Document O13E6o4EJ5d6V5pxyXaEgLRKe

The B F Goodrich Company BFG RESTRICTED BFG TECHNICAL DOCUMENT Corporate Research, 4032A-78 THE B. F. GflOBRtCH CO. "6 1978 DISTRIBUTION MAfl > * 1978 BFG CANADA P. B. Mason RESEARCH LIBRARY CHEMICAL DIVISION ENGINEERED SYSTEMS DIVISION E. A. Perry P. E. Perry A. D. Klingenberg Avon Lake Technical Center L. Crider-S. Shringarpurey Cleveland R. A. Krueger - M. E. Roha- F. A. Donat E. B. Osborne-D.G. Kuharik CORPORATE GROUPS GENERAL PRODUCTS DIVISION J. F. Auchter 0. Reldl C. L. Blackfan INTERNATIONAL BFG W. N. Dickerson F. A. Bellini G. A. Spaulding-J. R. Ledgerwood R&D Files (Z) Corporate Planning M. K. Wolverton TIRE DIVISION P. C. James R. A. Eisentrout R. L. Raun 21906001 Corporate Research D. E. Ley (2) R. J. Fawcett E. D. Dickens, Jr. C. E. Wilkes A. R. Berens .1? ' Corporate Technical Supi5tt P. M. Zakriski Patent Department E. G. Fiorito-J. R. Lindsay ^AW&ECIAL REPORT \\Y* <,0. PASSIVE DOSIMETERS by Michael A. Centanni and M. Peter Dreyfuss Information from th^a^document may not the consent of i, apied in whole or in part without! BFG 16964 n BFG RESTRICTED Reproduction Reproduction of BFG RESTRICTED, BFG TECHNICAL DOCUMENT, information is not allowed unless expressly approved by the person initially classifying the docu ment. or nis designee. Secondary Distribution and Dissemination BFG RESTRICTED, BFG TECHNICAL DOCUMENT may not be published or disclosed to anyone not on the original distribution list unless expressly approved bv tne per son. or his designee, having original classification authority of the document. Transmission: Internal transmission may be made either by hand-carrying between custodians, or via Company mail in a sealed envelope with the notation "To Be Opened By Addressee Only" indicated on the envelope. Transmission or removal of this document outside of tnis facility is not authorized without the express approval of the operating manager concerned, or in compliance with local removal procedures. See BFGoodrich Security Policy No. 300 tor external mailing procedures. Storage: BFG RESTRICTED, BFG TECHNICAL DOCUMENT must not be left exposed or un attended and must be stored under lock and key when not in use. Destruction: BFG RESTRICTED, BFG TECHNICAL DOCUMENT should be disposed of by shred ding, tearing destructively or burning to make its retrievability extremely difficult, if not impossible. BGl6965 21906002 *25 =?3o| Corporate Research, 4032A-78 SR, March 6, 1978 PASSIVE DOSIMETERS by Michael A. Centanni and M. Peter Drevfuss SUMMARY The Corporate Research New Ventures group has initiated a 1978 Feasibility Study on passive dosimeters. Prior to this, we conducted a preliminary analysis of the technical and business as pects of passive dosimeters as a new business opportunity for BFG. This report summarizes many of our findings. In their simplest form, passive dosimeters are small badges which can be clipped to the workers shirt pocket. And be used to monitor his personal work environment for air contaminants con sidered dangerous to his health and safety (ex.: VCM, benzene, lead dust, etc.). The list of chemicals that are monitored in the work place is large and growing rapidly. Several companies have intro duced passive dosimeters based on charcoal absorption. We see no rationale in BFG making charcoal based dosimeters, which are low in technology, and trying to compete in the marketplace. However, we can describe an "ideal" passive dosimeter that would be high in technical content and come much closer to satisfying the needs as perceived by all sides involved (govt., worker, management). Our feasibility study will be directed towards this "ideal" dosimeter and we discuss some technical concepts that might lead us to our goal. 21906003 THEB.F. GMHHCH resem ubrary BFG 16966 3 F GOODRICH Corporate Research, 4032A-78 -3- SR, March 6, 1978 CONCLUSIONS 1. The number of chemicals Chat are considered harmful to workers are large and growing in number daily. Many are already being regulated in terms of worker exposure. Monitoring the work environment for these chemicals will represent a significant and growing market for selected companies. We do not know if BFG should or will be one of chose companies but we feel a need to make sure the opportunity doesn't go by unnoticed. 2. BFG should not attempt to market a carbon absorption dosimeter because of the low technology involved and lack of a proprietary position. 3. If BFG is to compete, it should develop passive dosimeters that essentially eliminate the expensive chemical analysis step. 4. An "ideal" passive dosimter has the following features - good (less than 1 ppm) sensitivity - good selectivity - instant (plug-in) analysis - small size and light weight - represent a net cost savings to the user - be capable of recording peak exposures RECOMMENDATIONS The authors have initiated a feasibility study (4032A) and along with Sudhir Shringarpureyof Avon Lake Technical Center and Dan Hine, are currently working on the project. OBJECTIVES To consider and evaluate the business and technical oppor tunities in the area of passive personal chemical monitors. 21306004 BFG16967 3 F GOODRICH Corporate Research, 4032A-78 -4- SR, March 6, 1978 PATENT SITUATION Patents exist covering certain aspects of current badges. However, the new high technology badges that we propose to develop should allow for adequate patent coverage of our discoveries and developments. All passive dosimeters of the type here considered will probably require a static airgap. At least some aspects of this are disclosed and claimed in U.S. 3,950,980 assigned to the 3M Company (April 20, 1976). The claims seem rather narrow. Never theless, it seems there might be some litigation between 3M and Abcor (Walden Div.) on the basis of this patent. We do not know if there is or not. In any case, the Patent Law Department will have to carefully consider and render a judgment on this point. ACKNOWLEDGEMENTS Two "idea generation" meetings were held by D. Dickens and P. Zakriski in early 1977 as a means of identifying those people in the Company who might contribute to this project. We want to thank those involved, W. Kroenke, A. Berens, R. Whitehead, C. Carman, P. Nicholas, R. Childers, F. Doljack, A. Magistro, F. Ramp, R. Hooser, and Lee Traynor, for their time and subsequent dis cussions. In addition, we want to acknowledge conversations and significant help from Ron Myers, Sudhir Shringarpurey (ALTC), and John Born. 21906005 BFG16968 B F GOODRICH , -.t Corporate Research, 403<!a-7c -5- SR, March 6, 1978 INTRODUCTION A well-known problem of increasing concern to BFG is indus trial and chemical pollutants and government regulation thereof. The need to control and monitor these pollutants is commanding an ever-increasing amount of effort and expense. Can we turn this situation around to the extent that we can use it to generate business opportunities? One way to do this might be to develop and market new, novel, and effective monitoring devices. Such a business could involve selling only the devices; it might include a newly developed specialty instrument to read the results ob tained by the device; or it might include a service wherein we analyze and report the results, offering us the opportunity to establish a service related business. We were asked by means of this report to discuss and record the considerations we explored in the area of personal passive dosimeters as a new business oppor tunity. These considerations were preliminary to our undertaking a project in developing just such a new product. Some of the devices already in existence, which we have con sidered are: the Bendix Pump Monitor and the pumpless carbon absorption badges including a static air gap badge and a membrane diffusion badge. Some newer developments include 3 M's mercury badge; a modification of this concept by Scheide and Taylor(1) who used a quartz crystal as a micro-balance for determining exposure to mercury; and finally, a badge developed by Sudhir Shringarpurey^ J at the Avon Lake Technical Center for detection of organo-tins. We shall present some background information on all of these devices in the following paragraphs. We feel that it is necessary to inform ourselves and other interested people of these existing devices so that our directives can be more clearly defined. In the following paragraphs, we shall discuss both dynamic dosimeter and passive dosimeters which are already available on the market. We shall also discuss several new approaches to passive dosimeters. A. Bendix Pump Monitor -- The Bendix Pump Monitor has been in use at BFGoodricn since 1974. In that year we were faced with the urgent problem of how to effectively monitor employee's exposure to vinyl chloride monomer (VCM). The Bendix Pump Monitor has filled that urgent need since then. Over the years, we have gained much experience in the operation of the pump. These first generation badges use a mechanical pump to cycle air at a fixed rate through a tube containing activated carbon. At the end of the day, the tube is sent to the lab where it is analyzed for VCM. This analysis is both time consuming and costly. In addition to the expense of analyzing the tubes, there are other disadvantages to the pump monitor. One of the biggest BFG16969 21906006 Corporate Research, 4032A-78 -6- SR, March 6, 1978 disadvantages is their expense. Initially, they are about 5300 a piece. They can be used many times over; however, the expense associated with maintenance can be very large. They are mechanic;; 1 devices that are prone to breakdown. This brings us to an interfer ing point; if the pump breaks down when an ennlovee it wearing it, will the employee report it so that the malfunction can he cor rected? If not, then the reliability of die pump drops to nearly zero. In addition to being expensive and possibly unreliable, the pumps are noisy, bulky, and uncomfortable. B Pumpless Carbon Absorption Badges -- Since we are calling the Bendix Pump Monitors the first generation devices, these devices will be termed second generation devices. These badges are in the market development phase of commercialization by several companies and are under current evaluation by BFG. In fact, they will very likely replace the pump monitors. They are the badges of the immediate future. 1. Static Air Gap Badge -- There are presently two suppliers of the static air gap badge. They are Abcor (3-> and 3M(^,5) These badges also use activated carbon but instead of a pump, they employ a static air gap across which the pollutants diffuse to the carbon absorbent. Both badges use a draft shield made from a non-reactive porous material to isolate the air gap. The 3M badge uses a thin microporous film of isotactic poly(propylene) for such a shield. These wind screens insure that the amount of gas available to react with the activated carbon is a function of concentration. In both cases, the amount of gas collected is quite independent of the velocity and impingement angle of the gas mixture. Furthermore, both badges yield a time-weighted-average for exposure to solvent mixtures with the Abcor badge yielding information in the 0.5 - 150 ppm range. There are several apparent advantages of these second generation badges over the first generation badges. For example, the badges are passive devices and therefore require no maintenance. They are light-weight, simple, and seem to work. Furthermore, their cost is very low. In fact, the Abcor badges cotne to $3.72 per badge; on the other hand, the pumps, according to Abcor, come to either $4.80 or $6.80 a piece depending on whether yop already have the pumps or whether you have to buy them. See Table 1 for the breakdown on pricing. One of the disadvantages of these carbon absorption badges is that they are still carbon absorption devices. In this area, the technology has been somewhat stagnant. Of course, the analysis is the same as the pump analysis. Again, these analyses are both time consuming and costly. BFG 16970 21906007 Corporate Research, 4032A-78 SR, March 6, 1978 o o 00 O' rrHHc\ 0O)0 a to u oa. CO u 0) CO > u to to u 01 (0 co cj uH CCO *0H1 o O juz oo a u r4 </> <si o o <un mON 4aJ) </> o> H 0) 01 cn 3 NO--n' u CO u zO o ni o 0) a On 3 -H '-N. </> >s to <Si u n *H U3 o in f** 1 cn i i O1 </> in ON CNI o CM O o mO **T O .H(o0 o c(oH aL(0i CxJ J COJ flQ < H U CO o u (0 u o o .<d a; 00 CO 5 2^ ^ae ah= 9<soAOJ Dp-W oCO. 3 to ^ V- cl u3 *22 < o o om O </> oin ; * ih tn </> o. 3 CuO <010 5S m a. S3 a. o in <s> u <0 051s oorH </> <s> a 0) 3 5s T<30 H oo o o CM <o o 00 o oO o 00 cn vC 1 *1 1 o 00 <nC/> CO a. < u *<hLi a3- OJ oo tBOi m(0 iHHc c3o Jc=o a. a to to C3L a. o 0v31 *5(o0s occ cn a d> CH2 4H u (0 u c01 t0o1 0 X> J<0 01 *3 u01 u 01 h cn rH CO <0 H CL CO CQ X rH a. to co H uO uco |uH LJ <Uy d < CL ^CHO 4l 3 O *CH0 4H r4 hc-* 01 lh H rH CO 3 CO 0) u c co 0c1 cH CO c oH 4H Cr4O u 01 u a 01 0CO) u d oH JH CHO CJ 0V)a. a* o 01 Cl c Cd0 40J1 d H CO as CO 01 i--014 Ul A3 4_ Hd H CO 0CJ u 01 ooi rCHO cO Q. A 01 CJ C* *H H cp04 AJ d <0 *OH CO u AH 14 3 O >u CO CJ A O 0a1 -a O 3 to cCO vcO/> r0H1 a. rC0O u 01 a. w cn o a 0dC aj *H O c0n1 d. 3>P 01 Mc d> -1H31 Or4 <3- CD H rC-L cn 4J 01 tJ Z0 C3L. 01 c- c*CHl CL tCoO Li 01 Q* ij cn G 01 00 .u CO (0 CO 0 V) --* G 3 a V> a BFG16971 N t--k tfi o o o 0D Corporate Research. '.032A-78 -8- SR, March 6, 1978 2. Membrane Diffusion Badge -- This badge, marketed !rReal, uses a silicon rubber membrane as' a diffusion membrane. Siiice it is a diffusion controlled device, we feel that the response rime of the badge may be too slow, making it ineffective and unsuitable. Furthermore, their prices are very high, nearlv $40 per badge, ex cluding analysis. C. New Developments -- We shall call these badges third gener ation badges. These badges move away from carbon absorption and work toward chemical fixation and new absomtion techniques. There are presently two examples of such badges. 1. The first example is 3M's mercury vapor badge. It's cost is $20 including analysis and reporting of the results. Analy sis appears to be simple and inexpensive. The badge consists of a thin film of gold on a substrate. The mercury forms an amalgam with the gold and hence changes the conductivity of the gold. Therefore, in this case, the analysis is a simple conductivity measurement. 2. The second example is given by the work done by Scheide and Taylor at the National Bureau of Standards^). In their work, they used a quartz crystal as a sensitive micro-balance. The concept is to monitor the resonant frequency of a quartz crystal which is part of an active circuit. Interaction with the pollutant is accomplished through a chemical which is coated to the surface of the quartz. A gain or loss in weight will alter the resonant fre quency of the system (quartz plus coating). Scheide and Taylor have used this idea as a monitoring device for mercury vapor. They used gold as a fixant and were able to obtain a sensitivity of fractions of a part per billion in concentrations of mercury. An attractive feature of these sensors is that they are reversible. The mercury can be removed by heating the crystal in an oven at 150C in a stream of clean dry air. Scheide and Taylor were also able to show that air passed over the sensor at rates up to 300 cc/min does not affect the sensor stability. Minute changes in frequency occur when the flow is started and stopped. They attribute this fact to the adsorption and desorption of moisture from the substrated. Since all the crystals used were AT cut (a cut made at 35 18' to the Z axis), small vari ations in room temperature did not affect their stability in frequen cy. In addition, they determined that at flow rates of 100 cc/min, the response of the crystal was constant. The response was linear at higher flow rates but the sensitivity decreased and therefore, the precision of the measurements decreased. The range of the de tector was 500 nm (AF = 50 hertz). Their work dealt only with proto types, no efforts to put into the form of an area or a personal mon itor were reported. We are presently considering this means of using a quartz crystal for a badge to detect organic pollutants. The problem be comes finding a chemical which will fix the particular pollutants under consideration. In this particular type of detection system, BFG16972 21906009 Corporate Research, 4032 a-7.3 -9- SR, March 6, 1978 interferences can be a big problem. In fact, any molecule whi.i. h sticks to the substrate can change the resonant frequency of the quartz chip and therefore, give false readings. 3. The third example is given by an orcano-*. in badge developed at BFG by Sudhir Shringarpurev at the Avon Lake Technical Center. This particular badge, in its current stage of development, uses chemical fixation, but in combination with a mechanical pump. Since this badge uses a pump, it's not quite a third generation badge but lies somewhere in between a second and third generation badge. NATURE OF THE BUSINESS OPPORTUNITY A. Potential Market Size -- With the advent of the following government associations: N.I.O.S.H. (National Institute for Occupational Safety and Health), E.P.A. (Environmental Protection Agency), O.S.H.A. (Occupational Safety and Health Administration), and T.O.S.C.A. (Toxic Substances Control Act), stringent regula tions on occupational exposure to dangerous chemicals have been forced upon industry. These regulations have nearly insured a large and growing market for personal monitoring badges. Limits have been set for both a peak exposure and for a time-weightedaverage exposure. The latter was based on a 10-hour workday, 40hour workweek. Let us examine benzene, for example. The occupa tional exposure of benzene should not exceed one part per million for a 10-hour workday, 40-hour workweek. N.I.O.S.H. estimates that over two million people in the work force are exposed to benzene. Table 2 lists, in addition to benzene, other dangerous chemicals along with their time-weighted-average exposures and the estimated number of people in the work force exposed to the chemicals. Of course, the pollution does not stop at the workers. For instance, N.I.O.S.H. estimates that in large industrial cities, atmospheric concentrations of inorganic mercury approach a level of one microgram per cubic meter. The number of people exposed to sulfur and nitrous oxides is so large that N.I.O.S.H. will not even hazard a guess as to the number of people exposed. Just consider, for example, the number of policemen and firemen exposed daily to such pollution. B. Possible Approaches -- There are several ways in which we could move into the market. To begin with, we could sell a new and unique badge in addition to giving technical assistance. Another possibility is to sell a new badge and offer an analytical service either internally or contracted externally to BFG. Furthermore, we could sell a new and novel data analysis instrument. We could use our technology and develop a new and unique area monitor. Finally, we could just license and/or sell our newly developed technology. BFG16973 Z1906010 1. Benzene 2. Inorganic Arsenic 3. Ammonia 4. Trichloroethylene 5. Methyl Alcohol 6. Inorganic Mercury 7. Vinyl Chloride Monomer Corporate Research, 4C32A-78 -10- SR, March 6, 1978 TABLE II N.I.O.S.H. estimated num ber of workers exposed to the chemical 2,000,000 1,500,000 500,000 200,000 175,000 150,000 Time-Weighted-Average Exposure for.a 10-hour Workday. 40-hour work week unless otherwise specified 1 ppm (32 mg/m-*) 2 pg/m3 (15 minute sampling period) 50 ppm (5 minute sampling period) 100 ppm 200 ppm 0.05 mg/m3 -- 1 ppm C. Competition -- 1. Commercial -- There are already several second gen eration badges and at least one third generation badge on the market. They are produced by Abcor and 3M. Both companies make a passive carbon absorption badge. In addition, 3M makes a mercury vapor badge which is definitely third generation. It is highly probable that more will appear on the market. In fact, 3M has been working in this area for several years. Moreover, they have a division of occupational health and safety products. The company is both innovative and aggressive and will certainly develop more monitors. 2. Government -- N.I.O.S.H. is a government sponsored research agency that is currently interested in personal monitoring devices. In their case, however, the projects are generally speci fic and not very likely to result in a competitive product. Appar ently, the National Bureau of Standards is also interested in such monitors as exhibited by the work done by Scheide and Taylor. 3. Universities and Research Groups -- Many universities and research centers are involved in badge studies. One research group currently involved is the Gulf South Research Institute. They do contract work for both the government and for industry. Paul Zakrisky has interacted with them and inquiries about GSRI should be directed to him. BFG16974 21906011 Corporate Research, 4032A-78 -11- SR, March 6, 1978 Both Louisiana State University and the University of Toronto have done extensive work on personal monitoring devices. These are just two universities of many that are involved in such work. The University of Toronto has recently published a paper on the monitoring of nitric oxide. The nitric oxide forms a second stable radical with the free radical reagent, 2-phenyl-4,4:3,3- tetramethylimidazoline 3-oxide 1-oxyl. The free radical reagent ie applied in chloroform solution to silica gel plates. The second radical, formed after the reaction, is quantified by electron srin resonance. It is certainly feasible that such work may lead to patent and licensing rights. NATURE OF OUR TECHNICAL STRATEGY In our approach, we hope to learn from chlorinated substances and Shringarpurey's organo-tin badge. We are certainly technically competent in chlorinated materials, and are already well into high technology badges with the organo-tin badge. In our opinion, the largest markets are represented by ben zene, acrylonitrile, sulfur and nitrous oxides, carbon monoxide, asbestos, and heavy metals such as lead, mercury, beryllium, and arsenic. We will concentrate our efforts in some of these materials as the project develops. A. The Ideal Badge -- We have considered the desirable char acter iitTcs-oF-an-T3eii badge. During our work, we will keep these attributes in mind. To begin with, we need a badge that is sensi tive; the threshold limit values of many dangerous chemicals are on the decrease. Certainly, a badge sensitive to one part per billion is more than adequate. The badge should provide for easy and fast read-out of the pollutant concentration. Another attractive feature would be to have available the read-out of both the timeweighted-average and the peak exposures. We would like the response to be in direct proportion to the pollutant concentration inhaled by the wearer. Interferences should be kept to a minimum. Finally, where more than one pollutant is present, synergistic effects should be taken into account by the badge. The following table summarizes these characteristics. One must keep in mind that the real product will inevitably be a compromise but the more we can incorporate into the badge, the better chance we have of developing a highly marketable product. BFG16915 Z190601Z If -12- Corporate Research, 4032A-7S SR, March 6, 1978 TABLE 3 Characteristics of an Ideal Badge 1) Sensitive to one part per billion. 2) Should provide for easy and fast read-out of pollutant concentration. 3) Read-out both time-weighted-averages and peak exposures. 4) Badge response in proportion to the pollu tant concentration inhaled by the user. 5) No chemical interferences. 6) Synergisms taken into account. 7) A new economic savings over existing methods. B. Chemical and Physical Fixation -- 1. Chemical -- Under chemical fixation, there are several, concepts that we are considering. They are: 1) covalently bond a specific chemical reagent for a given pollutant to a polymer matrix. 2) absorb these specific chemical reagents on a substrate; for example, silica or a poly crown ether. 3) use of strong oxidants such as potassium permanganate. 4) use of inorganic olefin complexes. 5) badges which change color such as PdCl2 when exposed to CO. 6) badges which use electrochemical cells. 2. Physical -- Recently, Ron Myers has brought to our attention one of a class of clathrate substrates The one we looked at is Tris(o-phenylenedioxy) cyclotriphosphazene, which upon contact with an organic compound undergoes a structural change from monoclinic or triclinic to hexagonal with consequent inclusion of the organic compound into the crystal lattice. The molecular weight of this material is 459 and it requires two host molecules BFG16976 21906013 -13- Ccrporate Research, 4032A-78 SR, March 6, 1978 to retain one guest molecule. Its melting point is 244<:C - 245C and it has the following structure: On the one guest to two host molecules premise, we have calculated a gain in weight of about 10% for toluene as the guest substance. Experimentally, under saturation conditions, we obtained weight gains in the range of 9% to 107. for all three samples of varying sizes. It must be emphasized that these results are very prelim inary. C. New Analytical Methods --As previously mentioned, one idea we have, which incorporates a new analytical method, is the use of a quartz crystal as a sensitive micro-balance. This would lend itself to direct and fast read-outs. We may consider using a micro-processor as an analyzing unit. At this time, selling both the badge and the instrument looks attractive. D. Potential Problems -- We cannot anticipate all the prob lems that can occur in this effort. However, besides the more obvious problems related to not achieving the "ideal" badge per formance, we have uncovered some other problems that warrant atten tion: 1) field testing - will outside firms test our badge and share their data with us? 2) certification - how do we do about getting our badge certified by N.I.O.S.H.? 3) regulated nature of market - the government really controls the rate of market expansion by intro ducing new chemicals on their list of toxic sub stances and by altering the limits of exposure of the same. 4) other means of solution - some businesses may shrink. For example, the removal of enough VCM from the resin so that the residual amount is below the threshold limit value would reduce the market for a VCM passive dosimeter. BFG16977 jl )k' h W 0906TZ -14- Corporate Research. 4032a-73 SR. March 6. 1973 5) peak exposure - how important is it to be able to detect peak exposures? Will the government make the monitoring of peak exposures a regulation? E. Internal Use of Our Technical Results -- We feel that BFG is interested internally in the use of passive dosimeters to moni tor personal exposure to dangerous chemicals. Of course, our immediate interest is with the detection of VCM. As a result of this, our main thrust will be in this area. If we do develop such a badge, the capability of in-house testing will aid us tremendousLy in evaluating the effectiveness of the badge. MICHAEL A. CENTANNI bl 21906015 BFG16978 -15- Corporate Research, 4037.A-7 8 SR, March 6, 1978 REFERENCES 1. Scheide, E. P. and J. K. Taylor, Environ. Sci. Technoi., 8, 1097 (1974). 2. Shringarpurey, S., private communication. 3. Tompkins, Jr., F. C. and R. L. Goldsmith, Am. Ind. Hyg. Assoc. J..'38. 371 (1977). 4. Braun, D. L.: Personal Monitoring of Mercury Vapor Exposures, ICESA, Vol. 2, IEEE Catalogue #75-CH 1004-1, (1976). 5. McCammon, Jr., C. S. and J. W. Woodfin, Am. Ind. Hyg. Assoc. J., 38, 378 (1977). 6. Abcor Development Corp., Product Bulletin, "GasbadgeTM Dosimeter for Organic Vapor" (1977). 7. Nadeau, J. S. and D. G. B. Boocock, Anal. Chem., 49, 1672 (1977). 8. Allcock, H. R., Chem. Rev., 72, 342 (1972). 9T0906T2 BFG16979 *. F . .vocpmt