Document O11MeDe8j4VVbYEXpDdeJ8VLK
PLAINTIFFS EXHIBIT
DOW CHEMICAL U.S.A.
DOW-1946
(
lOUIfUUM OtVlBtOH
^UOUIMWIC. kOmWAMA fOT9*
104
INDUSTRIAL KYGIZXR R2P0RT
rvTj. SERVICE 6 CHLOR-ALXALI I AREA ASBESTOS UPDATE SURVEY
Fn-E NO. 115-17-10
DATE
October 17. 1975
AUTHOR /U--------J.
O
CHECKED
DATE Id ~/7~ >S~~
SQMM.UY
Conducted an update asbestos survey for the second half of 1975 at Cell ' Service and the old Chlor-Alkali I area, which is used for building and repairing chlorine cells.
<jO
( Results were favorable, ar.d well within OSHA's standard of S fibers greater than S microns in length per cubic centimeter and Dow's standard of 2 fibers per cubic centimeter. (The OSHA standard will be lowered to 2 fibers per cubic centimeter in 1976.)
Survey findings ranged from .29 fibers per cubic centimeter in the drawing area, while an operator was drawing M-82 cathodes, to a low of .02 fibers par cubic centimeter in the electrician's workbench area which is adjacent to and above the drawing ares.
Asbestos rope and paper have been replaced in the cell production, thus eliminating two sources of asbestos exposure.
Although survey results were favorable, we must adhere strictly to safe handling procedures. Supervision is responsible for enforcing safety precautior
Bldg.
S. D. Campbell 2601
G. W. Daigre
2501
E. P. Edwards 3701
Medical
2303
R. L. Peebles S. T. Richardson W. Vosburg File (2)
Bldg. 3701 2601 2601 2501
MIDLAND
FREEPORT
R. Langner
1803
R. L. Daniel
B-101
(
aw OWMWO UNIT OP TMC OOW riUMWtl COMPANY
i--antif
STOI 75028
1*
SURVEY RESULTS
(Fibers greater then S microns in length per cubic centimeter)
1. .05 - Stationery sample at addition vat - Cell Service drawing area. 2. .29 - Operator drawing M-82 cathodes - Cell Service drawing area.
9
3. .13 - Stationary sample - InsideCA-I asbestos mixing room. 4. .19 - CA- I laborer mixing blue asbestos and applying to cells. 5. .15 - Stationary sample - Inside CA-I asbestos mixing room. 6. .06 - Operator drawing M-82 cathodes - Cell Service drawing area. 7. .02 - Stationary sample - Asbestos scrubber exhaust vent - Cell Service 8. .02 - Stationary Sample - Entrance to asbestos storage room. 9. .04 - Cell Service laborer - Hooking up cathodes in drawing area. 10. .08 - Stationary sample - CA - I exhaust from asbestos mixing room. 11. .07 - Stationary sample - Middle of CA - I work area.
.12 .02 - Stationary sample - Cell Service electrician'sworkbench area.