Document NzGomvMOVBBLBjjzJXVx98Ry
BENDIX
Cl 15 PERSONNEL MONITOR
the only air sampler with . . . AUTOMATIC VOLTAGE REGULATION Gives absolutely constant reading of 2% Guarantees 8 hours of midget impinger sampling
2.8 LPM AP12"H>0 Guarantees 14 hours of gravimetric sampling at
2 LPM AP 4" H*0 Eliminates flow rate adjustments during sampling
period.
FLOAT PULSATION ELIMINATOR Ends float bounce for precise reading
BUILT-IN BATTERY VOLTAGE TESTER Allows instant check of battery condition
r\ j
10713 FAUSTONE HOUSTON, TEXAS 77072
* P. 0. BOX 92 HOUSTON, TEXAS 77DOS
THE TACKABERRY COMPANY
SINCE 1946 * (713) 4984880
oo HS \
000011^55 OCR
-c;v ' H fi'iL
BENDIX
C-115 PERSONNEL AIR SAMPLER
Guaranteed to collect 99% of the sample . . . exceeding the rigid requirements of and approved by the Bureau of Mines for Intrinsically Safe Operation in Explosive . Atmospheres. Bendix superiority is demonstrated in the Cl 1 5 PERSONNEL MONITOR. LIGHT WEIGHT, COMPACT and VERSATILE ... the Cl 15 is an air sampler offering advanced features found in no other instrument in the field and may be used with midget impingers, micro impingers, membrane filters or respir able mass samplers. Powered by a 7.5 volt, 2 amp-hour rechargeable nickel cadmium battery, the Cl 15 is supplied complete with a 110 volt/60 cycle battery charger. A precision diaphragm pump and hi-torque low current drain motor insures high efficiency monitoring.
Here's why the Cl 15 can give you 99% sampling accuracy
FEATURES
AUTOMATIC VOLTAGE REGULATOR Gives absolutely constant reading of 2%. Guarantees 8 hours of midget impinger sampling at 2.8 LPM AP 12" HaO Guarantees 12 hours of gravimetric sampling at 2 LPM A P 4" HaO Eliminates flow rate adjustments during sampling period
FLOAT PULSATION ELIMINATOR Ends float bounce for precise reading
BUILT-IN BATTERY VOLTAGE TESTER Allows instant check of battery condition
LEAD-IN-AIR ANALYSES Simple 3-step procedure provides accurate analysis using Bendix Inorganic Lead-inAir Reagents.
TDI-MDI DETERMINATIONS Will provide threshold limit values from 0:01 to 0.08 PPM using Bendix reagents and color standards.
C-115 PUMP PROVIDES THE NECESSARY VACUUM FOR PRACTICALLY ANY PORTABLE GAS ANALYSIS TEST
The C-115 is designed for the collection of toxic and combustible gases, vapors, dusts, fumes, and mists which are then evaluated by various analytical techniques. Numerous Bendix portable gas detection instruments and Colorimetric Detector Tubes can be used with the Sampler. The device, therefore, can be used to collect samples of explosive gases, oxygen, ammonia, carbon dioxide, carbon monoxide, chlorine, hydrogen chloride, hydrogen sulfide, mercury vapor, nitrogen dioxide, sulfur dioxide, toluene diisocyanate, lead dust and fumes, and chromic acid mist. Dust counts can also be made, using Midget Impingers in conjunction with a microscopic analysis. Particulate
sampling can be performed for radioactive dust and beryllium dust. A desired sample flow is obtained by setting the flow adjust screw to an indexed position on the flow meter. Our standard instrument comes factory calibrated at 2.8 LPM and 2.0 LPM. Special air flow calibrations are available on request. The C-115 is equipped with a tube fitting on the outlet or exhaust side of the pump. It can be used in positive pressure applications.
CCR 0 0 0 0 1 1 6 5 6
O
impinger sampling
The C-11 5 Air Sampler is designed for use with Bendix Calibrated Midget Impingers and Bubblers in sampling dust, gases, and vapors. It is the only Personnel Air Sampler on the market that guarantees 8 hours of continuous sampling at 2.8 LPM A P 12" HaO.
Threshold Limit Value Determinations from 0.01 to 0.08 PPM using Bendix TDI-MDI Reagents and Color Standards (Toluene Diisocyanate/MethyleneBis (4 Phenyl isocyanate) are accomplished with the use of the midget impinger.
RESPIRABLE MASS LAPEL SAMPLER
The Lapel Sampler, when used with the Bendix Cl 15 Pump, simulates the collection characteristics of the human lung. As air is sampled, the cyclonic action of the unit separates the coarser particles of dust (those which would deposit in the upper respiratory passage) from the finer, more harmful particles which penetrate into, the lung. The larger par ticles fall to the bottom of the tube, the finer particles are drawn to the filter assembly in the capsufe. where they are trapped on a filter mem brane for subsequent analysis, either weighing or counting. Approved by the Bureau of Mines for Intrinsically Safe Operation in Explo sive Atmospheres and the Environmental Health Service Bureau of Occu pational Safety and Health.
;-:b
RESPIRABLE DUST SAMPLER
DF.C 2 6 1373
Filter Paper Holder adapts the Cl 15 for MEDICAL 01Vpersonnel monitoring or sampling for the detection of lead dust, radioactive particulate, beryllium and other hazardous particulates.
ANALYZER FOR INORGANIC LEAD FUMES*
Simple 3-step procedure provides accurate analysts exceeding the requirements of the "Occupational Safety and Health Act of 1970." Using Bendix Inorganic Lead-in-Air Reagents and Color Standards, measures accurately within a range from 0.02 mg./m3 to 0.4 mg,/m3 of inorganic lead. This field method for atmospheric sampling provides immediate and accurate determinations of semiquantitative lead concentration in air throughout an entire workday. In contrast to the chemical method that could take 8 hours or more, the field method for analyzing the same number of samples requires less than 10 minutes with the Cl 15.
ANALYZER FOR TDI AND MDI**
The Cl 15. when used with calibrated midget impinger, will provide Threshold Limit Value De terminations from 0.01 to 0.08 PPM using Bendix TDI-MDI Reagents and Color Standards (Toluene Diisocyanate/Methylene-Bis (4 Phenylisocyanate).
CCR 00OU657
OEC 2 6 :-'73
MEDICAL DIV.
Cl 15 ATTACHE UNIT 3600-18
1
For total convenience the Cl 15, battery charger and ail accessories fit compactly into this handsome
attach^ style carrying case. Case provides excellent
1 protection for unit, while portfolio in cover is ideal
for valuable reports, test papers, instruction litera
ture and suggestions for care of unit.
Description
Part Number
C-11 5 Air Sampler w/Battery and Charger 3650-10
C-11 5 Air Sampler Only
3650-05
Nicad Battery 7.5V Battery Charger 110V 60Hz
3600-31 3600-20
Standard Calibrated Midget Impinger Impinger Holder
7202 3600-35
Sampling Head Assy w/Cyclone,
Hose and Clip
3900-90
Sampling Cassette/Capsule Assembly 3900-906
Filter Holder 25 mm Pkg. of 6
1107
Filter Holder and 37 mm Membrane 3600-309 Filter (0.8 Micron Size} for Asbestos
Dust Sampling.
Description
Part Number
*37 mm 3-Part Plastic Filter Holder.
3600-300
*37 mm Membrane Filter (0.8 Micron Size).
3600-301
Filter Paper 25 mm Pkg. of 100
60692
2 ft. Rubber Tubing 3/16 ID Code 40/20 Inorganic Lead-In-Air
2110-32
Reagents with Color Standards for Lead
Dust in air evaluation (50 evaluations) 2250-10
TDI/MDI Color Standards
2200-30
TDI/MDI Reagents
2200-20
Attach^ Case w/Ethafoam Insert
3600-18
'Part Nos. 3600-309,3600-300 and 3600-301 Filter Holder and Filter Media (0.8 Micron Size) complies with Federal Register Regulations 1910.93a for Asbestos Dust Sampling.
* Ref. Enrique A. Quino -- Field Method for the Determination of Inorganic Lead Fumes in Air -- The Journal of the American Industrial Hygiene Association -- Vol. 20. No. 2 (April 1959). Printed in U.S.A.
Ref. Marcali, Kalman -- Microdetermination of Toluenediisocyanates in Atmosphere -- Anal. Chem: 29, 552 (April 1957).
K. E. Grim and A. L. Linch -- Recent Isocyanate-ln-Alr Analysis Studies -- AIHA: Vol. 25 (May-June 1964).
NATIONAL ENVIRONMENTAL INSTRUMENTS, INC
P. 0. Box 590, Pilgrim Station, Warwick, R. I. 02888
Tel. (401) 738-3710
Cable NEICO TWX 710 387-1584
Distributed by:
CCR 000011658