Document O17GEarDa40DRKQEXadzk4p5p
TECHNICAL REPORT DATA
frttttt reed Imiwetiont on 0\t rrvtnt defter competing/
I.MPO^l NO.
12.
tPA 440/9-76-Q20_____________ 1
,
J. RECIPIENT'S ACCESSION NO, _______________
4.TiTLiA\oL>TiTL pcBs Water Ellmlnatlon/Reductlon
S. REPORT DATE
technology and Associated Costs, Manufacturers of Electrical Capacitors and Transformers (Addendum to
Julv 2. 1976 1. PERFORMING ORGANIZATION COOt
'
Final Reoort. Task lit . AMTHOmS)
S. PERFORMING ORGANIZATION REPORT NO.
Dr. Robert Durfee and Staff
'
1. PERPORMINO ORGANIZATION NAME AND AOORKES
Versar, Inc. 6621 Electronic Drive Springfield, Virginia
22151
.
IS. SPONSORING AGENCY NAME ANO ADORESS
Office of Water Planning and Standards
U.S. Environmental Protection Agency
401 M Street, S.W.
Washlnoton. D.C. 20460
.
IS. SUPPLEMENTARY NOTES
~ .
id. PROGRAM ELEMENT NO.
Task II 11. CONTRACT/GRANT NO.
-------
68-01-3259
IS. TYPE OP REPORT ANO PERIOD OOVEREO
14. SPONSORING AGENCY CODE
.
None is. Amtaact
* ."
This addendum report summarizes the quantities and sources of wastewaters In the
manufacture of electrical transformers and capacitors; describes the alternate
available technologies for reducing or eliminating the discharges on a source-
by-source basis; and tabulates the estimated costs for achieving speh reduction
or elimination.
.
'
'*
`
HONS 047411
If, 1. DESCRIPTORS
Wastewater Waste Treatment
Cost Analysis Cost Comparison
Manufacturers
IS. DlSTRIMUt C'. STATEMENT
RELEASE UNLIMITED
IPA W--m #* <f.P|
KEY WORDS ANO DOCUMENT ANALYSIS S.IOINTlPlSRS/OPtN ENDED TERMS
e. COSATI Fkld/Oroap
, Toxic Pollutant Effluent Standards
Federal Water Pollution Control Act
_ IS. SECURITY CLASS Unclassified
0 SECURITY CLASS
Unclassified
SI.NO.o/^Adll 41
92. PRICE
;
1.0 lOTROCUCnCN
tee Task II Final Report, "Assessment of Wastewater Management, Treatment technology, and Associated Cbsts for Abatement of PCBs Concentrations in In dustrial Effluents," ^ discussed the diverse sources of PCB-oontaminated wastewaters within the askarel capacitor and transformer manufacturing indus try. these contaminated waters, in addition to contact process waters, also included "non-contact" cooling waters, stormwater runoff from the manufacturing plants, and sanitary wastewaters.
tee general potential for reduction of water use in this industry is fawrable, since water has to be carefully excluded from the internals of both transformers and capacitors in order for the units to meet product and performance specifications. Newer plants in these categories, particularly those of smaller size, use nuch less water per unit of PCB usage than the older plants. Howver, the existing plants in the industry would require a combina tion of process and plant modifications and wastewater treatment and recycle to achieve a goal of no discharge of FC8-contaninated waters. This addendum to the Task II report summarizes the quantities and sources of the wastewaters; describes the alternate available technologies for reducing or eliminating the discharges on a source-by-souroe basis*; and tabulates the estimated costs for achieving such reduction or elimination.
Section 2.0 of this addendum addresses the point sources from the capacitor and transformer manufacturing industry with the absolute goal (with a single exception from one plant) of no point-source discharges of any waters. Exten sive applications of process changes (from wet to dry unit processes or unit operations), of water segregation practices, of water treatment and recycle practices, and of water-quantity reduction practices were investigated, tee residual contaminated wastewaters not eliminated by these practices were then hypothesized to be "incinerated," e.q., heated to a sufficiently high
u
MQNS Q4 7^ii
tanporatura for a sufficiently long tine to ensure destruction of PCB cor-
tanlnants.
.
Section 3.0 presents the technologies and costs for eliminating PCB con tamination of rainwater runoff from manufacturing plants in this industry.
Section 4.0 presents the technical basis and estimated costs for three alternative approaches to PCBs reduction in the direct discharges from this industry to waterways. The technology and costs presented are based on those of Reference 1 and Sections 2.0 and 3.0 of this Addendum. The approaches ware selected to offer a range of PCBs control at various levels of costs.
the estimated costs contained herein are as accurate as was possible within the eoopa of work. Based on previous experience in this area, we feel that the least reliable costs tabulated are those for waste stream segre-gatlxxv.--Costs for segregation are highly variable from plant to plant, and-- accurate estimation iFonly~possible as a result of detailed study of plant layout, piping, etc., which was beyond the scope of this study.
MQNS 047413
) -2-
2.0 mxNQUxar and cost no achieve zero discharge frcm point sources St THE ASKAREL CAPACITOR Afc TRANSFORMER MANUFACTURING INDUSTRY
2.1' Present Sources of Point-Source Discharges
The' wastewater discharges frcm the askarel capacitor and transformer
manufacturing industry, which have been shown to contain measurable quantities
of FCBs,
are from the following sources:
2.1.1 Non-contact cooling water. The major uses include cooling of impregnation tanks, of vacuum pimps, and of vapor degreasing units. Minor uses include cool ing of ccnpressors and welders.
2.1.2 tbter-sealed vacuum pimps and steam-jet ejectors, used in seme of the plants to evacuate impregnation tanks
______ ___or individual product, assemblies for moisture removal prior to filling with askarel.
__ .
2.1.3 Detergent washing of components and of asseiblies. De tergent washing occurs in two general areas. One area is cleaning and degreasing components such as cans, tops, terminals, etc., prior to assembly. These oenpenents may be produced at the plant from metal stodc or brought in already fabricated. The second area of use is in re moval of excess oil from the filled units after the seal ing operation.
2.1.4 Rrrfler blowdowns, air conditioning condensates, and contact cooling water (from welding and soldering opera tions) .
2.1.5 Contaminated process wastewaters, including vacuum pug? -- condensates, laboratory wastewaters, and wastewaters from
surface treatment operations such as plating, phosphatizing, painting, fluoride treatment, and caustic baths. Surface
)
MONS 047*14 3-
treatments prior to painting typically involve phoephatizing of ateel and fluoride treatment of aluminum, both of vfaich involve the use of water baths. Plants which fabricate capacitor ccnponents on site (several of the larger plants do so) perform tin plating of the covers and studs as a corrosion protection at joints. Hater usage includes the plating bath and rinse water. The water usage is small.
____ ----
2.1.6 Sanitary and personal hygiene wastewaters. Sanitary and personal hygiene water usage in this industry, al though small in comparison to cooling water usage, typi-
- cally becomes highly-contaminated with PCBs. Water uses in this category include handwashing, showers, safety
----------- purposes including eye washing, drinking fountains, laundry, and toilet flush.
. -
2.1.7 The wet scrubber for the waste incinerator flue gas at one plant (Plant 103). This plant operates its own in cinerator to destroy liquid PCB wastes. The scrubber water used to cleanse the stack gases must be regarded as process water, anc(, based on the PCBs concentration in the scrubber effluent of Monsanto's incinerator(150 ppb), this water is very likely to be contaminated with PCBs.
The quantities and disposition of these existing point-source dis
charges have been tabulated in the Task II report for the eight plants sur veyed. (lb)
2.2 Technologies for Eliminating Point-Source Discharges
The technologies for eliminating the discharges are:
2.2.1 Segregation of non-contact cooling water supply and dis charge lines from all other plant waters (e.g., process
HONS 047415
waters, sanitary waters, etc.}; replacement of open sewers and channels with closed discharge piping to a ocmnan location; cooling of these discharge waters in a closed non-evaporative heat exchanger (e.g., a tcwer with forced circulation of water through finned tubes, cooled by a forced-air draft.); and recycle of the cooled waters. Blrxl from this closed circulation sysLi.sn would be added to toiler bio.'towns for trenbamt and return.
. ____
One of the eight plants surveyid in the Task IT effort.
(Plant. 101) already lias segregated non-contact moling
water; however, this plntl lias an cvnjxirntivo-tyjo al-
ing tower. Closed lieat exdianoers_aro, however, the
reoamended technology to prevent losses of PCBs to Ito
ataps|ihere.___
.
2.2.2 Replacement of water-scaled vacuim pimps and stcvun-jct systems with mechanical, oil-scaled vacuus pimps- Non contact cooling water for these pimps would to ;iddod to the circuit discussed alovc. condensate, after separation from the oil phase, would be. disposed of as contaminated proocss water.
Mechanical oil-sealed vacuum jxmps are presently in wide use in the industry.
2.2.3 Replacement of nil aqueous detergent washing operations with orgnnic-vnpor degreasing; for both the cleaning of ccnponcnts prior to assentdy and the cleaning of assemblies containing nskarol. Solvent recovery would be accomplished by distillation; tile still bottoms (sludgus highly contami nated with PCQg) would to incinerated.
Detergent elenning was tto original method used, and was largely replaced by vapor degreasing with trichloroethylene.
MONS 04 7416 -5-
However, several plants, including the newest plant, near use detergent washing.
A possible alternative (not considered in the cost esti mation because it is highly site-dependent) is the acmplete segregation of detergent-washing of components from the plant areas where PCBs are used, so that the detergent wash wastewaters would not be contaminated by PCBs. This com plete segregation would include controlled employee access and other techniques used in the pharmaceutical manufactur ing and other industries.
2.2.4 Collect the boiler blowdown water, the bleed from the closed non-contact cooling water circuit, air conditioning condensates, and contact cooling waters, in an appropriate equalization basin; filter these waters, demineralize, and return to the non-contact cooling water circuit.
2.2.5 Incinerate the contaminated process wastewaters in a
specially-designed incinerator to achieve the temperature/
residence time conditions for complete PCBs destruction (as
described previously).
It is assumed that the incinera
tion of water with only very small quantities of contami
nants requires no flue gas wet scrubbing system, but that
axhaust gas dehunidificatian would be included as necessary
(to prevent steam clouds).
A possible alternative (not included in the cost estima tions) is the complete segregation of component plating from the plant areas where PCBs are used, similar to the alternative discussed above for detergent washing of components.
Another possible alternative (not included in the cost estimation) is the conversion of conventional painting
MONS 047417
operations (which require a water spray) to dry electro static painting and labeling processes. Such conversion has already been made in the industry, but it is not known whether it can be generally applied.
Final painting and labeling of capacitors is only done cn units which have passed performance tests. Painting and labeling prior to filling, as performed with transformers, does not appear to be an acceptable alternative for . capacitors.
2.2.6 Install sanitary and personal hygiene facilities which use a mininun of water. These include waterless cleaners, closed sinks, and airplane-type or chemical toilets as appropriate. Coincinerate the reduced sanitary discharges with the contaminated process wastewaters.
X closed sink system is already used by one cxnpany in the industry, in which sink water is collected, drained, and incinerated. Use of dry cleaners prior to handwashing is also practiced at that plant. This material, as well as paper towels, etc., is collected and disposed of with the other solid wastes from the plant.
* 2.2.7 For the one plant with a waste incinerator using a wet
scrubber, collect the scrubber liquor in an equalization - basin, filter, and treat by carbon adsorption (to one ppb
or less PCBs). This treated water would be discharged to receiving waters. There does not appear to be an alternative dry process to replace wet scrubbing. This discharge would be the sole exception to the elimination of all point-source discharges from the industry. It should be noted that this single existing incinerator at one plant is for disposing of waste oils contaminated with PCBs. It should not be
HONS 047418
-7-
confused with the hypothesized "incinerators" for dis posing of contaminated waters -- these latter units should not require wet scrubbers.
2.3 General Method for Estimating Costs
The Task II effort included a detailed characterization of six askarel
oapacitor manufacturing plants (100, 101, 102, 104, 105, and 106) and of two
askarel transformer manufacturing plants (103 and 114). Hie six capacitor plants
are approximately 50 per cent of that industrial sector, and the two transformer
plants are approximately 20 per cent of that sector.
Since an the basis of
FCBs usage the capacitors are 65 per cent of the total industry and the trans
formers are 35 per cent,
the eight characterized plants represent 40 per
cant of the total PCB-oonsuning industry.
Based upon the data for the individual eight plants as published in the Task II final report, ^ and upon more process-specific data contained in trip "
reports for each of the eight plants, estimated costs ware developed for each of the eight plants for implementing each of the seven discharge-elimination technologies outlined in the previous section. Table 2-1 lists the pertinent technical data used for developing these costs, the cost elements, and the total estimated costs for each of the eight plants.
Ukidar the assumption that the,eight plants were representative of the entire industry (with respect to wastewater sources and quantities and the dis tribution of plant sizes), the eight-plant-sixn for each cost element was divided by 0.40 to estimate the corresponding value for the entire askarel capacitor and transformer manufacturing industry.
Throughout the analysis represented by Table 2-1, annual capital re covery costs were calculated based upon a ten-year lifetime and an 8 per cent
MQNS 047419 -8-
:)
o
m.i; I.).>
UI..nM* i.imu..tinn i.lrUr..kxlt)
i.m.w* i.i.m
MW.IH t.tzi.w* I.III.V*
MONS 047420 9-
, interest rate, consistent with the Task II report. ^ The capital recovery factor is then:
- u-.msi-w''. 0.1490.
(l+i)N-l
(1.08)14-1
i
In each cost category, the annual capital recovery cost is explicitly shown in Table 2-1 so that different combinations of lifetimes and interest rates may be used by the reader to generate alternate annual costs.
Consistent with average practices in this industry, the plants were treated as operating two shifts (16 hours per day), five days per week; or 260 days or 4,160 hours per year. The primary wastewater data as tabulated in the Task II report ^ and in the trip reports is in terms of gallons per day. The
necessary abatement units were sized (in terms of instantaneous flow rates) baaed upon the daily discharges and the operating hours above; in seme cases, this sizing was not consistent with assumptions in the Task II report ^ of 24
houTBper day and 365 days per y. ar.
--
TWO parameters in this analysis were seeded on a plant-by-plant basis using FOBS oonsunption rate as the size factor. These two parameters are the muter of vapor degreasing units needed end the nunber of production employees. Sinoe the scaling factor (PCBs use) has been treated as proprietary data through out the Versar study, the presentation of the corresponding unit costs in Table 2-1 is necessarily not explicit, for all other cost elements, however, every effort was made to make the unit costs very explicit.
2.4 Development of Estimated Costs
2.4.1 Posts for Segregation, Cooling, and Recycling Non-Contact Cooling Water "
The primary data in Table 2-1 is the flowrate of non-oontact cooling water. These data were taken directly from the Task II report except for Plant 101. This plant already has a recirculating cooling water system with an evaporative-type cooling tower and with a daily makeup water addition of 3,000 gallons; it was estimated that the recirculation rate in this plant is 250,000 gpd.
MONS 047421 10-
Ms added costs should therefore be incurred by this one plant for cooling water segregation, but this plant (as all the rest) would require the installation of an enclosed oooling-ater/air heat exchange.
The capital costs for segregation, for the remaining seven plants
wen taken directly from the Task II report.
These costs were generated on
the basis of plant acreage (as a scaling factor for the extent of existing piping
and sewers) as well as on the basis of the flowrate of non-contact cooling water.
The capital costs for the dry cooling tower were based upon the instantaneous flowrate of non-contact cooling water (in gpn) for each plant, using the correlation shewn in Figure 1, which was taken from the Task II report.
The annual maintenance costs for the segregated water system
were assumed to be the same as existing maintenance costs for unsegregatod systems
-i --hence, a net cost of zero was used. Per die dry cooling tower, annual maintenance
costs were taken as 20 per cent of the dry cooling tewer capital investment,
consistent with the Task II report.
Electrical energy costs for the water
side of the dry cooling tewer, for the air side of the dry cooling tewer, and
for added punping needed for recirculation (as opposed to once-through) of the
water; ware calculated on the basis of 0.7 IIP (total) for each gpm of water,
4,160 hours per year of operation, and 00.02 per KWH.
2.4.2 Posts for Mechanical Vacuum Pumps
The characterization of' the eight plants in the Task II effort (final report^1' and trip reports) resulted in the determination that only one of these plants. Plant 105, made significant use of water-sealed vacuum puips and/or steam ejectors with condensers. The other seven plants utilize mechanical vacuum puips for the impregnation chambers. Altliough vacuum is generally used in PCB storage tanks and possibly for other unit processes, the major use appears to be in the impregnation step.
,, It was estimated that Plant 105 has ten impregnation tanks, each of approximately 128 cubic feet in volume, and each served by a vacuum pump that is required to reduce the pressure from one atmosphere to 0.1 torr in 5 minutes.
-U-
HONS 047422
I
Then for each prip,
~_ M
_ vo ri
0 6o pep/7<so T^r
Where: Q - constant volumetric pumping-rate, cubic feet per minute M mass air evacuation rate, pounds per hour P " pressure in tank, torr, at time t, minutes P0 " density of air at one atmosphere - 0.0749 lbs/ft' P^ " initial pressure = 1 atm " 760 torr Vo " volute of tank, cubic feet
Hence, for VQ - 128 and for P 0.1 at t S,
Q " 170 p " ip- In 7,600
Q - 230 cubic feet per minute and M/P - 230/170 - 1.35 pounds/hour/torr
A typically suitable mechanical vacuum pump is the Stokes/Pennwalt Corporation "Microvac" oil-sealed single-stage piston pump model 412H, with a displacement of 300 cubic feet per minute at a pump speed of 490 HFM. This pug? has a constant performance of 270 cubic' feet per minute from 760 torr to 10 torr, and a slowly decreasing performance down to 230 cubic feet per minute at 0.1 torr. It is driven by a 10 HP motor running at 1800 KPM, and uses 2 GPM cooling water. The vacuum pwp has an oil capacity of 10 gallons. The f.o.b. cost, including motor, V-belt drive, belt guard, oil solenoid valve, initial charge of oil, gasballast, and visual oil flow indicator, is $4,680.
An Independent cost estimate was made using the size factor M/P " 1.35. According to Huff, ^ the f.o.b. cost is about $4,800, closely checking
the first cost estimate. Using $4,680, the installed cost is calculated according
to Huff ^ to be:
-131
MOMS 047924
installed Cost * 55.2 x (f.o.b. costs)0'678 - 55.2 x (4,680)0*678
- $16,830.
This muter is used as the capital investment per vacuum pump in Table 2-1. Again according to Huff, ^ the annual maintenance costs are
9 per cent of the capital costs, or $1,515 per pimp. However, the system (e.g., steam ejectors) which the mechanical vacuum punp replaces has a maintenance cost which must be subtracted from the $1,515 to derive a net maintenance cost. According to Huff, the f.o.b. cost of a steam ejector with Vi/P of 1.35 is $5701 this results in an estimated installed cost of $4,090. At an annual maintenance cost of 2 per cent of the capital cost for steam ejectors, ^ this cost would be $82. Hence, the net annual maintenance cost for the mechanical vacuum puip would be $1,433.
There would be a net energy saving for mechanical vacuum punps over either steam ejectors or water-sealed liquid-ring vacuum paips. For each, evacuation cycle, the 10 HP mechanical pimp uses
(10 HP) (o.745 gj) (g| Hoursj ($0.02/KWH) $0.0124 of electric energy
Assuming one cycle per hour and 4,160 operating hours per year, the annual electri cal cost would be $52. In comparison, an equivalent steam ejector would require, for each evacuation cycle, about 22 pounds of steam (which is calculated according to the method of Patton and Joyce) ^. At a steam cost of $2 per thousand pounds, the steam cost per cycle would be $0,044; or about $175 per year. Hence, the net saving would be about $123 per year per inpregnation tank. For the purposes of this analysis, these small net energy savings are assumed to be negligible.
2.4.3 Posts for Vapor Degreasing The capital investment requirement to replace detergent washing
with vapor degreasing at Plant 101 was estimated by that plant to be $55,000.
; MOWS 0*7425
14-
that plant presently employs detergent washing in two areas: in the initial cleaning of purchased capacitor components (cans, covers, and other metallic ccnponents) to rerove oily protective coatings; and in the cleaning of the outer surfaces of caiplete assembled capacitors after soldering and plugging.
Of the other seven plants characterized in the Task II effort, four presently enplcy no detergent washing (P.lants 100, 102, 106, and 114). Plants 103, 104, and 105 use detergent washing techniques for only sene cleaning operations: Plant 103 utilizes a kerosene flushing technique on transformer subassemblies prior to filling with PCBs, but uses sane detergent washing as well; Plaint 104 uses trichloroethylene vapor degreasing of seeded capacitor sssanblies but uses either vapor degreasing, ultrasonic cleaning, or detergent washing of metallic oenponents prior to capacitor assenbly; and Plant 105 utilizes trichloroethylene vapor degreasing of metallic components and detergent washing ~ of ocnpleted capacitor assemblies. The capital investment requirements for re ----- placing detergent-washlna-at Plants 103. 104. and 105 were estimated using the Plant 101 nutber as a basis, and scaling by both quantity of PCBs consumption . and the estimated present mix (at each plant) of detergent washing vs. vapor \' degreasing.
The annual maintenance costs for vapor degreasing equipment were estimated as 6 per cent of the capital investment, the annual costs for fuel in the vapor degreasing boiler and solvent recovery still were estimated at 2.5 per cant of the capital investment; this is equivalent to vaporizing about 600 pounds per hour of trichloroethylene at Plant 101 (heat of vaporization of 103 Btu/lb; 20 per cent overall thermal efficiency, 4,160 hours per year, and $1,083 per thousand cubic feet of natural gas).
2.4.4 Costs for Treatment of Blowdowns and Miscellaneous Mon Process Waters
The daily quantities of water used as boiler feed makeup for
Plants 100, 104, 105, and 111 are listed in the Task IX Final Report.
FOr
Plant 100, the boiler bleed discharge is half of the boiler feed makeup; hence,
Table 2-1 shows half of the boiler feed makeup for the above four plants as waste
water to be treated and recycled. The boiler bleed discharge for the remaining
>
'
-15-
MQNS 04 7426
tour plants was estimated from the first four data points based upon PCBs ccnsurption as a scaling factor.
. With the installation of a recycle non-contact cooling water
circuit, a blowdown fron this system would be required for each plant. The flow
rates in Table 2-1 were taken as one per cent of the non-contact cooling water
circulation rate.
'
Plant 103, as shewn in the Task II report, tie) has a discharge
of 183,000 GPD of contact cooling water. The sources of this discharge are contact
cooling in welding and plating operations and in phosphate treatment of steel
surfaces prior to painting (as discussed in the Versar trip report for this plant).
It was estimated that 90 per cent of this water, or 165,000 GPD, is relatively un-
oontaminated contact cooling water, subject to treatment and recycle; and that the
remaining 18,000 GPD are relatively contaminated process waters not amenable to
treatment.
The technology to eliminate these discharges (of boiler blow down, non-contact cooling water blowdown, contact cooling waters, and minor amounts of air conditioning condensates, etc.) is to collect these waters in an equaliza tion basin, filter than through multimedia beds (e.g., sand and anthracite), demineralize than with a ocnfeination of ion exchange resins, and then recycle these waters to the non-contact cooling water circuit.
The capital investments required for pretreatment (equalization
and nultimedia filtration) shown in Table 2-1 are based upon the pretreatment curve
of Figure 1, which was taken fron the Task II Final Report.
The capital
investments required for donineralizaticn are based upon the demineralization curve
of Figure 1, which was taken from a prior Versar study for EPA.
The annual
operating costs for equalization and multimedia filtration, including operation,
maintenance, and electrical pewer, were taken as 3.3 per cent of the pretreatment
capital investment, consistent with the estimates of the Task II report.
The
annual operating costs for demineralization (labor, maintenance, resin costs, and
chemical costs) were taken as $1.00 per thousand gallons of water treated, cuuieiisurate with a total dissolved solids content of about 1,000 mg/liter. ^
) ' HONS 0<7'*27 -16-
2.4.5 Costs for Treatment of Scrubber Water from Waste Incinerator ' ' ' at Plant 103~
The waste incinerator at Plant 103 is the only one in the in
dustry. This plant has a scrubber liquor discharge of 122,000 GPD. The pretreat-
mant technology for this wastewater.is the same as for the blcwdown waters des- , .
cxibad in the previous section: equalization and multimedia filtration. Hence,
the capital Investment requirement is based upon the pretreatment curve of Figure
li and the annual operation costs were taken as 3.3 per cent of the capital
investment.
The capital investment for carbon adsorption is based upon the
corresponding curve of Figure 1, which was taken fran the Task II Final Report.
Annual operating costs for carbon adsorption (labor, maintenance, carbon costs,
and pwping costs) were taken as 45 per cent of the capital investment, equivalent
bo the operating costs in the Task II report. ^ ^
. .
2.4.6 Posts for Reducing Sanitary Wastewater Quantities and for Incinerating Sanitary Waters and Contaminated Process Waters
- Table 2-1 lists the quantities of contaminated process waters from each of the eight plants surveyed in the Task II effort. These wastewaters include vacuum pump condensates, laboratory wastewaters, and wastewaters from the various surface treatment techniques used in the industry (plating, painting, phosphatizing, and fluoride treatment). For Plant 103, these process waters in clude an estimated 10 per cent of the "contact cooling water" discharged; it was previously estimated that the retaining 90 per cent of these waters could be treated and recycled. The technology f6r eliminating these process waters is to incinerate them for two seconds residence time at 2200F, thereby destroying any FCBs. No wet scrubber would be required, as the flue gases should have only very minor quantities of particulates and HC1.
Sanitary wastewaters (including personal hygiene wastewaters) amount to rather large quantities, as Table 2-1 shows. These are actual data for each plant, except for the sanitary wastes from Plant 103, which was estimated h--d upon plant size. The technology for eliminating these wastewaters is in cineration together with contaminated process wastewaters. However, it was al90 assured that prior to incineration, the quantity of sanitary wastewaters would be reduced to an absolute minimum. All lavatory sinks would be closed, with the axinun use of waterless hand cleaners.. Toilets would be replaced by airplane-type
17- MQNS 047928
OT chemical toilets. It was estimated that such water-saving techniques would
result In a minima sanitary wastewater flow of 10 gallons per production employee
per day. The timber of production employees at each plant was estimated hased '
ipon PCBs consumption as the scaling factor, using the actual number of production
employees at Plant 106 as a baseline. It was also estimated that the capital
'
investment for Installing the closed sinks and toilets would be $1,000 for each
20 employees. The annual costs for maintenance, chemicals, and supplies was estimated
as 16 per cent of the capital costs. the capital investment for the incinerators is based upon the
total of contaminated process wastewaters and projected sanitary wastewaters. The
(IV)
incinerator curve of Figure 1, taken from the Task II report,
provided the
basis for capital costs. The annual labor and maintenance costs were taken as 20
par cant of the incinerator capital investment. Fuel costs per year were based
upon the gallons of water incinerated per year, assuming 260 operating days per
year. It was assured that a total of 2,200 Btu were required per pound of water
to achieve 2200F, and that the fuel (natural gas) costs $1,083 per thousand
cubic feet (or per million Btu). These unit values are consistent with the Task II port.(W
Since the contaminated process waters and the sanitary wastewaters would be coincinerated, the capital and annual costs far eliminating each were calculated from the total costs on the basis of relative quantities for each of the eight plants.
t
2.4.8 Quantities of Eliminated Discharges
Sable 2-2 lists the current wastewater discharges from each of the eight plants surveyed in the Task II report. Qe) These quant. ities were extra polated to the entire industry on the same basis as the estimated costs. Based upon the technology discussed previously, all of these point-source discharges would be eliminated with the exception of the waste incinerator scrubber water. Which would be discharged after treatment to reduce the PCBs content to one part per billon.
18-
MONS 047429
Sanitary Mumtir wou
Mli M
AM 150
03,000 0 0
90,000 0
300 44,300
730,100
na* 101
390,000 0
0,000 3,900
0 0 1,900
20,000
AM 102
300,000 0 0
5,000 0 0
53,000
445,000
time 103
1,040,000 0
2,000 130,000 122,000
11,000 50,000
2,020,000
V&JOt 104
1,195.000 0
25,000 15,000
0 0 10,000
1,245,000
Ha* 105
307,000 44,000 200 7,900 0 12,900 <5,000
515,200
Platt 105
327,000 0 0
3,000 0
5,000 5,000
340,000
na* 114
35,000 0 0
100
4,500 9,300
51,300
fttil of t Plants Sunojod
4,055,000
243,100 122,000
40,200
9,505,200
Misuy Totals
12.215.000 110,000
14,020,500
. 2.5' Estimated Cbsts for Hypothetical Plants
'
. Three hypothetical plants were defined on the basis of PCBs oon-
urrptioni
_
..
Large Plant'
2,500,000 pounds per year
Medivm Plant
500,000 pounds per year
Snail Plant
100,000 pounds per year
Bach of these hypothetical plants is assumed to require wastewater-elimination techniques in all wastewater categories; e.g., these plants each require an Upper-bound set of costs.
. Table 2-3 lists the individual wastewater quantities and the individ ual capital and annual cost elements for each of the three plants and for each of the several technologies for discharge elimination. The costs were derived in the same manner as previously described in Section 2.0, and include the cost elements of Section 3.0.
Figure 2 graphically shows the total capital investment and the total annual costs as functions of plant size.
-20-
HONS 047431
. to#9Mioor
I
Hilar and ih|miUm llodwa. kU ao
l Mow prtfMWt
, 1
'
Wvlmio !... Oa Miaul iMUltouoi
o
toOwt Wl OW.IIM cballna Mw, NiHtatiR cm uti wtar, top. lm. far
VOMf< lIMttp. lhult Dliwry Cwbewlutvi
tao (Hi MaW
M(W'Ms>wMlMON^f.n'l9n-->>>'
ni rt>ti f IStM ft iwl *
niiaw *|n,)vi, nyt C*lm M*rf !.****. Ohm 'r*> w, T~`i9i
OOHw*. lImwo. \-
4*0. Iw. - tMMmwalK total CHS I--
htwl Hr. rM total Aratwl *> 2<**l Caw. *-- (mid 0-r. n-` total MN4< >** total M*Ml IM>
do. Im. - CtrHvi Ml* **!
owl no. iA*w*n
jaaoal cap. om*. n
Pool C(*r, Onto > "*'
VMM Mo*wt iv-io * I9"*r*-i
klal C<p<
A **
QhimI 0*r. IJnll - i"H
fowl hvral IKm - !***
Mai Mm*I <MN
no Phhi Hrtar IN tanataw HtUf IH*H 4M. MO. AKim IK>(nH4 Op. Im. Mr >M*r 4fim Will Cap. Am. (M liaii dr- Ctot
OOlHiiUnfHiiir IlMml
n 1M*( it IKIIOMA
CIMOl 14 bCtfrlM* Its top- lm. JMwal top. <a*. toata Will Mw a Hint. UaU
Will rwi Oau total tout onto - I*-mi. IrUn Cop. Im. - Onury toWM. knal ou - riaiioarf total C0|s lm. lailMiv tottl Pm. CM4 4MII.IIT total Of. Im. Aw nmu Sl#f Mai km. oni> im n-w. >*it#r total Capital Inia iumni total towaaal <ka
. Im. - ouwmai ni'i'
. im. ml. Irani'* *1 topltal Imnw..'*
Law OUrc a.ioo.ooo
2co un
mmiw rime IOO.OOO
uw/yr row
1,041 UI.IM in,wo
00.000 to
m.m> 40,*> 02.M ' N.W IM.fH
4,000 77,400
|t.M Y,M
2?!ooo
w.ooo
ct.ooo 10.000 l.no 19,700
9.000 40.000
o.wo
i.om 0,400
Mail Olaft lto.000 12to>r *a um
W,N 41.7
t.tN
t.aoo i
n.Mt i,'A0 1.400 >.900
i.SM 10.000
i.yw m
2.700
MI.1M r?.u
II3.T30
4.200
>44,.129000
o,*n U.MO 47,000
290.000 lit
700.000 122.000 ou.cm 104.209
11.200 UMOO
19.700 99.M0 70.200 200.000
19.000 7.Mo 79.409
2.400
111.,110000 l.Mo 1.000 19,000
M.000 92.1
>29.000 40,000 207.000 19.000 7,000 42.000 7,100 11.400 20.000 71.400
2I.4M 2,200 to.UO
00
9,1t0o0o 400 TOO 9.100
10,000 10.4| 00.000 29.000 111,000 11.400 1.000 14.400 I.TOO U.MO 19.000 11.400
91.200 4.790 9.000
0.210
n,rt 12.0
990.000 92.100 79,000 0.190,000
1.290 0.210 0.91 I09.PC0
101.100
>20,400 >11,200 >92,200 19.100 19.900 91,400
2.109,IW 771,000
19.400 4.200 29.100
12.400 0,100 17.W0
-21-
mons 047<t32
MONS 047433
2.6 References for Section 2.0
X.. Assessnent of Wastewater Management, Treatment 'technology, and Associated Cbets for Abatement of PCBs Concentrations in Industrial Effluents, Versar
Inc., Final Report, Task II, EPA Contract No. 68-01-3259 (Feb. 3, 1976)
a. Pages 53,54,76,77,76.
.
b. Pages' 43,45,70,71.
c. Page 213.
d. Page 224.
..... e. Pages 45 and 71.
--
f. Page 211. - -................------- ----------------------------- ;-------------------
g. Page 215.
h. Page 217.
'
i. Pages 162,163.
J. Pages 171,172.
k. Pages 214 and 216.
2. Process Plant Construction Estimating and Engineering Standards Manual, Vblume 5, Richardson Bigineering Services, Solano Beach, Cal. (1974).
3. Huff, George A., Jr., Selecting a Vacuun Producer, Chemical Engineering, March 15, 1976, p. 83-6.
4. Patton, P.H., and C.F. Joyce, How to Find the Lowest-Cbst Vacuun, Chemical
Engineering, Feb. 2, 1976, p. 84-8.
.
5. Private CCmrainication, Plant 101, May 28, 1976.
.
6. Viersar Inc., General Technologies Division, Draft Development Document for Effluent Limitations Guidelines and Standards of Performance, inorganic
Chemicals, Alkali and Chlorine Industries, EPA Contract No. 68-01-1513 (June 1973), pages VIII-18-22.
-23-
MONS 047434
3.0 PCS RJNQFF FROM STORAGE AND MATERIAL TRANSFER AREAS
3.1 Problan Areas
.
Stormwater or meltwater runoff beocmes contaminated with PCBs at vari ous points on the premises of capacitor and transformer manufacturing facilities:
1) Unloading areas where raw or pnsnixed PCB materials are trans ferred fran flatbed trucks, tank trucks or rail tank cars to drun storage areas or tank farm storage areas. Very few unloading areas are covered or have methods for containing
' minor leaks or spills or accidental discharges of large volumes of PCBs; the result is that PCBs are washed fran
. these areas into the environment by rainwater runoff and snowmelt. Horizontal transport to running streams or vertical percolation to the water table results in permanent PCS contamination. Topographic conditions, soil texture and ccnposition, and local precipitation rates all help determine the rate of PCB transfer and contamination.
_
2) Areas where various solid wastes are stored including drums filled with solid or liquid PCB wastes, spent clay (attapulgite or fuller's earth) filtering material, scrap capacitors or capacitor interiors, scrap transformers or
't
transformer interiors, spill absorbent materials such as floor dry, rags, and newspapers, and sludges fran oil separators and other water treatment systems. Storage is generally in the open and may be on a permanent basis or until the materials are hauled to a landfill or incineration. Again, runoff carries PCBs from these solid waste areas into the environment by the same mechanisms as delineated above.
3) PCBs, originating as air emissions from the plant and from undefined remote sources, reaching the ground, roofs, parking
I MOWS 047435 24-
lots/ and outlying areas. An intermedia transfer is required
. prior to the' PCBs becoming part of the stormwater runoff. This
category will not be considered as arising directly from plant
operations.
-
3.2 Solutions to Runoff Problems
The obvious solution to the above water contamination and concomitant transport of PCBs to the envirorment is to prevent water contact and mixing with PCS materials. Enclosures around unloading and storage areas, with curbs and Impervious floors, will prevent PCB loss. However, the containment of KBs Which settle from the air is more difficult, until air emissions are con trolled, diversion of uncontaminated runoff waters around facilities by dikes and curbs can be envisioned, and the subsequent-control,-storage, and possible treatment of all contaminated runoff waters may be considered. However, PCB Control techniques applicable to PCB contamination from intermedia transfer sources are not within the scope of this study.
3.3 Enclosure Requirements
Handling methods of PCBs and PCB wastes, both solid and liquid, are largely a function of production volume. Very large operations unload raw PCBs Cron railroad tank cars to storage tanks; over 20,000 gallons are transferred Cron each car to the "tank farm" area. Large volumes of clay filtering wastes are also generated at very large plants,'as PCBs are filtered on site. At intermediate and snail sized operations PCBs are generally delivered in tank trucks (4,000-5,000 gallon capacity) or 55-gallon dnms, and are premixed and filtered; obviously no filter wastes are generated. In developing costs for Tables 3-1, 3-2, and 3-3, Versar has made several assumptions regarding materiel unloading and waste storage requirements:
1) Operations using more than 1,000,000 pounds of PCBs per year generate more than 175 55-gallcn dnms of liquid and solid ' wastes per month, and will require a large storage area.
-25-
hONS 047436
Table 3-1 Building Costs - Waste Storage Areas
Large Building (50* x 100')
Footings
.
Slab (6* thick) '
Curb (6" high)
Metal Siding (10' high)
Metal Roof (12:3 pitch)
Structural Steel
Misc.
'
Median Building (50' x 50') ........... Fbotings -- -- Slab (6' thick) Curb (6" high) Metal Siding (10' high) Metal Boot (12:3 pitch) Structural Steel Misc.
Small Building (25' x 50') Mootings Slab (6" thick) Curb (6" high) Metal Siding (10' high) Metal Roof (12:3 pitch) Structural Steel Misc.
,
$ 1,203.00 2,250,00 549.00 4,050.00 7,020.00
17,850.00 2,530.00
$35,452.00
$ 802.00 1,215.00 366.00 2,700.00 3,510.00 8,925.00 1,650.00
$19,368.00
$ 601.00 725.00 274.00
2,025.00 1,755.00 4,462.00 1,605.00 $11,447.00
-26-
MONS 047437
I I
)
Table 3-2 Building Costs - PCB Unloading Areas
1) Railroad Tank Car (20' x 70')
Footings Slab (12" thick) Malls (4' high, 8" thick, concrete) Metal Siding (10' high) Metal Roof (12:3 pitch) Structural Steel Misc.
2) Tank Truck or Flatbed Truck (15' x 30')
Footings'
Slab (6" thick)
Nalls (2' high, 8" thick, concrete)
Metal Siding (10' high)
Metal Roof (12:3 pitch)
Structural Steel
'
Misc.
$ 721.00 1,400.00 1,872.00 2,430.00 2,079.00 4,998.00 2,735.00
$15,875.00
$ 361.00 279.00 471.00
1,215.00 648.00
1,606.00 1,518.00 $ 6,098.00
27-
MONS 047438
PfKlttr Znduiuy
*
Manga Building*
Urgs Usor* (1) (>1,000,000 UMAt)
Hdlvi Dun (l) 000,000-1,000,000 iba/yz)
Moll UMn (5) (<100,000 Iba/yr)
fOMf (15)
IHCrlal Transfor Building*
Urr Unn (0) (1 ailUcn Iba/yr)
Mdiw 0 Brail Unn (11) (<1 aUlion ltoa/yr)
*0B" 0,1
ltmteigr Industry bang* Building* KipUMf (4) (bit000,000 lbs/yr) Mdlus Unn (7) (100,000-1,000,000 ltos/yr) MaU Vamea a) (<100,000 lfaa/Vr) (7)
ttms no)
HH*rti,l )t*u(r Building* Lug* Unn (4) 01 aLUlan iba/yr)
Matin Brail Unn (14) (<1 aiiUcn iba/yz)
foaad at)
good, kb un* ocumer (37)
lkU M
Iwtotry costs
capital Ooat*
.
Mr User
total industry
Amial Grata (Ot 0 30 VT.)
Per User
total Industry
,* $35,453
15,340
11,447
$ 303,010 114,309 57,235
$3,010 1,575 1,107
0 20,52$ 11,950 5,135
$ 457,050
$ 40,013
15,075 4,090
137,000 >.87
154,070
1,019 031
12.552 0.531
$ 15,753
30 You Grata total Industry
$ $71,500 337,000 130,700
$ 133.300
255,043 .. HH.M $ 314.003
035,453 15,300 11,447
15,075 0,050
0
141,000 135,570 0,135
0 350,513
03,500 15,373 f 14t|B72
$3,010 1.575 1,107
1,015 021
0 14,404 13.135 9,105
$ 30,459
0,470 rC54 f IV7
0 309,390 370,500 101.300
9 729,110
139,530 173.090 9 103.400 $2,340.493
.90.
MGNS
I
Liquid KB transfer areas will require a structure large enough for a railroad tank car.
2) Intermediate sized operations using from 100,000 to 1,000,000 pounds of PCBs per year will require less waste*storage area as they generate approximately 75 55-gallon druns of liquid and solid waste per month, liquid KB transfer areas will require a structure large enough for a tank truck or flatbed truck to unload premixed and filtered liquid or drurmed PCBs.
' 3) Sknall operations, using less than 100,000 pounds per year will require minimal waste storage area, as avail able enclosed space in the manufacturing facility can
---------often be utilized. Unloading facilities will require a structure large enough for a flatbed truck to unload drums of premixed PCBs.
-
4) All facilities will remove liquid and solid wastes to incineration or landfill on a monthly basis.
5) All building structures will include slab floors, curbs, footings, either part concrete and part metal walls or all metal walls, metal roofs, steel superstructure, two normal access doors, one ^oll type steel door for vehicular access, rudimentary lighting, no ventilation, no insulation and no windows.
3.4 References for Section 3.0
1. Richardson Engineering Services Inc., Process Plant Construction Bjtimating and Engineering Standards, Solana Beach, California,
2. Vfersar Inc., Final Report, Assessment of Wastewater Management,
Treatment Technology, and Associated Costs for Abatement of
tate Concentrations in Industrial Effluents?
1976.
-29-
MONS 047440
I I !` ' * * I
3. Personal Conversation with Dick Hollends, Vice President ot ' Engineering, Jard Oorp., Bennington, Vermont.
4. Personal Conversation with Bill Montgomery, Plant Engineer, General Electric,'Hudson Falls, New York.
I
]
i
i
-30-
MONS 047441
4.0 SUMAKY AND TABULATION OP TECHNOLOGY Al ESTIMATED COSTS FOR THREE
ALTERNATIVE APPROACHES TO REDUCTION OF PCB3 IN EFFLUENTS FROM THE CAPACITOR AND TRANSFORMER MANUFACTURING CATEGORIES
4.1 Description of Alternatives
The technology and estimated costs developed under Task II of Contract
No. 68-01-3259, as contained in Reference 1 and Sections 2.0 and 3.0 of this
document, were reviewed and utilized to develop three alternative approaches to
FOBS reduction in effluents from the industry. These alternatives cover a range
of both costs and FCBs reduction, and also reflect consideration of technology
availability.
.
The eight individual plants included in the analysis were those plants in the category for which sufficient data were available (fran plant visits, tele phone contacts, etc.) to justify the obst estimations. Six of these eight plants discharge wastewater directly to waterways. Five other plants in the category are known to discharge directly to waterways, but sufficient data on these facilities as required for the analysis were not available to us.
To our knowledge there are presently no cases of sanitary water (personal hygiene, toilets, etc.) discharge to waterways in this industry category; all such waters are believed discharged to municipal sewage collection and treatment systems. Therefore, although costs were developed for sanitary water under the zero dis charge case of Section 2.0 herein, treatjnent of sanitary water was not included in ary of the three alternatives of this section; treatment costs for sanitary wastewaters are thus zero far all three alternatives.
The three alternatives may be summarized, in terms of process change, technology and treatment of the several types of wastewaters by use, as follows:
MUNS 047442 I -31-
Wastewater Type
_________ ______Typo of Technology Applied
Alternative A
Alternative u
____________ Atlemative C
Non-Contact Cooling Water
Steam Jet Condensate
Detergent Washing Water
Boiler Blowdowns
incinerator Scrubber Water Process Associated Wastes* Sanitary Wastewaters Rainfall Runoff
Cool in Closed System and Recycle
Replace-Steam Jets with Mechanical Punps
Replace with Solvent Vapor Degreasing
Filter, Demineral ize and Recycle
Pretreatment and Carbon Adsorption
Pretreatment and Carbon Adsorption
Mo Treatment
Enclose Areas
Pretreatment and Carbon Adsorp tion
Pretreatment and Carbon Adsorp- , tion
Pretreatment and Carbon Adsorp tion
Pretreatment and Carbon Adsorption
Pretreatment and Carbon Adsorption
Pretreatment and Carbon Adsorption
HO Treatment
Enclose Areas
Segregate and Discharge Untreated
Pretreatment ai d Carbon Adsorp tion
Replace with Solvent Vapor Degreasing
Discharge Un treated
Pretreatment and Carbon Adsorption
Pretreatment and Carbon Adsorption
No Treatment
Enclose Areas
4.2 Presentation of Estimated Cost Tabulations
Estimated casts for tile three alternatives are tabulated as follcws:
Alternative A - Table 4-1 Alternative B - Table 4-2 Alternative C - Table 4-2
.
i ,
' 4.3 Discussion
'
' In general, the relative costs and effective reduction in PCS discharges
for the three alternatives can be svmrrarized byi
Alternative A (Process Changes, Maximum Recycle)
Alternative B
(Maximum Use of Carbon Treatment)
Alternative C (Minimum Treatment)
Relative Cost
Mid-level .
Relative PCB Reduction Highest
Highest Mid-Level
lowest lowest
[ i !
* Process associated wastes include:
~
less than 1009 gal/day rinse water from hot solder dip (1 plant)
.* more titan 1000 gal/day phosphatizing bath wastewater (2 plants)
more than 1000 gal/day tin plating wastewater (1 plant)
lees than 1000 gal/doy fluoride bath wastewater (1 plant)
less than 1000 gal/day paint stripping wastewater (1 plant)
` more than 1000 gal/day unspecified contact cooling water (1 plant)
32-
J *
z
o
*
k*. tar
tDopU. lMM4. Um*i M> r oMwtMim v
Hanoi Cm. k. Mi
MIMaMalIMlMatr.rOMKiU
Mul Mi (Ml
m mu* am* m
C.4M U.MC
tt.M u.m U.K Im).,*mm
la.M a.im ]|,M mn..mm
M.M m.m a.M ,m
n.m Km i.m UtH u.m
km
i.m
n.m i,m.m Ln.m ).m.M
m.m
tmal IWi flNU
Mat CM w Til<WN total CM M ftoMMKt c*. M.'wot. i rut. Cap. M.-MwflUM kUl Cap. iMlVrM
MImm.. Ctiap..MOmwu.4'MmlIL. I* HWitt..
total MM. MftfsH. * nit. am. cp. avu.paii. Dm. Mvtal*. tout Inutl Ml
a.m m.m a.m
).m a.u* >,M i.m t.M! a.m
i.m n.m t.M i.m U.1M
NO . i.m . I.1M
u*m
m.m a.m i.m n.m i.m
ui.m n,m i.m u.m I.m
l,m u.m tm
m I.IM
i.ut.m 1U.W u.m n.m m.m its. m m.m tu.m 5M.M* Ml
I.Ut.tM ot.m
Mtl.m
o MVMri
Cap. tor.-Utt-l. I flit. Cap. M.Mi MM*, total epiUi IKMMM
im. cm- Mw.mi. t rut. am. Qa-r. <b.i>.cait> i rut* tool am. o*vta-npt. a rut. Am. Cp. * * 1' " Dm. t*. Q total am. total anal (Utl
ii, m u.m .iw <1. m
IH.tM. .m m.m IV. CM tt.lt* Lit, M lli.UC
* O
Z
V (M tat/Uarf Cap. tan. bml. t nit Cap- Mr. 6aua Mp. total Capital >nrut Dm. C*. Mmvry-baMl. t PUt. tap. Cnr. Ov**r<f*i. * nit. toot am. oiou - aml. t rut. taa. top. tamtirr * tom Mop. tap. tar. M - tortm Nap. total Am. Oaata * toto Mop. tout taut Qu
m.m M.m .m
u.m i.m u.m u,m u.m
CM .J
M.M9 M.OM n.m M4| MM 1C, MI mm I.m U.m
u.m i.m i.m I.M9 i.m i.m u.m n.m
n.m 41.19 m.m u.m 19. MI M.m M.in Uf.m
1C4.I tn.xi m.m t*iu.m m.m n.m Mi.m
m.ui I19.lt! IM.M lll.IM
M*m
ovm
I.M
V 7 7 1 *'0
tala Amtf mop CM 1 kpf*lM Hap
Ctaapw. ltaOr.CXSiaMraPaa* pMtUalIUatfav
top. lav. racial No. U4f taui - MtrLU torn, cm*
1*1.941
u.m i.n i.m
M.m
n.iu l.Mt u.m i.m
n.iu MM u.m 1.111
n,i l.M u.m l.uc
M.I91 MM ii.m i.m
(91.411 n.m Ml.449 u.m
im.i.i . i.m.t
HONS 0 4 7 4 4 5
nuVwk i Cuba* Mm** feb. AU fimo . MtMy
( iu hm tv n* km . au n . mm cm iwwvi
*5*
e*. .*otmi. t mlr
Am.&. iwmri >mi. mt
Am. <*, Oafftiirf 0 rut. Cap. 2a*.<srton Maocp. . Am. Op. iwayCittwi Nh^, Am. H. CmfCuUst Nm,
I'*- O- Oat*>fcVil. rut.
IN. CHtKMai fclaocp. fcul Op. |M>.
Toot Am. On
Mttqr Hwur
cn, knur Kitm 9M*1 or. In*.
feul Am. Otw
v
M* AntfAtKi telflPM Ams* (MaM> W a lucap* mu, idi
Oo A Xrptcvtous nm
Cap. tmr. ta;*)t MUtaf Am. Out KO*ft ftilitin* Op. lav. natcrUl Trn*. SU|. Am. Com KtutUi Trm. U%,
tODIA
IMjI Cap. Imesvwat 1ui Imui Oats
'
nOafiWkH^IMUMCltMd tfMmm H
WSmt m
(TIM rti.i
MM.M M.M M,M M.M 30.740 117.000 th.mo 115.740
1.110.000 01.000
44.100 0
31.492 7.010
11.071 1.011
1.1U.377 490.225
IM 101
10.100* 10.1
10.000 11.410
7.700 30.000
4.173 13.000 14.110 14.773 1U.000 32,003
1.100 0
11,700 1.171 4.HO
ou
141.400 >1.470
rm* Ml
lloo MS
VM* IM
Itat 109
flat
OIN
IM . U4
31).000 401.0
1.050.000 110.410 ii.soo 109.000 24.141 74.210 107.110 M.0U
1.211.000 200.701
13.000 0 0
31.412 3.010
is.ro 1.011
1.300,327 212,020
1,170.090 3000.0
4,100.000 070.100 139.000
1,000.000 141.C00 490.000 09,900 M.M
V904.900 1.404.900
90.000
11.491 3,010 19.4)1 1.017
1,991,127 1.400.739
1.239.000 UN.O
2.090.000 020,010 09 .MO 900,000
74.100 229.OH 110.190
211.900 1.790.000
000,010
491,200 470.0
1.190.000 171,390 34.900 179.000 31.095 07.710 209.190
110.001 1,341. ON
122,019
10.000 0
0
49.000 0
31,493 3.010
ii.ro 1.010
39.492 3.010
11.171 1.017
1,401.137 1.300,337 014.009 327,770
331.000 340.0
TOO, ON 134.IN
37,ON 114,ON 32.390 07.1N Ml. IN 07.190 1.090. ON 290.110
1.0N
17.3(0 i.ro 0,071 021
1.071,400 291,9*0
42,CN 44.0
ro.oN 31.274 (,M 49.0CO 4.701 27,290 37.970 24.791
215.ON 04.141
1.3N
25.452 3.014
11.071 1.419
304,327 47,700
OH** Sflm UmiajiN
i.rn.iN 5)11.0
1I.4M.0N 1,047.ON 171.ON I.741.0N 147.107 3.054.190 7.317.ON 1.401,497
14.741.0N 3.471.097
237.740 0
211,440 21.440 107.4(0 10.950
19,101,070 3.090,090
9 * * V 0 SNOW
QogojaM mn oua art- -- CWU.I --Itoy >, WO Of. tor. ter togrvpttal tol Cm* tew. tom
--a totar--t
tolut town. Cor wpor toy.
tenl mm. ftau tNMl teal Mi total Mwil Ctote
Ol--CUA tUAilft
totter Mwh, OV total Cm- feravm total imwI Onu
Ilium mb M|k --rn--
OO ScrWUr tour H 111 teiAijfl
car- ir'-*tei- flit. Cm* iw.<Mai wam tout cmiui imiL tew. car- towr.-ftpwl. 4 nit. to. tor- OMflfal. 1 Hit. toul tea. Oata-Aful. 4 nit. ten. Cap- HMOr.-Cntien Wp. tea. q. ceu*-Oictrw aifppp.
toul tea. Guo--- Maii toul NwmI 44U
IHMM 1 OMa MMk lU flVMI MMaar
Omm (Mlbt imt. on
toe. ftrp Sul vatar Oaitona, 90
Otter Pmati mail, to ^
total temt Kitari. OD
tout tPi US tea'dayl top. Inr.-Brwl. nit.
top. Iw.<vUw *tmp.
total top. latiuut
tea. C >. CA-w.-f.pMl. 4 nit.
tea. tor. *-u>r>rwi. 4 rut.
tout tea. C'.rTj.-t/.-al. 4 nit.
ten. top*
telaarp.
tea. \i. Oj-'*<u!a Maorp,
total tea. CMU^itcn teaerp.
. .
fUn *--( IMti
telarn tiwd Ma^ Ini t tiuip mu, ilk
O iti i lutnlau noun
mu
'
09 laluir Katara total top. tor. total tea. Gmu
top. la. Storage MMInf tew. OMt storafa 0414lay top. tor. nncritl tram. U4|. tew. Cbm HitcrUl Trww. II4|.
total CiriUi liwt-- total inul data
-
tei 74.404
a,M
.
44.744 to. 411
1.414 19.417
1.417 m.wi
m____ w____ w
o.
to.no 4,100 ).no 1.400
0.104 45.000 4.40?
0 0 0 0
1.444 04.440 10.704
IH.0M 14.174 10.444 . in ii. m
1.700
0 0
$.000
0
n.on 4
0 0 122,474
00
U1
0 4M.7n
0 74.074
0 0 904.on
0 4 44,on
0 0 H.m
0 0 70,in
0 4 u.in
0 19.100
0 ci.m
0 0 in.on
0 14.914
00
4
0 it.on
4 * W.M
0 19.0
0 140.074
41.on
m.on
0 10.114
9.704 17.014
0 4.177
0 0 10.470
0 21.777 0 74.949
1*740
12,004
90,074
m
1.191 02.074 u.nt
17,404 7.004 14,000
19,000
0
1
0 0 0 0 1
4 t 0 0 0 4 0 4 0 0
4 0 10,004
lt< M0 i.m 4.774
111
00,444 19.474
.1 1.414
17.477 1.417
74.11? 11.441
M. 472 1.114
1.719
1.140,117 190.410
19.491 1.414 1S.H9 1.417
m,m 44.291
m____ w____ w
M.m
I.4U
1.127
14.470 0 0 00 0
0{
0
m.eoo 91.700 574,007
17.779 7.494
9.400
si.oeo to.oso 74.400 4.442
27.900 74,900
1.119 1.490
10.947 74.174 49.000
12.141 1.070
11.917
1.417
444,117 109,714
421
141,444 M,797
1.117
144.417 24,141
--win
74,474 114.709
0
lit.790
It.til 141.924
0 17.794 127.4M
' ttia reason why Alternative A is believed able to achieve a greater reduction in FCBs discharged than the higher-cost Alternative B is that Alternative A minimizes the total water discharged through maximum use of cooling water and process water recycle. For the' eight plants. Alternative A shews 0.2 MOD versus . 5.1 MGS for Alternative B. On Idle cost side, carbon treatment (plus pretreat ment) is more expensive than recycling. It should be noted here that incineration of contaminated waters as utilized in the zero discharge analysis (Section 2.0) WHS not considered practicable for Alternative A because of the time requirements tOK development, design, and installation of wastewater incineration equipment.
AltSiTSJtive A appears equally applicable to both existing and new sources
although in new sources it seats likely that the rate of wastewater discharge
(SSSUning no Incinerator for liquid FCBs) could be reduced to even less than the
apparent eight-plant average of about 5,000 GFD (40,000 GPD of treated process
Mater (omitting incinerator) from eight plants on Table 4-1).
=
According to the Task II Final Report (Reference 1), a properly designed pratreabnant and carbon adsorption system should reduce PGBs levels in the effluent tD 0M ppb (one pg/lit) or below, which is also a typical limit of detection far FOBS' in routine laboratory analysis of industrial wastewaters. In addition, again baead on Reference 1 date, a total average FCBs level of 15 ppb in the untreated cooling water aid blowdowns from Alternative C appears practicable as a result of relatively minor changes (such as cleanout of existing piping, housekeeping Improvements, etc.)
On the above basis, the total projected discharge rates (to waterways) in pounds per 365 day year of FCBs from the eight plants for each alternative are (using one ppb as the FCBs level in carbon-treated water):
Alternative
A B. C Estimated Present Discharges frem Eight Plants
Projected FCBs Discharge, lb/year
0.5 15.5 227.4 978.0
-36-
MQNS 047447