as exposure to moisture will cause the mate rial to harden.
ESTIMATED POUNDS OF DRY MATERIAL REQUIRED PER CU FT OF CONSTRUCTION (no allowance mode (or waste)
Type ol Firecrete
lbs/CII ft
3X Firecrete H. T. Firecrete Standard Firecrete L. W Firecrete CA Insulating Firecrete JM-20 Firecrete 2200 CA Insulating Firecrete Lo-D Firecrete C-31 M Refractory Cement
130 110 110 75 75 58 57 44 175
ESTIMATED POUNDS OF WATER REQUIRED PER 100 LBS OF CEMENT
Type of Firecrete
Lbs water/ 100 lbs of Cement
3X Firecrete H T Firecrete Std Firecrete L W. Firecrete CA Insulating Firecrete JM-20 Firecrete Lo-D Firecrete C-31 M Refractory Cement 2200 CA Insulating Firecrete
12 18 17 45 44 66 110
8 64
J-M Blazeerete (for gunning and slap-troweling applications)
DESCRIPTION: Four types of dry monolithic, hy draulic-setting refractories have been developed and produced by Johns-Manville for gunning and slaptroweling applications.
These four refractories are especially adaptable for gun application in building new refractory lin ings and repairing old ones. They adhere readily with a minimum of loss when "shot" in place. Mixed with water at the gun nozzle, they are pneu matically projected with great force, resulting in a dense, homogeneous lining.
Blazeerete is equally effective for heavy patching by troweling, especially where brickwork has eroded deeply. It eliminates the laborious ramming or tamping required with "plastics", and patches need not be prefired.
AVAILABLE TYPES:
3X Blazeerete--High alumina refractory for serv
ice to 3000F. Particularly adaptable for gun appli cations and for heavy patching by slap-troweling.
Standard Blazeerete--Aluminum silicate refractory for service to 2400F.
L. W. Blazeerete--Lightweight aluminum silicate refractory for service to 2000F. Used extensively for stack linings, heaters and other applications where gunning mix with low rebound loss is required.
C-2 Refractory Cement--High strength aluminum silicate refractory for service to 2300F. Used to ad vantage in making a protective abrasion-resistant refractory surface over L. W. Blazeerete.
USES: Recommended for lining or patching forge furnaces, ashpits, cyclones, heaters, boilers, oil refin ing equipment, furnace bottoms, ladles and similar applications. L. W. Blazeerete is extensively used on tanks, structural steel and skirts for fire protection purposes.
Spmclflcatlon Data Physical Propertlas*
Highest Recommended Service Temperature
Pyrometrie Cone Equivalent Weight Slap Troweled:
As Placed Oven Dried at 220F After 5-Hr Firing at 1750F
Weight Gunned: As Placed Oven Oried at 220F After 5-Hr Firing at 1750F
Crushing Strengths After 5 Hours Firing uL 220F 1200F 1750F
2200F 2400F
Linear Shrinkage After 5 Hours Firing at: 1200F 1750F 2200F 2400F
3X
3000F
33 (3173F)
148 pcf 133 pef 130 pcf
153 pef 142 pcf 140 pcf
570 psi 700 psi 790 psi 1040 psi 2390 psi
0.0% 0.0% 0.2% 0.2%
STD.
2400F
16 (2669F)
132 pcf 116 pcf 110 pcf
134 pcf 124 pcf 118 pcf
1350 psi 1070 psi 1130 psi 1480 psi 2870 psi
0.1% 0.4% 0.6% 0.4%
*TDc ficures liven in this table are averafe values obtained in accordance with accepted test methods. (A) Above recommended temperature limit
40
LW.
2000F
14 (2552F1
104 pcf 69 pcf 65 pcf
117 pcf 76 pcf 73 pcf
500 psi 500 psi 600 psi
(A) (A)
0.3% 0.6%
(A) (A)
C-2 Cement
2300F
15 (2608F1
140 pcf 126 pcf 120 pcf
142 pcf 134 pcf 128 pcf
6200 psi 4700 psi 2600 psi 2700 psi
(A)
0.2% 0.2% 0.1%
(A)
| Calculatad Chamlcal Analysis
Matarial
ax
Standard
UN.
Caaptsttiaa Blaztcrtts Biazacrate Blaacreta
U Cement
SiOj Al>0j Fe,0, HO] CaO MgO K.0 Na,0 Misc. Ig. Loss
38D 535
1.7 2.6 2D -
trace trace
15
415 43.1 42 22 6.7
0.1
) V 05 )
0.1
15
33.6 38D 4.1
1.3 19.9 0.4 / } 05 (
2D
40D 33.4
75 13.6 1.1 05 0.1 05
Thermal Conductivity CONDUCTIVITY: ITU IN. KR $Q FT PER F PER HR
Meaa Tame*retire
F
3X Biazacrate
Standard Btazacrete
uv.
Biazacrate
C-2 letractary
Cameat
800 1000 1200 1400 1600 1800 2000
-- 3.89 156 -
4.10 3.95 1.43 3.40
4.30 4.05 1.59 350
4.68 454 1.76 350
5.40 457 1.92 4.30
655 5.09 2.08 5.10
7.68 -
- 5.90
Packaging Information
3X Blazecrete .............................. Standard Blazecretc ..................... UN. Blazecrete ............................ C-2 Refractory Cement .................
100-lb bags 100-lb bags .80-lb bags 100-lb bags
GUNNING
J-M Blazecrete application instructions
monolithic, ?n developed inning and .
cially adapt refractory adhere re.not" in p
. they are p e, resulting
heavy pate work has er us rammir nd patches
ictory for
3X 3000f 33 (3173 148 pcf 133 pcf 130 pcf
153 pcf 142 pcf 140 pcf
570 psi 700 psi 790 psi 1040 psi 2390 psi
0.0% 0.0% 0.2% 0.2%
d m accoroanci
Preparation of Surface All surfaces should be clean and free of loose scale or other foreign material. When Blazecrete is applied to worn brickwork or other refractories, the surface should be chipped to expose raw solid material Metal should be cleaned by wire brushing, steam, or sandblasting to provide a satisfactory surface.
Reinforcement As a general ruie, reinforcement is not required when Blazecrete is gunned on a sloping or flat surface because gravity will hold it in place. However, on vertical walls or overhead areas, ex cept for patching, reinforcement should be used to hold the refractory in place.
Where continuous reinforcing is unnecessary, rods with bent ends or bolts with washers and nuts should be used. All bolts or rods, spaced on about 24' cen ters, should extend through approximately one-half the thickness of the refractory and where possible be placed in a staggered arrangement. Use bolts or rods with a maximum diameter of V'- Friction tape wrapped around the bolts or rods will permit expan sion of the metal under heat.
For continuous reinforcement, welded wire fabric or hexagonal steel grating is recommended. A wire fabric should be spaced midway in the refractory and held in place with suitable studs, lag bolts, or other means. When more than one type material is to be applied, include a reinforcing mesh in each layer. For thin linings, hexagonal steel grating or 1' thick with openings approximately 1 % ' x 1 x 14 gauge should be tack welded to the equipment and the refractory applied flush to the surface of the hexagonal mesh.
Gunning Follow the standard methods of gunning as recommended by gun manufacturers. It is helpful to pre-moisten Blazecrete before placing it in the gun hopper. This can be done by first putting the Blaze crete in a concrete mixer and adding a small amount of water. After thorough mixing, the Blazecrete should be just slightly damp, but not enough to ball up. Pre-moistened Blazecrete tends to take on addi tional water at the gun nozzle more readily and the amount of dust and rebound is kept to a minimum. Some guns premix water with the cement before reaching the gun nozzle.
Do not apply refractory through grating or mesh with openings of less than 4' if the shell of the vessel or the insulating surface is more than l" from the underside of the mesh or grating. A given area should be finished if there is to be a lapse of time before the entire job is completed. When work is resumed, the
42
m
contact surface of the material which has already ben applied should be roughened, cleaned and wet.
When Blazecrete is used in double layers, the first layer should still be wet when applying the second layer. Do not use rebound material.
Troweling Mix Blazecrete thoroughly with clean, fresh water until a stiff consistency is obtained so that it can be readily placed by slap-troweling.
Curing and Firing It is preferable to air cure Blaze crete for 12 hours or longer before firing. Heat slowly and without interruption, bringing temperature above the service operating conditions.
Product type
Estimated Pounds of
Refractory Required
for 1 Cubic Foot Estimated Pounds of Water
(No allowance
Required for 100 lbs.
made for waste!
of Cement
3X Blazecrete
130 (slap-troweling) 140 (gunning)
Standard Blazecrete
110 (slap-troweling! 118 (gunning)
L.W Blazecrete
65 (slap-troweling) 73 (gunning)
C2 Refractory Cement 120 (slap-troweling) 140 (gunning)
14 18 53 15
J-M Refractory Cements (Mortars)
The purpose of J-M Refractory Cement in laying fire brick is to bond together many relatively small units into a stable, strong and gas-tight structure. The nature of the cement or mortar used, and the manner applied largely determine the strength and efficiency of the refractory masonry.
Use of the proper mortar for the particular condi tion involved assures correct bonding, protection of joints against slag, resistance against passage of gases, and reduction in spalling difficulties.
To fulfill the many different service requirements, J-M provides several different types of mortars or cements which are classified under "Ready-Mixed, Air-Setting" and "Dry, Heat-Setting."
Ready-Mixed, Air-Setting Cements (Mortars)
BLAKITE REFRACTORY CEMENT
A highly refractory, ready-mixed, air-setting cement which possesses high water-retention properties, making it adaptable for laying insulating fire brick. Furnished in a consistency suitable for shallow patching, Blakite can also be used for laying fireclay, super duty and high alumina refractory brick. It is dark gray in color. Temperature to 3200F.
SUPER BLAKITE
Used for coating over vertical industrial boiler tubes, shallow patching; and laying brick. Temperature to 3000F.
HELLITE REFRACTORY CEMENT
A general purpose, air-setting cement which is finely ground, ready-mixed, plastic and pink in color. Used for setting hard brick with Yroweled or dipped joints, for wash-coating and especially for shallow patching, either hot or cold surfaces. Can be used up to 3000F.
NO. 20 REFRACTORY CEMENT
An air-setting cement, gray in color, for use where an extra hard air set is desired. Used up to 2700F for setting hard brick with a rubbed joint, and for wash coating. When desired to use old fire brick as a patching material or monolithic fill, No. 20 is thinned with water and the crushed brick added. Bonding brick: All types of air-setting cements re tain easy workability even though kept in storage
for long periods. These mortars can be thinned with water to suit the porosity of the brick to be bonded. Full directions are furnished with each cement shipment.
To obtain maximum workability and best results, the mortars should be thoroughly mixed before us ing. If a thinner consistency is desired, small quanti ties ofwater are slowly added -re-mixing thoroughly after each addition until desired consistency is ob tained. An excess of water should be avoided.
Wash-coating brick: When Hellite, No. 20 and No. 32 (see belowi are used for wash-coating, the setting should be thoroughly cleaned and the cement mixed with sufficient water to bring it to a thin grout con sistency. The mixture is applied to the face of the brickwork with a stiff brush or broom, working it well into the cracks and pores in the brick. It is im portant to apply the mixture thinly in order to prevent flaking.
When old settings have to be'scarified in cleaning, it is necessary to thoroughly remove all dust particles before wash-coating. This can be accomplished by carefully blowing out dust with an air gun or by hos ing out the crevices and washing the walls with water.
Dry, Heat-Setting Cements
(Mortars)
NO. 31 & NO. 32 REFRACTORY CEMENT
The above mortars are heat-setting used for l&ying hard brick. No. 31 is recommended for thick joints and is a coarse material. No. 32 is similar to No. 31 Cement, but has a finer grind. It is recommended for dipped joints. Recommended up to 3100F.
When preparing No. 31 and No. 32 cements, water is mixed with the cement to provide the proper con sistency. Clean, fresh water is required; the quantity depending upon the porosity of the brick which can best be found by trial. The mortar should be thor oughly mixed and free from lumps. Maximum work ability isobtained by allowing themortar to "temper" after mixture with water. Long periods of tempering will not cause deterioration.
Dry, Air-Setting Cements
(Mortars)
NO. 26 REFRACTORY CEMENT
A coarse, dry cement which takes a medium air set. Used for setting fire brick with a medium bond joint. In special cases also recommended for hot or cold shallow patching, cement gun work and rammed linings. For temperatures to 2900F.
44
thinned with o be bonded, each cement
I best results, ed before us-mall quantig thoroughly tency is oboided.
0 and No. 32 the setting ment mixed ! grout conface of the working it k. It is imn order to
in cleaning, ist particles lplished by i or by hoswith water.
for laying hick joints to No. 31 'mmended 100F. nts. water roper con? quantity which can i be thorum work"temper" empering
n air set. >nd joint, t or cold rammed
3U .
k-- . >fc
Caleulatmd Chemical Analyala Wat Camanta*
Miteriil #20 Composition Coment Hellite
Soper Finite Blakite Blakite
SiO, 90.8 49.6 85.4 48.8 48.1
ai,o3 5.1 37.8
6.4 435 43.1
Fe,03
-
2.5 0.1
15
1.6
Ti03 - 25 - 1.5 1.4
CaO - 0.6 - 0.3 0.3
MgO - 0.1 - - -
K,0 - 14 - 0.8 0.9
Na,0 3.3 1.8 6.1 2.4 2.7
Misc.
0.8 0.4
-
---
Ig. Loss
"
3.6 2.0 1.8 1.7
Arwlyjis it on a dry bis.
Packaging Information
Blakite and No. 20 Refractory Cement--200, 100, 25, 15, 10 and 5-lb containers
Super Blakite and Hellite-200, 100 and 50-lb con tainers. No- 26, 31 and 32-100-lb bags.
45
ts (Mortars)
twelght Refractory gatas and Fills
it in laving tively small t structure, ed, and trength
:ular cc rotectic passag ies. iuirem< mortal tdv-Mi
nts
ing cei propel fire t jr sh; ng fire brick. F.
tit aggregates and fills serve for : refractory concretes and as granular
ecking irregular or otherwise inaccessible spaces i provide insulation on high-temperature equipment.
These lightweight aggregates and fills include the following products: JM-Zelie, JM-2400, Sil-O-Cel C-3,
Sil-O-Cel Insulating Powderand Sfl-O-Cel Coarse Grade.
Sil-O-Cel Insulating Powder and Coarse Grade are used as fills only.
When used as fills, the products are worked into place
in their original dry form. When used as an insulating
refractory concrete for various operating conditions, the
aggregates (JM-Zelie and 2400) are TMhwd with calcium
aluminate cement. Sil-O-Cel C-3 can be used when mixed
with either
aluminate cement or
ce
ment. The insulating refractory concrete is used for con
structing foundations and bases of heated equipment,
furnace doors, and many special shapes such as baffles
dampers.
All of these products are invaluable for the conserva tion of heat where other forms of insulation cannot be economically installed because of surface irregularities or lack of space. They are also excellent for the many in dustrial requirements which demand satisfactory insu lating refractory cements.
Specification Data
Approx, density ts whick Nine Coaposltise Teaperitan fills are esrwally Pockagiag
IHsItP packed, lbs perce ft
liler t >erau
rh is olor. ped j . pate i to 3
JM-2400 LW. Aggregate al. silicate
JM-Zelie L.W. Aggregate al. silicate
Sil-O-Cel C-3
calcined, coarsegraded diatomaceous silica
Sil-0-Cel
Insulating Powder
finely ground diatomaceous silica
Sil-O-Cel Coarse Grade
similar to Sil-0-Cel Insulating Powder, but coarsely ground
2400 2400 2000
1600
1600
50 31 31
17
22
| J-M Inaulatlng Refractory Concretee
80-lb bags 50-lb bags 50-lb bags
50-lb bags
50-lb bags
use ' 270( d for hricli 1 is th
The lightweight aggregates (JM-Zelie and 2400) and Sil-O-Cel C-3, in the form of insulating refractory con cretes, can be formed into any shape desired. The tables following give typical mixtures based upon average values obtained from uniform, well-tamped or cast insu lating concrete. In every case, excessive water is detri mental to the strength of the insulating concrete and should be avoided.
eniei in s
46
Sil-O-Cel C-3 Insulating Concrete
I Tamping Consistency* SJI-O-Cel C-3 nixed 4 to 1 by Volume
with with Calciun
I Portland Cental Aluninate Cement
Loose Density. Sil-O-Cel C-3, lb per cu ft................
23 to 28
23 to 28
Approx. Ratio by Weight (Sil-O-Cel C-3 to cement)..
50-50
50-50
Mixing Water by Weight, percent............................. Yield, Dry Mix per cu ft, lb.......................................
86 50.5
80 54
Maximum Service Temperature, F............................
1800
1800
'Avoid excessive water.
JM-Zelie L W. Concrete
JM-Zelie miied 3 to 1 by Volume with Culcium Aluminate Cement
Tanping Consistency* Casting Consistency*
Loose Density, JM-Zelie. lb per cu ft............ Approx. Ratio by Weight (JM-Zelie to cement). Mixing Water by Weight, percent.................. Yield, Dry Mix per cu ft, lb............................ Maximum Service Temperature, F................
41 5743
65 62 2000
'Avoid excessive water.
41 5743 68.5
58 2000
Sil-O-Cel C-3 Insulating Concrete: First thoroughly mix Sil-O-Cel C-3 with water (16 gallons of water per 100 lb of Sil-O-Cel C-3), then add Portland or calcium alumi nate cement and thoroughly mix with the wetted Sil-OCel C-3 to the desired working consistency.
The homogeneous mixture is then placed in the re quired form, reinforced if necessary, and tamped with a heavy metal tamper until the required thickness is ob tained. Sufficient force must be used in tamping to provide a uniform, coherent mass, free from voids. The form is then covered with a damp cloth and kept wet for not less than 48 hours, then dried slowly in a warm, wellventilated place, and finally subjected to a slow initial heat until all the water has been eliminated.
When a mechanical mixer is used, part of the water should be poured into the mixer before the dry Sil-O-Cel C-3 is added, and the inside of the drum thoroughly flushed. (This prevents the Sil-O-Cel C-3 from balhng-up in lumps and sticking to the walls.)
The dry Sil-O-Cel C-3 and remaining water should then be put in the mixer and thoroughly mixed. From this point, the procedure is the same as described above.
With a mechanical mixer, each batch of Sil-O-Cel C-3 Insulating Concrete should be completed in from four to five minutes.
JM-Zelie L. W. Concrete: The aggregate and calciun uminate cement are first thoroughly mixed. Then wate:
is added slowly to obtain the desired tamping or castin| consistency. For highertemperature conditions, JM-24CX
, ' ji_j8grefate can ** uaet^- This aggregate is general!' handled in the same manner as JM-Zelie Aggregate.
47
I J-M Cera felt refractory fiber felt
DESCRIPTION: J-M Cerafelt is a lightweight, re fractory-fiber insulation notable for its excellent thermal and chemical stability. Made predominantly of alumina and silica, it combines lightness, heat resistance, low conductivity and high sound-absorp tion qualities.
AVAILABLE FORMS: Furnished in densities ranging from 3 to 24 lbs. per cu. ft. Also available in loose form (J-M CERAFIBER) in 25-lb. bags.
USES: Recommended for a great variety of high temperature industrial applications such as insula tion protection in repairing open hearth roofs; on cover-type annealers to fill openings for electrical access; expansion joints in kilns, furnaces and boiler walls.
ADVANTAGES
High Heat Resistance
Will withstand continuous exposure to a full 2000F.
Low Thermal Conductivity
Unusually low conductivity at high temperatures due to opacity of basic fibers to infra-red radiation.
Light Weight
Weighs as little as 1/40 equal volume of hard fire brick.
Chemically Stable
Non-alkaline and chemically stable. Contains no corrosionpromoting agents.
Thermal Conductivity
CONDUCTIVITY: BTU IN. PER SO FT PER F PER HR
Density
MEAN TEMPERATURE F
lbs ner ce ft 300 400 500 600 700 800 900
1000
3 .40 .48 57 .68 50 53 1.08 155 4 .38 .44 52 .61 .71 52 .94 157 6 .36 .41 .47 .54 .62 .70 .79 59 8 .34 .39 .45 51 57 .64 .72 .81 10 .33 .38 .43 .49 .55 .61 .68 .76 12 .33 57 .42 .47 53 59 .65 .72 14 .33 .37 .41 .46 51 57 .63 .69 18 .32 .36 .40 .45 50 55 .60 .65
24 .31 .35 59 .44 .48 *1 58 .62
Standard Danaltlea A Thicknesses
Density*
Available Thicknesses,* Inches
Type lbs per cn ft K X. K K K a 1 IK
2
CRF-300 CRF-400
3 4
0000XX 00000X
CRF-600 CRF-800 CRF-1000 CRF-1200 CRF-1400
6 8 10 12 14
0000XX 000000X XXXX XXX XXXXXXX X X XX X X
CRF-1800
18
XXXXX
CRF-2400
24
XXXXX
'Other thicknesses end densities available on request 0 denotes aveilability of 4' and S' sheets and 26' rolls x denotes availability of 4' and S' sheets only Standard Nidth is 42 inches
1
Ity
H. PER SQ FT PER F PER HR *AN TEMPERATURE, F )0 j 600 700 800 900
1000
>7 .68 .80 .93 1.08 1-25 2 .61 .71 .82 .94 1.07 7 .54 .62 .70 .79 .89 5 il .57 .64 .72 .81 3 .49 .55 .61 .68 .76 2 .47 .53 .59 .65 .72 1 I .46 .51 .57 .63 .69 D .45 .50 .55 .60 .65 j: .44 .48 .53 .58 .62
& Thicknesses
Available Thicknesses,
1*>,; y.
a /. 1 IK 2
0000XX
00 0 0 0X
00 00X X
0000X
XX X X X
XX XXX
XXXX
XXX
x 1X X
ole on request ;ts and 26' rolls 'ts only
J
4
Glossary of terms relating to refractories
Abrasion of Refractories.--Wearing away of refractory surfaces by the scouring action of moving solids.
Air-Sotting Refractory Mortar.--A composition of finely ground materials, marketed in either a wet or dry condi tion, which may require tempering with water to attain the desired consistency and which is suitable for laying refractory brick and hrmrimg thawn strongly upon drying and upon subsequent heating at furnace temperatures.
Bloating of Refractories__ Substantial swellingproduced by a beat treatment that onuses the formation of a vesicular structure.
Bond Fire Clay. --See Fire Clay, Plastic or Bond.
Bum (n).--The heat treatment to which refractory materials are subjected in the firing process.
Burning (Firing) of Refractories.--The final heat treat ment in a kiln to which refractory brick and shapes are subjected in the process of manufacture for the purpose of developing bond and other necessary physical and chemical properties.
Calcine or Calcines (n).--Refractory material, often fireclay, that has been heated to eliminate volatile constituents and to produce desired physical changes.
Calcining of Refractory Materials.--Hie heat treatment to which raw refractory matirinU ere subjected, prepar atory to further processing or use, far the purpose of eliminating volatile chemically combined constituents and producing volume changes.
Corrosion of Refractories.--Destruction of refractory surfaces by the chemical action of external agencies.
Diaspora Clay.--A rock consisting essentially ofdiaspora bonded by fire clay.
Dolomite, Calcined Refractory.--Raw refractory dolo mite that has been heated to a temperature sufficiently high and for a long enough time to decompose the carbonate structure and remove volatile constituents.
Dolomite, Dead-Burned Refractory.--Raw refractory dolomite that has been heated with or without additives to a temperature sufficiently high and for a long enough time to decompose the carbonate structure so as to form calcium oxide and periclase in a matrix that provides resistance to subsequent hydration and recombination with carbon dioxide.
Double-Screened Ground Refractory Material.-- A refractory material that contains its original gradation of particle sizes resulting from crushing, grinding, or both, and from which particles coarser and finer than two specified sizes have been removed by screening.
Erosion of Refractories.--Wearing away of refractory surfaces by the washing action of moving liquids.
FACTORY FIBEF
* is a lightweigh .able for its exc
Made predomir. mbines lightness, md high sound-al
id in densities ra Also available in i 25-lb. bags. great variety of :ations such as ii open hearth roo: openings for elec ns, furnaces and
re to a full 2000F.
lph temperatures i radiation.
ime of hard fire bri
e. Contains no cor
Erosion of Rofractorios.--Wearing away of refractory surfaces by the washing action of moving liquids.
Firebrick. --A broad term covering any type ofrefractory brick used more narrowly to mean fireclay brick.
Firebrick, Insulating.--A refractory brick characterized by low thermal conductivity and low heat capacity.
Fire Clay. --An earthy or stony mineral aggregate which has as the essential constituent hydrous silicates of aluminum with or without free silica, plastic when sufficiently pulverized and wetted, rigid when subse quently dried, and of suitable refractoriness for use in commercial refractory products.
Fire Clay, Nodular.--A rock containing aluminous or ferruginous nodules, or both, bonded by fire clay.
NOTE. --In some districts such days are called "hurley" or "hurley flint"day.
Fire Clay, Plastic or Bond.--A fire clay of sufficient nat ural plasticity to bond nonplastic materials.
Fireclay Plastic Refractory.--A fireclay material tem pered with water and suitable for ramming into place to form a monolithic furnace lining that will attain satis factory physical properties when subjected to the heat of furnace operation.
Flint Fire Clay.--A hard or flint-like fire clay occurring as an unstratified massive rock, practically devoid of natural plasticity and showing a conchoidal fracture.
Grog. --A granular material produced from calcined or burned refractories, usually alumina-silica.
Grog Fireclay Mortar. -- Raw fire clay mixed with calcined fire clay, or with broken fireclay brick, or both, all ground to suitable fineness.
Ground Fire Clay.--Fire clay or a mixture of fire clays that have been subjected to no treatment other than grinding or weathering, or both.
Ground Fireclay Mortar.--A refractory mortar consisting of finely ground raw fireclay.
Molten Cast Refractory.--A solidified material made by melting refractory ingredients and pouring into molds.
Mortar, Heat Setting.--A refractory mortar of finely ground materials whose potential strength is dependent on use at furnace or process temperatures.
Mortar, Refractory.--A finely ground preparation which becomes plastic and. trowelable when tempered with water and is suitable for laying and bonding refractory brick.
50
I
Mullite Refractories. --Refractory product? consisting Refractories, Neutral.--Refractories that are resistant
predominately of mullite 3Al_>Oi -2SiOj crystals formed
to chemical attack by both acid and basic slags, refrac
either In i%nversion of one or more of the siliimanite croup ol minerals or by synthesis from appropriate
tories. or fluxes at high temperatures.
Refractoriness.--In refractories, the pro|>erty of being
m. pen. 11-employing either melting or sintering processes.
resistant to softening or deformation.
Permanent Linear Change.--The per cent dimensional
Refractory iadji.-- Resistant to high temperature.
i liance m length i based on original length i of a refractory |n`<mien free of externally applied stresses, after being
Reheat Behavior.--The changes in length or volume
taking place in a fired refractory when subjected to a
>uhieeu*d to a prescribed heat treatment.
reheat test.
Plastic Refractory. -- A refractory material, tempered with
Reheat Test--The prescribed heat treatment of a fired
water, that can be extruded and that has suitable work
refractory free of externally applied stresses to deter
ability to be pounded into place to form a monolithic
mine its linear or volume stability by measurements
structure.
before and after the heating.
Porosity.--The percentage of the total volume of a
Shrinkage.--The decrease in dimension of a refractory
material occupied by both open and closed pores.
material during manufacture or service.
Pyrometric Cone Equivalent PCEi.--The number of Silica Fire Clay.--A refractory mortar consisting of a
that Standard Pyrometric Cone whose tip would touch
finely ground mixture of quartzite, silica brick, and tire
the supporting plaque simultaneously with a cone of the
clay of various proportions.
refractory material being investigated when tested in accordance with the Method of Test for Pyrometric Cone Equivalent i PCEi of Refractory Materials tASTM
Designation: C 24).
Quartzite (Canister).--For refractories, a rock consisting
predominantly of the mineral quartz suitable for the manufacture of silica brick and characterized by a high SiU.- content and a low percentage of impurities.
NOTE.--Sometimes called silica cement by the trade.
Silicon Carbide Refractories.--Refractory productscon-
sisting predominantly of silicon carbide.
Slagging of Refractories.--Destructive chemical rear
tion between refractories and external agencies at high temperatures resulting in the formation of a liquid.
Spalling of Refractories.--The cracking or rupturing of
a refractory unit, which usually results in the detach
NOTE.--Confusion sometimes results from the use of
ment of a portion of the unit.
fl IIIe term ganister because it is also applied in some parts of Spalling of Refractories, Mechanical.--The spalling of a
the L'nited States to crushed firebrick or to a mixture of refractory unit caused by stresses resulting from impact
crushed firebrick or silica rock with clay for use in tamped or pressure.
hnings.
Spalling of Refractories, Structural. -- The spalling of a
I Ramming Mix.--A refractory material, usually tempered
refractory unit caused by stresses resulting from differ ential changes in the structure of the unit.
with water, that cannot be extruded but that has suit
Spalling of Refractories, Thermal.--The spalling of a re
i able pro|>erties to permit ramming into place to form a monolithic structure. Refractories n ,.--Materials, usually lion-metallic, used
fractory unit caused by stresses resulting from nonuni form changes of the unit produced by a difference in temperature.
to w ithstand high temperature.
Stopper Head.--A rounded refractory shape, usually
i Refractories, Acid.--Refractories containing a substan tial amount of silica that may react chemically with
made from clay and graphite, providing a valve head seating into a nozzle brick, this assembly forming a
basic refractories, basic slags, or basic fluxes at high
metal flow control for bottom-pouring ladles.
tem|)eratures.
Thermal Expansion.--The reversible change in size of
i Refractories, Basic.--Refractories whose major constitu ent is lime, magnesia, or both, and which may react chemically with acid refractories, acid slags, or acid fluxes at high tem|>eratures.
materials due to termjierature changes.
Unbumed Brick. --Brick manufactured by processes
that do not involve firing of the finished product.
Zircon Refractory-- Refractory products consisting sub
I SOTE.--Commercial use of this term also includes re stantially or entirely of zirconium orthosilicate ZrSi041.
fractories made o/ chrome ore or combinations o; chrome Zirconium Oxide Refractory. --Refractory products con
ore and dead-burned magnesite.
*
sisting substantially ol zirconium dioxide.
] 51
COLOR-TEMPERATURE CONVERSION
The cover of this catalog iiius trates graphically the appro*, mate relationship between cO'Or and temperature in the com mon furnace operating ranges